Plan Review Stops For Permit 18120818 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2019-02-15 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-02-15 |
Time |
14:23 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-02-15 |
Time |
14:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2019-02-13 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-02-13 |
Time |
15:20 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-02-13 |
Time |
13:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2019-01-23 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2019-01-23 |
Time |
09:21 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2019-01-23 |
Time |
08:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2019-01-11 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2019-01-11 |
Time |
14:59 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2019-01-11 |
Time |
14:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
Rev No |
1 |
Status |
P |
Date |
2019-01-11 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2019-01-11 |
Time |
15:34 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2019-01-11 |
Time |
15:34 |
Sent To |
|
|
Notes |
2019-01-11 15:36:36 | 4 ADDED TEL/COMPUTER OUTLETS |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2019-02-01 |
|
|
Cont ID |
|
Sent By |
scaldero |
Date |
2019-02-01 |
Time |
12:05 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2019-02-01 |
Time |
12:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2019-01-03 |
|
|
Cont ID |
|
Sent By |
scaldero |
Date |
2019-01-03 |
Time |
14:27 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2019-01-03 |
Time |
13:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2019-02-15 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2019-02-15 |
Time |
14:22 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2019-02-14 |
Time |
14:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-02-13 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-02-13 |
Time |
15:31 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-01-30 |
Time |
16:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-01-24 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2019-01-24 |
Time |
08:29 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2019-01-02 |
Time |
15:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
N |
Date |
2019-01-23 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2019-01-23 |
Time |
09:19 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2019-01-23 |
Time |
09:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2019-02-13 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2019-02-13 |
Time |
14:55 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2019-02-13 |
Time |
14:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2019-01-16 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2019-01-16 |
Time |
17:32 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2019-01-16 |
Time |
17:30 |
Sent To |
|
|
Notes |
2019-01-16 17:35:42 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT #18120818 | | 1/16/19 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET M-1: PROVIDE AN AUTOMATICALLY CONTROLLED | | SHUTOFF DAMPER FOR THE O/A INTAKE DUCT- SECTION | | C403.2.4.3 FBC-17 EC. | | | | 2) M-2: SUBMIT A FL. PRODUCT AND/OR MIAMI-DADE NOA FOR | | THE CONDENSER STRAPS WITH APPROVAL STAMP BY THE | | ENGINEER OF RECORD- SECTION 107.2.1 WPB. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2019-02-13 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2019-02-13 |
Time |
14:05 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2019-02-13 |
Time |
14:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2019-01-24 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2019-01-24 |
Time |
08:25 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2019-01-22 |
Time |
18:21 |
Sent To |
|
|
Notes |
2019-01-24 08:25:50 | | | 3RD REVIEW: 18120818 | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | EDITION | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | EDITION | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | EDITION | | | | PLUMBING COMMENTS: | | | | 1.SHT. A0.1 DETAIL #1-2 GRAB BARS SHALL BE INSTALLED IN | | A HORIZONTAL POSITION, 33 INCHES MINIMUM AND 36 INCHES | | MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF | | THE GRIPPING SURFACE AS THEY ARE SHOWN NOW THERE IS 2 | | DIFFERENT DIMENSIONS DETAIL #2 IS NOT CODE COMPLIANT . | | FBC ACC 609.4 | | | | 2. SHT. A0.1 PLEASE SHOW COMPLIANCE WITH FBC ACC 606.3 | | HEIGHT.LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE | | FRONT OF THE HIGHER OF THE RIM OR COUNTER SURFACE 34 | | INCHES (865 MM) MAXIMUM ABOVE THE FINISH FLOOR OR | | GROUND. | | | | 3. SHT. A1.1 PLEASE SHOW THE CLEAR FLOOR SPACE FOR THE | | TOILET AND LAVATORY WITH DIMENSIONS. PER FBC ACC | | 604.3.1, 606.2 | | | | 4. THE BREAK ROOM SINK SHALL COMPLY WITH FBC ACC 606.3 | | HEIGHT.LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE | | FRONT OF THE HIGHER OF THE RIM OR COUNTER SURFACE 34 | | INCHES (865 MM) MAXIMUM ABOVE THE FINISH FLOOR OR | | GROUND. | | | | 5. SHT. P-1 THE LAVATORY'S ON THE SANITARY ISOMETRIC | | ARE S TRAPPED WHICH IS PROHIBITED THEY SHALL HAVE A | | VENT STACK OR AAV. PER FBC PL 1002.3, 901.2.1 | | | | 6. SHT. P-1 ON THE SANITARY ISOMETRIC THE BREAK ROOM | | SINK APPEARS TO BE LABELED AS A LAVATORY PLEASE | | CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | 7. TEMPERED WATER SHALL BE DELIVERED FROM LAVATORIES | | AND GROUP WASH FIXTURES LOCATED IN PUBLIC TOILET | | FACILITIES PROVIDED FOR CUSTOMERS, PATRONS AND | | VISITORS. TEMPERED WATER SHALL BE DELIVERED THROUGH AN | | APPROVED WATER-TEMPERATURE LIMITING DEVICE THAT | | CONFORMS TO ASSE 1070 OR CSA B125.3. PER FBC PL 416.5 | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2019-02-15 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-02-15 |
Time |
14:21 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-02-15 |
Time |
14:16 |
Sent To |
I |
|
Notes |
2019-02-15 14:22:55 | ENERGY CALCULATIONS AND LOAD CALCULATIONS DIGITAL | | SIGNATURE OK. JG. |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2019-02-13 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-02-13 |
Time |
15:17 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-02-13 |
Time |
15:17 |
Sent To |
|
|
Notes |
2019-02-13 15:25:19 | NEED ENERGY CALCULATIONS AND LOAD CALCULATIONS WITH | | ENGINEER'S ORIGINAL SEAL AND SIGNATURE AS REQUIRED BY | | CHAPTER 471 F.S. WHEN SUBMITTING DOCUMENTS FOR PUBLIC | | RECORDS. THEY ARE NOT DIGITALLY SIGNED AND SEALED. |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2019-01-24 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2019-01-24 |
Time |
08:27 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2019-01-24 |
Time |
08:27 |
Sent To |
|
|
Notes |
2019-01-24 08:29:30 | PLUMBING SHEET IS NOT DIGITALY SIGNED. PER FAC | | 61G15-23.003 | 2019-01-16 17:38:19 | MECHANICAL PLANS, AC CALCS, AND ENERGY FORM NOT | | DIGITALLY SIGNED AND SEALED. |
|
|