Plan Review Stops For Permit 19010730 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2019-03-01 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2019-03-01 |
Time |
17:56 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2019-03-01 |
Time |
17:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2019-01-30 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2019-01-30 |
Time |
08:09 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2019-01-30 |
Time |
07:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2019-03-13 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-03-13 |
Time |
12:33 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-03-13 |
Time |
12:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2019-02-07 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-02-07 |
Time |
09:39 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-02-07 |
Time |
08:37 |
Sent To |
I |
|
Notes |
2019-02-07 09:38:55 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. ELECTRICAL PLAN IS REQUIRED TO BE SIGNED/SEALED BY A | | DESIGN PROFESSIONAL OR SIGNED BY THE ELECTRICAL | | CONTRACTOR QUALIFIER. PROVIDE CORRECTION. FS | | 471.003(2)(H); 471.025; WPB FBC 107.1 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2019-02-27 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2019-02-27 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2019-02-27 |
Time |
10:43 |
Sent To |
|
|
Notes |
2019-02-27 10:44:16 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | INSPECTION. | | | | | | | | 1) ANY WORK INVOLVING FIRE ALARM EQUIPMENT/DEVICES | | SHALL BE DONE UNDER SEPARATE PERMIT AND SHOP DRAWINGS. | | | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2019-01-22 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2019-01-22 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2019-01-22 |
Time |
13:30 |
Sent To |
|
|
Notes |
2019-01-22 13:32:50 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | INSPECTION. | | | | | | | | 1) ANY WORK INVOLVING FIRE ALARM EQUIPMENT/DEVICES | | SHALL BE DONE UNDER SEPARATE PERMIT AND SHOP DRAWINGS. | | | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-03-18 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2019-03-18 |
Time |
09:36 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2019-02-19 |
Time |
15:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2019-02-07 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2019-01-17 |
Time |
14:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
N |
Date |
2019-01-30 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2019-01-30 |
Time |
08:10 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2019-01-30 |
Time |
07:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
N |
Date |
2019-03-18 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2019-03-18 |
Time |
09:36 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2019-03-18 |
Time |
09:35 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2019-02-05 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2019-02-05 |
Time |
12:39 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2019-02-05 |
Time |
12:39 |
Sent To |
|
|
Notes |
2019-02-05 12:48:46 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT #19010730 | | 2/5/19 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET MEP-1: THERE ARE GENERAL NOTES ON THE PLAN FOR | | MECHANICAL BUT NO SPECIFIC PLAN OR NOTES FOR THE | | PROPOSED ALTERATION. PLEASE PROVIDE A COMPLETE SCOPE OF | | WORK OUTLINE AND MECHANICAL PLAN THAT SHOWS ALL | | ALTERATIONS TO THE EXISTING SYSTEMS INCLUDING A DUCT | | LAYOUT PLAN, AC EQUIPMENT SCHEDULE, AND THE RELOCATED | | DRYER EXHAUST RUN. PLEASE INCLUDE AN AC CHANGEOUT FORM | | IF THE SYSTEM IS BEING REPLACED- SECTION 107.2.1 WPB. | | | | 2) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE DRYER, | | THE RANGE, AND MICROWAVE- SECTIONS 504.1, AND 505.1 FBC | | M. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2019-03-13 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2019-03-13 |
Time |
09:09 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2019-03-13 |
Time |
07:38 |
Sent To |
|
|
Notes |
2019-03-13 08:51:52 | PLUMBING APPROVED WITH PROVISO: | | | | 1) ANY AND ALL WORK COVERED UP SHALL BE OPENED FOR | | INSPECTION AND INCLUDES BUT LIMITED TO. SHOWER WET | | WALLS, SHOWER PAN, CLOTHS WASHER AND ANY OTHER AREA | | THAT NEW PIPING IS IN. FBC 110.3 | | | | 2 ANY AND ALL THROUGH FLOOR PENETRATIONS SHALL BE | | SEALED WITH MATERIALS COMPLYING WITH THE FBC CHAPTER 7 | | FIRE AND SMOKE AND FBC ENERGY CODE IN FULL. RATED | | ASSEMBLY FOR SAID PENETRATIONS SHALL BE INCORPORATED | | INTO THE PLANS BY A APPROVED REVISION PRIOR TO THE 1ST | | INSPECTION. FBC 107.2.1. DOCUMENTS SHALL BE SIGNED AND | | SEAL BY DESIGN PROFESSIONAL OF RECORD. FBC 107.1 | | | | 3) PLUMBING ISOMETRIC HAS BEEN RED LINE TO MEET FBC | | PLUMBING CODE. | | | | 4) HAMMER ARRESTORS SHALL BE USED AT ALL QUICK CLOSING | | VALVES. FBC-P 604.9 | | | | 5) SHOWER PAN SHALL BE PRE-PITCH 1/4" PER FOOT. FBC RES | | P2709.3 | | | | 6) SHOWER AND TUB VALVES SHALL BE PRESSURE BALANCED, | | THERMOSTATIC AND A HIGH LIMIT OF 120F | | | | | | TIM HUNT | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-248-2703 | | | | SAMANTHA HILL | | CHIEF PLANS EXAMINER | | 561-805-6724 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2019-01-29 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2019-01-29 |
Time |
14:33 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2019-01-29 |
Time |
13:14 |
Sent To |
|
|
Notes |
2019-01-29 14:33:23 | APPROVED | | PROVISO | | 1. ALL WORK PER CITY CODES SUBJECT TO FIELD INSPECTOR'S | | APPROVAL | | 2. ROUGH IN WORK WHICH HAS BEEN COVERED SHALL BE OPENED | | FOR INSPECTION AND INCLUDES, BUT IS NOT LIMITED TO, | | SHOWER WET WALLS, SHOWER PANS AND THE CLOTHES WASHER. | | 3. SEE REDLINED RISER DIAGRAM AND FLOOR PLAN ON MEP-1 | | FOR CLOTHES WASHER SANITARY PIPING. | | 4. ANY AND ALL THROUGH FLOOR PENETRATIONS SHALL BE | | SEALED WITH MATERIALS COMPLYING WITH THE REQUIREMENTS | | OF FBC CHAPTER 7 FIRE & SMOKE PROTECTION FEATURES. | | RATED ASSEMBLY FOR SAID PENETRATIONS SHALL BE | | INCORPORATED INTO THE PLANS BY REVISION AND SHALL BE IN | | PLACE PRIOR TO THE FIRST PLUMBING INSPECTION PER WPB | | FBC 107.2.1. SAID PENETRATIONS INCLUDE BUT ARE NOT | | LIMITED TO THE SHOWER DRAIN PENETRATIONS, ESPECIALLY | | WHERE THE EXISTING BATHTUB WAS REPLACED BY A SHOWER. | | DOCUMENTS SHALL BE SIGNED BY THE PROFESSIONAL DESIGNER | | OF RECORD PER WPB FBC 107.1. | | | | SINCERELY, | | | | JERALD SMITH | | PLUMBING PLANS EXAMINER | | 561-805-6715 | | [email protected] | | |
|
|