Plan Review Details - Permit 19010249
Plan Review Stops For Permit 19010249
Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2019-01-31 Cont ID  
Sent By RRossano Date 2019-01-31 Time   Rev Time 0.00
Received By rrossano Date 2019-01-31 Time   Sent To I
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2019-01-11 Cont ID  
Sent By RRossano Date 2019-01-11 Time   Rev Time  
Received By rrossano Date 2019-01-11 Time   Sent To I
Notes
2019-01-11 07:44:09PLEASE ADDRESS ZONING COMMENTS.

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2019-01-09 Cont ID  
Sent By fmittner Date 2019-01-09 Time 11:12 Rev Time 0.00
Received By fmittner Date 2019-01-09 Time 11:12 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-01-31 Cont ID  
Sent By cpuell Date 2019-01-31 Time 10:03 Rev Time 0.00
Received By cpuell Date 2019-01-22 Time 13:24 Sent To  
Notes
2019-01-23 13:25:03RESUB ROUTED TO ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-01-11 Cont ID  
Sent By cpuell Date 2019-01-11 Time 10:43 Rev Time 0.00
Received By cpuell Date 2019-01-08 Time 16:42 Sent To  
Notes
2019-01-08 16:42:56ROUTED TO HISTORIC INBOX

Review Stop Z ZONING
Rev No 2 Status P Date 2019-01-30 Cont ID  
Sent By mcruz Date 2019-01-30 Time 10:33 Rev Time 0.00
Received By mcruz Date 2019-01-30 Time 10:30 Sent To ENG
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2019-01-09 Cont ID  
Sent By mcruz Date 2019-01-09 Time 14:01 Rev Time 0.00
Received By mcruz Date 2019-01-09 Time 14:01 Sent To ENG
Notes
2019-01-09 14:01:33ZONING REVIEW FAILED, DUE TO THE FOLLOWING:
  
 1) IS THIS A REPLACEMENT OF THE EXISTING DRIVEWAY OR
 EXPANSION?
 2) INDICATE ON SURVEYS THE DIMENSIONS (LXW) OF PROPOSED
 DRIVEWAY. DRIVEWAY WIDTH AT PROPERTY LINE SHALL NOT
 EXCEED 20' IN WIDTH.
 3) INDICATE THE SETBACK FROM THE PROPOSED DRIVEWAY TO
 THE SIDE PROPERTY LINE, SHOULD BE AT LEAST 3 FEET.
 4) ENSURE FRONT YARD MEETS LANDSCAPING REQUIREMENTS,
 WHEREBY, THE LESSER OF 1,000 SQUARE FEET OR 75 PERCENT
 OF THE FRONT YARD AREA SHALL BE LANDSCAPED WITH LIVING
 PLANT MATERIAL (SUCH AS GRASS, GROUND COVER, SHRUBS,
 HEDGES, VINES OR TREES). FRONT YARD AREA IS CALCULATED
 AS FOLLOWS: 25' X LENGTH OF FRONTAGE = FRONT YARD AREA.
  
 NOTES:
 IF MATERIAL OF NEW DRIVEWAY ARE PAVERS, THEN 60%
 LANDSCAPING IS REQUIRED.
 THE SUBMITTAL OF THE REQUESTED INFORMATION MAY GENERATE
 ADDITIONAL COMMENTS.
  
  
 FOR ADDITIONAL INFORMATION, THE ZONING AND LAND
 DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT
 WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH
 PLANNING DEPARTMENT WEBSITE AT
 WWW.CITYOFWPB.COM/PLAN/INDEX.HTM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME. IF YOU WANT TO MEET IN PERSON TO GO OVER
 THE ABOVE COMMENTS, PLEASE CALL OR E-MAIL ME TO
 SCHEDULE AN APPOINTMENT.
  
 MAGGIE CRUZ
 ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: 561-822-1442
 E-MAIL: [email protected]
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved