Plan Review Stops For Permit 19030429 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2019-08-20 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-08-20 |
Time |
11:10 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-08-20 |
Time |
07:55 |
Sent To |
|
|
Notes |
2019-08-20 11:10:55 | BUILDING REVIEW APPROVED WITH PROVISO: | | 1- PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH SEC. | | R401.3 FBC-RESIDENTIAL. SEC. 107.2.5 CITY AMENDMENTS | | AND SEC. 110.9 CITY AMENDMENTS. | | 2- ENGINEER OF RECORD TO SPECIFY ROOF TILE FASTENING AS | | REQUIRED BY SEC. 107.2.1.1 CITY AMENDMENTS. IF | | SPECIFYING ROOF TILE ADHESIVE, THEN NEED PRODUCT | | APPROVAL. IF SPECIFYING SCREWS, THEN SPECIFY SCREW SIZE | | AND NUMBER OF SCREWS. | | 3- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.001 FOR: | | A)WINDOW MULLIONS AND SPECIFY MULLION SIZE. | | B) ROOF TILE ADHESIVE IF SPECIFIED BY THE ENGINEER OF | | RECORD. AND CLEARLY MARK PADDY SIZE. | | C) DOUBLE DOORS AS SHOWN FOR NEW STORAGE. | | D) RIDGE VENT SPECIFIED BY THE ENGINEER OF RECORD ON | | PAGE 9.0 OF DRAWINGS SUBMITTED. | | 4- NEW ENGINEER OF RECORD TO REVIEW AND APPROVE IN | | WRITING ALL PRODUCT APPROVALS AS REQUIRED BY SEC. | | 107.3.4.1 CITY AMENDMENTS. | | 5- ENGINEER OF RECORD SPECIFIES RIDGE VENT. SEE ATTIC | | SPACE VENTILATION CALCULATIONS ON PAGE 9.0. ENGINEER TO | | PROVIDE DETAILS/SPECIFICATIONS SHOWING HOW PROVIDING | | THE RIDGE VENT VENTILATION. SEC. 107.2.1 CITY | | AMENDMENTS. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2019-06-20 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-06-20 |
Time |
16:39 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-06-20 |
Time |
13:54 |
Sent To |
|
|
Notes |
2019-06-20 16:43:57 | RESIDENTIAL (R3) ADDITION/ALTERATION SECOND BUILDING | | REVIEW CHECKLIST. | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | | | NOTE: | | BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO | | MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER | | THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID | | CONFLICTS/DELAYS. REVISION FEES MAY APPLY. CONTRACTOR | | TO ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME | | OR IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT | | ISSUANCE. | | ****NEED ENERGY CALCULATIONS TO BE PROPERLY SIGNED BY | | THE OWNER AND ALL PLANS NEED THE ENGINEER'S SEAL AND | | SIGNATURE BEFORE APPROVAL. | | | | | | | | ORIGINAL COMMENT: | | 1- PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE | | FOLLOWING: | | SEC. R401.3 FBC-RESIDENTIAL (DRAINAGE). | | SEC. 107.2.5 CITY AMENDMENTS (SITE PLAN). | | SEC. 110.9 CITY AMENDMENTS (IMPACT OF CONSTRUCTION). | | | | RESPONSE: | | REPEAT COMMENT. NOT ADDRESSED. | | | | 2- OK. | | | | 3-OK | | | | ORIGINAL COMMENT: | | 4- A)DESIGN PRESSURES SHOWN FOR NEW MASTER BEDROOM | | DOUBLE DOORS AND NEW FAMILY ROOM SINGLE DOOR DON'T | | CORRESPOND TO THE EFFECTIVE WIND AREA SHOWN ON | | COMPONENTS AND CLADDING DESIGN PRESSURES ON SHEET 5.1. | | REVISE AS REQUIRED. SEE SIZE OF DOORS AND REVISE AS | | REQUIRED. | | | | RESPONSE: | | PARTIALLY ADDRESSED. THE DOUBLE DOORS ARE CORRECT BUT | | SINGLE DOOR IS NOT. THE LOADS FOR SINGLE DOOR "01" NEED | | TO BE REVISED. NEED TO USE DESIGN PRESSURES FOR THE | | LOWER EFFECTIVE AREA AS REQUIRED BY FOOTNOTE "B" OF | | TABLE R301.2(2)FBC-RESIDENTIAL. SEE TABLE FOR DESIGN | | PRESSURES OF 20S.F. EFFECTIVE WIND AREA AND REVISE AS | | REQUIRED. REMEMBER THAT DESIGN