Plan Review Details - Permit 18120784
Plan Review Stops For Permit 18120784 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2019-01-19 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2019-01-19 |
Time |
11:59 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2019-01-19 |
Time |
11:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2019-01-07 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2019-01-07 |
Time |
09:44 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2019-01-07 |
Time |
07:29 |
Sent To |
|
|
Notes |
2019-01-07 16:35:49 | ****CORRECTIONS**** | | | | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | FBC B 107. | | 1. MISSING DESIGNER OF RECORD REVIEW STAMP ON ROOFING | | SUBMITTALS. | | 2. THE SUBMITTALS STATE THE DECK MATERIAL IS 22 GAGE | | AND THE STRUCTURAL PAGE (DS102 FROM THE MASTER PERMIT # | | 18090957) STATES A MINIMUM OF 20 GAGE DECK MATERIAL. | | 3. MISSING DETAILS FROM STRUCTURAL SUPPORT (COLUMN | | SCHEDULE FROM MASTER PERMIT) OF ROOF DECK. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL COMMENTS MAY | | RESULT IN NEW PLAN REVIEW COMMENTS. | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-01-19 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2019-01-19 |
Time |
12:00 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2019-01-14 |
Time |
13:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-01-07 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2019-01-07 |
Time |
09:55 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2019-01-03 |
Time |
09:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2019-01-19 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2019-01-19 |
Time |
12:00 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2019-01-19 |
Time |
12:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2019-01-07 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2019-01-07 |
Time |
09:44 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2019-01-07 |
Time |
09:44 |
Sent To |
|
|
Notes |
2019-01-07 09:55:42 | ****CORRECTIONS**** | | | | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | FBC 107./FS 471/FAC 61G15-23.001, THE PLANS ARE MISSING | | SIGNATURES/SEALS/TITLE BLOCKS. | 2019-01-04 09:25:41 | HARD COPIES LOCATED IN LIBRARY. LEM |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |