Plan Review Details - Permit 18110485
Plan Review Stops For Permit 18110485
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2019-01-24 Cont ID  
Sent By pvalenti Date 2019-01-24 Time 17:09 Rev Time 0.00
Received By pvalenti Date 2019-01-24 Time 17:05 Sent To  
Notes
2019-01-24 17:17:24PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 APPROVED
  
 NOTES:
  
 IF WELDING CONNECTIONS ARE TAKING PLACE IN THE FIELD,
 AT TIME OF INSPECTION PROVIDE:
  
 1. A WELD PROCEDURE SPECIFICATION FOR WELDED
 CONNECTIONS. A.W.S SECTION/CLAUSE 3.1
  
 2. A PERFORMANCE QUALIFICATION RECORD FOR THE WELDING
 PERSONNEL. A.W.S SECTION/CLAUSE 4.2.2
2019-01-24 17:06:47PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2019-01-04 Cont ID  
Sent By pvalenti Date 2019-01-04 Time 08:47 Rev Time 0.00
Received By pvalenti Date 2019-01-04 Time 08:46 Sent To  
Notes
2019-01-04 08:55:37****CORRECTIONS****
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561?805?6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 THIS IS THE SECOND BUILDING PLAN REVIEW. PLEASE RESPOND
 TO THE ITEMS LISTED BELOW.
  
 FBC 107. PLEASE PROVIDE MORE INFORMATION:
  
 1. DESIGN PROFESSIONAL?S (ENGINEER) SIGNATURE & SEAL
 ARE MISSING FROM PLANS.
 2. THE CONCRETE FOOTINGS AND PAD ARE MISSING DIMENSIONS
 AND REINFORCEMENT/CRACK PREVENTION INFORMATION.
 3. THE STRUCTURAL CONNECTIONS ARE NOT COMPLETE :
 A. A.W.S SECTION/CLAUSE 3.1 PROVIDE A WELD PROCEDURE
 SPECIFICATION FOR WELDED CONNECTIONS.
 B. A.W.S SECTION/CLAUSE 4.2.2 PROVIDE WELDERS
 PERFORMANCE QUALIFICATION RECORD FOR THE WELDING
 PERSONNEL.
 C. IN THE CASE THAT SOME OF THE DESCRIBED WELD
 CONNECTIONS ARE TO BE BOLTED AND/OR SCREWED, PROVIDE
 DETAILS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-11-30 Cont ID  
Sent By jduprey Date 2018-11-30 Time 07:06 Rev Time 0.00
Received By pvalenti Date 2018-11-30 Time 07:06 Sent To  
Notes
2018-11-30 07:38:41****CORRECTIONS****
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 FBC 107. PLEASE PROVIDE MORE INFORMATION:
  
 1. DESIGN PROFESSIONAL'S (ENGINEER) SIGNATURE & SEAL
 ARE MISSING FROM PLANS.
 2. THE CONCRETE FOOTINGS AND PAD ARE MISSING DIMENSIONS
 AND REINFORCEMENT/CRACK PREVENTION INFORMATION.
 3. THE STRUCTURAL CONNECTIONS ARE NOT COMPLETE :
 A. A.W.S SECTION/CLAUSE 3.1 PROVIDE A WELD PROCEDURE
 SPECIFICATION FOR WELDED CONNECTIONS.
 B. A.W.S SECTION/CLAUSE 4.2.2 PROVIDE WELDERS
 PERFORMANCE QUALIFICATION RECORD FOR THE WELDING
 PERSONNEL.
 C. IN THE CASE THAT SOME OF THE DESCRIBED WELD
 CONNECTIONS ARE TO BE BOLTED AND/OR SCREWED, PROVIDE
 DETAILS.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2019-07-19 Cont ID  
Sent By cpuell Date 2019-07-19 Time 15:01 Rev Time 0.00
Received By cpuell Date 2019-07-08 Time 14:30 Sent To  
Notes
2019-07-18 14:26:21ROUTED FROM ZONING TO PERMIT LIBRARIAN 7/18/19 EL
2019-07-09 14:30:50RESUB ROUTED TO ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-01-25 Cont ID  
Sent By cpuell Date 2019-01-25 Time 10:32 Rev Time  
Received By cpuell Date 2019-01-17 Time 13:46 Sent To  
Notes
2019-01-24 09:43:25ROUTED FROM ZONING TO PERMIT LIBRARIAN 1/24/19 EL
2019-01-18 13:46:53RESUB ROUTED TO ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-01-04 Cont ID  
Sent By pvalenti Date 2019-01-04 Time 08:56 Rev Time 0.00
Received By pvalenti Date 2018-12-21 Time 14:38 Sent To  
Notes
2019-01-02 15:47:42ROUTED FROM ZONING TO PERMIT LIBRARIAN 1/2/2019 EL
2018-12-26 14:38:27RESUB ROUTED TO ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-11-30 Cont ID  
Sent By jduprey Date 2018-11-30 Time 07:39 Rev Time 0.00
Received By pvalenti Date 2018-11-13 Time 11:12 Sent To I
Notes
2018-11-16 10:29:44ROUTED FROM ZONING TO LM 11/16/18
2018-11-14 11:12:18ROUTED TO ZONING INBOX