PRESSURES ON THIS TABLE | | NEED TO BE ADJUSTED WITH THE EXPOSURE AND HEIGHT | | COEFFICIENT OF TABLE R301.2(3) FBC-RESIDENTIAL. | | | | ORIGINAL COMMENT: | | B) GARAGE DOORS DESIGN PRESSURES SHOWN ON THE | | COMPONENTS AND CLADDING DESIGN PRESSURES ON SHEET 5.1 | | DON'T CORRESPOND TO THE ONES SHOWN ON TABLE 301.2(4) | | FBC-RESIDENTIAL WHEN MULTIPLIED BY THE COEFFICIENT FOR | | EXPOSURE "C". SEE TABLE R301.2(3) FBC-RESIDENTIAL AND | | REVISE AS REQUIRED. | | | | RESPONSE: | | REPEAT COMMENT. NOT ADDRESSED. | | | | 5- ENERGY CALCULATIONS SUBMITTED: | | ORIGINAL COMMENT: | | A) THE ENERGY FORM R405-2017 IS REQUIRED TO BE | | CERTIFIED AT THE BOTTOM BY THE OWNER OR OWNER'S LEGALLY | | DESIGNATED AGENT AS REQUIRED BY SEC. R103.1.1.2 | | FBC-ENERGY CONSERVATION, 6TH EDITION (2017). | | | | RESPONSE: | | REPEAT COMMENT. NOT ADDRESSED. | | | | B)OK. | | | | C) OK. | | | | D) OK. | | | | E) OK. | | | | ORIGINAL COMMENT: | | 6- ENGINEER OF RECORD TO SPECIFY ROOF TILE FASTENING IN | | THE CONSTRUCTION DOCUMENTS. SEC. 107.2.1.1 CITY | | AMENDMENTS. IF SPECIFYING ROOF TILE ADHESIVE, THEN | | SPECIFY PADDY SIZE AND PROVIDE PRODUCT APPROVAL. IF | | SPECIFYING SCREWS, THEN SPECIFY SCREW SIZE AND NUMBER | | OF SCREWS. | | | | RESPONSE: | | REPEAT COMMENT. NOT ADDRESSED. | | | | 7-PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.001 FOR: | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | SUBMITTAL. CONTRACTOR TO ADVICE IF SUBMITTING THIS | | INFORMATION LATER). | | | | ORIGINAL COMMENT: | | A)WINDOW MULLIONS AS SHOWN ON PLANS. AND REQUIRED: | | CLEARLY SPECIFY MULLION SIZE TO BE USED TO VERIFY | | COMPLIANCE WITH THE CALCULATED DESIGN PRESSURES. | | | | RESPONSE: | | REPEAT COMMENT. NOT ADDRESSED. | | | | ORIGINAL COMMENT: | | B)FIXED WINDOWS. PROVIDE FLORIDA PRODUCT APPROVAL COVER | | PAGE THAT CORRESPONDS TO DRAWINGS SUBMITTED. COVER PAGE | | SUBMITTED IS FOR MANY DIFFERENT PRODUCT APPROVAL | | NUMBERS. UNABLE TO IDENTIFY THE ONE THAT CORRESPONDS TO | | DRAWING SUBMITTED. | | | | RESPONSE: | | PARTIALLY DONE. PROVIDE COMPLETE INFORMATION. PROVIDE | | FLORIDA PRODUCT APPROVAL COVER PAGE THAT CORRESPONDS TO | | DRAWINGS SUBMITTED. SEC. 107.2.1 CITY AMENDMENTS. | | | | ORIGINAL COMMENT: | | C) ROOF TILE ADHESIVE IF SPECIFIED BY THE ENGINEER OF | | RECORD. SEE ROOF TILE NOA SUBMITTED FOR LISTED | | ADHESIVES. AND CLEARLY MARK PADDY SIZE AS REQUIRED BY | | CITY POLICY FOR ALL ROOFING PERMITS. | | | | RESPONSE: | | REPEAT COMMENT. NOT ADDRESSED. | | | | ORIGINAL COMMENT: | | D) DOUBLE DOORS AS SHOWN FOR NEW STORAGE. | | | | RESPONSE: | | REPEAT COMMENT. NOT ADDRESSED. | | | | 8- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | ABOVE PRODUCT APPROVALS AS REQUIRED BY SEC. 107.3.4.1 | | CITY AMENDMENTS | | | | 9- OK. | | | | 10- OK. | | | | NEW COMMENT: | | 11- ALL PLANS ON BOTH SETS NEED TO HAVE THE SEAL AND | | SIGNATURE OF THE ENGINEER OF RECORD AS REQUIRED BY | | CHAPTER 471 F.S. WHEN SUBMITTING PLANS/DOCUMENTS FOR | | PUBLIC RECORDS. | | | | | | 12- WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | PLEASE, INSERT CORRECTED PAGES INTO THE SUBMITTAL AND | | REMOVE/VOID THE PREVIOUSLY REVIEWED SHEETS. | | PLEASE DON'T STAPLE OLD DRAWINGS/DOCUMENTS . SUBMIT OLD | | DRAWINGS/DOCUMENTS FOR REFERENCE. | | | | RESPONSE: | | ORIGINAL PLANS AND SUBMITTALS (ENERGY CALCULATIONS) | | WERE NOT RE-SUBMITTED. IN THE FUTURE PLEASE RES-SUBMIT | | EVERYTHING THAT WAS REVIEWED IN ORDER TO USE THEM FOR | | REFERENCE AND EXPEDITE THE REVIEW PROCESS. | | | | EVEN THOUGH RESPONSE LETTER IS NOT MANDATORY IT IT'S | | VERY HELPFUL TO PROVIDE ONE IN ORDER TO TO EXPEDITE THE | | REVIEW PROCESS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2019-04-16 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-04-16 |
