Plan Review Details - Permit 19010185
Plan Review Stops For Permit 19010185 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2019-07-31 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-07-31 |
Time |
15:59 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-07-31 |
Time |
15:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2019-01-26 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2019-01-26 |
Time |
10:31 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2019-01-26 |
Time |
10:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2019-07-25 |
|
|
Cont ID |
|
Sent By |
ppetty |
Date |
2019-07-25 |
Time |
14:32 |
Rev Time |
0.00 |
Received By |
ppetty |
Date |
2019-07-25 |
Time |
14:32 |
Sent To |
|
|
Notes |
2019-07-25 13:45:53 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: PASS WITH PROVISO, SEE | | COMMENTS BELOW. | | | | 1. | | 2. | | 3. | | 4. | | 5. | | 6. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. THIS | | INCLUDES LIGHTING AND POWER OUTLETS AND RECEPTACLES. | | SOME AREAS REQUIRE BOTH AFCI AND GFCI PROTECTION. | | PROVIDE CORRECTION. NEC 210.8, 210.12; FBC RE E3902; | | FBC EX 607.1.1 OR 801.1, 801.2, OR 901.2 AS APPLICABLE. | | 7. | | 8. | | 9. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | PER CODE. FBC RE R314.3, R315.1; WPB FBC 107.2.1 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | SHEETS. | | | | SINCERELY, | | | | PHIL PETTY | | ELECTRICAL PLANS EXAMINER | | 561-805-6742 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2019-01-23 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-01-23 |
Time |
07:49 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-01-23 |
Time |
07:16 |
Sent To |
|
|
Notes |
2019-01-23 07:48:55 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS | | IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. WPB FBC | | 109.3 | | 2. PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF | | PLAN IS REQUIRED TO BE SIGNED BY PERSON RESPONSIBLE FOR | | THE DESIGN. PROVIDE CORRECTION. FS 481.229; WPB FBC | | 107.1, 107.2.1, 107.3.5.1.2 | | 3. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | 4. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | 250.50, 250.94, 408.30; FBC RE E3706.1, E3608.1, | | E3609.3; WPB FBC 107.2.1 | | 5. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5, | | 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902 | | 6. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. THIS | | INCLUDES LIGHTING AND POWER OUTLETS AND RECEPTACLES. | | SOME AREAS REQUIRE BOTH AFCI AND GFCI PROTECTION. | | PROVIDE CORRECTION. NEC 210.8, 210.12; FBC RE E3902; | | FBC EX 607.1.1 OR 801.1, 801.2, OR 901.2 AS APPLICABLE. | | 7. RECEPTACLES INSTALLED TO SERVE THE COUNTER TOP IN | | KITCHEN REQUIRE GFCI PROTECTION. PROVIDE CORRECTION. | | NEC 210.8; FBC RE E3902.6 | | 8. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC | | 210.8(D); FBC RE E3902.10 | | 9. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | PER CODE. PROVIDE FULL FLOOR PLAN SHOWING ALL EXISTING | | ALARMS. IF NONE ARE EXISTING OR NOT TO CODE, SHOW AS | | NEW INSTALLATIONS. FBC RE R314.3, R315.1; WPB FBC | | 107.2.1 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2020-02-24 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-02-24 |
Time |
16:00 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-07-31 |
Time |
16:00 |
Sent To |
|
|
Notes |
2019-07-31 16:05:29 | PLAN REVIEW - GAS | | | | SOW - NEW SHUT OFF VALVES AND WHIPS AT WH, OVEN/RANGE & | | DRYER. CT | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2019-01-24 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2019-01-24 |
Time |
12:40 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2019-01-24 |
Time |
12:40 |
Sent To |
|
|
Notes |
2019-01-24 12:40:56 | 1ST REVIEW: | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | EDITION | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | EDITION | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | EDITION | | | | GAS COMMENTS: | | | | 1. IT IS UNCLEAR ON THE PLAN IF THE GAS APPLIANCES ARE | | NEW OR EXITING TO REMAIN PLEASE CLARIFY. PER WPB AMEND | | TO FBC 107.2.1 | | | | 2. IF THE THE GAS APPLIANCES ARE GOING TO BE NEW IN THE | | SAME LOCATION THE SIZING OF THE EXISTING SYSTEM SHALL | | BE VERIFIED TO MEET SIZING REQUIREMENTS AND IN GOOD | | WORKING ORDER. PLEASE PROVIDE THE FOLLOWING | | INFORMATION. | | A) A GAS RISER SHOWING, TYPE OF PIPE, SIZE OF PIPE, | | SYSTEM PRESSURE, BTU LOAD OF EACH APPLIANCE AND | | DISTANCE FROM THE METER TO FURTHEST APPLIANCE. PER FBC | | RES G2413.4 | | B)SIZING TABLE USED TO SIZE SYSTEM. PER FBC RES G2413.4 | | C)COMBUSTION AIR CALCULATIONS.PER FBC RES G2407.1 | | D) THE SIZE, TYPE, LENGTH, LOCATION OR A DETAIL SHOWING | | PIPING AND MANUFACTURE SPECIFICATION FOR THE WATER | | HEATER VENTING. PER FBC RES G2427.1 | | E) MANUFACTURE SPECIFICATIONS FOR ALL NEW GAS | | APPLIANCES. PER WPB AMEND TO FBC 107.2.1 | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS.PER WPB AMEND TO FBC | | 107.2.1 AND FBC RES G2401.1 | | | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-07-31 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-07-31 |
Time |
16:00 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-07-15 |
Time |
14:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-01-28 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2019-01-28 |
Time |
07:59 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2019-01-07 |
Time |
14:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2019-07-31 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-07-31 |
Time |
16:00 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-07-31 |
Time |
16:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2019-01-28 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2019-01-28 |
Time |
07:59 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2019-01-28 |
Time |
07:56 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2019-07-31 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-07-31 |
Time |
15:59 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-07-31 |
Time |
15:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2019-01-24 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2019-01-24 |
Time |
12:41 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2019-01-23 |
Time |
11:07 |
Sent To |
|
|
Notes |
2019-01-24 12:50:18 | | | 1ST REVIEW: 19010185 | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | EDITION | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | EDITION | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | EDITION | | | | PLUMBING COMMENTS: | | | | 1. PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF | | PLAN IS REQUIRED TO BE SIGNED BY PERSON RESPONSIBLE FOR | | THE DESIGN. PROVIDE CORRECTION. FS 481.229; WPB FBC | | 107.1, 107.2.1, 107.3.5.1. | | | | 2. THE WATER HEATER RELIEF VALVE PIPING SHALL COMPLY | | WITH FBC RES P2804.6.1 REQUIREMENTS FOR DISCHARGE PIPE. | | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] |
|
|
|