Plan Review Details - Permit 19020368
Plan Review Stops For Permit 19020368
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2019-02-28 Cont ID  
Sent By jgomez Date 2019-02-28 Time 14:58 Rev Time 0.00
Received By jgomez Date 2019-02-28 Time 14:49 Sent To  
Notes
2019-02-28 14:49:26TALKED TO KELLY. FL10450-R10 SEC. 5.6.4: INSTALLING
 ASSEMBLY #1 (-75.0 PSF) FOR FIELD AND PERIMETER ROOF
 AREAS AND ASSEMBLY #2 (-120.0 PSF) FOR CORNER ROOF
 AREAS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2019-02-25 Cont ID  
Sent By pvalenti Date 2019-02-25 Time 13:32 Rev Time 0.00
Received By pvalenti Date 2019-02-25 Time 13:32 Sent To  
Notes
2019-02-25 13:43:33****CORRECTIONS****
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 ITEM # 1 FROM THE LAST REVIEW STILL HAS NOT BEEN
 ADDRESSED. THE OPTION FROM SECTION 5.6.4 FROM THE
 PRODUCT APPROVAL # FL 10450-R10 HAS NOT BEEN SELECTED.
 PLEASE SEE COMMENT BELOW.
  
 ORIGINAL COMMENT:
 1? ROOF TILE UNDERLAYMENT FLORIDA PRODUCT APPROVAL
 FL10450?R10 SUBMITTED. CLEARLY SPECIFY IF THE
 UNDERLAYMENT IS GOING TO BE A DIRECT?DECK UNDERLAYMENT
 OR MECHANICALLY ATTACHED BASE SHEET. THEN THE FOLLOWING
 IS REQUIRED:
 A) FOR DIRECT?BOND TO DECK SEE NOTE AT BOTTOM OF SEC.
 5.6.1 AND CLEARLY IDENTIFY WHICH ASSEMBLY FROM SEC.
 5.6.4 IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE
 WITH THE DESIGN PRESSURES OF SEC. R301.1
 FBC?RESIDENTIAL. NOTE: IF SELECTED ASSEMBLY DOESN?T
 MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES, THEN IT
 CAN NOT BE USED.
 B) FOR MECHANICALLY ATTACHED BASE SHEET SEE SECTION
 5.6.2 AND PROVIDE MINIMUM FASTENING REQUIREMENTS FROM
 FRSA/TRI APRIL 2012 (04?12), APPENDIX A, TABLE 1.
 CLEARLY MARK TABLE 1 WITH PROPOSED FASTENING.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2019-02-21 Cont ID  
Sent By jgomez Date 2019-02-21 Time 11:36 Rev Time 0.00
Received By jgomez Date 2019-02-21 Time 11:15 Sent To  
Notes
2019-02-21 11:36:08RESIDENTIAL (R3) RE-ROOF SECOND BUILDING REVIEW
 CHECKLIST.
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 ORIGINAL COMMENT:
 1- ROOF TILE UNDERLAYMENT FLORIDA PRODUCT APPROVAL
 FL10450-R10 SUBMITTED. CLEARLY SPECIFY IF THE
 UNDERLAYMENT IS GOING TO BE A DIRECT-DECK UNDERLAYMENT
 OR MECHANICALLY ATTACHED BASE SHEET. THEN THE FOLLOWING
 IS REQUIRED:
  
 A) FOR DIRECT-BOND TO DECK SEE NOTE AT BOTTOM OF SEC.
 5.6.1 AND CLEARLY IDENTIFY WHICH ASSEMBLY FROM SEC.
 5.6.4 IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE
 WITH THE DESIGN PRESSURES OF SEC. R301.1
 FBC-RESIDENTIAL. NOTE: IF SELECTED ASSEMBLY DOESN'T
 MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES, THEN IT
 CAN NOT BE USED.
  
 B) FOR MECHANICALLY ATTACHED BASE SHEET SEE SECTION
 5.6.2 AND PROVIDE MINIMUM FASTENING REQUIREMENTS FROM
 FRSA/TRI APRIL 2012 (04-12), APPENDIX A, TABLE 1.
 CLEARLY MARK TABLE 1 WITH PROPOSED FASTENING.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
 2- OK.
  
 3- OK.
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE/VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 PLEASE DON'T STAPLE OLD DRAWINGS/DOCUMENTS. SUBMIT OLD
 DRAWINGS/DOCUMENTS FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-02-11 Cont ID  
Sent By jgomez Date 2019-02-11 Time 18:16 Rev Time 0.00
Received By jgomez Date 2019-02-11 Time 08:34 Sent To  
Notes
2019-02-11 18:17:10RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 1- ROOF TILE UNDERLAYMENT FLORIDA PRODUCT APPROVAL
 FL10450-R10 SUBMITTED. CLEARLY SPECIFY IF THE
 UNDERLAYMENT IS GOING TO BE A DIRECT-DECK UNDERLAYMENT
 OR MECHANICALLY ATTACHED BASE SHEET. THEN THE FOLLOWING
 IS REQUIRED:
  
 A) FOR DIRECT-BOND TO DECK SEE NOTE AT BOTTOM OF SEC.
 5.6.1 AND CLEARLY IDENTIFY WHICH ASSEMBLY FROM SEC.
 5.6.4 IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE
 WITH THE DESIGN PRESSURES OF SEC. R301.1
 FBC-RESIDENTIAL. NOTE: IF SELECTED ASSEMBLY DOESN'T
 MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES, THEN IT
 CAN NOT BE USED.
  
 B) FOR MECHANICALLY ATTACHED BASE SHEET SEE SECTION
 5.6.2 AND PROVIDE MINIMUM FASTENING REQUIREMENTS FROM
 FRSA/TRI APRIL 2012 (04-12), APPENDIX A, TABLE 1.
 CLEARLY MARK TABLE 1 WITH PROPOSED FASTENING.
  
 2- CLEARLY IDENTIFY ON PRODUCT APPROVALS THE ROOF TILE
 PROFILE AND PADDY SIZE AS REQUIRED BY CITY POLICY FOR
 ALL ROOFING PERMITS.
  
 3- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS,
 CONTRACTOR'S OVERHEAD AND PROFIT AND DESIGN
 PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY
 AMENDMENTS. VALUATION WAS UPDATED TO $327,792. THE
 PERMIT FEE BALANCE IS $645.44.
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE/VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 PLEASE DON'T STAPLE OLD DRAWINGS/DOCUMENTS. SUBMIT OLD
 DRAWINGS/DOCUMENTS FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-02-28 Cont ID  
Sent By jgomez Date 2019-02-28 Time 14:58 Rev Time 0.00
Received By jgomez Date 2019-02-28 Time 14:44 Sent To I
Notes
2019-02-28 14:48:56TALKED TO KELLY. FL10450-R10 SEC. 5.6.4: INSTALLING
 ASSEMBLY #1 (-75.0 PSF) FOR FIELD AND PERIMETER ROOF
 AREAS AND ASSEMBLY #2 (-120.0 PSF) FOR CORNER ROOF
 AREAS.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-02-21 Cont ID  
Sent By jgomez Date 2019-02-21 Time 11:36 Rev Time 0.00
Received By jgomez Date 2019-02-19 Time 15:39 Sent To I
Notes
2019-02-20 15:39:38RESUB ROUTED TO JGOMEZ

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-02-11 Cont ID  
Sent By jgomez Date 2019-02-11 Time 18:21 Rev Time 0.00
Received By jgomez Date 2019-02-08 Time 11:39 Sent To I
Notes
***NONE***