Time |
18:25 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-04-16 |
Time |
09:18 |
Sent To |
|
|
Notes |
2019-04-16 18:26:26 | RESIDENTIAL (R3) ADDITION/ALTERATION BUILDING REVIEW | | COMMENTS | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | 1- PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE | | FOLLOWING: | | SEC. R401.3 FBC-RESIDENTIAL (DRAINAGE). | | SEC. 107.2.5 CITY AMENDMENTS (SITE PLAN). | | SEC. 110.9 CITY AMENDMENTS (IMPACT OF CONSTRUCTION). | | | | 2- DESIGN PARAMETERS ON SHEET 3.1: | | A)ENGINEER OF RECORD IS SPECIFYING CONSTRUCTION TYPE | | IIIB. ACCORDING TO TABLE 601 FBC TYPE III CONSTRUCTION | | REQUIRES TWO HOURS FIRE RESISTANCE ON ALL EXTERIOR | | BEARING WALLS. PROVIDE COMPLETE DETAILS AND | | SPECIFICATIONS SHOWING HOW THE EXTERIOR WALLS PROVIDE 2 | | HOUR FIRE RATING. AND , PROVIDE MANUFACTURER'S | | SPECIFICATION FOR TWO HOUR FIRE RATED CONCRETE BLOCK. | | NOTE: TYPICALLY ONE AND TWO FAMILY STRUCTURES ARE | | CONSTRUCTION TYPE VB. CLARIFY WHY SPECIFYING | | CONSTRUCTION TYPE IIIB. | | | | B) ROOF LOADS ARE NOT CLEAR. DOES THE TOTAL ROOF LIVE | | INCLUDE THE TOP AND BOTTOM TRUSS CHORDS?. | | AND, DOES THE TOTAL ROOF DEAD LOAD INCLUDE THE TOP AND | | BOTTOM TRUSS CHORDS? ENGINEER OF RECORD TO CLARIFY. | | CLEARLY SPECIFY THE TOP AND BOTTOM LIVE AND DEAD CHORDS | | TO AVOID CONFLICTS/DELAYS. SEC. 107.2.1 CITY | | AMENDMENTS. | | | | 3- ENGINEER OF RECORD TO SPECIFY INSULATION ON WALL | | BETWEEN THE NEW MASTER BEDROOM AND NEW STORAGE AS | | REQUIRED BY SEC. R103.2 AND R103.2.1 FBC-ENERGY | | CONSERVATION. | | | | 4- A)DESIGN PRESSURES SHOWN FOR NEW MASTER BEDROOM | | DOUBLE DOORS AND NEW FAMILY ROOM SINGLE DOOR DON'T | | CORRESPOND TO THE EFFECTIVE WIND AREA SHOWN ON | | COMPONENTS AND CLADDING DESIGN PRESSURES ON SHEET 5.1. | | REVISE AS REQUIRED. SEE SIZE OF DOORS AND REVISE AS | | REQUIRED. | | | | B) GARAGE DOORS DESIGN PRESSURES SHOWN ON THE | | COMPONENTS AND CLADDING DESIGN PRESSURES ON SHEET 5.1 | | DON'T CORRESPOND TO THE ONES SHOWN ON TABLE 301.2(4) | | FBC-RESIDENTIAL WHEN MULTIPLIED BY THE COEFFICIENT FOR | | EXPOSURE "C". SEE TABLE R301.2(3) FBC-RESIDENTIAL AND | | REVISE AS REQUIRED. | | | | 5- ENERGY CALCULATIONS SUBMITTED: | | A) THE ENERGY FORM R405-2017 IS REQUIRED TO BE | | CERTIFIED AT THE BOTTOM BY THE OWNER OR OWNER?S LEGALLY | | DESIGNATED AGENT AS REQUIRED BY SEC. R103.1.1.2 | | FBC-ENERGY CONSERVATION, 6TH EDITION (2017). | | | | B)PROVIDE COMPLETE INFORMATION ON TOP OF FORM, | | INCLUDING BUILDER NAME. SEC. R101.5.1.1.2 FBC-ENERGY | | CONSERVATION. | | | | C) WALL TYPES ITEM #9 IS MISSING THE INFORMATION FOR | | THE WALL BETWEEN THE NEW MASTER BEDROOM AND THE NEW | | STORAGE. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. | | | | D) REVISE ROOF MATERIAL SPECIFIED ON PAGE 2 OF 4 TO | | MATCH PLANS AND PRODUCT APPROVAL SUBMITTED. THIS IS NOT | | SHINGLES. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. | | | | E) REVISE THE ATTIC VENT RATIO ON PAGE 2 OF 4. THE | | RATIO IS 1/150 NOT 1/300. SEE SEC. R806.2 | | FBC-RESIDENTIAL. OR, PERSON PREPARING THE ENERGY | | CALCULATIONS TO PROVIDE COMPLETE DOCUMENTATION SHOWING | | COMPLIANCE WITH THE 1/300 RATIO AS REQUIRED BY THE | | EXCEPTION ON SEC. R806.2. | | | | 6- ENGINEER OF RECORD TO SPECIFY ROOF TILE FASTENING IN | | THE CONSTRUCTION DOCUMENTS. SEC. 107.2.1.1 CITY | | AMENDMENTS. IF SPECIFYING ROOF TILE ADHESIVE, THEN | | SPECIFY PADDY SIZE AND PROVIDE PRODUCT APPROVAL. IF | | SPECIFYING SCREWS, THEN SPECIFY SCREW SIZE AND NUMBER | | OF SCREWS. | | | | 7-PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.001 FOR: | | A)WINDOW MULLIONS AS SHOWN ON PLANS. AND REQUIRED: | | CLEARLY SPECIFY MULLION SIZE TO BE USED TO VERIFY | | COMPLIANCE WITH THE CALCULATED DESIGN PRESSURES. | | | | B)FIXED WINDOWS. PROVIDE FLORIDA PRODUCT APPROVAL COVER | | PAGE THAT CORRESPONDS TO DRAWINGS SUBMITTED. COVER PAGE | | SUBMITTED IS FOR MANY DIFFERENT PRODUCT APPROVAL | | NUMBERS. UNABLE TO IDENTIFY THE ONE THAT CORRESPONDS TO | | DRAWING SUBMITTED. | | | | C) ROOF TILE ADHESIVE IF SPECIFIED BY THE ENGINEER OF | | RECORD. SEE ROOF TILE NOA SUBMITTED FOR LISTED | | ADHESIVES. AND CLEARLY MARK PADDY SIZE AS REQUIRED BY | | CITY POLICY FOR ALL ROOFING PERMITS. | | | | D) DOUBLE DOORS AS SHOWN FOR NEW STORAGE. | | | | 8- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS | | | | 9- PROVIDE SURVEY OR SITE PLAN SHOWING LOCATION OF | | ADDITION, PROPERTY LINES, SETBACKS AS REQUITED BY SEC. | | 107.3.5.3 CITY AMENDMENTS. | | | | 10- FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS AND | | SYSTEMS SHALL BE TOTAL REPLACEMENT VALUE TO INCLUDE | | STRUCTURAL, ELECTRIC, PLUMBING, MECHANICAL, INTERIOR | | FINISH, RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN | | FEES, MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING | | ONLY LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE | | LATEST PUBLISHED DATA OF NATIONAL CONSTRUCTION COST | | ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS | | PUBLISHED BY INTERNATIONAL CODE CONGRESS. VALUATION WAS | | UPDATED TO $241,657. THE PERMIT FEE BALANCE IS | | $4339.51. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | PLEASE, INSERT CORRECTED PAGES INTO THE SUBMITTAL AND | | REMOVE/VOID THE PREVIOUSLY REVIEWED SHEETS. | | PLEASE DON'T STAPLE OLD DRAWINGS/DOCUMENTS . SUBMIT OLD | | DRAWINGS/DOCUMENTS FOR REFERENCE. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2019-09-12 |
|
|
Cont ID |
|
Sent By |
ppetty |
Date |
2019-09-12 |
Time |
11:52 |
Rev Time |
0.00 |
Received By |
ppetty |
Date |
2019-09-12 |
Time |
11:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2019-07-31 |
|
|
Cont ID |
|
Sent By |
ppetty |
Date |
2019-07-31 |
Time |
13:04 |
Rev Time |
0.00 |
Received By |
ppetty |
Date |
2019-07-31 |
Time |
13:04 |
Sent To |
|
|
Notes |
2019-07-31 12:59:30 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. | | 2. | | 3.PROVIDE LOCATION OF METER AND MAINS ON PLAN NEC | | 230.72 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED ?OLD | | SHEETS?. | | | | SINCERELY, | | | | PHIL PETTY | | ELECTRICAL PLANS EXAMINER/CHIEF ELECTRICAL INSPECTOR | | 561-805-6742 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2019-06-18 |
|
|
Cont ID |
|
Sent By |
ppetty |
Date |
2019-06-18 |
Time |
11:07 |
Rev Time |
0.00 |
Received By |
ppetty |
Date |
2019-06-18 |
Time |
11:07 |
Sent To |
|
|
Notes |
