Plan Review Details - Permit 18110877
Plan Review Stops For Permit 18110877
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2019-03-19 Cont ID  
Sent By cthroop Date 2019-03-19 Time 17:15 Rev Time 0.00
Received By cthroop Date 2019-03-19 Time 16:33 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2019-02-06 Cont ID  
Sent By jduprey Date 2019-02-06 Time 16:32 Rev Time 0.00
Received By jduprey Date 2019-02-06 Time 16:24 Sent To  
Notes
2019-02-06 16:31:49BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 JOSEAN A. DUPREY E.I., BN, PX
 BUILDING PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6716
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. THE BUCK DETAIL WAS SUBMITTED, HOWEVER THE SIGNATURE
 IS A COPY. PLEASE SUBMITT A COPY WITH THE ORIGINAL
 SIGNATURE. ALSO THIS DETAIL MUST INCLUDE THE WIND
 DESIGN CRITERIA CONSIDERED BY THE ENGINEER.
 PLANS THAT HAVE BEEN PREPARED BY AN ENGINEER AND
 SUBMITTED FOR PUBLIC RECORD SHALL BEAR THE ORIGINAL
 SIGNATURE, DATE AND SEAL OF THE ENGINEER PER FL ADMIN.
 CODE RULE 61G15-23.001.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-12-21 Cont ID  
Sent By dbattles Date 2018-12-21 Time 16:34 Rev Time 0.00
Received By dbattles Date 2018-12-21 Time 10:06 Sent To  
Notes
2018-12-21 16:34:23****CORRECTIONS****
 W.P.B. PERMIT: 18110877
 REVIEWED: DECEMBER 21, 2018
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER I
 [email protected]
 561-805-6718
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC AMENDED = FLORIDA BUILDING CODE,6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC ENERGY = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. [FBC EXISTING 504.1]STATE THE LEVEL OF ALTERATION
 FOR WORK BEING PERFORMED. THIS LOOKS A LEVEL 2
 ALTERATION SINCE WALLS ARE BEING REMOVED.
  
 2. [FBC AMENDED 107.3.5]
 PROVIDE DESIGN DATA FOR OPENINGS
 WIND SPEED V ULT = (170)
 WIND SPEED V ASD = (132)
 EXPOSURE CATEGORY = B
 BUILDING CLASSIFICATION = ENCLOSED
 MEAN BLDG. HGT. = ?
 PLEASE PROVIDE AN OPENING SCHEDULE TO SHOW THE SIZES
 AND DESIGN PRESSURES.
 PRESSURES CAN BE USED FROM R301.2(2) WALL ZONE 4 OR 5
 AS APPROPRIATE.
  
 3. [FBC AMENDED 107.3.5]PROVIDE IN-FILL DETAIL WHERE
 CMU WALL IS BEING CLOSED UP. INCLUDE EXTERIOR FINISH,
 DOWELS AND INTERIOR INSULATION/FINISH.
  
 NOTE:
 -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
 -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW
 OF MATERIALS REQUESTED.
 -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS
 OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS)
 SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT
 DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER
 SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID"
 OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS
 APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE
 NEED "VOID", RENDERING THEM NOT USABLE.
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-02-07 Cont ID  
Sent By cthroop Date 2019-02-07 Time 15:53 Rev Time 0.00
Received By cthroop Date 2019-02-07 Time 14:22 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-12-12 Cont ID  
Sent By jpearson Date 2018-12-12 Time 13:56 Rev Time 0.00
Received By jpearson Date 2018-12-12 Time 07:57 Sent To  
Notes
2018-12-12 13:56:00CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PER THE WPB AMENDMENTS TO THE FBC, PLAN IS REQUIRED
 TO BE SIGNED BY PERSON RESPONSIBLE FOR THE DESIGN.
 PROVIDE CORRECTION. FS 481.229; WPB FBC 107.1, 107.2.1,
 107.3.5.1.2
 2. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT,
 SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN
 KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS,
 PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS,
 RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND
 SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. THIS
 INCLUDES LIGHTING AND POWER OUTLETS AND RECEPTACLES.
 SOME AREAS REQUIRE BOTH AFCI AND GFCI PROTECTION. IF
 EXISTING OUTLETS AND SWITCHES ARE REPLACED, AFCI AND
 GFCI TO CODE IS REQUIRED. PROVIDE CORRECTION. NEC
 210.8, 210.12, 406.4; FBC RE E3902; FBC EX 607.1.1 OR
 801.1, 801.2, OR 901.2 AS APPLICABLE.
 3. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC
 210.8(D); FBC RE E3902.10
 4. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED
 CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS,
 AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY
 WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5,
 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902
 5. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED
 PER CODE. PROVIDE FULL FLOOR PLAN SHOWING ALL EXISTING
 ALARMS. IF NONE ARE EXISTING OR NOT TO CODE, SHOW AS
 NEW INSTALLATIONS. FBC RE R314.3, R315.1; WPB FBC
 107.2.1
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop HIST HISTORICAL
Rev No 3 Status P Date 2019-03-14 Cont ID  
Sent By aborngra Date 2019-03-14 Time 14:03 Rev Time 0.00
Received By aborngra Date 2019-03-14 Time 14:03 Sent To M
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2019-02-11 Cont ID  
Sent By aborngra Date 2019-02-11 Time 14:53 Rev Time 0.00
Received By aborngra Date 2019-02-11 Time 14:52 Sent To PC
Notes
2019-02-11 14:53:12THE PERMIT HAS BEEN APPROVED WITH THE FOLLOWING
 CONDITIONS:
  
