Plan Review Details - Permit 19020860
Plan Review Stops For Permit 19020860
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-03-05 Cont ID  
Sent By jduprey Date 2019-03-05 Time 16:16 Rev Time 0.00
Received By jduprey Date 2019-03-05 Time 16:16 Sent To  
Notes
2019-03-05 16:17:33ADJUSTED VALUE TO $26,180

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-02-28 Cont ID  
Sent By jduprey Date 2019-02-28 Time 13:48 Rev Time 0.00
Received By jduprey Date 2019-02-28 Time 13:46 Sent To  
Notes
2019-02-28 13:51:49BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 JOSEAN A. DUPREY E.I., BN, PX
 BUILDING PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6716
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. THE STATED VALUE APPEARS LOW FOR THE PROPOSED SCOPE
 OF WORK. THE PERMIT VALUATION AND PERMIT FEE MUST BE
 COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED
 CONTRACTOR WOULD PROVIDE. YOU MAY PROVIDE A COPY OF THE
 CONTRACT SIGNED BY THE OWNER OR A LIST OF LABOR,
 MATERIALS AND EQUIPMENT RENTAL TO VERIFY VALUE. CITY OF
 WPB CHAPTER 109.3
  
 2. PLEASE SPECIFY HOW MAY TRASH RECEPTACLES ARE? FBC
 107

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2019-02-22 Cont ID  
Sent By rrossano Date 2019-02-22 Time   Rev Time 0.00
Received By rrossano Date 2019-02-22 Time   Sent To B
Notes
2019-02-22 07:31:02PASSED WITH PROVISOS:
  
 THE OPENING OF THE DUMPSTER ENCLOSURE MUST BE ANGLED SO
 THAT A 40 FT. LONG SANITATION TRUCK WITH THE FORKS
 EXTENDED CAN APPROACH THE OPENING AND PICK UP THE
 DUMPSTER WITHOUT MAKING A SHARP TURN OR A 3 POINT TURN.
  
 THE SANITATION TRUCK NEEDS TO HAVE NO LESS THAN 16 FT.
 HIGH VERTICAL CLEARANCE AREA FOR THE TRUCK TO PICK UP
 THE DUMPSTER. THIS IS THE CLEAR AREA OVER THE DUMPSTER
 AND WHERE THE TRUCK WILL BE STOPPED TO UNLOAD THE
 DUMPSTER.
  
 THE SANITATION TRUCK NEEDS TO HAVE NO LESS THAN 14 FT.
 HIGH VERTICAL CLEARANCE AND 12 FT. HORIZONTAL
 CLEARANCES FOR THE TRUCKS TO DRIVE THROUGH.
  
 IT IS STRONGLY SUGGESTED THAT YOU ADD A RECYCLING
 CENTER TO YOUR DUMPSTER ENCLOSURE.
  
 NO FLOOR DRAIN TO THE SANITARY SEWER CAN BE INSTALLED
 IN THE DUMPSTER ENCLOSURE, UNLESS IT IS ROOFED SO NO
 RAIN WATER WILL GET INTO THE DRAIN.
  
 THE DUMPSTER ENCLOSURE MUST BE LOCATED TO ALLOW THE
 SANITATION TRUCK TO BACK UP NO MORE THAN 50 FT.
 STRAIGHT BACK AFTER THE RESETTING OF THE DUMPSTER IN
 THE ENCLOSURE.
  
 DUMPSTER LOADING AREA SHALL HAVE 10' CONCRETE SURFACE
 FOR TRUCK TO APPROACH. TYPICALLY ASPHALT IS USED IN THE
 AREA APPROACHING THE DUMPSTER AND IT QUICKLY
 DETERIORATES DUE TO THE FRONT WHEELS OF THE SANITATION
 VEHICLE.
  
 THERE ARE WATER AND SEWER LINES IN THE VICINITY OF THIS
 PROJECT. PER CHAPTER 556 OF THE FLORIDA STATE STATUTES,
 YOU MUST CALL 811 FOR UTILITY LOCATES AT LEAST TWO FULL
 BUSINESS DAYS IN ADVANCE OF ANY CONSTRUCTION OR
 DEMOLITION WORK. MORE INFORMATION CAN BE FOUND HERE:
 HTTP://WWW.SUNSHINE811.COM/
  
 PLEASE SEE THE ENCLOSED LINK FOR A COPY OF THE CITY OF
 WEST PALM BEACH GENERAL CONSTRUCTION STANDARD DETAIL
 FOR DUMPSTER ENCLOSURES (GC-8). HTTP://WWW.WPB.ORG/DEPA
 RTMENTS/ENGINEERING-PUBLIC-WORKS/FORMS,-PERMITS-APPLICA
 TIONS
  
 FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR
 CONCERNS, THANKS.
  
 RICK ROSSANO
 PROJECT COORDINATOR
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1098
 FAX: (561) 494-1116
 MOBILE: (561) 246-9525
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
 MANNY GONZALEZ
 SENIOR ENGINEERING PROJECT COORDINATOR
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 MOBILE: (561) 644-7301
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
 CENTRAL OPERATIONS CENTER (DISPATCH):
 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC
 UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-03-05 Cont ID  
Sent By jduprey Date 2019-03-05 Time 16:19 Rev Time 0.00
Received By jduprey Date 2019-03-05 Time 16:16 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-02-28 Cont ID  
Sent By jduprey Date 2019-02-28 Time 13:51 Rev Time 0.00
Received By jduprey Date 2019-02-19 Time 16:08 Sent To  
Notes
2019-02-20 16:09:04ROUTED TO ZONING INBOX

Review Stop Z ZONING
Rev No 1 Status P Date 2019-02-21 Cont ID  
Sent By mcruz Date 2019-02-21 Time 11:18 Rev Time 0.00
Received By mcruz Date 2019-02-21 Time 10:38 Sent To ENG
Notes
2019-02-21 11:17:59ZONING PASSED WITH PROVISO: WALLS MUST BE LANDSCAPED
 WITH SHRUBS AND HEDGES PLANTED AT TWO (2) FEET
 INTERVALS - ON ALL ENCLOSURES.
  
 MAGGIE CRUZ
 ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: 561-822-1442
 E-MAIL: [email protected]