2019-06-18 11:07:52 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1.OK | | 2.ELECTRICAL PLAN IS REQUIRED TO BE DESIGNED AND | | SIGNED/SEALED BY A DESIGN PROFESSIONAL OR THE | | ELECTRICAL CONTRACTOR QUALIFIER. PROVIDE CORRECTION. | | WPB FBC 107.1 | | 3.OK | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED ?OLD | | SHEETS?. | | | | SINCERELY, | | | | PHIL PETTY | | ELECTRICAL PLANS EXAMINER/CHIEF ELECTRICAL INSPECTOR | | 561-805-6742 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2019-04-04 |
|
|
Cont ID |
|
Sent By |
ppetty |
Date |
2019-04-04 |
Time |
11:14 |
Rev Time |
0.00 |
Received By |
ppetty |
Date |
2019-04-04 |
Time |
10:17 |
Sent To |
|
|
Notes |
2019-04-04 11:13:46 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1.PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | 2.ELECTRICAL PLAN IS REQUIRED TO BE DESIGNED AND | | SIGNED/SEALED BY A DESIGN PROFESSIONAL OR THE | | ELECTRICAL CONTRACTOR QUALIFIER. PROVIDE CORRECTION. FS | | 471.003(2)(H); 471.025; WPB FBC 107.15 | | 3.PROVIDE LOCATION OF METER AND MAINS ON PLAN NEC | | 230.72 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED ?OLD | | SHEETS?. | | | | SINCERELY, | | | | PHIL PETTY | | ELECTRICAL PLANS EXAMINER/CHIEF ELECTRICAL INSPECTOR | | 561-805-6742 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2019-09-23 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-09-23 |
Time |
18:52 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-09-20 |
Time |
15:03 |
Sent To |
I |
|
Notes |
2019-09-23 15:03:27 | ROUTED TO JGOMEZ |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2019-09-13 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2019-09-13 |
Time |
10:12 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2019-08-28 |
Time |
13:27 |
Sent To |
|
|
Notes |
2019-09-13 06:23:22 | TO HM DESK | | | 2019-08-29 13:27:58 | R13 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2019-08-20 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-08-20 |
Time |
18:28 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-07-29 |
Time |
16:01 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-06-20 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-06-20 |
Time |
16:45 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-05-28 |
Time |
10:24 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-04-16 |
|
|
Cont ID |
|
Sent By |
ppetty |
Date |
2019-04-16 |
Time |
18:30 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-03-11 |
Time |
14:46 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
4 |
Status |
P |
Date |
2019-09-23 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-09-23 |
Time |
18:52 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-09-23 |
Time |
18:41 |
Sent To |
|
|
Notes |
2019-09-23 18:52:38 | $417.24 PAID. MU-2019-028915 |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
3 |
Status |
F |
Date |
2019-08-20 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-08-20 |
Time |
13:29 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-08-20 |
Time |
13:29 |
Sent To |
|
|
Notes |
2019-08-20 13:29:47 | IMPACT FEES - PAPER SUBMITTALS | | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | (561) 233-5025. UPON APPROVAL OF PLANS, YOU MAY CHECK | | OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. | | PLEASE RETURNED STAMPED AND WITH A COPY OF THE RECEIPT | | AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
F |
Date |
2019-06-20 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-06-20 |
Time |
14:19 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-06-20 |
Time |
14:19 |
Sent To |
|
|
Notes |
2019-06-20 14:20:21 | IMPACT FEES - PAPER SUBMITTALS | | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | (561) 233-5025. UPON APPROVAL OF PLANS, YOU MAY CHECK | | OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. | | PLEASE RETURNED STAMPED AND WITH A COPY OF THE RECEIPT | | AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2019-04-16 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-04-16 |
Time |
18:30 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-04-16 |
Time |
18:26 |
Sent To |
|
|
Notes |
2019-04-16 18:30:14 | IMPACT FEES - PAPER SUBMITTALS | | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | (561) 233-5025. UPON APPROVAL OF PLANS, YOU MAY CHECK | | OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. | | PLEASE RETURNED STAMPED AND WITH A COPY OF THE RECEIPT | | AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2019-09-13 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2019-09-13 |
Time |
10:12 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2019-09-13 |
Time |
10:06 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2019-08-20 |
|
|
Cont ID |
|
Sent By |
cmontell |
Date |
2019-08-20 |
Time |
14:25 |
Rev Time |
0.00 |
Received By |
cmontell |
Date |
2019-08-20 |
Time |
14:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2019-06-17 |
|
|
Cont ID |
|
Sent By |
cmontell |
Date |
2019-06-17 |
Time |
13:46 |
Rev Time |
0.00 |
Received By |
cmontell |
Date |
2019-06-17 |
Time |
13:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2019-04-04 |
|
|
Cont ID |
|
Sent By |
cmontell |
Date |
2019-04-04 |
Time |
13:26 |
Rev Time |
0.00 |
Received By |
cmontell |
Date |
2019-04-04 |
Time |
13:23 |
Sent To |
|
|
Notes |
2019-04-04 13:26:48 | MECHANICAL PLAN REVIEW FAIL | | | | 1 - NEED RETURNS IN ALL BEDROOMS PER FBC RESIDENTIAL | | SEC M1602.3 BALANCED RETURN AIR., PLEASE PROVIDE SIZE | | FOR ALL FLEX DUCT AND RETURNS. | | | | | | CHRIS MONTELLO | | 805-6733 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2019-08-19 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2019-08-19 |
Time |
11:49 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2019-08-19 |
Time |
11:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2019-06-17 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2019-06-17 |
Time |
08:37 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2019-06-17 |
Time |
06:42 |
Sent To |
|
|
Notes |
2019-06-17 08:19:38 | PLUMBING 2ND REVIEW**DENIED**FL ST 553.80 (B)2B WITH | | RESPECT TO EVALUATION OF DESIGN PROFESSIONALS? | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. | | | | | | 1) 2ND REQUEST.PROVIDE WATER HEATER INSTALLATION | | MANUAL/ SPEC SHOWING THE EFFICIENCY RATING OF E.F .97 | | AS CALLED OUT IN THE R405 FORM. FBC 107.2.1. | | | | 2) 2ND REQUEST. PROVIDE A SHOWER DETAIL AND PROVIDE | | WHAT SHOWER PAN MATERIAL IS BEING USED. FBC 107.2.1 | | (A) FLOOR SHALL BE PRE-PITCH @ MIN 2% BEFORE SHOWER PAN | | MATERIAL IS INSTALLED. YOUR DETAIL ONLY SHOWS THE | | ACTUAL TILE BEING PITCHED @ 2%. FBC-R P2709.3 | | | | 3) 2ND REQUEST. PLUMBING ISOMETRIC DRAWING PROVIDE ON | | SHT. 7.1 HAS THE WASHING MACHINE AND LAUNDRY TUB | | DISCHARGING INTO THE BATHROOM GROUP WET VENT. FIXTURES | | OUTSIDE OF THE BATHROOM GROUP ARE NOT PERMITTED TO | | DISCHARGE INTO THE BATHROOM GROUPS HORIZONTAL WET VENT | | AND SHALL DISCHARGE DOWNSTREAM OF THE BATHROM GROUP. | | FBC-R P3108.1 | | | | 4) ALL SHEETS SHALL BE SIGN AND SEALED. F.S 471,481, | | | | | | TIM HUNT | | PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR | | CITY OF WEST PALM BEACH | | 561-248-2703 | | THUNT@CGA SOLUTIONS.COM | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2019-03-27 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2019-03-27 |
