Plan Review Details - Permit 19011055
Plan Review Stops For Permit 19011055 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2019-02-20 |
|
|
Cont ID |
|
Sent By |
jduprey |
Date |
2019-02-20 |
Time |
17:25 |
Rev Time |
0.00 |
Received By |
jduprey |
Date |
2019-02-20 |
Time |
17:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2019-02-07 |
|
|
Cont ID |
|
Sent By |
jduprey |
Date |
2019-02-07 |
Time |
12:13 |
Rev Time |
0.00 |
Received By |
jduprey |
Date |
2019-02-07 |
Time |
12:07 |
Sent To |
E |
|
Notes |
2019-02-07 12:13:22 | BUILDING PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | JOSEAN A. DUPREY E.I., BN, PX | | BUILDING PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6716 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | RESULTS: DENIED | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. THE DRAWINGS SUBMITTED ARE NOT SIGNED BY THE | | DESIGNER. PLANS THAT HAVE BEEN PREPARED BY AN ENGINEER | | AND SUBMITTED FOR PUBLIC RECORD SHALL BEAR THE ORIGINAL | | SIGNATURE, DATE AND SEAL OF THE ENGINEER PER FL ADMIN. | | CODE RULE 61G15-23.001. | | | | 2. PLEASE INDICATE THE BOLT ANCHORS LOCATION. FBC 107 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2019-02-28 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-02-28 |
Time |
15:50 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-02-28 |
Time |
15:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2019-02-25 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2019-02-25 |
Time |
09:03 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2019-02-25 |
Time |
09:03 |
Sent To |
|
|
Notes |
2019-02-25 09:05:07 | FBC 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING | | PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE | | TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, | | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY | | LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST | | PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS | | SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. | | | | VALUE IS BASED ON ALL MATERIALS CUSTOMER OR CONTRACTOR | | SUPPLIED. JLEAHY |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2019-02-07 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2019-02-07 |
Time |
15:59 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2019-02-07 |
Time |
15:59 |
Sent To |
I |
|
Notes |
2019-02-07 15:59:44 | FLORIDA BUILDING CODE 2017 6TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | NFPA 70 2014 EDITION | | | | JAKE LEAHY | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | VALUE FOR WORK SHOWN IS TOO LOW. PLEASE SUBMIT A SIGNED | | CONTRACT WITH THE CUSTOMER FOR REVIEW. | | | | FBC 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING | | PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE | | TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, | | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY | | LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST | | PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS | | SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-02-25 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2019-02-25 |
Time |
09:05 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2019-02-12 |
Time |
14:45 |
Sent To |
|
|
Notes |
2019-02-13 14:45:33 | RESUB ROUTED TO ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-02-07 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2019-02-07 |
Time |
15:59 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2019-01-24 |
Time |
11:15 |
Sent To |
|
|
Notes |
2019-01-25 11:15:21 | ROUTED TO ZONING INBOX |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2019-02-19 |
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2019-02-19 |
Time |
14:02 |
Rev Time |
0.00 |
Received By |
mcruz |
Date |
2019-02-19 |
Time |
14:00 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2019-02-04 |
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2019-02-04 |
Time |
16:29 |
Rev Time |
0.00 |
Received By |
mcruz |
Date |
2019-02-04 |
Time |
16:09 |
Sent To |
B |
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |