Plan Review Details - Permit 18110627
Plan Review Stops For Permit 18110627
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-01-24 Cont ID  
Sent By dbattles Date 2019-01-24 Time 13:03 Rev Time 0.00
Received By dbattles Date 2019-01-24 Time 12:53 Sent To  
Notes
2019-01-24 13:04:47PROVISO:
 PROVIDE PRODUCT APPROVALS FOR DOORS 101,102 AND 104 IN
 A SUBMITTAL, OR PROVIDE TO INSPECTOR IF THE INSPECTOR
 WILL ACCEPT THGEM IN THE FIELD.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-12-31 Cont ID  
Sent By dbattles Date 2018-12-31 Time 09:06 Rev Time 0.00
Received By dbattles Date 2018-12-28 Time 15:41 Sent To  
Notes
2018-12-31 09:07:43****CORRECTIONS****
 W.P.B. PERMIT: 18110627
 REVIEWED: DECEMBER 28, 2018
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER I
 [email protected]
 561-805-6718
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC AMENDED = FLORIDA BUILDING CODE,6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC ENERGY = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. [FBC ENERGY R401.2]PROVIDE ENERGY CALCULATIONS TO
 MEET REQUIREMENTS IN R401.2 RESIDENTIAL ENERGY CODE.
 CHOOSE METHOD IN R401.2 AND SUPPLY DOCUMENTATION.
 THE ENERGY CALCULATIONS IN SUPPORTING DOCUMENTS IS LOAD
 CALCS ONLY. PLEASE PROVIDE ADDITIONAL CALCULATIOND TO
 INCLUDE DATA USED TO DETERMINE HVAC LOAD CALCULATIONS.
  
 2. [FBC AMENDED 107.2.1.2]PROVIDE STAIRCASE AND GUARD
 RAIL ENGINEERING, OR INDICATE THAT IT WILL BE DEFERRED.
  
 3. [FBC AMENDED 107.3.4.1]PROVIDE PRODUCT APPROVALS FOR
 DOOR 101 103 AND 104, OR INDICATE THAT YOU WOULD LIKE
 IT DEFERED.
  
 NOTE:
 -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
 -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW
 OF MATERIALS REQUESTED.
 -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS
 OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS)
 SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT
 DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER
 SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID"
 OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS
 APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE
 NEED "VOID", RENDERING THEM NOT USABLE.
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-01-28 Cont ID  
Sent By jleahy Date 2019-01-28 Time 16:18 Rev Time 0.00
Received By jleahy Date 2019-01-28 Time 16:18 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-12-06 Cont ID  
Sent By jleahy Date 2018-12-06 Time 16:41 Rev Time 0.00
Received By jleahy Date 2018-12-06 Time 16:41 Sent To  
Notes
2018-12-06 16:41:19FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
  
 OUTLETS NEEDED AT THE FRONT AND REAR OF STRUCTURE.
 E3901.7 OUTDOOR OUTLETS.
 NOT LESS THAN ONE RECEPTACLE OUTLET THAT IS READILY
 ACCESSIBLE FROM GRADE LEVEL AND LOCATED NOT MORE THAN 6
 FEET, 6 INCHES (1981 MM) ABOVE GRADE, SHALL BE
 INSTALLED OUTDOORS AT THE FRONT AND BACK OF EACH
 DWELLING UNIT HAVING DIRECT ACCESS TO GRADE LEVEL.
 BALCONIES, DECKS, AND PORCHES THAT ARE ACCESSIBLE FROM
 INSIDE OF THE DWELLING UNIT SHALL HAVE AT LEAST ONE
 RECEPTACLE OUTLET INSTALLED WITHIN THE PERIMETER OF THE
 BALCONY, DECK, OR PORCH. THE RECEPTACLE SHALL BE
 LOCATED NOT MORE THAN 6 FEET, 6 INCHES (1981 MM) ABOVE
 THE BALCONY, DECK, OR PORCH SURFACE. [210.52(E)]
  
 STRUCTURE SHALL HAVE A GROUNDING SYSTEM INSTALLED PER
 E3607.3
 E3607.3 BUILDINGS OR STRUCTURES SUPPLIED BY FEEDER(S)
 OR BRANCH CIRCUIT(S).
 BUILDINGS OR STRUCTURES SUPPLIED BY FEEDER(S) OR BRANCH
 CIRCUIT(S) SHALL HAVE A GROUNDING ELECTRODE OR
 GROUNDING ELECTRODE SYSTEM INSTALLED IN ACCORDANCE WITH
 SECTION E3608. THE GROUNDING ELECTRODE CONDUCTOR(S)
 SHALL BE CONNECTED IN A MANNER SPECIFIED IN SECTION
 E3607.3.1 OR, FOR EXISTING PREMISES WIRING SYSTEMS
 ONLY, SECTION E3607.3.2. WHERE THERE IS NO EXISTING
 GROUNDING ELECTRODE, THE GROUNDING ELECTRODE(S)
 REQUIRED IN SECTION E3608 SHALL BE INSTALLED.
 [250.32(A)]
  
 MAINS NEED TO BE GROUPED
 E3601.6 SERVICE DISCONNECT REQUIRED.
 MEANS SHALL BE PROVIDED TO DISCONNECT ALL CONDUCTORS IN
 A BUILDING OR OTHER STRUCTURE FROM THE SERVICE ENTRANCE
 CONDUCTORS. (230.70)
  
 SMOKE ALARMS
 R314.2.2 ALTERATIONS, REPAIRS AND ADDITIONS.
 WHERE ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A
 PERMIT OCCUR, OR WHERE ONE OR MORE SLEEPING ROOMS ARE
 ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL
 DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS
 LOCATED AS REQUIRED FOR NEW DWELLINGS.
 EXCEPTIONS:
 1.WORK INVOLVING THE EXTERIOR SURFACES OF DWELLINGS,
 SUCH AS THE REPLACEMENT OF ROOFING OR SIDING, THE
 ADDITION OR REPLACEMENT OF WINDOWS OR DOORS, OR THE
 ADDITION OF A PORCH OR DECK, ARE EXEMPT FROM THE
 REQUIREMENTS OF THIS SECTION.
 2.INSTALLATION, ALTERATION OR REPAIRS OF PLUMBING OR
 MECHANICAL SYSTEMS ARE EXEMPT FROM THE REQUIREMENTS OF
 THIS SECTION

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2018-12-18 Cont ID  
Sent By fmittner Date 2018-12-18 Time 08:40 Rev Time 0.00
Received By fmittner Date 2018-12-18 Time 08:40 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-01-28 Cont ID  
Sent By jleahy Date 2019-01-28 Time 16:19 Rev Time 0.00
Received By jleahy Date 2019-01-18 Time 15:26 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-01-10 Cont ID  
Sent By gjohnson Date 2019-01-10 Time 10:26 Rev Time 0.00
Received By gjohnson Date 2018-12-03 Time 08:59 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2019-02-01 Cont ID  
Sent By lmarchan Date 2019-02-01 Time 14:00 Rev Time 0.00
Received By lmarchan Date 2019-01-29 Time 10:52 Sent To  
Notes
2019-02-01 14:00:30RECEIPT MU-2019-3226 - $0.00 DUE
  
2019-01-29 10:52:181/29/19 EMAILED IMPACT FEE OFFICE FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2018-12-31 Cont ID  
Sent By dbattles Date 2018-12-31 Time 09:15 Rev Time 0.00
Received By dbattles Date 2018-12-31 Time 09:15 Sent To  
Notes
2018-12-31 09:17:14[FBC AMENDED 109]PLANS WILL BE REVIEWED BY THE PBC
 IMPACT FEE OFFICE DIGITALLY VIA PROJECTDOX UPON
 NOTIFICATION BY THIS OFFICE. NOTIFICATION MAY OCCUR
 WHEN PLANS ARE NEAREST FINAL FORM. YOU MAY COORDINATE
 WITH THE IMPACT FEE OFFICE AT (561) 233-5025 OR SIMPLY
 UPLOAD THE MUNICIPAL IMPACT FEE QUESTIONNAIRE FORM TO
 YOUR PROJECT AND NAME THE FILE MUNICIPAL IMPACT FEE
 QUESTIONNAIRE. THE FORM CAN BE FOUND AT: HTTP://DISCOVE
 R.PBCGOV.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QU
 ESTIONNAIRE.PDF UPON APPROVAL AND FEE PAYMENT, PLEASE
 UPLOAD THE RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected]
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER I
 [email protected]
 561-805-6718
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2019-01-02 Cont ID  
Sent By hmoser Date 2019-01-02 Time 14:32 Rev Time 0.00
Received By hmoser Date 2019-01-02 Time 13:51 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-01-26 Cont ID  
Sent By gjohnson Date 2019-01-26 Time 10:23 Rev Time 0.00
Received By gjohnson Date 2019-01-26 Time 10:23 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-01-10 Cont ID  
Sent By gjohnson Date 2019-01-10 Time 10:26 Rev Time 0.00
Received By gjohnson Date 2019-01-10 Time 09:39 Sent To  
Notes
2019-01-10 10:25:581ST REVIEW:
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1. THE ADDRESS ON THE PLAN SHEETS IS 221 EDGEWOOD DR
 THIS IS INCORRECT THAT ADDRESS DOES NOT EXIST THE
 PERMIT APPLICATION STATES THE ADDRESS AS 215 PLEASE
 CORRECT ON PLAN SHEETS. PER FBC AMEND TO FBC 107.2.1
 2. I COULD NOT LOCATE THE MASTER BUILDING PERMIT
 APPLICATION IT APPEARS THAT IT DID NOT GET UPLOADED
 PLEASE CLARIFY. PER FBC AMEND TO FBC 107.2.1
 3. A CLEAN OUT IS REQUIRED ANY BRANCH OF THE BUILDING
 DRAIN EXISTS THE BUILDING AND CONNECTS TO THE BUILDING
 SEWER PLEASE SHOW ON ISOMETRIC DRAWING. PER FBC RES
 P3005.2.3
 4. PLEASE PLACE NOTE ON THE PLANS. [THE SHUT OF VALVES
 FOR THE STACKABLE WASHING MACHINE SHALL BE ACCESSIBLE
 PER FBC RES P2903.9.3] [THE WATER HEATER AND PIPING
 SHALL COMPLY WITH THE FBC ENERGY R403.5]
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2019-01-28 Cont ID  
Sent By jleahy Date 2019-01-28 Time 16:19 Rev Time 0.00
Received By jleahy Date 2019-01-28 Time 16:19 Sent To  
Notes
2019-01-26 10:23:461/26/19 DIG SIG ON PLUMB OK/GPJ

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2018-12-31 Cont ID  
Sent By dbattles Date 2018-12-31 Time 09:08 Rev Time 0.00
Received By dbattles Date 2018-12-31 Time 09:07 Sent To  
Notes
2018-12-31 09:09:05INITIAL REVIEW - ALL SHEETS OK
 ANY NEW SHEETS SUBMITTED WILL NEED TO BE DIGITALLY
 SIGNED.
  

Review Stop Z ZONING
Rev No 1 Status P Date 2018-12-18 Cont ID  
Sent By mcurz Date 2018-12-18 Time 08:40 Rev Time 0.00
Received By fmittner Date 2018-12-18 Time 08:40 Sent To  
Notes
***NONE***