Plan Review Stops For Permit 19030722 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2019-05-24 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-05-24 |
Time |
16:29 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-05-24 |
Time |
16:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2019-05-01 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-05-01 |
Time |
08:15 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-04-30 |
Time |
14:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2019-06-07 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2019-06-07 |
Time |
14:55 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2019-06-07 |
Time |
14:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2019-05-30 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2019-05-30 |
Time |
13:52 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2019-05-30 |
Time |
13:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2019-05-01 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2019-04-16 |
Time |
09:38 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2019-04-16 |
Time |
09:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
Rev No |
2 |
Status |
P |
Date |
2019-05-30 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2019-05-30 |
Time |
13:53 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2019-05-30 |
Time |
13:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
Rev No |
1 |
Status |
P |
Date |
2019-05-01 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2019-05-01 |
Time |
10:02 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2019-05-01 |
Time |
10:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2019-05-21 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2019-05-21 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2019-05-21 |
Time |
12:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2019-04-02 |
|
|
Cont ID |
|
Sent By |
scaldero |
Date |
2019-04-02 |
Time |
13:47 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2019-04-02 |
Time |
13:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2019-06-17 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2019-06-06 |
Time |
14:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2019-06-05 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2019-05-20 |
Time |
09:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-05-01 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-05-01 |
Time |
08:22 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-03-26 |
Time |
10:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
N |
Date |
2019-05-01 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-05-01 |
Time |
08:15 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-05-01 |
Time |
08:15 |
Sent To |
|
|
Notes |
2019-05-01 08:16:12 | NO CHANGE IN AREA OR OCCUPANCY. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2019-06-17 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2019-06-17 |
Time |
07:41 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2019-06-17 |
Time |
07:41 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2019-06-05 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2019-06-05 |
Time |
12:12 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2019-06-05 |
Time |
12:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2019-04-16 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2019-04-16 |
Time |
09:04 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2019-04-16 |
Time |
08:49 |
Sent To |
|
|
Notes |
2019-04-16 09:21:16 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT #19030722 | | 4/16/19 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEETS M0.1 & M2.1: THE PLAN APPEARS TO SHOW VAV-3 | | SUPPLYING 1440 CFMS OF AIR, HOWEVER THE SCHEDULE | | INDICATES IT HAS A MAXIMUM CAPACITY OF 900 CFMS. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
P |
Date |
2019-06-17 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2019-06-17 |
Time |
07:47 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2019-06-17 |
Time |
07:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2019-06-17 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2019-06-17 |
Time |
07:25 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2019-06-17 |
Time |
07:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2019-06-05 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2019-06-05 |
Time |
12:13 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2019-06-05 |
Time |
12:13 |
Sent To |
|
|
Notes |
2019-06-05 12:13:59 | MECHANICAL AND ELECTRICAL PLANS ARE DIGITALLY SIGNED, | | BUT NOT SEALED. | | | | 1) 107.2.1 FBC [AMENDED] PLACE A DIGITALLY CREATED | | IMAGE OF YOUR SEAL AND THE FOLLOWING SENTENCES WHERE AN | | ORIGINAL SIGNATURE WOULD APPEAR IF THE ITEM WERE BEING | | PHYSICALLY SIGNED DATED AND SEALED. THE SENTENCES CAN | | BE PART OF THE DIGITAL SIGNATURE CUSTOM APPEARANCE | | AVAILABLE IN THE SIGNING TOOL, OR THEY CAN BE PLACED ON | | THE DOCUMENT OUTSIDE OF THE DIGITAL SIGNATURE BLOCK. | | THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY | | [LICENSEE, RA, OR LS] ON THE DATE AND/OR TIME STAMP | | SHOWN USING A DIGITAL SIGNATURE. | | -PLEASE ADD A DIGITALLY CREATED IMAGE OF YOUR SEAL TO | | PLANS. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | | | | | | 2019-05-24 16:29:38 | A SHEETS OK |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2019-05-01 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-05-01 |
Time |
08:22 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-05-01 |
Time |
08:22 |
Sent To |
|
|
Notes |
2019-05-01 08:22:02 | 1) 107.2.1 FBC[AMENDED] PLACE A DIGITALLY CREATED IMAGE | | OF YOUR SEAL AND THE FOLLOWING SENTENCES WHERE AN | | ORIGINAL SIGNATURE WOULD APPEAR IF THE ITEM WERE BEING | | PHYSICALLY SIGNED DATED AND SEALED. THE SENTENCES CAN | | BE PART OF THE DIGITAL SIGNATURE CUSTOM APPEARANCE | | AVAILABLE IN THE SIGNING TOOL, OR THEY CAN BE PLACED ON | | THE DOCUMENT OUTSIDE OF THE DIGITAL SIGNATURE BLOCK. | | THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY | | [LICENSEE, RA, OR LS] ON THE DATE AND/OR TIME STAMP | | SHOWN USING A DIGITAL SIGNATURE. | | -PLEASE ADD A DIGITALLY CREATED IMAGE OF YOUR SEAL TO | | PLANS. | | | | 2) 107.2.1 FBC[AMENDED] SHEETS UPLOADED INTO DRAWINGS | | FOLDER ARE NOT DIGITALLY SIGNED. | | -RE-LOAD SHEETS WITH DIGITAL SIGNATURE. | | | | DYLAN BATTLES | | BUILDING PLANS EXAMINER PX4191 | | [email protected] | | 561-805-6718 | | | 2019-04-16 09:38:08 | ELECTRICAL PLANS NOT SIGNED AND SEALED JLEAHY | 2019-04-16 09:05:19 | MECH PLANS NOT DIGITALLY SIGNED AND SEALED. |
|
|