Plan Review Stops For Permit 18110485 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2019-01-24 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2019-01-24 |
Time |
17:09 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2019-01-24 |
Time |
17:05 |
Sent To |
|
|
Notes |
2019-01-24 17:17:24 | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | APPROVED | | | | NOTES: | | | | IF WELDING CONNECTIONS ARE TAKING PLACE IN THE FIELD, | | AT TIME OF INSPECTION PROVIDE: | | | | 1. A WELD PROCEDURE SPECIFICATION FOR WELDED | | CONNECTIONS. A.W.S SECTION/CLAUSE 3.1 | | | | 2. A PERFORMANCE QUALIFICATION RECORD FOR THE WELDING | | PERSONNEL. A.W.S SECTION/CLAUSE 4.2.2 | 2019-01-24 17:06:47 | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2019-01-04 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2019-01-04 |
Time |
08:47 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2019-01-04 |
Time |
08:46 |
Sent To |
|
|
Notes |
2019-01-04 08:55:37 | ****CORRECTIONS**** | | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561?805?6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | THIS IS THE SECOND BUILDING PLAN REVIEW. PLEASE RESPOND | | TO THE ITEMS LISTED BELOW. | | | | FBC 107. PLEASE PROVIDE MORE INFORMATION: | | | | 1. DESIGN PROFESSIONAL?S (ENGINEER) SIGNATURE & SEAL | | ARE MISSING FROM PLANS. | | 2. THE CONCRETE FOOTINGS AND PAD ARE MISSING DIMENSIONS | | AND REINFORCEMENT/CRACK PREVENTION INFORMATION. | | 3. THE STRUCTURAL CONNECTIONS ARE NOT COMPLETE : | | A. A.W.S SECTION/CLAUSE 3.1 PROVIDE A WELD PROCEDURE | | SPECIFICATION FOR WELDED CONNECTIONS. | | B. A.W.S SECTION/CLAUSE 4.2.2 PROVIDE WELDERS | | PERFORMANCE QUALIFICATION RECORD FOR THE WELDING | | PERSONNEL. | | C. IN THE CASE THAT SOME OF THE DESCRIBED WELD | | CONNECTIONS ARE TO BE BOLTED AND/OR SCREWED, PROVIDE | | DETAILS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2018-11-30 |
|
|
Cont ID |
|
Sent By |
jduprey |
Date |
2018-11-30 |
Time |
07:06 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2018-11-30 |
Time |
07:06 |
Sent To |
|
|
Notes |
2018-11-30 07:38:41 | ****CORRECTIONS**** | | | | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | FBC 107. PLEASE PROVIDE MORE INFORMATION: | | | | 1. DESIGN PROFESSIONAL'S (ENGINEER) SIGNATURE & SEAL | | ARE MISSING FROM PLANS. | | 2. THE CONCRETE FOOTINGS AND PAD ARE MISSING DIMENSIONS | | AND REINFORCEMENT/CRACK PREVENTION INFORMATION. | | 3. THE STRUCTURAL CONNECTIONS ARE NOT COMPLETE : | | A. A.W.S SECTION/CLAUSE 3.1 PROVIDE A WELD PROCEDURE | | SPECIFICATION FOR WELDED CONNECTIONS. | | B. A.W.S SECTION/CLAUSE 4.2.2 PROVIDE WELDERS | | PERFORMANCE QUALIFICATION RECORD FOR THE WELDING | | PERSONNEL. | | C. IN THE CASE THAT SOME OF THE DESCRIBED WELD | | CONNECTIONS ARE TO BE BOLTED AND/OR SCREWED, PROVIDE | | DETAILS. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2019-07-19 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2019-07-19 |
Time |
15:01 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2019-07-08 |
Time |
14:30 |
Sent To |
|
|
Notes |
2019-07-18 14:26:21 | ROUTED FROM ZONING TO PERMIT LIBRARIAN 7/18/19 EL | 2019-07-09 14:30:50 | RESUB ROUTED TO ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2019-01-25 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2019-01-25 |
Time |
10:32 |
Rev Time |
|
Received By |
cpuell |
Date |
2019-01-17 |
Time |
13:46 |
Sent To |
|
|
Notes |
2019-01-24 09:43:25 | ROUTED FROM ZONING TO PERMIT LIBRARIAN 1/24/19 EL | 2019-01-18 13:46:53 | RESUB ROUTED TO ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-01-04 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2019-01-04 |
Time |
08:56 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2018-12-21 |
Time |
14:38 |
Sent To |
|
|
Notes |
2019-01-02 15:47:42 | ROUTED FROM ZONING TO PERMIT LIBRARIAN 1/2/2019 EL | 2018-12-26 14:38:27 | RESUB ROUTED TO ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-11-30 |
|
|
Cont ID |
|
Sent By |
jduprey |
Date |
2018-11-30 |
Time |
07:39 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2018-11-13 |
Time |
11:12 |
Sent To |
I |
|
Notes |
2018-11-16 10:29:44 | ROUTED FROM ZONING TO LM 11/16/18 | 2018-11-14 11:12:18 | ROUTED TO ZONING INBOX |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2019-07-18 |
|
|
Cont ID |
|
Sent By |
elevesqu |
Date |
2019-07-18 |
Time |
14:25 |
Rev Time |
0.00 |
Received By |
elevesqu |
Date |
2019-07-18 |
Time |
14:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2019-01-24 |
|
|
Cont ID |
|
Sent By |
elevesqu |
Date |
2019-01-24 |
Time |
09:43 |
Rev Time |
0.00 |
Received By |
elevesqu |
Date |
2019-01-24 |
Time |
09:42 |
Sent To |
B |
|
Notes |
2019-01-24 09:43:01 | THE RESTATED UNITY OF TITLE COMBINED NONCONTIGUOUS LOTS | | AND WAS NOT A LEGAL MEANS OF COMBINING LOTS. | | | | A SEPARATE MODIFIED UNITY OF TITLE FOR LOTS 8-11 SHOULD | | BE SUBMITTED TO THE CITY?S ENGINEERING DEPARTMENT FOR | | REVIEW. | | | | LIZ LEVESQUE, URBAN DESIGN PLANNER | | 561 822 1426 | | [email protected] | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2019-01-02 |
|
|
Cont ID |
|
Sent By |
elevesqu |
Date |
2019-01-02 |
Time |
15:47 |
Rev Time |
0.00 |
Received By |
elevesqu |
Date |
2019-01-02 |
Time |
15:46 |
Sent To |
B |
|
Notes |
2019-01-02 15:47:08 | PREVIOUS COMMENT NOT ADDRESSED: | | | | SIGN MUST BE LOCATED ON THE LOT OF THE PRINCIPAL | | STRUCTURE PER SECTION 94-110(E). SIGN SHALL BE LOCATED | | A MINIMUM OF TEN FEET FROM ANY LOT LINE. | | | | LIZ LEVESQUE, URBAN DESIGN PLANNER | | [email protected] | | 561 822 1426 | | | | | | | | | | | | ROUTED TO EL |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2018-11-16 |
|
|
Cont ID |
|
Sent By |
elevesqu |
Date |
2018-11-16 |
Time |
10:26 |
Rev Time |
|
Received By |
elevesqu |
Date |
|
Time |
|
Sent To |
B |
|
Notes |
2018-11-16 10:26:17 | SIGN MUST BE LOCATED ON THE LOT OF THE PRINCIPAL | | STRUCTURE PER SECTION 94-110(E). SIGN SHALL BE LOCATED | | A MINIMUM OF TEN FEET FROM ANY LOT LINE. | | | | SIGN CANNOT EXCEED FOUR FEET IN HEIGHT INCLUDING BASE. | | PLEASE ADJUST AS NECESSARY AND PROVIDE HEIGHT DIMENSION | | IN FEET NOT INCHES. | | SIGN FACE AREA CANNOT EXCEED 16 SF. PLEASE ADJUST AS | | NECESARY. | | | | LIZ LEVESQUE, URBAN DESIGN PLANNER | | [email protected] | | 561 822 1426 | | | | | | | | | | | 2018-11-15 16:32:13 | ROUTED TO EL |
|
|