Plan Review Stops For Permit 18111109 |
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
3 |
Status |
P |
Date |
2019-07-24 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2019-07-24 |
Time |
|
Rev Time |
0.00 |
Received By |
rrossano |
Date |
2019-07-24 |
Time |
|
Sent To |
I |
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
P |
Date |
2019-07-10 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2019-07-10 |
Time |
|
Rev Time |
0.00 |
Received By |
rrossano |
Date |
2019-07-10 |
Time |
|
Sent To |
I |
|
Notes |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2018-12-20 |
|
|
Cont ID |
|
Sent By |
RRossano |
Date |
2018-12-20 |
Time |
|
Rev Time |
|
Received By |
rrossano |
Date |
2018-12-20 |
Time |
|
Sent To |
I |
|
Notes |
2018-12-20 07:30:29 | PLEASE ADDRESS FIRE & MECHANICAL COMMENTS AND SUBMIT | | FULL SIZE PLANS. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2019-07-17 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2019-07-17 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2019-07-17 |
Time |
15:08 |
Sent To |
M |
|
Notes |
2019-07-17 15:09:11 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | INSPECTION. | | | | | | 1) THE PROPOSED UNDERGROUND SHALL BE INSTALLED, | | INSPECTED AND TESTED PER NFPA 24. | | | | | | | | 2) PLEASE DO NOT COVER OVER ANY JOINTS PRIOR TO | | INSPECTION. | | | | | | | | 3) PLEASE ENSURE COMPLIANCE AND ENSURE MANUFACTURES | | SPECIFICATIONS ARE ONSITE FOR FIRE INSPECTOR REVIEW AND | | VERIFICATION. | | | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2019-06-28 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2019-06-28 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2019-06-28 |
Time |
11:00 |
Sent To |
M |
|
Notes |
2019-06-28 11:03:43 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | INSPECTION. | | | | | | 1) THE PROPOSED UNDERGROUND SHALL BE INSTALLED, | | INSPECTED AND TESTED PER NFPA 24. | | | | | | | | 2) PLEASE DO NOT COVER OVER ANY JOINTS PRIOR TO | | INSPECTION. | | | | | | | | 3) PLEASE ENSURE COMPLIANCE AND ENSURE MANUFACTURES | | SPECIFICATIONS ARE ONSITE FOR FIRE INSPECTOR REVIEW AND | | VERIFICATION. | | | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
Sent By |
Bwoods |
Date |
2018-12-06 |
Time |
00:00 |
Rev Time |
|
Received By |
|
Date |
2018-12-04 |
Time |
00:00 |
Sent To |
M |
|
Notes |
2018-12-06 14:25:09 | | | SHALL COMPLY WITH NFPA 24 | | 2013 EDITION | | | | 4.1.3 WORKING PLANS SHALL BE DRAWN TO AN INDICATED | | SCALE ON | | SHEETS OF UNIFORM SIZE, WITH A PLAN OF EACH FLOOR AS | | APPLICABLE, | | AND SHALL INCLUDE THE FOLLOWING ITEMS THAT PERTAIN TO | | THE DESIGN | | OF THE SYSTEM: | | (1) NAME OF OWNER | | (2) LOCATION, INCLUDING STREET ADDRESS | | (3) POINT OF COMPASS | | (4) A GRAPHIC REPRESENTATION OF THE SCALE USED ON ALL | | PLANS | | (5) NAME AND ADDRESS OF CONTRACTOR | | (6) SIZE AND LOCATION OF ALL WATER SUPPLIES | | (7) SIZE AND LOCATION OF STANDPIPE RISERS, HOSE | | OUTLETS, HAND | | HOSE, MONITOR NOZZLES, AND RELATED EQUIPMENT | | (8) THE FOLLOWING ITEMS THAT PERTAIN TO PRIVATE FIRE | | SERVICE | | MAINS: | | (A) SIZE | | (B) LENGTH | | (C) LOCATION | | (D) WEIGHT | | (E) MATERIAL | | (F) POINT OF CONNECTION TO CITY MAIN | | (G) SIZES, TYPES, AND LOCATIONS OF VALVES, VALVE | | INDICATORS, | | REGULATORS, METERS, AND VALVE PITS | | (H) DEPTH AT WHICH THE TOP OF THE PIPE IS LAID BELOW | | GRADE | | (I) METHOD OF RESTRAINT | | (9) THE FOLLOWING ITEMS THAT PERTAIN TO HYDRANTS: | | (A) SIZE AND LOCATION, INCLUDING SIZE AND NUMBER OF | | OUTLETS | | AND WHETHER OUTLETS ARE TO BE EQUIPPED WITH INDEPENDENT | | GATE VALVES | | (B) THREAD SIZE AND COUPLING ADAPTER SPECIFICATIONS IF | | DIFFERENT FROM NFPA 1963 | | (C) WHETHER HOSE HOUSES AND EQUIPMENT ARE TO BE | | PROVIDED, | | AND BY WHOM | | (D) STATIC AND RESIDUAL HYDRANTS USED IN FLOW | | (E) METHOD OF RESTRAINT | | (10) SIZE, LOCATION, AND PIPING ARRANGEMENT OF FIRE | | DEPARTMENT | | CONNECTIONS | | 4.1.4 THE WORKING PLAN SUBMITTAL SHALL INCLUDE THE | | MANUFACTURER?S | | INSTALLATION INSTRUCTIONS FOR ANY SPECIALLY LISTED | | EQUIPMENT, | | INCLUDING DESCRIPTIONS, APPLICATIONS, AND LIMITATIONS | | FOR | | ANY DEVICES, PIPING, OR FITTINGS. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2019-07-24 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2019-07-24 |
Time |
13:14 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2019-07-15 |
Time |
14:55 |
Sent To |
|
|
Notes |
2019-07-16 14:55:25 | RESUB ROUTED TO FIRE INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-07-10 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2019-07-10 |
Time |
10:54 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2019-06-25 |
Time |
13:49 |
Sent To |
|
|
Notes |
2019-06-27 13:50:02 | RESUB ROUTED TO FIRE INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-12-20 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2018-12-20 |
Time |
10:52 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2018-11-27 |
Time |
14:02 |
Sent To |
|
|
Notes |
2018-11-29 14:02:48 | ROUTED TO FIRE INBOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2019-07-23 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2019-07-23 |
Time |
10:53 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2019-07-23 |
Time |
10:53 |
Sent To |
ENG |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2019-07-08 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2019-07-08 |
Time |
15:54 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2019-07-08 |
Time |
15:01 |
Sent To |
ENG |
|
Notes |
2019-07-08 16:02:11 | 2ND REVIEW FBC-2017 MECHANICAL | | PERMIT #18111109 | | 7/8/19 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) AS PREVIOUSLY REQUESTED IN THE 1ST REVIEW, SUBMIT | | TWO SETS OF FULL-SIZE ORIGINAL SIGNED AND SEALED PLANS | | FOR THE FIRE LINE- REFER TO SECTION 107.2.1 WPB. THE | | COPIED SINGLE SET OF MASTER CIVL AND LANDSCAPING PLANS | | FOR THE PROJECT ARE NOT AN ACCEPTABLE SUBMITTAL FOR THE | | SEPARATE FIRE LINE PERMIT. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS. | | | | CHRISTOPHER L. COLE | | BUILDING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2018-12-19 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-12-19 |
Time |
15:45 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-12-19 |
Time |
15:45 |
Sent To |
ENG |
|
Notes |
2018-12-19 16:02:30 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT #18111109 | | 12/18/18 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) A FLORIDA UNDERGROUND UTILITY AND EXCAVATION | | CONTRACTOR MAY NOT INSTALL PIPING THAT IS AN INTEGRAL | | PART OF A FIRE PROTECTION SYSTEM AS DEFINED IN FL. | | STATUTES 633.021 BEGINNING AT THE POINT WHERE THE | | PIPING IS USED EXCLUSIVELY FOR SUCH SYSTEM. FOR THIS | | TYPE OF INSTALLATION A FLORIDA FIRE PROTECTION V | | CONTRACTOR LICENSE IS REQUIRED INSTEAD. | | | | 2) THE SUBMITTED SETS OF COPIED PLANS HAVE BEEN REDUCED | | IN SIZE AND ARE COMPLETELY ILLEGIBLE AND NOT ACCEPTABLE | | FOR REVIEW. PROVIDE CLEAR, LEGIBLE PLANS AT MINIMUM | | 1/8" SCALE THAT ALSO BEAR THE ORIGINAL SIGNATURE AND | | SEAL OF THE ENGINEER OF RECORD- SECTION 107.2.1 WPB AND | | SECTION 61G15- 23.002 FAC. | | | | 3) PROVIDE A PRODUCT SUBMITTAL PACKAGE THAT INCLUDES | | ALL COMPONENTS OF THE FIRE LINE ASSEMBLY INCLUDING THE | | PIPING, TEES, PLUGS, CAPS, REDUCERS, VALVES, AND ALL | | RESTRAINING DEVICES. PLEASE NOTE THAT MATERIAL DATA | | SHEETS WITH TORQUE WRENCH SETTINGS SHALL BE ONSITE AT | | TIME OF INSPECTION. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|