Plan Review Details - Permit 19030794
Plan Review Stops For Permit 19030794
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-04-19 Cont ID  
Sent By pvalenti Date 2019-04-19 Time 09:01 Rev Time 0.00
Received By pvalenti Date 2019-04-19 Time 09:01 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2019-04-08 Cont ID  
Sent By pvalenti Date 2019-04-08 Time 07:50 Rev Time 0.00
Received By pvalenti Date 2019-04-08 Time 07:03 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-04-19 Cont ID  
Sent By cthroop Date 2019-04-19 Time 09:23 Rev Time 0.00
Received By cthroop Date 2019-04-19 Time 09:23 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2019-04-09 Cont ID  
Sent By jpearson Date 2019-04-09 Time 08:04 Rev Time 0.00
Received By jpearson Date 2019-04-08 Time 15:50 Sent To I
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2019-04-18 Cont ID  
Sent By fmittner Date 2019-04-18 Time 09:14 Rev Time 0.00
Received By fmittner Date 2019-04-18 Time 09:14 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2019-03-25 Cont ID  
Sent By fmittner Date 2019-03-25 Time 13:44 Rev Time 0.00
Received By fmittner Date 2019-03-25 Time 13:44 Sent To  
Notes
2019-03-25 13:52:02PROPERTY LOCATED IN HISTORIC DISTRICT, ROOFLINE CAN NOT
 BE ALTERED AND VINYL MATERIAL NOT PERMITTED ON
 BUILDING.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-04-19 Cont ID  
Sent By cthroop Date 2019-04-19 Time 09:23 Rev Time 0.00
Received By cthroop Date 2019-04-11 Time 16:00 Sent To  
Notes
2019-04-12 16:00:17R28

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2019-04-09 Time   Rev Time 0.00
Received By lmarchan Date 2019-03-18 Time 15:21 Sent To  
Notes
2019-03-19 15:22:07R07

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2019-04-06 Cont ID  
Sent By cmontell Date 2019-04-06 Time 07:28 Rev Time 0.00
Received By cmontell Date 2019-04-06 Time 07:28 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-04-17 Cont ID  
Sent By thunt Date 2019-04-17 Time 17:10 Rev Time 0.00
Received By thunt Date 2019-04-17 Time 17:10 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-04-05 Cont ID  
Sent By cthroop Date 2019-04-05 Time 14:54 Rev Time 0.00
Received By thunt Date 2019-04-05 Time 14:54 Sent To  
Notes
2019-04-05 15:07:06PLUMBING 1ST REVIEW**DENIED**
  
 1) PLUMBING FLAT DRAWING AND PLUMBING ISOMETRIC DON'T
 MATCH. FBC 107.3.5
  
 2) SHOWER IS NOT PERMITTED TO BE WET VENTED BY THE
 WASHING MACHINE AND IT APPEARS FROM THE PLAN
 MEARSUREMENTS THE DISTANCE FROM THE POINT OF VENT TO
 THE P-TRAP IS OVER 8' FBC -P 909.1. ALSO THE WASHING
 MACHINE IS NOT PERMITTED TO DISCHARGE INTO THE BATHROOM
 GROUP WET VENT AS SHOWN OF THE ISOMETRIC. FBC-P 912.1
  
 3) THE OLD PLAN SHOWED A TANKLESS IS THE WATER HEATER
 AT THE NEW LOCATION TANKLESS? IF THE WATER IS STORAGE
 TYPE PROVIDE PAN DETAIL SHOWING HOW THE PAN DRAIN IS
 GOING TO DISCHARGE TO THE OUTSIDE AND TERMINATED NOT
 LESS THAN 6" FROM THE GROUND SURFACE. FBC-P 504.7.2.
 THE ACCES SHOULD TO THE WATER HEATER MUST BE LARGE
 ENOUGH TO ALLOW SERVICE AND REPLACEMENT OF THE WATER
 HEATER. 502.5
  
 TIM HUNT
 PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR
 CITY OF WEST PALM BEACH
 561-248-2703
 [email protected]
 [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2019-03-25 Cont ID  
Sent By fmittner Date 2019-03-25 Time 13:44 Rev Time 0.00
Received By fmittner Date 2019-03-25 Time 13:44 Sent To  
Notes
***NONE***