 1. ALL WINDOWS MUST FEATURE OGEE DIMENSIONAL MUNTINS.
 A. ALL SINGLE-HUNG WINDOWS WILL FEATURE A 6 OVER 1
 LAYOUT.
 B. ALL FIXED WINDOWS MUST COPY THE ORIGINAL MUNTIN
 LAYOUT FOUND IN THE ORIGINAL WINDOW.
 2. ALL REPLACEMENTS WINDOWS MUST FIT THE ORIGINAL
 WINDOW FRAME SIZE.
 3. ALL WINDOWS SHALL BE CLEAR GLASS OR LOW E.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE EMAIL AARON
 BORNGRABER AT [email protected] OR CALL 561-822-1428.
  
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER
 CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES
 T: 561-822-1428
 [email protected]
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2018-12-11 Cont ID  
Sent By aborngra Date 2018-12-11 Time 11:00 Rev Time 0.00
Received By aborngra Date 2018-12-11 Time 11:00 Sent To  
Notes
2018-12-11 11:00:39THE PERMIT HAS BEEN APPROVED WITH THE FOLLOWING
 CONDITIONS:
  
 1. ALL WINDOWS MUST FEATURE OGEE DIMENSIONAL MUNTINS.
 A. ALL SINGLE-HUNG WINDOWS WILL FEATURE A 6 OVER 1
 LAYOUT.
 B. ALL FIXED WINDOWS MUST COPY THE ORIGINAL MUNTIN
 LAYOUT FOUND IN THE ORIGINAL WINDOW.
 2. ALL REPLACEMENTS WINDOWS MUST FIT THE ORIGINAL
 WINDOW FRAME SIZE.
 3. A SEPARATE DRIVEWAY AND FENCE PERMIT IS REQUIRED FOR
 THE PROPOSED DRIVEWAY AND FENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE EMAIL AARON
 BORNGRABER AT [email protected] OR CALL 561-822-1428.
  
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER
 CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES
 T: 561-822-1428
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-03-19 Cont ID  
Sent By cthroop Date 2019-03-19 Time 17:22 Rev Time 0.00
Received By cthroop Date 2019-03-12 Time 13:14 Sent To  
Notes
2019-03-13 13:14:43R20

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-02-12 Cont ID  
Sent By cpuell Date 2019-02-12 Time 10:14 Rev Time 0.00
Received By cpuell Date 2019-01-31 Time 13:21 Sent To  
Notes
2019-02-01 13:21:47R33

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-12-27 Cont ID  
Sent By cthroop Date 2018-12-27 Time 17:08 Rev Time 0.00
Received By cthroop Date 2018-11-20 Time 16:08 Sent To  
Notes
2018-11-28 12:50:27R33
2018-11-20 16:08:58LIBRARY

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2019-03-19 Cont ID  
Sent By cthroop Date 2019-03-19 Time 17:15 Rev Time 0.00
Received By cthroop Date 2019-03-19 Time 16:33 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2019-02-14 Cont ID  
Sent By cthroop Date 2019-02-14 Time 11:36 Rev Time 0.00
Received By cthroop Date 2019-02-14 Time 11:36 Sent To  
Notes
2019-02-14 11:37:55MECHANICAL PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 3RD REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. SPCIFICATIONS FOR 2-TON UNIT WERE LOCATED IN PLAN.
  
