Plan Review Details - Permit 18120326
Plan Review Stops For Permit 18120326
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-01-10 Cont ID  
Sent By skennedy Date 2019-01-10 Time 10:26 Rev Time 0.00
Received By skennedy Date 2019-01-10 Time 10:26 Sent To  
Notes
2019-01-10 10:28:2519010330 REMODEL APPLIED FOR, NO ELECTRICAL DEMO WILL
 OCURR.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-12-14 Cont ID  
Sent By jduprey Date 2018-12-14 Time 10:44 Rev Time 0.00
Received By jduprey Date 2018-12-14 Time 10:44 Sent To E
Notes
2018-12-14 10:44:35BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 JOSEAN A. DUPREY
 PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6716
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1.PLEASE PROVIDE A FLOOR PLAN WITH A DETAILED SCOPE OF
 WORK. FBC107
  

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2019-01-10 Cont ID  
Sent By skennedy Date 2019-01-10 Time 10:28 Rev Time 0.00
Received By skennedy Date 2019-01-10 Time 10:28 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-12-18 Cont ID  
Sent By fgiaquin Date 2018-12-18 Time 06:53 Rev Time 0.00
Received By fgiaquin Date 2018-12-18 Time 06:43 Sent To I
Notes
2018-12-18 06:43:48ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED AND
 SEALED BY A LICENSED DESIGN PROFESSIONAL OR SIGNED BY
 THE ELECTRICAL CONTRACTOR QUALIFIER. IF THERE IS NOT
 ANY ELECTRICAL WORK INCLUDED WITH THIS PERMIT, STATE
 THAT ON PLAN. FS 471.003(2)(H); 471.025; WPB FBC
 107.2.1, 107.3.5
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 CODES IN EFFECT:
  
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2017 6TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 FRANK GIAQUINTO III
 ELECTRICAL INSPECTOR
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 [email protected]
 CELL: 561-657-1653
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-12-18 Cont ID  
Sent By fgiaquin Date 2018-12-18 Time 06:53 Rev Time 0.00
Received By fgiaquin Date 2018-12-10 Time 13:26 Sent To  
Notes
2018-12-11 13:26:26SHILL


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved