Plan Review Details - Permit 18120417
Plan Review Stops For Permit 18120417 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2019-08-16 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-08-16 |
Time |
15:21 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-08-16 |
Time |
15:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2018-12-28 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2018-12-28 |
Time |
09:21 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2018-12-28 |
Time |
09:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
N |
Date |
2019-08-26 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-08-26 |
Time |
13:58 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-08-26 |
Time |
09:20 |
Sent To |
|
|
Notes |
2019-08-26 13:58:43 | PLAN STATES NO ELECTRICAL WORK. AN ELECTRICAL PERMIT | | WILL BE REQUIRED FOR ANY ELECTRICAL WORK TO BE | | PERFORMED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2018-12-24 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-12-24 |
Time |
15:59 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-12-24 |
Time |
15:59 |
Sent To |
|
|
Notes |
2018-12-24 15:59:50 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED AND | | SEALED BY THE PERSON RESPONSIBLE FOR THE DESIGN. WPB | | FBC 107.2.1, 107.3.5; FS 471, 481 | | 2. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | PER CODE. PROVIDE FULL FLOOR PLAN SHOWING ALL EXISTING | | ALARMS. IF NONE ARE EXISTING OR NOT TO CODE, SHOW AS | | NEW INSTALLATIONS. FBC RE R314.3, R315.1; WPB FBC | | 107.2.1 | | 3. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS | | IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. WPB FBC | | 109.3 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2019-08-26 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2019-08-13 |
Time |
13:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-01-07 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2019-01-07 |
Time |
14:48 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2018-12-12 |
Time |
15:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2019-08-21 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2019-08-21 |
Time |
16:40 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2019-08-21 |
Time |
16:40 |
Sent To |
|
|
Notes |
2019-08-21 16:43:05 | 08/21/19 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2019-01-07 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2019-01-07 |
Time |
14:47 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2019-01-07 |
Time |
14:47 |
Sent To |
|
|
Notes |
2019-01-07 14:48:49 | 01/07/19 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVE PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER | | |
|
|
|