|
 |
 |
 |
 |
 |
Plan Review Details - Permit 19020913
Plan Review Stops For Permit 19020913 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2019-03-18 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-03-18 |
Time |
08:59 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-03-18 |
Time |
08:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2019-03-15 |
|
|
Cont ID |
|
Sent By |
jduprey |
Date |
2019-03-15 |
Time |
10:33 |
Rev Time |
0.00 |
Received By |
jduprey |
Date |
2019-03-15 |
Time |
10:06 |
Sent To |
|
|
Notes |
2019-03-15 10:44:54 | BUILDING PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | JOSEAN A. DUPREY E.I., BN, PX | | BUILDING PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6716 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 2ND REVIEW | | RESULTS: DENIED | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. THE WINDOW LOAD CHART IS NOT SIGNED BY THE ENGINEER. | | PLEASE RE-SUBMIT WITH A VALID DIGITAL SIGNATURE. FBC | | 107 | | | | 2. THE GLASS TYPE INDICATED DO NOT MEET THE WIND LOAD | | PRESSURE REQUIRED ON THE WIND LOAD CHART. PLEASE HAVE | | THE ENGINEER SIGN THE WIND LOAD CHART AND INDICATE THE | | EXTERIOR WIND PRESSURE. THEN VERIFY THE PRODUCT AND | | GLASS TYPE SUBMITTED TO MEET THE REQUIRED EXTERIOR WIND | | PRESSURES. FBC 107 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2019-03-04 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-03-04 |
Time |
08:38 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-02-28 |
Time |
14:02 |
Sent To |
|
|
Notes |
2019-03-04 08:39:51 | BUILDING PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER, PX3169 | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | RESULTS: DENIED | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. SPECIFY GLASS TYPE ON NOA 17-0731.06 TO DETERMINE | | WIND LOADS. | | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | OFFICIAL. | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-03-15 |
|
|
Cont ID |
|
Sent By |
jduprey |
Date |
2019-03-15 |
Time |
10:46 |
Rev Time |
0.00 |
Received By |
jduprey |
Date |
2019-03-11 |
Time |
11:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-03-04 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-03-04 |
Time |
08:42 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-02-20 |
Time |
15:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2019-03-18 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-03-18 |
Time |
08:59 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-03-18 |
Time |
08:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2019-03-15 |
|
|
Cont ID |
|
Sent By |
jduprey |
Date |
2019-03-15 |
Time |
10:45 |
Rev Time |
0.00 |
Received By |
jduprey |
Date |
2019-03-15 |
Time |
10:45 |
Sent To |
|
|
Notes |
2019-03-15 10:45:44 | BUILDING PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | JOSEAN A. DUPREY E.I., BN, PX | | BUILDING PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6716 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | RESULTS: DENIED | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. THE WINDOW LOAD CHART IS NOT SIGNED BY THE ENGINEER. | | PLEASE RE-SUBMIT WITH A VALID DIGITAL SIGNATURE. FBC | | 107 | | | | 2. THE GLASS TYPE INDICATED DO NOT MEET THE WIND LOAD | | PRESSURE REQUIRED ON THE WIND LOAD CHART. PLEASE HAVE | | THE ENGINEER SIGN THE WIND LOAD CHART AND INDICATE THE | | EXTERIOR WIND PRESSURE. THEN VERIFY THE PRODUCT AND | | GLASS TYPE SUBMITTED TO MEET THE REQUIRED EXTERIOR WIND | | PRESSURES. FBC 107 | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2019-03-04 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-03-04 |
Time |
08:39 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-02-28 |
Time |
14:03 |
Sent To |
|
|
Notes |
2019-03-04 08:42:20 | BUILDING PLAN REVIEW - DIGITAL SIGNATURES | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER, PX3169 | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | RESULTS: DENIED | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | SIGNATURE AND SEAL ON ENGINEERING IS NOT VALID. | | | | 1. DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH | | FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE | | NEXT REVIEW CYCLE REQUIRE REVIEW. | | | | 2. UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL | | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE | | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT. | | | | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |