Plan Review Details - Permit 19030358
Plan Review Stops For Permit 19030358
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-06-21 Cont ID  
Sent By jgomez Date 2019-06-21 Time 16:04 Rev Time 0.00
Received By jgomez Date 2019-06-20 Time 10:00 Sent To  
Notes
2019-06-21 16:06:52THIS BUILDING REVIEW IS FOR APPROVAL OF VIBRO
 COMPACTION FOR APARTMENT BUILDING FOUNDATIONS ONLY AS
 RECOMMENDED BY THE GEO-TECHNICAL REPORT.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-04-16 Cont ID  
Sent By jwitmer Date 2019-04-16 Time 09:32 Rev Time 0.00
Received By jwitmer Date 2019-04-16 Time 09:27 Sent To  
Notes
2019-04-16 09:32:302017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 19030358 -CYAN APARTMENTS-
 VIBRO-COMPACTION FOR 7 STORY R-2 OCCUPANCY
 ADD: 1500 CENTREPARK BLVD.
 CONT: TBD/ TO BE DETERMINED
 TEL: 561-348-4805 CONTACT KARI NEVILLE
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 1ST REVIEW
 DATE: TUES. APRIL 16/ 2019
 ACTION: DENIED
  
 1) CONTRACTOR TO BE SIGNED ONTO THE PERMIT BEFORE
 PERMIT ISSUANCE CAN OCCUR. FLORIDA STATUTE 489.
  
 2) AAI FILE NO. 18-1735 MARCH 07/2019 FROM ARDAMAN AND
 ASSOCIATES STATES THAT THEIR FIRM WILL BE ONSITE TO
 MONITOR THE VIBRO-COMPACTION GROUND IMPROVEMENT PROGRAM
 AT THE SITE. THE SUBMITTED DOCUMENT WOULD APPEAR TO BE
 A PAPER DOCUMENT THAT WAS SCANNED AN UPLOADED. THE
 SIGNATURE AND SEAL ARE NOT AN ELECTRONIC SEAL NOR
 SIGNATURE. EITHER AN PAPER ORIGINAL WITH SEAL AND
 SIGNATURE WILL NEED TO BE FILED WITH THE CITY OR MEET
 THE REQUIREMENTS OF FLORIDA ADMINISTRATIVE CODE
 61G15-23.005 (3)(C).
 FLORIDA ADMINISTRATIVE CODE 61G15-23.005 (3)(C) A
 SCANNED, FACSIMILE, DIGITALLY CREATED OR COPIED IMAGE
 OF THE LICENSEE?S SIGNATURE SHALL NOT BE USED ON
 ELECTRONICALLY SIGNED AND SEALED ENGINEERING PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.
  
 3) THE SUBMITTED GEOTECHNICAL REPORT BY ARDAMAN &
 ASSOCIATES FILE NO. 18-1735 OCT. 23/ 2018 APPEARS TO BE
 A PAPER REPORT THAT WAS UPLOADED, THE REPORT DOES NOT
 HAVE ELECTRONIC SIGNATURES.
 FLORIDA ADMINISTRATIVE CODE 61G15-23.005 (3)(C) A
 SCANNED, FACSIMILE, DIGITALLY CREATED OR COPIED IMAGE
 OF THE LICENSEE?S SIGNATURE SHALL NOT BE USED ON
 ELECTRONICALLY SIGNED AND SEALED ENGINEERING PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.
  
 4) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2019-06-24 Cont ID  
Sent By rrossano Date 2019-06-24 Time   Rev Time 0.00
Received By rrossano Date 2019-06-24 Time   Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2019-04-30 Cont ID  
Sent By shill Date 2019-04-30 Time 07:42 Rev Time 0.00
Received By shill Date 2019-04-30 Time 07:42 Sent To  
Notes
2019-04-30 07:42:57CONTACT ENGINEERING DEPARTMENT DIRECTLY AND SUBMIT
 APPLICATION IF REQUIRED
 HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS
 /FORMS,-PERMITS-APPLICATIONS
  
 ENGINEERING APPROVAL REQUIRED PRIOR TO PERMIT ISSUANCE
  
 MAIN PHONE: (561) 822-1200

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-07-02 Cont ID  
Sent By lmarchan Date 2019-07-02 Time 16:33 Rev Time 0.00
Received By lmarchan Date 2019-05-28 Time 12:59 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-04-30 Cont ID  
Sent By shill Date 2019-04-30 Time 07:49 Rev Time 0.00
Received By shill Date 2019-03-18 Time 12:56 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2019-06-21 Cont ID  
Sent By shill Date 2019-06-21 Time 15:39 Rev Time 0.00
Received By shill Date 2019-06-21 Time 15:39 Sent To  
Notes
2019-06-21 15:40:23EMAILED [email protected]; ADVISED CIVIL
 ENGINEER THAT A 3RD PARTY SIGNATURE IS REQUIRED IN THE
 FUTURE
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2019-04-30 Cont ID  
Sent By shill Date 2019-04-30 Time 07:43 Rev Time 0.00
Received By shill Date 2019-04-30 Time 07:43 Sent To  
Notes
2019-04-30 07:44:12SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. THE GEOTECHNICAL ENGINEER'S REPORT AND VIBRO LETTER
 SUBMITTED ARE NOT DIGITALLY SIGNED.
  
 DOES THE ENGINEER HAVE A DIGITAL SIGNATURE? IF YES,
 PLEASE PROVIDE DIGITALLY SIGNED PLANS.
  
 IF HE DOES NOT, AFTER ALL REVIEWS HAVE PASSED, SUBMIT
 ONE ORIGINAL SIGNED AND SEALED PAPER SET TO THE
 BUILDING DIVISION.
  
 2. THE SRUCTURAL ENGINEER (J. EDUARDO GONZALEZ, PE) HAS
 A DIGITAL SIGNATURE WHICH LACKS THE LANGUAGE REQUIRED
 BY FAC61G15-23.004. PLEASE CORRECT.
  
  
2019-04-16 09:33:51SIGNATURES OF SOILS LETTER AND SOILS REPORT NOT
 ELECTRONIC. JW

Review Stop Z ZONING
Rev No 2 Status P Date 2019-07-02 Cont ID  
Sent By jroach Date 2019-07-02 Time 15:01 Rev Time 0.00
Received By jroach Date 2019-06-20 Time 09:58 Sent To  
Notes
2019-07-02 15:01:46THIS BUILDING REVIEW IS FOR APPROVAL OF VIBRO
 COMPACTION FOR APARTMENT BUILDING FOUNDATIONS ONLY.
  

Review Stop Z ZONING
Rev No 1 Status F Date 2019-04-23 Cont ID  
Sent By jroach Date 2019-04-23 Time 14:01 Rev Time 0.00
Received By jroach Date 2019-04-23 Time 14:01 Sent To  
Notes
2019-04-23 14:01:37ZONING PLAN REVIEW
 ___________________________________________
  
 DATE OF REVIEW: 04.23.2019
 PERMIT NO.: 19030358
 ___________________________________________
  
 REVIEW STATUS: FAILED
 ___________________________________________
  
 THE SCOPE OF THIS REVIEW IS LIMITED TO THE FOUNDATION
 OF THE BUILDING AND THE SURROUNDING SITE WORK. COMMENTS
 RELATING TO THE BUILDING WILL BE ISSUED SEPARATELY WITH
 THE BUILDING PERMIT REVIEW. PLEASE PROVIDE A WRITTEN
 RESPONSE TO THE FOLLOWING PLAN REVIEW COMMENTS:
  
 1. PLEASE CLARIFY WHY A DIFFERENT SITE PLAN WAS
 DEVELOPED FOR PERMITTING, AS OPPOSED TO USING THE SITE
 PLAN PREPARED BY SCHMIDT NICHOLS, WHICH WAS APPROVED BY
 THE CITY COMMISSION? THE SITE PLAN SUBMITTED FOR
 PERMITTING DOES NOT MATCH THAT WHICH WAS APPROVED AND A
 SIGNIFICANT AMOUNT OF INFORMATION IS NOW MISSING.
  
 2. PLEASE REMOVE THE LANDSCAPE PLANS FROM THE
 FOUNDATION PERMIT SUBMITTAL AS THE LANDSCAPE PLANS ARE
 TO BE SUBMITTED UNDER A SEPARATE PERMIT APPLICATION.
  
 3. PURSUANT TO RESOLUTION NO. 98-17 (CENTREPARK
 AFFORDABLE AND WORKFORCE HOUSING POLICY), THE DEVELOPER
 SHALL CONTRIBUTE $150 PER DWELLING UNIT TO THE CITY?S
 WORKFORCE HOUSING TRUST FUND UPON OBTAINING SITE PLAN
 APPROVAL. PLEASE PROVIDE PROOF THAT SUCH CONTRIBUTION
 HAS BEEN SATISFIED.
  
 4. CIVIL PLANS DO NOT REFLECT THE SCOPE OF WORK THAT IS
 REQUIRED WITHIN THE CENTREPARK DRIVE RIGHT-OF-WAY,
 INCLUDING THE PROVISION OF ON-STREET PARKING, PROTECTED
 BIKE LANE, ETC.
  
 5. THE CIVIL PLANS INDICATE THAT DRAINAGE IS OCCURRING
 OFF-SITE WITHIN THE CENTREPARK?S POA PARCEL LOCATED AT
 THE CORNER OF AUSTRALIAN AVENUE AND CENTREPARK DRIVE.
 PLEASE PROVIDE PROOF OF AN EASEMENT.
  
 6. THE FLOOR PLANS DO NOT MATCH THAT WHICH WAS APPROVED
 BY THE CITY COMMISSION (RESOLUTION NO. 22-19). ALL
 PLANS SUBMITTED FOR PERMITTING SHALL BE CONSISTENT WITH
 THE APPROVED PLANS. MODIFICATIONS TO THE APPROVED PLANS
 SHALL REQUIRE AN AMENDMENT TO THE CENTREPARK COMMERCIAL
 PLANNED DEVELOPMENT (CPD). ONE AREA OF SPECIFIC CONCERN
 IS THE FRONT STOOPS LEADING INTO THE GROUND FLOOR
 UNITS/ENTRANCES. STEPS/STOOPS ENCROACHING INTO THE
 SETBACK SHALL NOT EXCEED THREE (3) FEET IN HEIGHT.
 PLEASE CONFIRM THAT ALL STEPS/STOOPS ENCROACHING INTO
 THE SETBACK ARE LESS THAN THREE (3) FEET IN HEIGHT.
 ___________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ___________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
 E: [email protected]
  
 W: WPB.ORG
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved