Plan Review Details - Permit 18120986
Plan Review Stops For Permit 18120986
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2019-07-29 Cont ID  
Sent By pvalenti Date 2019-07-29 Time 14:28 Rev Time 0.00
Received By pvalenti Date 2019-07-29 Time 14:28 Sent To  
Notes
2019-07-29 14:37:45PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 4TH BUILDING REVIEW APPROVED WITH PROVISO:
  
 PLEASE PROVIDE EXISTING SHUTTERS ON SITE FOR INSPECTOR
 TO OBSERVE AT TIME OF INSPECTION.
 ALL WORK PER CITY CODES IS SUBJECT TO FIELD INSPECTOR
 APPROVAL.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2019-04-20 Cont ID  
Sent By jduprey Date 2019-04-20 Time 09:16 Rev Time 0.00
Received By jduprey Date 2019-04-20 Time 09:09 Sent To  
Notes
2019-04-20 09:17:51BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 JOSEAN A. DUPREY
 BUILDING PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6716
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 3RD REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 NONE OF THE PREVIOUS COMMENTS WERE ADDRESS. PLEASE
 ADDRESS THEN AND RE-SUBMIT. PLEASE, SO NOT HESITATE TO
 CONTACT ME FOR ANY QUESTION.
 PREVIOUS COMMENTS:
  
 1. THE STATED VALUE APPEARS LOW FOR THE PROPOSED SCOPE
 OF WORK. THE PERMIT VALUATION AND PERMIT FEE MUST BE
 COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED
 CONTRACTOR WOULD PROVIDE.
 YOU MAY PROVIDE A COPY OF THE CONTRACT SIGNED BY THE
 OWNER OR A LIST OF LABOR, MATERIALS AND EQUIPMENT
 RENTAL TO VERIFY VALUE. CITY OF WPB CHAPTER 109.3
  
 2. PROVIDE PLAN SHOWING LOCATION OF WINDOWS WITH
 DIMENSIONS OF ROUGH OPENINGS. FBC 107
  
 3. INDICATE MODEL OF WINDOW TO BE INSTALLED FOR EACH
 OPENING FROM LIST OF AVAILABLE MODELS IN PRODUCT
 APPROVAL. FBC 107
  
 4. THE WINDOW PRODUCT APPROVAL SUBMITTED IDICATED THIS
 IS A NON-IMPACT WINDOW, FOR THIS REASON SHUTTERS ARE
 REQUIRED. PLEASE PROVIDE STORM PANEL INFORMATION WITH
 INSTALLATION SCHEDULE AND KEY PLAN WITH SPECIFIC
 ANCHORS AND MOUNTING TO BE USED FOR ALL NON-IMPACT
 GLAZING. FBC 1609.1.2.
  
 FOR SHUTTER SUBMITTAL PLEASE INCLUDE PRODUCT APPROVAL
 AND COMPLETE THE "SCHEDULE FOR INSTALLATION OF OPENING
 PROTECTIVE DEVICES" OR PROVIDE ALL INFORMATION REQUIRED
 IN ANOTHER FORMAT (SUCH AS EXCEL SPREADSHEET):
  
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS?PAGE=2

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2019-01-09 Cont ID  
Sent By jduprey Date 2019-01-09 Time 09:37 Rev Time 0.00
Received By jduprey Date 2019-01-09 Time 09:35 Sent To  
Notes
2019-01-09 09:37:23BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 JOSEAN A. DUPREY
 BUILDING PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6716
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 2ND REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. THE STATED VALUE APPEARS LOW FOR THE PROPOSED SCOPE
 OF WORK. THE PERMIT VALUATION AND PERMIT FEE MUST BE
 COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED
 CONTRACTOR WOULD PROVIDE.
 YOU MAY PROVIDE A COPY OF THE CONTRACT SIGNED BY THE
 OWNER OR A LIST OF LABOR, MATERIALS AND EQUIPMENT
 RENTAL TO VERIFY VALUE. CITY OF WPB CHAPTER 109.3
  
 2. PROVIDE PLAN SHOWING LOCATION OF WINDOWS WITH
 DIMENSIONS OF ROUGH OPENINGS. FBC 107
  
 3. INDICATE MODEL OF WINDOW TO BE INSTALLED FOR EACH
 OPENING FROM LIST OF AVAILABLE MODELS IN PRODUCT
 APPROVAL. FBC 107
  
 4. THE WINDOW PRODUCT APPROVAL SUBMITTED IDICATED THIS
 IS A NON-IMPACT WINDOW, FOR THIS REASON SHUTTERS ARE
 REQUIRED. PLEASE PROVIDE STORM PANEL INFORMATION WITH
 INSTALLATION SCHEDULE AND KEY PLAN WITH SPECIFIC
 ANCHORS AND MOUNTING TO BE USED FOR ALL NON-IMPACT
 GLAZING. FBC 1609.1.2.
  
