Plan Review Details - Permit 19020256
Plan Review Stops For Permit 19020256
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2019-04-19 Cont ID  
Sent By skennedy Date 2019-04-19 Time 12:03 Rev Time 0.00
Received By skennedy Date 2019-04-19 Time 12:03 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2019-03-04 Cont ID  
Sent By skennedy Date 2019-03-04 Time 15:18 Rev Time 0.00
Received By skennedy Date 2019-03-04 Time 15:18 Sent To  
Notes
2019-03-04 16:14:021ST REVIEW: FBC 2017 6TH EDITION
 1ST REVIEW FBC 2017 EXISTING BUILDING
  
 THE PERMIT APPLICATION APPEARS TO BE TO ALTER THE USE
 OF SPACE THAT MAY NEVER HAVE PREVIOUSLY RECEIVED A
 CERTIFICATE OF OCCUPANCY. PLEASE CHECK WITH CDS
 CUSTOMER SERVICE SPECIALIST CRAIG MCPHERSON AT 561
 805-6684 FOR A CERTIFICATE OF OCCUPANY FOR THIS SPACE
 IDENTIFIED AS THE 7TH FLOOR. THE PLANS ARE DEFICIENT AS
 THEY DO CONTAIN ADEQUATE INFORMATION TO DETERMINE THE
 INTENDED USE OF THE SPACE OR THE PREVIOUSLY APPROVED
 USE. PLEASE PROVIDE DRAWINGS OF ARCHITECTURAL QUAITY
 (NOT NECESSARILY SIGNED & SEAL BY AN ARCHITECT) TO
 DETERMINE THE INTENDED USE AND PROVIDE MINIMUM CODE
 DATE RELATIVE TO THE BUILDING SUCH AS TYPE OF
 CONSTRUCTION AND A LIFE SAFETY PLAN SHOWING EXITING
 STRATEGY AND THE EXISTENCE OF EXITING AND FIRE
 SUPPRESSION SYSYTEMS. PROVIDE AT A MINIMUM PROVIDE THE
 APPLICABLE CODE IN EFFECT AND LEVEL OF ALTERATION,
 OCCUPANCY CLASSIFICATION, OCCUPANT LOAD. PRESUMABLE THE
 SPACE MAY HAVE BEE APPROVED FOR A STORAGE USE. THIS
 WOULD RESULT IN A LOW OCCUPANT LOAD. EXISTING EXITS AND
 BATHROOM FACILITIES MAY BE SUFFICIENT, BUT THE PLAN
 DOES NOT ADDRESS EITHER MATTER. PLEASE PROVIDE RELATIVE
 INFORMATION.
  
 FBC-107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. ALL
 INFORMATION, DRAWINGS, SPECIFICATIONS AND ACCOMPANYING
 DATA SHALL BEAR THE NAME AND SIGNATURE OF THE PERSON
 RESPONSIBLE FOR THE DESIGN.
  
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN
 UPON SUITABLE MATERIAL. ELECTRONIC MEDIA DOCUMENTS
 SHALL BE SUBMITTED WHEN APPROVED BY THE BUILDING
 OFFICIAL. CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT
 CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF
 THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL
 CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT
 LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED
 BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND
 SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM
 OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS,
 WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE
 TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC,
 AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE
 OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS
 EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION. ALL INFORMATION, DRAWINGS, SPECIFICATIONS
 AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE
 OF THE PERSON RESPONSIBLE FOR THE DESIGN.
  
 IT IS NOTED THAT THIS APPLICATION IS APPLIED FOR BY A
 FENCE CONTRACTOR. APPLICATIONS OF THIS NATURE IS
 REQUIRED TO BE MADE BY A BUILDING OR GENERAL
 CONTRACTOR.
  
 PLEASE FEEL FREE TO CALL ME FOR FURTHER CLARIFICATION
 AND PRIOR TO UPLOADING NEW PLANS.
  
 STEVEN KENNEDY, CBO
 ASSISTANT BUILDING OFFICIAL
 (561) 805-6710
 [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-03-12 Cont ID  
Sent By shill Date 2019-02-26 Time 11:11 Rev Time 0.00
Received By shill Date 2019-02-26 Time 09:22 Sent To  
Notes
2019-03-12 11:11:55ORIGINAL REVIEW BY SAK - REVIEW WAS LOCKED; UNLOCKED
 AND CLOSED REVIEW ON 3/11
2019-02-26 09:23:29PLAN IS NOT LEGIBLE. I HAVE ASKED THE APPLICANT TO
 EMAIL TO ME A CLEAR VERSION. UPON RECEIPT, I WILL FOR
 WARD TO FIRE TO DETERMINE IF THEY WISH TO REVIEW THE
 APPLICATION.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-04-22 Cont ID  
Sent By jpearson Date 2019-04-22 Time 08:08 Rev Time 0.00
Received By jpearson Date 2019-04-22 Time 08:08 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2019-03-05 Cont ID  
Sent By jpearson Date 2019-03-05 Time 10:30 Rev Time 0.00
Received By jpearson Date 2019-03-05 Time 10:30 Sent To  
Notes
2019-03-05 10:31:57NO ELECTRICAL REVIEWED OR APPROVED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2019-04-19 Cont ID  
Sent By scaldero Date 2019-04-19 Time 14:00 Rev Time 0.00
Received By scaldero Date 2019-04-19 Time 13:44 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2019-02-27 Cont ID  
Sent By scaldero Date 2019-02-27 Time 13:28 Rev Time 0.00
Received By scaldero Date 2019-02-27 Time 13:20 Sent To  
Notes
2019-02-27 13:28:52PERMIT # 19020256
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 1) PLEASE PROVIDE ADDITIONAL DETAILS REGARDING CAGE
 ROOFING MATERIAL.
  
 2) MAY REQUIRE REVIEW BY FIRE SPRINKLER COMPANY TO
 ENSURE THAT ROOFING WILL NOT IMPEDE PROPER COVERAGE OF
 THE FIRE SPRINKLERS.
  
 3) REFERENCE IS MADE TO THE "SOW" DOCUMENT. "SOW" IS
 NOT PROVIDED IN THIS SUBMISSION.
  
  
 SUE ELLEN CALDERON
 ASSISTANT FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2019-04-22 Time   Rev Time 0.00
Received By cpuell Date 2019-04-17 Time 15:57 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2019-03-05 Time   Rev Time 0.00
Received By cpuell Date 2019-02-11 Time 15:56 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2019-03-04 Cont ID  
Sent By skennedy Date 2019-03-04 Time 15:13 Rev Time 0.00
Received By skennedy Date 2019-03-04 Time 15:13 Sent To  
Notes
2019-02-26 15:00:46THIS REVIEW MAY BE N/A.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2019-04-19 Cont ID  
Sent By skennedy Date 2019-04-19 Time 12:04 Rev Time 0.00
Received By skennedy Date 2019-04-19 Time 12:04 Sent To  
Notes
2019-04-19 12:04:47P ASSUMING NO RESUBMITTAL REQUIRED.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2019-03-05 Cont ID  
Sent By jpearson Date 2019-03-05 Time 10:30 Rev Time 0.00
Received By jpearson Date 2019-03-05 Time 10:30 Sent To  
Notes
2019-03-05 10:30:15EACH SHEET OF PLAN IS REQUIRED TO BE SIGNED AND SEALED
 BY THE PERSON RESPONSIBLE FOR THE DESIGN. A DIGITAL
 PLAN REQUIRES A DIGITAL SIGNATURE WITH THE PROPER THIRD
 PARTY VERIFICATION. PROVIDE CORRECTION. WPB FBC 107.1;
 FS 471/481

Review Stop Z ZONING
Rev No 1 Status N Date 2019-02-19 Cont ID  
Sent By aaponte Date 2019-02-19 Time 16:41 Rev Time 0.00
Received By aaponte Date 2019-02-19 Time 16:41 Sent To  
Notes
***NONE***