Plan Review Details - Permit 19020586
Plan Review Stops For Permit 19020586
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2019-08-02 Cont ID  
Sent By rmcdouga Date 2019-08-02 Time 09:53 Rev Time 0.00
Received By dbattles Date 2019-08-02 Time 09:53 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2019-06-14 Cont ID  
Sent By dbattles Date 2019-06-13 Time 16:54 Rev Time 0.00
Received By dbattles Date 2019-06-13 Time 16:54 Sent To  
Notes
2019-06-14 08:25:31DYLAN BATTLES
 BUILDING PLANS EXAMINER PX4191
  
 FL.STATUTE 553.842
 PRODUCT APPROVALS
 PLEASE PRINT OUT COVER SHEETS FOR WINDOWS, SLIDERS AND
 MULL.
 THE DRAWINGS PROVIDED HAVE NO INDICATION OF THE PRODUCT
 APPROVAL NUMBER.
 I WOULD HAVE PRINTED THEM HERE, BUT THE PRODUCT
 APPROVAL NUMBERS SHOW ON SHEET 1 DONT MATCH THE PRODUT
 APPROVALS PROVIDED.
 YOU DON'T NEED TO UPDATE SHEET 1 AS LONG AS THE PRODUCT
 APPROVALS HAVE THEIR RESPECTIVE APPROVAL NUMBER
 PROVIDED.
  
 THE FIBERGLASS DOOR, GARAGE DOOR AND ROOFING ARE OK,
 ITS JUST THE WINDOWS, SLIDER AND MULL FROM MI WINDOWS
 THAT NEED COVERS.
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER PX4191
  
 PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F
 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-03-12 Cont ID  
Sent By dbattles Date 2019-03-12 Time 14:05 Rev Time 0.00
Received By dbattles Date 2019-03-08 Time 13:44 Sent To  
Notes
2019-03-12 14:05:42****CORRECTIONS****
 W.P.B. PERMIT: 19020586
 REVIEWED: MARCH 12, 2019
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER PX4191
 [email protected]
 561-805-6718
  
 FBC[AMENDED] = FLORIDA BUILDING CODE,6TH EDITION (2017)
 FBC[A] = FBC ACCESSIBILITY
 FBC[E] = FBC ENERGY CONSERVATION
 FBC[R] = FBC RESIDENTIAL
  
 1) 109.3 FBC[AMENDED] PROVIDE COPY OF PROPOSAL WITH
 CONTRACTOR TO SHOW WORK VALUE EQUAL TO THE AMOUNT SHOWN
 ON PERMIT APPLICATION, OR ADJUST VALUE TO MATCH ACTUAL
 COST OF WORK. PLEASE ADJUST FEE AT FRONT DESK AND PAY
 ADJUSTED PERMIT REVIEW FEE AT TIME OF RE-SUBMITTAL.
  -VALUE WAS CHECKED AGAINST CURRENT ICC BUILDING
 VALUATION DATA AND THE PROPOSED VALUE APPEARS LOW.
 PLEASE PROVIDE COST ESTIMATE, OR CALL/E-MAIL TO DISCUSS
 THE VALUATION OF CONSTRUCTION.
  
 2)103.1.1.2 FBC[RE] THE BUILDINGS OWNER, THE OWNERS
 ARCHITECT OR OTHER AUTHORIZED AGENT LEGALLY DESIGNATED
 BY THE OWNER SHALL CERTIFY THAT THE BUILDING IS IN
 COMPLIANCE WITH THE CODE, AS PER SECTION 553.907,
 FLORIDA STATUTES, PRIOR TO RECEIVING THE PERMIT TO
 BEGIN CONSTRUCTION OR RENOVATION. 553.907, FLORIDA
 STATUTES.
  -PLEASE HAVE THE OWNER SIGN THE ENERGY CALCULATIONS.
  
 3) 107.3.5 FBC[R] THE ENERGY CALCS SHOWS CEILING TYPE
 UNDER ATTIC AT 1859 SQ, FT. (VENTED) 1859 SQ. FT. IS
 THE TOTAL AREA UNDER AIR ACCORDING TO SHEET NUMBER 3 OF
 9. SINCE THIS IS TWO STORY AND THE SPACE BETWEEN FLOORS
 ISNT VENTED, ATTIC (VENTED) SHOULD ONLY INCLUDE SECOND
 FLOOR ATTIC SPACE. THE ATTIC AREA IS PROVIDED ON SHEET
 5 OF 9. PLEASE ADJUST ENERGY CALCULATIONS AS NEEDED.
  -ALSO, THE PLANS ARE CALLING FOR BATTS AND THE ENERGY
 CALCULATIONS ARE BASED ON BLOWN IN.
  
 4) 301.4 FBC[R] DEAD LOAD. THE ACTUAL WEIGHTS OF
 MATERIALS AND CONSTRUCTION SHALL BE USED FOR
 DETERMINING DEAD LOAD WITH CONSIDERATION FOR THE DEAD
 LOAD OF FIXED SERVICE EQUIPMENT.
  -PLEASE PROVIDE LIVE AND DEAD LOADS TO DESIGN DATA FOR
 ROOF, ATTIC AND FLOORS.
  
 5) 311.2 FBC[R] NOT LESS THAN ONE EGRESS DOOR SHALL BE
 PROVIDED FOR EACH DWELLING UNIT. THE EGRESS DOOR SHALL
 BE SIDE-HINGED, AND SHALL PROVIDE A CLEAR WIDTH OF NOT
 LESS THAN 32 INCHES WHERE MEASURED BETWEEN THE FACE OF
 THE DOOR AND THE STOP, WITH THE DOOR OPEN 90 DEGREES.
 THE CLEAR HEIGHT OF THE DOOR OPENING SHALL BE NOT LESS
 THAN 78 INCHES IN HEIGHT MEASURED FROM THE TOP OF THE
 THRESHOLD TO THE BOTTOM OF THE STOP. OTHER DOORS SHALL
 NOT BE REQUIRED TO COMPLY WITH THESE MINIMUM
 DIMENSIONS. EGRESS DOORS SHALL BE READILY OPENABLE FROM
 INSIDE THE DWELLING WITHOUT THE USE OF A KEY OR SPECIAL
 KNOWLEDGE OR EFFORT.
  -CHECK CLEAR SPACE AT ENTRY DOOR SINCE IT CAN'T SWING
 ALL THE WAY OPEN.
  
 6) 302.5.3 FBC[R] OTHER PENETRATIONS. PENETRATIONS
 THROUGH THE SEPARATION REQUIRED IN SECTION R302.6 SHALL
 BE PROTECTED AS REQUIRED BY SECTION R302.11, ITEM 4.
  -DRYWALL IN GARAGE WITH HABITABLE ROOM ABOVE NEED TO
 USE NOT LESS THAN 5/8 TYPE X GYPSUM OR EQUIVALENT. SEE
 TABLE 302.6 AND ADD NOTE IN PLANS.
  
 7) 107.3.5.3 FBC[AMENDED] PROVIDE SEDIMENT CONTROL TO
 KEEP CONSTRUCTION DEBRIS FROM ENTERING ADJACENT
 PROPERTIES AND STORM DRAINS DURING CONSTRUCTION. YOU
 CAN JUST ADD SILT FENCE DETAIL AND HOW DRAINS ARE
 PROTECTED TO THE DRAINAGE PLAN. SOME ENGINEERING
 STANDARD DETAILS CAN BE USED FROM WPB WEBSITE-POLLUTION
 CONTROL. HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUB
 LIC-WORKS/FORMS,-PERMITS-APPLICATIONS
  
 8) [FBC 107.5][FBC 110.9][FBC R401.3][PROVIDE SITE
 DRAINAGE PLAN. SURFACE DRAINAGE SHALL BE DIVERTED TO A
 STORM SEWER CONVEYANCE OR OTHER APPROVED POINT OF
 COLLECTION THAT DOES NOT CREATE A HAZARD. LOTS SHALL BE
 GRADED TO DRAIN SURFACE WATER AWAY FROM FOUNDATION
 WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 INCHES
 WITHIN THE FIRST 10 FEET. EXCEPTION: WHERE LOT LINES,
 WALLS, SLOPES OR OTHER PHYSICAL BARRIERS PROHIBIT 6
 INCHES OF FALL WITHIN 10 FEET (3048 MM), DRAINS OR
 SWALES SHALL BE CONSTRUCTED TO ENSURE DRAINAGE AWAY
 FROM THE STRUCTURE. IMPERVIOUS SURFACES WITHIN 10 FEET
 OF THE BUILDING FOUNDATION SHALL BE SLOPED A MINIMUM OF
 2 PERCENT AWAY FROM THE BUILDING.
  
 9) 703.4 FBC[R] PROVIDE TYPE OF WINDOW/DOOR FLASHING TO
 BE USED TO MEET REQUIREMENTS OF R703.4
  
 10) 301.6 FBC[R] ROOF LOAD. THE ROOF SHALL BE DESIGNED
 FOR THE LIVE LOAD INDICATED IN TABLE R301.6
  
 11) 107.3.4.1 FBC[AMENDED] PRODUCT APPROVAL.
  -PRODUCT APPROVAL FOR FIBERGLASS DOOR IS FL-15225.5
 AND THE TABLE ON SHEET 4 OF 9 AND 12 OF 9 HAS
 CONFLICTING PRODUCT APPROVAL NUMBER. PLEASE ADJUST LIST
 TO MATCH PROVIDED, OR REMOVE THE TABLE ON SHEET 4 OF 9
  
 12) 107.3.5 FBC[R] THE WINDOW MULL (HORIZONTAL AND
 VERTICAL), SINGLE HUNG, SLIDING DOOR AND FIXED WINDOW.
 THERE ARE NO EVALUATION REPORTS ON THESE PRODUCT
 APPROVALS AND THEY DON'T MATCH THE NUMBERS PROVIDED ON
 SHEET 4 OF 9 AND 1 OF 9.
  -PLEASE PROVIDE THE EVALUATION REPORTS FOR THESE AND
 PUT THE CURRENT PRODUCT APPROVAL ON THEM BECAUSE THE
 INSTALLATION INSTRUCTIONS PROVIDED ONLY HAVE OLD
 DRAWING NUMBERS AND DO NOT REFERENCE CURRENT NUMBERS.
  
 13) 107.3.4.1 FBC[AMENDED] SUBMIT TRUSS SHOP DRAWINGS
 TO THE BUILDING INSPECTOR PRIOR TO INSTALLATION.
  -THIS WILL BE A DEFERRED SUBMITTAL. THE TRUSS PACKAGE
 NEEDS TO BE REVIEWED BY BUILDING INSPECTOR PRIOR TO
 INSTALLATION.
  
 14) 107.2.1.2 FBC[AMENDED] PROVIDE STAIRCASE AND GUARD
 RAIL ENGINEERING, OR INDICATE THAT IT WILL BE
 DEFERRED.
  
 NOTES:
  
 -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
  
 -COMMENTS ARE A BRIEF OVERVIEW OF CODE SECTIONS.
 FURTHER REVIEW OF THE REFERENCED CODE SECTIONS WILL BE
 REQUIRED.
  
 -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW
 OF MATERIALS REQUESTED.
  
 -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS
 OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS)
 SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT
 DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER
 SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID"
 OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS
 APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE
 NEED "VOID", RENDERING THEM NOT USABLE.
  
 PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F
 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME
 [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-07-02 Cont ID  
Sent By jleahy Date 2019-07-02 Time 12:58 Rev Time 0.00
Received By jleahy Date 2019-07-02 Time 12:58 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-03-06 Cont ID  
Sent By jpearson Date 2019-03-06 Time 10:53 Rev Time 0.00
Received By jpearson Date 2019-03-06 Time 06:45 Sent To  
Notes
2019-03-06 10:53:51CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PER THE WPB AMENDMENTS TO THE FBC, PLAN (EACH SHEET
 OF BOTH COPIES) IS REQUIRED TO BEAR THE NAME AND BE
 SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE
 DESIGN. A DIGITAL SIGNATURE ON A PAPER PLAN IS NOT
 ACCEPTABLE. PROVIDE CORRECTION. WPB FBC 107.1, 107.2;
 FS 471, 481
 2. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR
 SERVICE INCLUDING INFORMATION FROM THE POWER COMPANY
 STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR
 THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE
 SERVICE EQUIPMENT IS ADEQUATE. NEC 110.9, 110.10; FBC
 RE E3606.3
 3. PROVIDE AIC RATING OF SERVICE PANEL. NEC 110.3,
 110.9; FBC RE E3606.3
 4. PROVIDE COMPLIANCE: A MINIMUM OF 75 PERCENT OF THE
 LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF
 THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 CONTAIN ONLY HIGH EFFICACY LAMPS. A NOTE WILL SUFFICE.
 FBC EC C405.1, R404.1
 5. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT
 SERVICE. SHOW ON PLAN. NEC 250.94; FBC RE E3609.3
 6. PROVIDE LOCATION OF ELECTRICAL SERVICE AND
 ELECTRICAL PANEL ON PLAN TO CONFIRM CODE COMPLIANCE.
 WPB FBC 107.2.1
 7. PLAN DOES NOT SHOW THE SMOKE ALARM REQUIRED ON FIRST
 FLOOR. PROVIDE CORRECTION TO CONFIRM CODE COMPLIANCE.
 FBC RE R314.3; WPB FBC 107.2.1
 8. LIGHTING IN BATHTUB OR SHOWER AREAS SHALL BE
 SUITABLE FOR DAMP LOCATIONS. PROVIDE CORRECTION FOR
 BATH 2. NEC 410.10(D); FBC RE E4003.11
 9. LIGHTING IN CLOSETS APPEARS TO BE STANDARD RECESS
 LIGHTS. PER CODE, LIGHTING WITH OPEN OR PARTIALLY
 ENCLOSED LAMPS AND PENDANT LUMINAIRES OR LAMPHOLDERS
 SHALL NOT BE PERMITTED IN CLOTHES CLOSETS. PROVIDE
 CORRECTION. NEC 410.16; FBC RE E4003.12
 10. A GFCI PROTECTED RECEPTACLE OUTLET ON A 20 AMP
 CIRCUIT IS REQUIRED WITHIN 3 FEET OF EACH BASIN.
 PROVIDE CORRECTION FOR MASTER BATH AND POWDER BATH. NEC
 210.11(C)(3), 210.52(D); FBC RE E3703.4, E3901.6
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2019-09-06 Cont ID  
Sent By dbattles Date 2019-09-06 Time 16:52 Rev Time 0.00
Received By dbattles Date 2019-09-05 Time 12:03 Sent To  
Notes
2019-09-06 12:03:24RESUB ROUTED TO DBATTLES

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2019-08-15 Cont ID  
Sent By cmontell Date 2019-08-21 Time 14:53 Rev Time 0.00
Received By hmoser Date 2019-08-05 Time 14:09 Sent To  
Notes
2019-08-06 14:09:21RESUB ROUTED TO TKLARGE

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-08-02 Cont ID  
Sent By dbattles Date 2019-08-02 Time 09:54 Rev Time 0.00
Received By dbattles Date 2019-07-29 Time 16:06 Sent To  
Notes
2019-07-30 16:06:16RESUB ROUTED TO RMCDOUGAL

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-07-03 Cont ID  
Sent By rmcdouga Date 2019-07-03 Time 08:37 Rev Time 0.00
Received By rmcdouga Date 2019-06-04 Time 15:49 Sent To  
Notes
2019-06-05 15:50:03R15

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-03-13 Cont ID  
Sent By hmoser Date 2019-03-13 Time 11:22 Rev Time 0.00
Received By hmoser Date 2019-02-13 Time 13:36 Sent To  
Notes
2019-02-14 13:36:39R18

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2019-09-06 Cont ID  
Sent By dbattles Date 2019-09-06 Time 16:52 Rev Time 0.00
Received By dbattles Date 2019-09-06 Time 16:52 Sent To  
Notes
2019-09-06 16:53:16OK - PLAN STAMPED
 MU-2019-026611-0000