 FOR SHUTTER SUBMITTAL PLEASE INCLUDE PRODUCT APPROVAL
 AND COMPLETE THE "SCHEDULE FOR INSTALLATION OF OPENING
 PROTECTIVE DEVICES" OR PROVIDE ALL INFORMATION REQUIRED
 IN ANOTHER FORMAT (SUCH AS EXCEL SPREADSHEET):
  
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS?PAGE=2

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-01-04 Cont ID  
Sent By jduprey Date 2019-01-04 Time 14:06 Rev Time 0.00
Received By jduprey Date 2019-01-04 Time 13:53 Sent To  
Notes
2019-01-04 14:06:04BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 JOSEAN A. DUPREY
 PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6716
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. THE STATED VALUE APPEARS LOW FOR THE PROPOSED SCOPE
 OF WORK. THE PERMIT VALUATION AND PERMIT FEE MUST BE
 COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED
 CONTRACTOR WOULD PROVIDE.
 YOU MAY PROVIDE A COPY OF THE CONTRACT SIGNED BY THE
 OWNER OR A LIST OF LABOR, MATERIALS AND EQUIPMENT
 RENTAL TO VERIFY VALUE. CITY OF WPB CHAPTER 109.3
  
 2. PROVIDE PLAN SHOWING LOCATION OF WINDOWS WITH
 DIMENSIONS OF ROUGH OPENINGS. FBC 107
  
 3. INDICATE MODEL OF WINDOW TO BE INSTALLED FOR EACH
 OPENING FROM LIST OF AVAILABLE MODELS IN PRODUCT
 APPROVAL. FBC 107
  
 4. THE WINDOW PRODUCT APPROVAL SUBMITTED IDICATED THIS
 IS A NON-IMPACT WINDOW, FOR THIS REASON SHUTTERS ARE
 REQUIRED. PLEASE PROVIDE STORM PANEL INFORMATION WITH
 INSTALLATION SCHEDULE AND KEY PLAN WITH SPECIFIC
 ANCHORS AND MOUNTING TO BE USED FOR ALL NON-IMPACT
 GLAZING. FBC 1609.1.2.
  
 FOR SHUTTER SUBMITTAL PLEASE INCLUDE PRODUCT APPROVAL
 AND COMPLETE THE "SCHEDULE FOR INSTALLATION OF OPENING
 PROTECTIVE DEVICES" OR PROVIDE ALL INFORMATION REQUIRED
 IN ANOTHER FORMAT (SUCH AS EXCEL SPREADSHEET):
  
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS?PAGE=2
  

Review Stop HIST HISTORICAL
Rev No 3 Status P Date 2019-04-19 Cont ID  
Sent By aborngra Date 2019-04-19 Time 16:47 Rev Time 0.00
Received By aborngra Date 2019-04-19 Time 16:45 Sent To B
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 2 Status F Date 2019-01-08 Cont ID  
Sent By aborngra Date 2019-01-08 Time 15:49 Rev Time 0.00
Received By aborngra Date 2019-01-08 Time 15:46 Sent To B
Notes
2019-01-08 15:48:42THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S):
  
 1. BASED ON INFORMATION PROVIDED, THE WINDOWS BEING
 REPLACED ARE FOR THE FRONT STRUCTURE LOCATED AT 913 8TH
 STREET. ALL WINDOWS WILL REQUIRE A 9/1 LITE PATTERN TO
 REPLACE THE ORIGINAL WOOD WINDOW CONFIGURATION WITH
 OGEE DIMENSIONAL MUNTINS. THE FRONT #1 AND FRONT #2
 WINDOWS MAY BE A 6/1 LITE PATTERN WITH OGEE DIMENSIONAL
 MUNTINS, IF PROOF CAN BE SUBMITTED THAT CURRENT WINDOWS
 ARE WOOD WINDOWS. A PHOTO MAY BE SUFFICIENT PROOF.
  
 WHEN PERMIT IS APPROVED, THE WORK WILL HAVE THE
 FOLLOWING CONDITIONS:
  
 1. ALL WINDOWS MUST FIT THE ORIGINAL WINDOW FRAME SIZE.
 2. THE WINDOW GLASS MUST BE CLEAR OR HAVE LOW-E GLASS.
  
 FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER,
 HISTORIC PRESERVATION PLANNER AT [email protected].
  
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER
 CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES
 T: 561-822-1428
 [email protected]

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2019-01-04 Cont ID  
Sent By jduprey Date 2019-01-04 Time 14:06 Rev Time 0.00
Received By aborngra Date 2019-01-04 Time 08:48 Sent To B
Notes
2019-01-04 08:51:37THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S):
  
 1. PROVIDE WINDOW LOCATIONS ON A SITE PLAN OR SIMILAR
 ILLUSTRATION.
  
 WHEN PERMIT IS APPROVED, THE WORK WILL HAVE THE
 FOLLOWING CONDITIONS:
  
 1. ALL WINDOWS MUST FIT THE ORIGINAL WINDOW FRAME SIZE.
 2. THE WINDOW GLASS MUST BE CLEAR OR HAVE LOW-E GLASS.
  
 FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER,
 HISTORIC PRESERVATION PLANNER AT [email protected].
  
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER
 CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES
 T: 561-822-1428
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-04-20 Cont ID  
Sent By jduprey Date 2019-04-20 Time 09:17 Rev Time 0.00
Received By jduprey Date 2019-04-18 Time 13:41 Sent To  
Notes
2019-04-19 13:41:22RESUB ROUTED TO HISTORIC INBOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-01-09 Cont ID  
Sent By jduprey Date 2019-01-09 Time 09:37 Rev Time 0.00
Received By jduprey Date 2019-01-07 Time 11:42 Sent To  
Notes
2019-01-08 11:42:16RESUB ROUTED TO HISTORIC INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-01-04 Cont ID  
Sent By jduprey Date 2019-01-04 Time 14:06 Rev Time 0.00
Received By jduprey Date 2018-12-28 Time 10:04 Sent To HIST
Notes
***NONE***