Plan Review Details - Permit 19020913
Plan Review Stops For Permit 19020913
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2019-03-18 Cont ID  
Sent By cthroop Date 2019-03-18 Time 08:59 Rev Time 0.00
Received By cthroop Date 2019-03-18 Time 08:56 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2019-03-15 Cont ID  
Sent By jduprey Date 2019-03-15 Time 10:33 Rev Time 0.00
Received By jduprey Date 2019-03-15 Time 10:06 Sent To  
Notes
2019-03-15 10:44:54BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 JOSEAN A. DUPREY E.I., BN, PX
 BUILDING PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6716
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 2ND REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
  
 1. THE WINDOW LOAD CHART IS NOT SIGNED BY THE ENGINEER.
 PLEASE RE-SUBMIT WITH A VALID DIGITAL SIGNATURE. FBC
 107
  
 2. THE GLASS TYPE INDICATED DO NOT MEET THE WIND LOAD
 PRESSURE REQUIRED ON THE WIND LOAD CHART. PLEASE HAVE
 THE ENGINEER SIGN THE WIND LOAD CHART AND INDICATE THE
 EXTERIOR WIND PRESSURE. THEN VERIFY THE PRODUCT AND
 GLASS TYPE SUBMITTED TO MEET THE REQUIRED EXTERIOR WIND
 PRESSURES. FBC 107
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-03-04 Cont ID  
Sent By cthroop Date 2019-03-04 Time 08:38 Rev Time 0.00
Received By cthroop Date 2019-02-28 Time 14:02 Sent To  
Notes
2019-03-04 08:39:51BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. SPECIFY GLASS TYPE ON NOA 17-0731.06 TO DETERMINE
 WIND LOADS.
  
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL.
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-03-15 Cont ID  
Sent By jduprey Date 2019-03-15 Time 10:46 Rev Time 0.00
Received By jduprey Date 2019-03-11 Time 11:28 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-03-04 Cont ID  
Sent By cthroop Date 2019-03-04 Time 08:42 Rev Time 0.00
Received By cthroop Date 2019-02-20 Time 15:19 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2019-03-18 Cont ID  
Sent By cthroop Date 2019-03-18 Time 08:59 Rev Time 0.00
Received By cthroop Date 2019-03-18 Time 08:57 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2019-03-15 Cont ID  
Sent By jduprey Date 2019-03-15 Time 10:45 Rev Time 0.00
Received By jduprey Date 2019-03-15 Time 10:45 Sent To  
Notes
2019-03-15 10:45:44BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 JOSEAN A. DUPREY E.I., BN, PX
 BUILDING PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6716
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
  
 1. THE WINDOW LOAD CHART IS NOT SIGNED BY THE ENGINEER.
 PLEASE RE-SUBMIT WITH A VALID DIGITAL SIGNATURE. FBC
 107
  
 2. THE GLASS TYPE INDICATED DO NOT MEET THE WIND LOAD
 PRESSURE REQUIRED ON THE WIND LOAD CHART. PLEASE HAVE
 THE ENGINEER SIGN THE WIND LOAD CHART AND INDICATE THE
 EXTERIOR WIND PRESSURE. THEN VERIFY THE PRODUCT AND
 GLASS TYPE SUBMITTED TO MEET THE REQUIRED EXTERIOR WIND
 PRESSURES. FBC 107
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2019-03-04 Cont ID  
Sent By cthroop Date 2019-03-04 Time 08:39 Rev Time 0.00
Received By cthroop Date 2019-02-28 Time 14:03 Sent To  
Notes
2019-03-04 08:42:20BUILDING PLAN REVIEW - DIGITAL SIGNATURES
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 SIGNATURE AND SEAL ON ENGINEERING IS NOT VALID.
  
 1. DIGITAL SIGNATURES/SEALS ARE NOT IN ACCORDANCE WITH
 FS 471, FS 481 AS NOTED. NEW SHEETS SUBMITTED IN THE
 NEXT REVIEW CYCLE REQUIRE REVIEW.
  
 2. UPLOAD VIA THE PROJECTDOX PORTAL WITH DIGITAL
 SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE
 THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT.
  
  
  