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2019-03-12 Cont ID  
Sent By dbattles Date 2019-03-12 Time 14:05 Rev Time 0.00
Received By dbattles Date 2019-03-12 Time 14:05 Sent To  
Notes
2019-03-12 14:06:46109 FBC[AMENDED] PLANS REQUIRE REVIEW BY THE PBC IMPACT
 FEE OFFICE. ?CALL (561) 233-5025. ?UPON APPROVAL, YOU
 MAY CHECK OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR
 REVIEW. ?PLEASE RETURNED STAMPED AND WITH A COPY OF THE
 RECEIPT AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO THE PBC IMPACT FEE
 OFFICE. THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGO
 V.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONN
 AIRE.PDF
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER PX4191
 [email protected]
 561-805-6718
  

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2019-08-21 Cont ID  
Sent By hmoser Date 2019-08-15 Time 14:38 Rev Time 0.00
Received By cmontell Date 2019-08-21 Time 14:53 Sent To I
Notes
2019-08-15 14:38:31PLAN DENIED
 1) NO EQUIPMENT SCHEDULE ON PLANS
 4TH REVIEW.107 FBC 2017
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676
  
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2019-07-31 Cont ID  
Sent By rmcdouga Date 2019-07-31 Time 17:03 Rev Time 0.00
Received By rmcdouga Date 2019-07-31 Time 16:29 Sent To B
Notes
2019-07-31 17:19:19PLAN
 REVIEW COMMENTS
  
 3RD REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY MECHANICAL
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) FBC 107.2.1 - INFORMATION ON CONSTRUCTION DOCUMENTS.
 ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND
 ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF
 THE PERSON RESPONSIBLE FOR THE DESIGN. THERE IS AN
 ARCHITECT'S TITLE BLOCK ON THE MECHANICAL PLANS. THE
 ARCHITECT IS REQUIRED TO SIGN AND SEAL THE MECHANICAL
 PLANS WITH HIS NAME IN THE TITLE BLOCK WHEN SUBMITTED
 FOR PUBLIC RECORD PER CHAPTER 481, FLORIDA STATUTES &
 61G1 FLORIDA ADMINISTRATIVE CODE.
  
 2) THE HEATING AND COOLING EQUIPMENT IS PROVIDED ON THE
 FLOOR PLANS ON SHEET NUMBER 3 AND NOT SPECIFIED ON THE
 MECHANICAL PLANS ON SHEET NUMBER 4 AS REQUESTED. THERE
 ARE TWO PLAN SHEETS IDENTIFIED AS SHEET NUMBER 4. FBC
 107.2.1 PROVIDE THE MODEL NUMBERS AND SPECIFICATIONS OF
 THE HEATING AND COOLING EQUIPMENT IN AN EQUIPMENT
 SCHEDULE ON THE MECHANICAL PLAN THAT CORRESPONDS WITH
 THE EQUIPMENT SIZING CALCULATIONS.
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2019-07-03 Cont ID  
Sent By rmcdouga Date 2019-07-03 Time 08:37 Rev Time 0.00
Received By rmcdouga Date 2019-07-03 Time 07:49 Sent To I
Notes
2019-07-03 08:36:57PLAN
 REVIEW COMMENTS
  
 2ND REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY MECHANICAL
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) FBC 107.2.1 PROVIDE THE MODEL NUMBERS AND
 SPECIFICATIONS OF THE HEATING AND COOLING EQUIPMENT IN
 AN EQUIPMENT SCHEDULE ON THE MECHANICAL PLAN THAT
 CORRESPONDS WITH THE EQUIPMENT SIZING CALCULATIONS.
  
 2) FBC-R - M1305.1.3 APPLIANCES IN ATTICS.
 ATTICS CONTAINING APPLIANCES SHALL BE PROVIDED WITH AN
 OPENING AND A CLEAR AND UNOBSTRUCTED PASSAGEWAY LARGE
 ENOUGH TO ALLOW REMOVAL OF THE LARGEST APPLIANCE, BUT
 NOT LESS THAN 30 INCHES (762 MM) HIGH AND 22 INCHES
 (559 MM) WIDE AND NOT MORE THAN 6 FEET (1829 MM) LONG
 MEASURED ALONG THE CENTERLINE OF THE PASSAGEWAY FROM
 THE OPENING TO THE APPLIANCE. THE PASSAGEWAY SHALL HAVE
 CONTINUOUS SOLID FLOORING IN ACCORDANCE WITH CHAPTER 5
 NOT LESS THAN 24 INCHES (610 MM) WIDE. A LEVEL SERVICE
 SPACE AT LEAST 30 INCHES (762 MM) DEEP AND 30 INCHES
 (762 MM) WIDE SHALL BE PRESENT ALONG ALL SIDES OF THE
 APPLIANCE WHERE ACCESS IS REQUIRED. THE CLEAR ACCESS
 OPENING DIMENSIONS SHALL BE A MINIMUM OF 20 INCHES BY
 30 INCHES (508 MM BY 762 MM), AND LARGE ENOUGH TO ALLOW
 REMOVAL OF THE LARGEST APPLIANCE.
  
 3) FBC-R - M1305.1.3.1 ELECTRICAL REQUIREMENTS.
 A LUMINAIRE CONTROLLED BY A SWITCH LOCATED AT THE
 REQUIRED PASSAGEWAY OPENING AND A RECEPTACLE OUTLET
 SHALL BE INSTALLED AT OR NEAR THE APPLIANCE LOCATION IN
 ACCORDANCE WITH CHAPTER 34.
  
 4) THE SECOND FLOOR MECHANICAL PLAN SHOWS A 15" WIDE
 DUCT CHASE FOR THE RETURN AND SUPPLY AIR FOR THE FIRST
 FLOOR. THE RETURN DUCT FROM THE FIRST FLOOR IS SHOWN AS
 18". THE CHASE IS TOO SMALL TO ACCOMADATE THE 18" DUCT.
 FBC 107.2.1
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2019-03-13 Cont ID  
Sent By hmoser Date 2019-03-13 Time 11:21 Rev Time 0.00
Received By hmoser Date 2019-03-13 Time 11:06 Sent To  
Notes
2019-03-13 11:21:50DENIED
 NO AIR CONDITIONING PLAN SUBMITTED. HM.

Review Stop P PLUMBING
Rev No 3 Status P Date 2019-08-12 Cont ID  
Sent By tklarge Date 2019-08-12 Time 06:15 Rev Time 0.00
Received By tklarge Date 2019-08-12 Time 05:52 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-06-17 Cont ID  
Sent By thunt Date 2019-06-17 Time 13:26 Rev Time 0.00
Received By thunt Date 2019-06-17 Time 11:25 Sent To  
Notes
2019-06-17 12:32:27PLUMBING PROVISO:
 1) P2708.4SHOWER CONTROL VALVES.
 INDIVIDUAL SHOWER AND TUB/ SHOWER COMBINATION VALVES
 SHALL BE EQUIPPED WITH CONTROL VALVES OF THE
 PRESSURE-BALANCE, THERMOSTATIC-MIXING OR COMBINATION
 PRESSURE-BALANCE/THERMOSTATIC-MIXING VALVE TYPES WITH A
 HIGH LIMIT STOP IN ACCORDANCE WITH ASSE 1016/ASME
 A112.1016/CSA B125.16. THE HIGH LIMIT STOP SHALL BE SET
 TO LIMIT THE WATER TEMPERATURE TO NOT GREATER THAN
 120?F (49?C). IN-LINE THERMOSTATIC VALVES SHALL NOT BE
 USED FOR COMPLIANCE WITH THIS SECTION.
 2) P2709.3INSTALLATION.
 LINING MATERIALS SHALL BE SLOPED ONEFOURTH UNIT
 VERTICAL IN 12 UNITS HORIZONTAL (2-PERCENT SLOPE) TO
 WEEP HOLES IN THE SUBDRAIN BY MEANS OF A SMOOTH,
 SOLIDLY FORMED SUBBASE, SHALL BE PROPERLY RECESSED AND
 FASTENED TO APPROVED BACKING SO AS NOT TO OCCUPY THE
 SPACE REQUIRED FOR THE WALL COVERING, AND SHALL NOT BE
 NAILED OR PERFORATED AT ANY POINT LESS THAN 1 INCH
 (25.4 MM) ABOVE THE FINISHED THRESHOLD.
 3) P2801.6REQUIRED PAN.
 WHERE A STORAGE TANK-TYPE WATER HEATER OR A HOT WATER
 STORAGE TANK IS INSTALLED IN A LOCATION WHERE WATER
 LEAKAGE FROM THE TANK WILL CAUSE DAMAGE
 4) P2801.6.2PAN DRAIN TERMINATION.
 THE PAN DRAIN SHALL EXTEND FULL-SIZE AND TERMINATE OVER
 A SUITABLY LOCATED INDIRECT WASTE RECEPTOR OR SHALL
 EXTEND TO THE EXTERIOR OF THE BUILDING AND TERMINATE
 NOT LESS THAN 6 INCHES (152 MM) AND NOT MORE THAN 24
 INCHES (610 MM) ABOVE THE ADJACENT GROUND SURFACE.
 5) P2804.6.1REQUIREMENTS FOR DISCHARGE PIPE.
 THE DISCHARGE PIPING SERVING A PRESSURE-RELIEF VALVE,
 TEMPERATURE RELIEF VALVE OR COMBINATION VALVE SHALL
 DISCHARGE INTO THE ROOM THE WATER HEATER SERVES.
 6) WATER HEATER SHALL BE MIN .98E.F AS CALLED OUT IN
 THE R405 ENERGY FORM.
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-03-13 Cont ID  
Sent By thunt Date 2019-03-13 Time 09:52 Rev Time 0.00
Received By thunt Date 2019-03-13 Time 09:12 Sent To  
Notes
2019-03-13 09:52:21PLUMBING 1ST REVIEW**DENIED**
  
 1) VALUE SEEMS LOW.BUILDING PERMIT VALUATIONS. IF, IN
 THE OPINION OF THE BUILDING OFFICIAL, THE CLAIMED
 VALUATION
 OF BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS,
 MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE
 UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE
 DENIED, UNLESS THE APPLICANT CAN SHOW
 DETAILED, QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED
 CONTRACTS (EXCLUDING LAND VALUE) TO MEET THE
 APPROVAL OF THE BUILDING OFFICIAL. FOR PERMITTING
 PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL
 BE TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL,
 ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH,
 RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES,
 MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING
 ONLY LAND VALUE.. W.P.B AMEND TO THE FBC 109.3
  
 2) THESE PLANS ARE DIGITALLY SIGNED. ONLY PLANS
 SUBMITTED DIGITALLY ARE APPROVED TO BE SIGNED
 DIGITALLY. PLEASE HAVE PLANS WET SIGNED BY DESIGN
 PROFESSIONAL OF RECORD. F.S RULE 61G1-16.005
  
 3) SHT. D3 MASTER SHOWER IS MISSING FROM THE ISOMETRIC
 DRAWING. FBC 107.3.5
  
 4) SHT. D3 UPSTAIRS GUEST BATHROOM HAS 2 WET VENTED
 FIXTURES BEYOND THE WET VENT. ONLY 1 FIXTURE IS
 PERMITTED. FBC-R P3108.2.1
  
 5) THE 1ST BRANCH DRAIN THAT PICKS UP THE KITCHEN/
 WASHING MACHINE IS 2" AND PER TABLE FBC-R P 3005.4.1 IS
 PERMITTED A MAX 6 DFU'S. PER TABLE FBC-R P3004.1 YOU
 CURRENTLY HAVE 7 DFU'S. PLEASE CHANGE PIPE SIZE TO 3"
  
 TIM HUNT
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561-248-2703
  
 SAMANTHA HILL
 CHIEF PLANS EXAMINER
 561-805-6724

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2019-06-13 Cont ID  
Sent By dbattles Date 2019-06-13 Time 16:57 Rev Time 0.00
Received By dbattles Date 2019-06-13 Time 16:57 Sent To  
Notes
2019-06-13 16:56:06SHINGLE ROOF WITH 6/12 PITCH
 FL10674-R13 - OK

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2019-03-12 Cont ID  
Sent By dbattles Date 2019-03-12 Time 14:06 Rev Time 0.00
Received By dbattles Date 2019-03-12 Time 14:06 Sent To  
Notes
2019-03-12 14:08:57SHINGLE ROOF WITH 6/12 PITCH
 FL10674-R13 - OK

Review Stop Z ZONING
Rev No 3 Status P Date 2019-06-25 Cont ID  
Sent By awooten Date 2019-06-24 Time   Rev Time 0.00
Received By awooten Date 2019-06-24 Time   Sent To  
Notes
2019-06-24 16:53:09*************************ZONING
 PROVISO*******************************
  
 PRIOR TO THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY,
 THE FOLLOWING CONDITIONS SHALL BE ADDRESSED:
  
 1. A LANDSCAPE PERMIT, WHICH INCLUDES A LANDSCAPE PLAN,
 SHALL BE SUMBITTED TO THE BUILDING DIVISION FOR REVIEW.
  
 2. THE LANDSCAPE MATERIAL SHOWN ON THE APPROVED
 LANDSCPE PERMIT SHALL BE INSTALLED AND PASS A FINAL
 LANDSCAPE INSPECTION.
  
 ALANA WOOTEN
 ASSOCIATE PLANNER
 PLANNING DIVISION
 561-822-1449
 [email protected]

Review Stop Z ZONING
Rev No 2 Status F Date 2019-06-11 Cont ID  
Sent By awooten Date 2019-06-11 Time   Rev Time 0.00
Received By awooten Date 2019-06-07 Time 15:09 Sent To  
Notes
2019-06-11 14:50:37****************************************************ZON
 ING REVIEW
 FAILED******************************************
  
 LANDSCAPING (REPEAT COMMENT)
  
 PLEASE SUBMIT A SEPARATE LANDSCAPE AND IRRIGATION
 PERMIT. SHOWING THE FOLLOWING:
 RESIDENTIAL LANDSCAPE REQUIREMENTS CITY OF WEST PALM
 BEACH
 SECTION 94-442(C)(2)A. SINGLE FAMILY DWELLING UNITS
  
 GROSS LOT SQUARE FOOTAGE MINUS
 BUILDING FOOTPRINT SQUARE FOOTAGE EQUALS
 OPEN SPACE SQUARE FOOTAGE (ALL NON-BUILDING AREA)
 ONE TREE REQUIRED FOR EACH 1,000 SQ FT OF OPEN SPACE OR
 PORTION THEREOF
 ONE SHRUB REQUIRED FOR EACH 500 SQ FT OF OPEN SPACE OR
 PORTION THEREOF
  
 YOU CAN ALSO SUBMIT A CONDITIONAL LANDSCAPE APPROVAL
 FORM. PLEASE CONTACT ME FOR MORE INFORMATION ABOUT THIS
 FORM.
  
 ALANA WOOTEM
 ASSOCIATE PLANNER
 PLANNING DIVISION
 561-822-1449
 [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date 2019-02-22 Cont ID  
Sent By mcurz Date 2019-02-22 Time 15:31 Rev Time 0.00
Received By mcruz Date 2019-02-22 Time 14:51 Sent To  
Notes
2019-02-22 15:31:14ZONING REVIEW FAILED, DUE TO THE FOLLOWING:
  
 1) A LANDSCAPE PERMIT IS REQUIRED TO BE SUBMITTED AND
 APPROVED PRIOR TO ZONING APPROVAL.
  
 FOR ADDITIONAL INFORMATION, THE ZONING AND LAND
 DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT
 WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH
 PLANNING DEPARTMENT WEBSITE AT
 WWW.CITYOFWPB.COM/PLAN/INDEX.HTM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME. IF YOU WANT TO MEET IN PERSON TO GO OVER
 THE ABOVE COMMENTS, PLEASE CALL OR E-MAIL ME TO
 SCHEDULE AN APPOINTMENT.
  
 MAGGIE CRUZ
 ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: 561-822-1442
 E-MAIL: [email protected]
  