Plan Review Details - Permit 19021254
Plan Review Stops For Permit 19021254
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-04-29 Cont ID  
Sent By jgomez Date 2019-04-29 Time 10:54 Rev Time 0.00
Received By jgomez Date 2019-04-29 Time 08:21 Sent To M
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-03-14 Cont ID  
Sent By jgomez Date 2019-03-14 Time 13:30 Rev Time 0.00
Received By jgomez Date 2019-03-14 Time 10:09 Sent To  
Notes
2019-03-14 13:31:21RESIDENTIAL (R3) BUILDING REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 1- PROPOSED WINDOWS ON REAR BEDROOM LOCATED NEXT TO THE
 REAR BATHROOM DON'T COMPLY WITH THE EGRESS
 REQUIREMENTS. SEC. 702.5 FBC-EXISTING BUILDING CODE.
 NOTE: ACCORDING TO GOGGLE STREET VIEW IT LOOKS LIKE
 THIS HOUSE USED TO HAVE HORIZONTAL SLIDING WINDOWS NOT
 SINGLE HUNG WINDOWS. REPLACEMENT OF HORIZONTAL SLIDING
 WINDOW TO TWO SINGLE HUNG WINDOWS SIZE SHOWN ON PLANS
 WILL REDUCE THE CLEAR OPENING SIZE. THEREFORE, THEY
 DON'T COMPLY. REVISE PLANS AS REQUIRED. REPLACE WINDOWS
 WITH THE LARGEST HORIZONTAL SLIDING WINDOWS SIZE THAT
 WILL FIT ON THE EXISTING OPENING OR MAKE OPENING LARGER
 TO INSTALL THE PROPOSED SINGLE HUNG WINDOW SIZE THAT
 MEETS THE EGRESS REQUIREMENTS.
  
 2- DESIGNER OF RECORD TO SPECIFY ON PLANS THE R-VALUE
 FOR THE EXTERIOR WALLS AND CEILING THAT FORM PART OF
 THE BUILDING THERMAL ENVELOPE AS REQUIRED BY SEC.
 R103.2 FBC-ENERGY CONSERVATION.
 NOTE: PLANS AND ENERGY CALCULATIONS TO BE COORDINATED
 TO AVOID CONFLICTS/DELAYS.
  
 3- REVISE ENERGY CALCULATIONS SUBMITTED:
 A)PROVIDE COMPLETE AND CORRECT INFORMATION ON TOP OF
 FORM. PERMIT OFFICE IS CITY OF WEST PALM BEACH NOT FT
 PIERCE. THIS JURISDICTION NUMBER IS 604700 NO 661100.
 PROVIDE THE NAME OF THE OWNER AND THE BUILDER. SEC.
 R101.5.1.1.2 FBC- ENERGY CONSERVATION.
  
 B) REVISE ITEM #1. THIS IS NOT NEW CONSTRUCTION. IT'S
 EXISTING. SEC. R101.5.1.1.2 FBC- ENERGY CONSERVATION.
  
 C)PROVIDE WINDOWS AND DOORS MANUFACTURER'S
 SPECIFICATIONS SHOWING THE U-FACTOR AND SHGC FACTOR
 SPECIFIED ON THE ENERGY CALCULATIONS ON ITEM #7 ON PAGE
 1 OF 4 AS REQUIRED BY SEC. R405.4.3 FBC-ENERGY
 CONSERVATION. NOTE: COORDINATE WITH PLANS AND PRODUCT
 APPROVALS SUBMITTED TO AVOID CONFLICTS/DELAYS.
  
 D)PROVIDE THE NAME OF PERSON PERFORMING THE ANALYSIS
 AND GENERATING THE REPORT AS REQUIRED BY SEC.
 R405.4.2.1 FBC- ENERGY CONSERVATION.
  
 E)REVISE THE DOORS INFORMATION SHOWN ON PAGE 3 OF 4 TO
 MATCH PLANS. REVISE ORIENTATION TO MATCH PLANS. SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 F) REVISE THE WINDOWS INFORMATION SHOWN ON PAGE 3 OF 4
 TO MATCH PLANS. REVISE ORIENTATION, FRAME MATERIAL,
 AREA AND OVERHANG DEPTH AND SEPARATION TO MATCH PLANS.
 SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 NOTE:
 LABEL FOR WINDOWS AND DOORS SHOWING THE U-FACTOR AND
 SHGC FACTOR IS REQUIRED WHEN THE ENERGY CALCULATIONS
 ARE NOT USING THE DEFAULT FACTOR.
  
 4- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20.3.001 FOR:
 A) WINDOW MULLIONS AS SHOWN ON PLANS. AND REQUIRED:
 CLEARLY SPECIFY MULLION SIZE TO BE USED TO VERIFY
 COMPLIANCE WITH THE CALCULATED DESIGN PRESSURES.
  
 B) SINGLE HUNG PRODUCT APPROVAL SUBMITTED IS
 INCOMPLETE. NEED TO PROVIDE COMPLETE FLORIDA PRODUCT
 APPROVAL (2 COPIES), INCLUDING THE FLORIDA PRODUCT
 APPROVAL COVER PAGE THAT CORRESPONDS TO THE DRAWINGS
 SUBMITTED. THE FLORIDA PRODUCT APPROVAL IS REQUIRED
 BECAUSE IT SHOWS IF PRODUCT IS APPROVED AND CURRENT
 CODE IN EFFECT.
  
 C) HORIZONTAL SLIDING WINDOW IF USED. COORDINATE WITH
 COMMENT #1 ABOVE.
  
 5- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 6- PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR
 REVISED MATERIALS MAY RESULT IN NEW PLAN REVIEW
 COMMENTS.
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 PLEASE, INSERT CORRECTED PAGES INTO THE SUBMITTAL AND
 REMOVE/VOID THE PREVIOUSLY REVIEWED SHEETS.
 PLEASE DON'T STAPLE OLD DRAWINGS/DOCUMENTS . SUBMIT OLD
 DRAWINGS/DOCUMENTS FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2019-05-06 Cont ID  
Sent By jpearson Date 2019-05-06 Time 10:19 Rev Time 0.00
Received By jpearson Date 2019-05-06 Time 10:19 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2019-04-18 Cont ID  
Sent By jpearson Date 2019-04-18 Time 08:40 Rev Time 0.00
Received By jpearson Date 2019-04-18 Time 08:40 Sent To B
Notes
2019-04-18 08:40:22CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS
 COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY
 HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW
 COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS.
  
 1. RISER DIAGRAM SHOWS A NEW 100 AMP PANEL BEING FED
 WITH # 8 CONDUCTORS. IT SEEMS THE PLAN IS INDICATING
 THIS TO BE A PARALLEL FEED TO THE PANEL, ALTHOUGH THE
 TERMINOLOGY FOR PARALLEL FEEDS IS MISSING. PER NEC,
 PARALLEL CONDUCTORS ARE PERMITTED ONLY IS SIZES 1/0 AND
 LARGER. THE # 8 CONDUCTORS SHOWN IS NOT RATED FOR 100
 AMPS, PROVIDE CORRECTION. NEC 310.10(H); FBC RE E3401.2
 (PANEL SCHEDULE STILL SHOWS # 8 WIRES ON A 100 AMP
 BREAKER, RISER DIAGRAM SHOWS # 4 WIRE, BUT ONLY TWO
 WIRES. BOTH OF THESE WIRE SIZES ARE NOT RATED FOR 100
 AMPS. THERE SHOULD BE A TOTAL OF 4 WIRES IN THE CONDUIT
 FEEDING THIS PANEL, INCLUDING 2 HOT WIRES, A NEUTRAL,
 AND AN EQUIPMENT GROUNDING CONDUCTOR. PROVIDE
 CORRECTION.)
 2. CORRECTED.
 3. CORRECTED.
 4. CORRECTED.
 5. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS
 LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND
 VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS
 IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. WPB FBC
 109.3 (NOT PROVIDED)
 6. CORRECTED.
  
 NEW COMMENT:
  
 7. WHEN NEW PLAN SHEETS ARE BROUGHT IN FOR REVIEW, THE
 OLD SHEETS SHOULD BE REMOVED FROM THE SET AND THEN THE
 NEW SHEETS INSTALLED IN THE SET SO THAT THERE ARE 2
 COMPLETE SET OF PLANS. PROVIDE CORRECTION. WPB FBC
 107.1
  
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-03-15 Cont ID  
Sent By jpearson Date 2019-03-15 Time 10:54 Rev Time 0.00
Received By jpearson Date 2019-03-15 Time 10:54 Sent To  
Notes
2019-03-15 10:53:56CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. RISER DIAGRAM SHOWS A NEW 100 AMP PANEL BEING FED
 WITH # 8 CONDUCTORS. IT SEEMS THE PLAN IS INDICATING
 THIS TO BE A PARALLEL FEED TO THE PANEL, ALTHOUGH THE
 TERMINOLOGY FOR PARALLEL FEEDS IS MISSING. PER NEC,
 PARALLEL CONDUCTORS ARE PERMITTED ONLY IS SIZES 1/0 AND
 LARGER. THE # 8 CONDUCTORS SHOWN IS NOT RATED FOR 100
 AMPS, PROVIDE CORRECTION. NEC 310.10(H); FBC RE E3401.2
 2. PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE,
 INCLUDE EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF
 SERVICE IS ADEQUATE. LOAD CALCULATION PROVIDED IS NOT
 COMPLIANT WITH FBC RE FORMAT AND IS ILLEGIBLE. NEC
 215.2, 220, 408.30; FBC RE E3602.2
 3. AFCI PROTECTION SHOWN IS NOT CODE COMPLIANT. ALL
 BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15-
 AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY
 ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES,
 DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS,
 HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS
 SHALL BE AFCI PROTECTED. THIS INCLUDES LIGHTING AND
 POWER OUTLETS AND RECEPTACLES. SOME AREAS REQUIRE BOTH
 AFCI AND GFCI PROTECTION. PROVIDE CORRECTION. NEC
 210.8, 210.12; FBC RE E3902; FBC EX 607.1.1 OR 801.1,
 801.2, OR 901.2 AS APPLICABLE.
 4. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC
 210.8(D); FBC RE E3902.10
 5. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS
 LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND
 VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS
 IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. WPB FBC
 109.3
 6. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED
 PER CODE. SMOKE ALARMS MUST BE INSTALLED AT LEAST 3
 FEET FROM BATHROOM DOOR, 3 FEET FROM CEILING FANS, AND
 3 FEET FROM ANY MECHANICAL DUCT. PROVIDE CORRECTIONS.
 FBC RE R314.3(4), R315.1, NFPA 72:29.8.3.4
  
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-04-29 Cont ID  
Sent By cmontell Date 2019-04-29 Time 12:41 Rev Time 0.00
Received By cmontell Date 2019-04-29 Time 12:41 Sent To  
Notes
2019-04-17 13:47:53RESUB ROUTED TO JPEARSON

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-03-16 Cont ID  
Sent By cmontell Date 2019-03-16 Time 07:20 Rev Time 0.00
Received By cmontell Date 2019-03-16 Time 07:20 Sent To  
Notes
2019-02-27 15:42:15R10

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2019-04-29 Cont ID  
Sent By cmontell Date 2019-04-29 Time 12:41 Rev Time 0.00
Received By cmontell Date 2019-04-29 Time 12:41 Sent To I
Notes
2019-04-29 09:05:04REVISED EQUIPMENT LOAD CALCULATIONS.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2019-03-16 Cont ID  
Sent By cmontell Date 2019-03-16 Time 07:20 Rev Time 0.00
Received By cmontell Date 2019-03-16 Time 07:08 Sent To I
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2019-03-11 Cont ID  
Sent By thunt Date 2019-03-11 Time 15:50 Rev Time 0.00
Received By thunt Date 2019-03-11 Time 15:24 Sent To  
Notes
***NONE***