Plan Review Details - Permit 19010209
Plan Review Stops For Permit 19010209
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-03-27 Cont ID  
Sent By rmcdouga Date 2019-03-27 Time 19:08 Rev Time 0.00
Received By rmcdouga Date 2019-03-27 Time 19:01 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-02-04 Cont ID  
Sent By rmcdouga Date 2019-02-04 Time 19:06 Rev Time 0.00
Received By rmcdouga Date 2019-02-04 Time 18:01 Sent To I
Notes
2019-02-04 19:06:29PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) ELECTRONICALLY SUBMITTED PLANS ARE REQUIRED TO BE
 DIGITALLY SIGNED BY THE ENGINEER. FS 471 & FAC
 61G15-23.003
  
 2) FBC 107.2.5 THE CONSTRUCTION DOCUMENTS SUBMITTED
 WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY
 A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF
 NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE,
 DISTANCES FROM LOT LINES AND IT SHALL BE DRAWN IN
 ACCORDANCE WITH AN ACCURATE BOUNDARY LINE SURVEY.
  
 3) SPECIFY HOW THE POOL WILL COMPLY WITH THE
 RESIDENTIAL SWIMMING POOL BARRIER REQUIREMENTS OF FBC-R
 4501.17.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-03-25 Cont ID  
Sent By jpearson Date 2019-03-25 Time 10:35 Rev Time 0.00
Received By jpearson Date 2019-03-25 Time 10:35 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-01-30 Cont ID  
Sent By jpearson Date 2019-01-30 Time 15:52 Rev Time 0.00
Received By jpearson Date 2019-01-30 Time 15:52 Sent To  
Notes
2019-01-30 15:52:11CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. NO ELECTRICAL ISSUES. PLAN MUST HAVE THE PROPER
 DIGITAL SIGNATURE WITH THIRD PARTY VERIFICATION BEFORE
 ELECTRICAL CAN STAMP APPROVED. WPB FBC 107.1
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2019-01-29 Cont ID  
Sent By tklarge Date 2019-01-29 Time 15:02 Rev Time 0.00
Received By tklarge Date 2019-01-29 Time 15:02 Sent To  
Notes
2019-01-29 15:03:06THERE IS NO GAS HEATER ON THIS POOL.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-03-28 Cont ID  
Sent By tklarge Date 2019-03-28 Time 06:40 Rev Time 0.00
Received By tklarge Date 2019-03-14 Time 11:24 Sent To I
Notes
2019-03-15 11:24:55RESUB ROUTED TO ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-02-04 Cont ID  
Sent By rmcdouga Date 2019-02-04 Time 19:07 Rev Time 0.00
Received By rmcdouga Date 2019-01-09 Time 12:36 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-03-28 Cont ID  
Sent By tklarge Date 2019-03-28 Time 06:39 Rev Time 0.00
Received By tklarge Date 2019-03-28 Time 06:39 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-01-31 Cont ID  
Sent By tklarge Date 2019-01-31 Time 04:01 Rev Time 0.00
Received By tklarge Date 2019-01-31 Time 03:32 Sent To  
Notes
2019-01-29 15:08:181) EACH SHEET OF THE PLAN IS REQUIRED TO BE DIGITALLY
 SIGNED AND SEALED BY THE PERSON RESPONSIBLE FOR THE
 DESIGN. A DIGITAL PLAN REQUIRES A DIGITAL SIGNATURE
 WITH THE PROPER THIRD PARTY VERIFICATION. PROVIDE
 CORRECTION. FL. ADMINISTRATIVE CODE RULE 61G15-23.004.
 2) SHOW THE PROPOSED LOCATION OF THE POOL ON THE
 SURVEYS. WPB AMEND. TO FBC SEC. 107.2.1.
 3) SUBMIT TOTAL DYNAMIC HEAD CALCULATIONS FOR THE
 MAXIMUM SYSTEM FLOW. THE MAXIMUM FLOW OF THE PUMP FROM
 ITS PUMP CURVE IS NO LONGER ALLOWED TO BE USED IN
 DETERMINING MAXIMUM SYSTEM FLOW RATE PER ANSI/APSP/ICC
 7 - 2013 SECS. 4.4.9, 4.4.9.1. THE 2013 EDITION
 ADDRESSES FLOW RATE IN GALLONS PER MINUTE (GPM). IT
 REQUIRES THAT MAXIMUM SYSTEM FLOW RATE DOES NOT EXCEED
 THE LISTED MAXIMUM FLOW RATE OF THE SUCTION OUTLET
 FITTING ASSEMBLY (DRAIN COVER).THE TDH CALCULATIONS
 MUST INCLUDE ALL OF THE SYSTEM COMPONENTS INCLUDING
 SUCTION AND RETURN PIPING, FITTINGS, VALVES, HEATER,
 FILTER, AND CHLORINATOR. ALL SYSTEM COMPONENTS EXCEPT
 THE PUMP.
 4) SUBMIT TWO LEGIBLE COPIES OF THE POOL PUMP CURVE.
 IDENTIFY ON THE PUMP CURVE WHICH CURVE KEY IS SPECIFIC
 TO THE PUMP BEING INSTALLED ON THIS POOL. THIS IS
 NEEDED TO CONFIRM THE MAXIMUM SYSTEM FLOW FROM THE TDH
 CALCULATIONS. ANSI/APSP/ICC 7 - 2013 SECS. 4.4.9,
 4.4.9.1
  
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status N Date 2019-03-25 Cont ID  
Sent By jpearson Date 2019-03-25 Time 10:35 Rev Time 0.00
Received By jpearson Date 2019-03-25 Time 10:35 Sent To  
Notes
2019-03-25 10:35:05CHANGED TO PAPER PLAN, ELECTRONIC SIGNATURE
 VERIFICATION NOT NEEDED.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2019-01-30 Cont ID  
Sent By jpearson Date 2019-01-30 Time 15:35 Rev Time 0.00
Received By jpearson Date 2019-01-30 Time 15:35 Sent To  
Notes
2019-01-30 15:35:11EACH SHEET OF PLAN IS REQUIRED TO BE SIGNED AND SEALED
 BY THE PERSON RESPONSIBLE FOR THE DESIGN. A DIGITAL
 PLAN REQUIRES A DIGITAL SIGNATURE WITH THE PROPER THIRD
 PARTY VERIFICATION. PROVIDE CORRECTION. WPB FBC 107.1;
 FS 471/481

Review Stop Z ZONING
Rev No 2 Status P Date 2019-03-21 Cont ID  
Sent By mcruz Date 2019-03-21 Time 14:32 Rev Time 0.00
Received By mcruz Date 2019-03-21 Time 14:26 Sent To E
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2019-01-18 Cont ID  
Sent By mcurz Date 2019-01-18 Time 14:24 Rev Time 0.00
Received By mcruz Date 2019-01-18 Time 14:21 Sent To PC
Notes
2019-01-18 14:24:38ZONING REVIEW FAILED, DUE TO THE FOLLOWING:
  
 1) INDICATE ON SURVEY THE SETBACK FROM POOL EQUIPMENT
 TO REAR PROPERTY LINES.
  
 NOTE: PURSUANT TO 94-305(B)(4) - MECHANICAL EQUIPMENT
 MAY NOT PROJECT MORE THAN 4 FEET INTO A SETBACK.
  
 FOR ADDITIONAL INFORMATION, THE ZONING AND LAND
 DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT
 WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH
 PLANNING DEPARTMENT WEBSITE AT
 WWW.CITYOFWPB.COM/PLAN/INDEX.HTM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME. IF YOU WANT TO MEET IN PERSON TO GO OVER
 THE ABOVE COMMENTS, PLEASE CALL OR E-MAIL ME TO
 SCHEDULE AN APPOINTMENT.
  
 MAGGIE CRUZ
 ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: 561-822-1442
 E-MAIL: [email protected]