Plan Review Details - Permit 19020079
Plan Review Stops For Permit 19020079
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-02-11 Cont ID  
Sent By jduprey Date 2019-02-11 Time 14:08 Rev Time 0.00
Received By jduprey Date 2019-02-11 Time 14:02 Sent To  
Notes
2019-02-11 14:08:07BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 JOSEAN A. DUPREY E.I., BN, PX
 BUILDING PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6716
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. THE DETAIL DRAWING SHEET INDICATES ON A NOTE, "REFER
 TO SITE PLAN FOR DUMPSTER LOCATION AND DIMENSIONS"
 HOWEVER THE SITE DRAWING SHEET SP-1 SUBMITTED DOES NOT
 INDICATES ANY DUMPSTER DIMENSION. PLEASE RE-SUBMITT NEW
 SITE DRAWING SHEET WITH DUMPSTER DIMENSION PER
 ENGINEERING AND ZONNING COMMENTS. FBC 107

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2019-02-11 Cont ID  
Sent By RRossano Date 2019-02-11 Time   Rev Time 0.00
Received By rrossano Date 2019-02-11 Time   Sent To B
Notes
2019-02-11 06:57:17DUMPSTERS / SANITATION ENCLOSURES:
  
 1. DUMPSTER ENCLOSURE MUST HAVE A MINIMUM OF 12 FT.6
 IN. OPENING BETWEEN THE GATE POSTS.
 2. INTERIOR DIMENSIONS OF THE ENCLOSURE MUST BE A
 MINIMUM OF 12 FT.6 IN WIDE AND 6 FEET DEEP. A CONCRETE
 PARKING STOP BAR 10 FT. LONG MUST BE CENTERED (FROM
 GATES) AND INSTALLED 18 IN. FROM THE BACK WALL. STEEL
 BARS WILL NEED TO BE DRILLED THRU THE STOP BAR AND INTO
 THE INTERIOR FLOOR OF THE ENCLOSURE TO STOP THE STOP
 BAR FROM MOVING WHEN THE DUMPSTER IS SET INSIDE.
 3. THE OPENING OF THE DUMPSTER ENCLOSURE MUST BE ANGLED
 SO THAT A 40 FT. LONG TRUCK WITH THE FORKS EXTENDED CAN
 APPROACH THE OPENING AND PICK UP THE DUMPSTER WITHOUT
 MAKING A SHARP TURN OR A 3 POINT TURN.
 4. THE TRUCK NEEDS TO HAVE NO LESS THAN 16 FT. HIGH
 VERTICAL CLEARANCE AREA FOR THE TRUCK TO PICK UP THE
 DUMPSTER. THIS IS THE CLEAR AREA OVER THE DUMPSTER AND
 WHERE THE TRUCK WILL BE STOPPED TO UNLOAD THE DUMPSTER.
 5. THE TRUCK NEEDS TO HAVE NO LESS THAN 14 FT. HIGH
 VERTICAL CLEARANCE AND 12 FT. HORIZONTAL CLEARANCES FOR
 THE TRUCKS TO DRIVE THROUGH.
 6. IT IS STRONGLY SUGGESTED THAT YOU ADD A RECYCLING
 CENTER TO YOUR DUMPSTER ENCLOSURE
 7. NO FLOOR DRAIN TO THE SANITARY SEWER CAN BE
 INSTALLED IN THE DUMPSTER ENCLOSURE, UNLESS IT IS
 ROOFED SO NO RAIN WATER WILL GET INTO THE DRAIN.
 8. THE DUMPSTER ENCLOSURE MUST BE LOCATED TO ALLOW THE
 DUMP TRUCK TO BACK UP NO MORE THAN 50 FT. STRAIGHT BACK
 AFTER THE RESETTING OF THE DUMPSTER IN THE ENCLOSURE.
 9. ENCLOSURE DETAIL NOT SUBMITTED, OR SUBMITTED WITH
 NON-STANDARD DETAIL OR WITHOUT ENGINEERING SERVICES
 DEPARTMENT APPROVED STAMP.
 10. OWNER MAY AGREE TO THE CONDITION OF PLACING THE
 DUMPSTER IN AN OPEN AREA FOR PICKUP; HOWEVER THIS
 CONDITION WILL BE PLACED VIA NOTE ON YOUR APPROVED SITE
 PLAN.
 11. DUMPSTER LOADING AREA SHALL HAVE 10' CONCRETE
 SURFACE FOR TRUCK TO APPROACH. TYPICALLY ASPHALT IS
 USED IN THE AREA APPROACHING THE DUMPSTER AND IT
 QUICKLY DETERIORATES DUE TO THE FRONT WHEELS OF THE
 SANITATION VEHICLE.
 12. DUMPSTER DOORS SHALL HAVE STEEL PIN TO LOCK DOORS
 IN POSITION. TYPICALLY IN AN OPEN POSITION AND A CLOSED
 POSITION. THIS WOULD ALLOW DOORS TO BE STATIC AND NOT
 FREELY SWINGING.
 PLEASE SEE THE ENCLOSED LINK FOR A COPY OF THE CITY OF
 WEST PALM BEACH GENERAL CONSTRUCTION STANDARD DETAIL
 FOR DUMPSTER ENCLOSURES (GC-8). HTTP://WWW.WPB.ORG/DEPA
 RTMENTS/ENGINEERING-PUBLIC-WORKS/FORMS,-PERMITS-APPLICA
 TIONS
  
 FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR
 CONCERNS, THANKS.
  
 RICK ROSSANO
 PROJECT COORDINATOR
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1098
 FAX: (561) 494-1116
 MOBILE: (561) 246-9525
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
 MANNY GONZALEZ
 SENIOR ENGINEERING PROJECT COORDINATOR
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 MOBILE: (561) 644-7301
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
 CENTRAL OPERATIONS CENTER (DISPATCH):
 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC
 UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-02-11 Cont ID  
Sent By jduprey Date 2019-02-11 Time 14:08 Rev Time 0.00
Received By jduprey Date 2019-02-04 Time 13:37 Sent To  
Notes
2019-02-05 13:38:07ROUTED TO ZONING INBOX

Review Stop Z ZONING
Rev No 1 Status F Date   Cont ID  
Sent By   Date 2019-02-07 Time   Rev Time 0.00
Received By pgreilic Date 2019-02-07 Time 11:38 Sent To ENG
Notes
2019-02-07 11:39:491.) PROVIDE CITY-STANDARD DUMPSTER DETAIL (AS APPROVED
 ON SHEET SP-2 OF APPROVED SITE PLAN)
 2.) BUBBLE, CLOUD, OR OTHERWISE INDICATE ON SITE PLAN
 WHICH DUMPSTERS ARE BEING PROPOSED AS PART OF THIS
 PERMIT
  
 PAUL GREILICH, SENIOR PLANNER
 561-822-1443
 [email protected]
  