 2. PROVIDE RETURN AIR FOR UPSTAIRS BEDROOMS.
 M1602.3 BALANCED RETURN AIR.
  
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2019-02-07 Cont ID  
Sent By cthroop Date 2019-02-07 Time 15:55 Rev Time 0.00
Received By cthroop Date 2019-02-07 Time 14:22 Sent To  
Notes
2019-02-07 16:00:59MECHANICAL PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 2ND REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE SPECIFICATIONS FOR 2 TON COND. UNIT.
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 2. PROVIDE RETURN AIR FOR UPSTAIRS BEDROOMS.
 M1602.3 BALANCED RETURN AIR.
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2018-12-19 Cont ID  
Sent By cmontell Date 2018-12-19 Time 09:41 Rev Time 0.00
Received By cmontell Date 2018-12-19 Time 09:38 Sent To  
Notes
2018-12-19 09:40:55MECHANICAL PLAN REVIEW FAIL
  
 1 - NEED LEGIBLE PLAN PER 2017 FLORIDA BUILDING CODE -
 BUILDING, SIXTH EDITION SEC. [A]107.2.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS.
  
 CHRIS MONTELLO
 561-805-6733
 [email protected]

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-02-07 Cont ID  
Sent By cthroop Date 2019-02-07 Time 15:53 Rev Time 0.00
Received By cthroop Date 2019-02-07 Time 14:22 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2018-12-27 Cont ID  
Sent By cthroop Date 2018-12-27 Time 16:31 Rev Time 0.00
Received By cthroop Date 2018-12-26 Time 12:27 Sent To  
Notes
2018-12-27 17:08:46PLUMBING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 DUE TO THE DEFICIENCIES OF THIS PLAN, A COMPLETE AND
 THOROUGH REVIEW CANNOT BE PERFORMED AT THIS TIME. UPON
 RE-SUBMITTAL, ADDITIONAL COMMENTS MAY BE MADE.
  
 PROVIDE CLARIFICATION FOR THE FOLLOWING:
  
 1. CLARIFY THE SCOPE OF WORK IN M-BATH. A. VANITY. B.
 WC. C. SHOWER.
  
 2. ARCH. FLOOR PLAN STATES EXISTING BUT SHOWS TANKLESS
 WATER HEATER LOCATED AT EXTERIOR WALL OF M-BATH. NOTE
 STATES WH WILL BE LOCATED BACK TO BACK OF OLD WH THAT
 WAS LOCATED IN KITCHEN. PLEASE CLARIFY.
  
 3. SHOW WATER CLOSETS ON PLAN.
  
 4. WHAT SIZE SANITARY SERVICES THE WC ON ISOMETRIC
 DRAWING?
  
 5. PROVIDE DEMENSIONS IN BATHROOMS TO VERIFY REQUIRED
 CLEARANCES.
  
 6. ARE BOTH SYSTEMS TIED TO BLDG. DRAIN OR BLDG. SEWER?
 IF SEPERATE SYSTEMS ARE TIED TO BLDG. SEWER THEN A
 SECOND VTR WILL BE REQUIRED.
  
 7. NOTE ON ELECTRICAL PLAN STATES RE-LOCATE WASHER AND
 DRYER. WHERE WILL THEY BE LOCATED?
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED.
  
  
  
  

Review Stop Z ZONING
Rev No 3 Status P Date 2019-03-14 Cont ID  
Sent By aborngra Date 2019-03-14 Time 14:03 Rev Time 0.00
Received By aborngra Date 2019-03-14 Time 14:03 Sent To PC
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2019-02-11 Cont ID  
Sent By aborngra Date 2019-02-11 Time 14:54 Rev Time 0.00
Received By aborngra Date 2019-02-11 Time 14:53 Sent To PC
Notes
2019-02-11 14:54:05THE PERMIT HAS BEEN APPROVED WITH THE FOLLOWING
 CONDITIONS:
  
 1. A SEPARATE DRIVEWAY PERMIT SHALL BE REQUIRED. A HOLD
 SHALL BE PLACED ON THE PERMIT, WHICH SHALL PREVENT THE
 CLOSEOUT OF THE PERMIT IF A DRIVEWAY PERMIT IS NOT
 SUBMITTED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE EMAIL AARON
 BORNGRABER AT [email protected] OR CALL 561-822-1428.
  
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER
 CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES
 T: 561-822-1428
 [email protected]
  

Review Stop Z ZONING
Rev No 1 Status F Date 2018-12-11 Cont ID  
Sent By aborngra Date 2018-12-11 Time 11:03 Rev Time 0.00
Received By aborngra Date 2018-12-11 Time 11:03 Sent To  
Notes
2018-12-11 11:04:15THE PERMIT HAS FAILED ZONING REVIEW FOR THE FOLLOWING
 REASIONS:
  
 1. A SEPARATE DRIVEWAY AND FENCE PERMIT IS REQUIRED FOR
 THE PROPOSED DRIVEWAY AND FENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE EMAIL AARON
 BORNGRABER AT [email protected] OR CALL 561-822-1428.
  
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER
 CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES
 T: 561-822-1428
 [email protected]