Plan Review Details - Permit 19030492
Plan Review Stops For Permit 19030492
Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-05-06 Cont ID  
Sent By jpearson Date 2019-05-06 Time 08:39 Rev Time 0.00
Received By jpearson Date 2019-05-06 Time 08:39 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-04-04 Cont ID  
Sent By jpearson Date 2019-04-04 Time 07:19 Rev Time 0.00
Received By jpearson Date 2019-04-04 Time 07:01 Sent To  
Notes
2019-04-04 07:12:38CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. REVISION APPLICATION STATES THAT THERE IS NO
 INCREASE IN VALUE FOR THE WORK PROPOSED. SEVERAL ITEMS
 ARE BEING ADDED TO THE ORIGINAL PLAN. VALUE FOR WORK
 STATED ON PERMIT APPLICATION APPEARS LOW. PROVIDE COPY
 OF SIGNED CONTRACT WITH SCOPE AND VALUE OF ADDED WORK,
 TO INCLUDE ALL MATERIALS AND LABOR. WPB FBC 109.3
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2019-05-06 Time   Rev Time 0.00
Received By lmarchan Date 2019-04-24 Time 10:47 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-04-04 Cont ID  
Sent By thunt Date 2019-04-04 Time 07:56 Rev Time 0.00
Received By thunt Date 2019-03-12 Time 13:50 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-05-03 Cont ID  
Sent By gjohnson Date 2019-05-03 Time 13:11 Rev Time 0.00
Received By gjohnson Date 2019-05-03 Time 13:11 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-04-04 Cont ID  
Sent By gjohnson Date 2019-04-04 Time 07:55 Rev Time 0.00
Received By thunt Date 2019-04-04 Time 07:35 Sent To I
Notes
2019-04-04 07:55:34PLUMBING REVISION1ST REVIEW**DENIED**
  
 1) BY REMOVING THE STORM DRAINAGE PIPING FROM THIS AREA
 HOW DO YOU INTEND TO HANDLE THE RAIN WATER RUN OFF AND
 COMPLY WITH FBC-P 1101.2 DISPOAL OF STORM WATER BY
 MEANS OF AN APPROVED PLACE OF DISPOSAL.
  
  
 TIM HUNT
 PLUMBING PLANS EXAMINER
 BUILDING DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
 561-248-2703
 [email protected]
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2019-04-04 Cont ID  
Sent By jpearson Date 2019-04-04 Time 07:05 Rev Time 0.00
Received By jpearson Date 2019-04-04 Time 07:05 Sent To  
Notes
***NONE***