Review Stop Z ZONING
Rev No 4 Status P Date 2019-07-18 Cont ID  
Sent By elevesqu Date 2019-07-18 Time 14:25 Rev Time 0.00
Received By elevesqu Date 2019-07-18 Time 14:25 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status F Date 2019-01-24 Cont ID  
Sent By elevesqu Date 2019-01-24 Time 09:43 Rev Time 0.00
Received By elevesqu Date 2019-01-24 Time 09:42 Sent To B
Notes
2019-01-24 09:43:01THE RESTATED UNITY OF TITLE COMBINED NONCONTIGUOUS LOTS
 AND WAS NOT A LEGAL MEANS OF COMBINING LOTS.
  
 A SEPARATE MODIFIED UNITY OF TITLE FOR LOTS 8-11 SHOULD
 BE SUBMITTED TO THE CITY?S ENGINEERING DEPARTMENT FOR
 REVIEW.
  
 LIZ LEVESQUE, URBAN DESIGN PLANNER
 561 822 1426
 [email protected]
  
  

Review Stop Z ZONING
Rev No 2 Status F Date 2019-01-02 Cont ID  
Sent By elevesqu Date 2019-01-02 Time 15:47 Rev Time 0.00
Received By elevesqu Date 2019-01-02 Time 15:46 Sent To B
Notes
2019-01-02 15:47:08PREVIOUS COMMENT NOT ADDRESSED:
  
 SIGN MUST BE LOCATED ON THE LOT OF THE PRINCIPAL
 STRUCTURE PER SECTION 94-110(E). SIGN SHALL BE LOCATED
 A MINIMUM OF TEN FEET FROM ANY LOT LINE.
  
 LIZ LEVESQUE, URBAN DESIGN PLANNER
 [email protected]
 561 822 1426
  
  
  
  
  
 ROUTED TO EL

Review Stop Z ZONING
Rev No 1 Status F Date 2018-11-16 Cont ID  
Sent By elevesqu Date 2018-11-16 Time 10:26 Rev Time  
Received By elevesqu Date   Time   Sent To B
Notes
2018-11-16 10:26:17SIGN MUST BE LOCATED ON THE LOT OF THE PRINCIPAL
 STRUCTURE PER SECTION 94-110(E). SIGN SHALL BE LOCATED
 A MINIMUM OF TEN FEET FROM ANY LOT LINE.
  
 SIGN CANNOT EXCEED FOUR FEET IN HEIGHT INCLUDING BASE.
 PLEASE ADJUST AS NECESSARY AND PROVIDE HEIGHT DIMENSION
 IN FEET NOT INCHES.
 SIGN FACE AREA CANNOT EXCEED 16 SF. PLEASE ADJUST AS
 NECESARY.
  
 LIZ LEVESQUE, URBAN DESIGN PLANNER
 [email protected]
 561 822 1426
  
  
  
  
  
2018-11-15 16:32:13ROUTED TO EL