Time |
07:02 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2019-03-27 |
Time |
07:02 |
Sent To |
|
|
Notes |
2019-03-27 07:01:54 | PLUMBING 1ST REVIEW**DENIED** | | | | 1) PROVIDE WATER HEATER INSTALLATION MANUAL/ SPEC | | SHOWING THE EFFICIENCYRATING OF E.F .97 AS CALLED OUT | | IN THE R405 FORM. FBC 107.2.1. | | | | 2) PROVIDE A SHOWER DETAIL AND PROVIDE WHAT SHOWER PAN | | MATERIAL IS BEING USED. FBC 107.2.1 | | | | 3) PLUMBING ISOMETRIC DRAWING PROVIDE ON SHT. 7.1 HAS | | THE WASHING MACHINE AND LAUNDRY TUB DISCHARGING INTO | | THE BATHROOM GROUP WET VENT. FIXTURES OUTSIDE OF THE | | BATHROOM GROUP ARE NOT PERMITTED TO DISCHARGE INTO THE | | BATHROOM GROUPS HORIZONTAL WET VENT AND SHALL DISCHARGE | | DOWNSTREAM OF THE BATHROM GROUP. FBC-R P3108.1 | | | | | | TIM HUNT | | PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR | | CITY OF WEST PALM BEACH | | 561-248-2703 | | THUNT@CGA SOLUTIONS.COM | | | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
3 |
Status |
P |
Date |
2019-08-20 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-08-20 |
Time |
13:24 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-08-20 |
Time |
13:24 |
Sent To |
|
|
Notes |
2019-08-20 13:24:39 | PROVISO: | | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.001 FOR: | | A) ROOF TILE ADHESIVE IF SPECIFIED BY THE ENGINEER OF | | RECORD. SEE ROOF TILE NOA SUBMITTED FOR LISTED | | ADHESIVES. AND CLEARLY MARK PADDY SIZE AS REQUIRED BY | | CITY POLICY FOR ALL ROOFING PERMITS. | | | | B) RIDGE VENT AS SPECIFIED BY THE NEW ENGINEER OF | | RECORD ON PAGE 9.0 OF DRAWINGS SUBMITTED. | | | | 3- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS | | | | | | APPROVED ROOF TILE NOA 16-0112.07 | | | | | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
F |
Date |
2019-06-20 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-06-20 |
Time |
16:44 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-06-20 |
Time |
16:44 |
Sent To |
|
|
Notes |
2019-06-20 16:45:13 | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.001 FOR: | | A) ROOF TILE ADHESIVE IF SPECIFIED BY THE ENGINEER OF | | RECORD. SEE ROOF TILE NOA SUBMITTED FOR LISTED | | ADHESIVES. AND CLEARLY MARK PADDY SIZE AS REQUIRED BY | | CITY POLICY FOR ALL ROOFING PERMITS. | | | | B) | | | | 3- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | | | | | APPROVED ROOF TILE NOA 16-0112.07 | | | | | | | | | | 1- ENGINEER OF RECORD TO SPECIFY ROOF TILE FASTENING IN | | THE CONSTRUCTION DOCUMENTS. SEC. 107.2.1.1 CITY | | AMENDMENTS. IF SPECIFYING ROOF TILE ADHESIVE, THEN | | SPECIFY PADDY SIZE AND PROVIDE PRODUCT APPROVAL. IF | | SPECIFYING SCREWS, THEN SPECIFY SCREW SIZE AND NUMBER | | OF SCREWS. | | | | 2- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.001 FOR: | | A) ROOF TILE ADHESIVE IF SPECIFIED BY THE ENGINEER OF | | RECORD. SEE ROOF TILE NOA SUBMITTED FOR LISTED | | ADHESIVES. AND CLEARLY MARK PADDY SIZE AS REQUIRED BY | | CITY POLICY FOR ALL ROOFING PERMITS. | | | | 3- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | | | | | APPROVED ROOF TILE NOA 16-0112.07 |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2019-04-16 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-04-16 |
Time |
18:26 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-04-16 |
Time |
18:26 |
