Plan Review Details - Permit 18111154
Plan Review Stops For Permit 18111154 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2018-12-18 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2018-12-18 |
Time |
13:47 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2018-12-18 |
Time |
13:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2018-12-28 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-12-28 |
Time |
09:02 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-12-28 |
Time |
09:02 |
Sent To |
|
|
Notes |
2018-12-28 09:02:12 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PLAN IS REQUIRED TO BE REVIEWED AND APPROVED BY PALM | | BEACH OUTLETS MANAGEMENT PRIOR TO APPROVAL FROM | | BUILDING DEPARTMENT. PROVIDE CORRECTION. WPB FBC 107.1, | | 107.2.1 | | 2. WHEN JOB IS AWARDED TO CONTRACTOR, PROVIDE COPY OF | | CONTRACT TO CONFIRM VALUE OF WORK. WPB FBC 109.3 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2018-12-03 |
|
|
Cont ID |
|
Sent By |
scaldero |
Date |
2018-12-03 |
Time |
10:28 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2018-12-03 |
Time |
09:29 |
Sent To |
|
|
Notes |
2018-12-03 10:28:43 | PERMIT # 18111154 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | APPROVED WITH COMMENTS: | | | | 1) SHEET A0.1: UPDATE THE CODE LIST TO REFERENCE THE | | 6TH EDITION OF THE FLORIDA FIRE PREVENTION CODE WHICH | | CONTAINS THE 2015 EDITION OF BOTH NFPA 1 AND NFPA 101 | | WITH FLORIDA AMENDMENTS. | | | | 2) PROVIDE DRAWING NOTE INDICATING, ?FIRE PROTECTION | | SYSTEMS SHALL REMAIN ACTIVE DURING DEMOLITION AND | | RENOVATION ACTIVITIES. IN THE EVENT A FIRE PROTECTION | | SYSTEM IS OUT OF SERVICE FOR MORE THAN 4-HOURS IN A | | 24-HOUR PERIOD, THE BUILDING SHALL BE PLACED UNDER A | | FIRE WATCH. ALL FIRE WATCH REQUESTS MUST BE SUBMITTED | | BY EMAIL ([email protected]) OR IN WRITING (FAX: | | 561-804-4774) AND APPROVED BY THE OFFICE OF THE FIRE | | MARSHAL LOCATED AT 500 NORTH DIXIE HIGHWAY.? | | | | 3) SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE | | INSTALLATION OR MODIFICATION OF THE FIRE SPRINKLER | | SYSTEM AND/OR FIRE ALARM SYSTEM. | | | | | | SUE ELLEN CALDERON | | ASSISTANT FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-01-15 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2019-01-15 |
Time |
08:51 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-12-02 |
Time |
08:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2019-01-15 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2019-01-15 |
Time |
08:49 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2019-01-15 |
Time |
08:17 |
Sent To |
|
|
Notes |
2019-01-15 08:51:15 | NO PLUMBING WORK SHOWN ON PLAN. | | SEPARATE PERMIT AND PLANS REQUIRED FOR ANY PLUMBING | | WORK. |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2018-12-28 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-12-28 |
Time |
07:11 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-12-28 |
Time |
07:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2018-12-31 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2018-12-31 |
Time |
11:51 |
Rev Time |
0.50 |
Received By |
eschneid |
Date |
2018-12-31 |
Time |
11:51 |
Sent To |
|
|
Notes |
2018-12-31 11:58:36 | FAILED | | | | PLEASE PROVIDE WRITTEN RESPONSE TO COMMENTS. | | | | 1) THE STOREFRONT WINDOWS MAY NOT BE BLOCKED BY OPAQUE | | FILM. | | | | 2) PROVIDE INFORMATION ON WHAT THE ?PLASTIC BOLLARD | | COVERS? LOOK LIKE. NOTE: THEY ARE NOT PERMITTED TO | | CONTAIN ADVERTISING. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | [email protected] | | |
|
|
|