Sent To |
|
|
Notes |
2019-04-16 18:26:49 | 1- ENGINEER OF RECORD TO SPECIFY ROOF TILE FASTENING IN | | THE CONSTRUCTION DOCUMENTS. SEC. 107.2.1.1 CITY | | AMENDMENTS. IF SPECIFYING ROOF TILE ADHESIVE, THEN | | SPECIFY PADDY SIZE AND PROVIDE PRODUCT APPROVAL. IF | | SPECIFYING SCREWS, THEN SPECIFY SCREW SIZE AND NUMBER | | OF SCREWS. | | | | 2- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.001 FOR: | | A) ROOF TILE ADHESIVE IF SPECIFIED BY THE ENGINEER OF | | RECORD. SEE ROOF TILE NOA SUBMITTED FOR LISTED | | ADHESIVES. AND CLEARLY MARK PADDY SIZE AS REQUIRED BY | | CITY POLICY FOR ALL ROOFING PERMITS. | | | | 3- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | | | | | APPROVED ROOF TILE NOA 16-0112.07 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2019-08-29 |
|
|
Cont ID |
|
Sent By |
awooten |
Date |
2019-08-29 |
Time |
|
Rev Time |
0.00 |
Received By |
awooten |
Date |
2019-08-29 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2019-08-13 |
|
|
Cont ID |
|
Sent By |
awooten |
Date |
2019-08-13 |
Time |
|
Rev Time |
0.00 |
Received By |
awooten |
Date |
2019-08-13 |
Time |
|
Sent To |
|
|
Notes |
2019-08-13 15:15:46 | ***************************************ZONING REVIEW | | FAILED***************************************** | | | | THE STREET SIDE SETBACK ON OLIVE IS 12.5 FEET, SETBACK | | LINE ON SITE PLAN HAS 10 FEET. (THE PROPOSED SETBACK | | FOR THE ADDITION MEETS THE REQUIREMENT.) | | | | THE VALUE OF PROJECT TRIGGERS THE LANDSCAPE CODE. A | | SEPARATE LANDSCAPE AND IRRIGATION PERMIT IS REQUIRED. | | | | ALANA WOOTEN | | ASSOCIATE PLANNER | | PLANNING DIVISON | | 561-822-1449 | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2019-06-12 |
|
|
Cont ID |
|
Sent By |
awooten |
Date |
2019-06-12 |
Time |
|
Rev Time |
0.00 |
Received By |
awooten |
Date |
2019-06-12 |
Time |
|
Sent To |
|
|
Notes |
2019-06-12 15:08:54 | **************************************************ZONIN | | G REVIEW FAILED**************************************** | | ************ | | | | THE LANDSCAPE AND IRRIGATION PLAN SUBMITTED WITH THIS | | PERMIT HAS TO BE SUBMITTED AS A SEPARATE PERMIT. | | | | ALANA WOOTEN | | ASSOCIATE PLANNER | | PLANNING DIVISION | | [email protected] | | 561-822-1449 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2019-03-19 |
|
|
Cont ID |
|
Sent By |
awooten |
Date |
2019-03-19 |
Time |
|
Rev Time |
|
Received By |
awooten |
Date |
2019-03-19 |
Time |
|
Sent To |
|
|
Notes |
2019-03-19 14:37:14 | ********************************ZONING REVIEW | | FAILED********************************************** | | | | PLEASE PROVIDE A SITE PLAN WITH ADDITION AND SETBACKS. | | | | ADDITION IS MORE THAN HALF THE PROPERTY VALUE OF HOME, | | SO THE LANDSCAPE CODE HAS BEEN TRIGGERED. | | | | PLEASE SUBMIT A SEPARATE LANDSCAPE AND IRRIGATION | | PERMIT. SHOWING THE FOLLOWING: | | RESIDENTIAL LANDSCAPE REQUIREMENTS CITY OF WEST PALM | | BEACH | | SECTION 94-442(C)(2)A. SINGLE FAMILY DWELLING UNITS | | | | O GROSS LOT SQUARE FOOTAGE MINUS | | O BUILDING FOOTPRINT SQUARE FOOTAGE EQUALS | | O OPEN SPACE SQUARE FOOTAGE (ALL NON-BUILDING AREA) | | O ONE TREE REQUIRED FOR EACH 1,000 SQ FT OF OPEN SPACE | | OR PORTION THEREOF | | O ONE SHRUB REQUIRED FOR EACH 500 SQ FT OF OPEN SPACE | | OR PORTION THEREOF | | | | | | PLEASE DIMENSION THE OVERHANGS. THEY ARE NOT PERMITTED | | TO EXCEED 3 FEET. | | | | ALANA WOOTEN | | ASSOCIATE PLANNER | | PLANNING DIVISION | | 561-822-1449 | | [email protected] |
|
|