Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-02-26 Cont ID  
Sent By dbattles Date 2019-02-26 Time 16:07 Rev Time 0.00
Received By dbattles Date 2019-02-26 Time 13:53 Sent To  
Notes
2019-02-26 16:11:27PROVISO:
 1. RAILS AND GUARDS.
 2. STAIRCASE ENGINEERING.
 3. PROVIDE PRODUCT APPROVAL FOR EXTERIOR DOOR - SHEET
 A5.0 INDICATES THAT IT WILL BE FL-16-1206.04

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-01-18 Cont ID  
Sent By dbattles Date 2019-01-18 Time 11:26 Rev Time 0.00
Received By dbattles Date 2019-01-15 Time 13:31 Sent To  
Notes
2019-01-18 11:30:27****CORRECTIONS****
 W.P.B. PERMIT: 18110465
 REVIEWED: JANUARY 16, 2019
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER I
 [email protected]
 561-805-6718
  
 FBC[AMENDED] = FLORIDA BUILDING CODE,6TH EDITION (2017)
 FBC[B] = FBC BUILDING
 FBC[EXISTING] = FBC EXISTING BUILDING
 FBC[A] = FBC ACCESSIBILITY
 FBC[E] = FBC ENERGY CONSERVATION
 FBC[R] = FBC RESIDENTIAL
  
 1. 107.3.5 FBC[AMENDED] INDEX DOESN?T MATCH CIVIL PLAN
 UPLOADED.
 PLEASE UPDATE INDEX TO MATCH THREE SHEETS PROVIDED FOR
 CIVIL.
 ALSO, MECHANICAL SHEETS AS NEEDED FOR MECHANICAL REVIEW
 COMMENTS.
  
 2. 301.1 FBC[EXISTING] GENERAL. THE REPAIR, ALTERATION,
 CHANGE OF OCCUPANCY, ADDITION OR RELOCATION OF ALL
 EXISTING BUILDINGS SHALL COMPLY WITH ONE OF THE METHODS
 LISTED IN SECTIONS 301.1.1 THROUGH
 301.1.3 AS SELECTED BY THE APPLICANT. SECTIONS 301.1.1
 THROUGH 301.1.3 SHALL NOT BE APPLIED IN COMBINATION
 WITH EACH OTHER.
 -WHICH METHOD IS BEING USED FOR COMPLIANCE? PLEASE ADD
 TO COVER SHEET DATA(PRESCRIPTIVE,WORK AREA OR
 PERFORMANCE)
  
 3. 107.5.3 FBC[AMENDED] IS THE BUILDING SPRINKLERED OR
 NON SPRINKLERED?
 -PLEASE PROVIDE NOTE IN COVER SHEET DATA.
  
 4. 206.1 FBC[A] GENERAL. ACCESSIBLE ROUTE.
 SHOW ACCESSIBLE ROUTE FROM PARKING TO ACCESSIBLE ENTRY.
  
 5. 1012.2 FBC[B] SLOPE. RAMPS USED AS PART OF A MEANS
 OF EGRESS SHALL HAVE A RUNNING SLOPE NOT STEEPER THAN
 ONE UNIT VERTICAL IN 12 UNITS HORIZONTAL (8-PERCENT
 SLOPE).
 PLEASE ADD SLOPE INDICATION ON RAMP.
 ALSO, ADD DIMENSIONS TO RAMP.
  
 6. 1012.6.1 FBC[B] SLOPE. LANDINGS SHALL HAVE A SLOPE
 NOT STEEPER THAN ONE UNIT VERTICAL IN 48 UNITS
 HORIZONTAL (2-PERCENT SLOPE) IN ANY DIRECTION. CHANGES
 IN LEVEL ARE NOT PERMITTED.
 -ADD SLOPE INDICATION ON RAMP LANDINGS.
  
 7. 1012.10 FBC[B] EDGE PROTECTION. EDGE PROTECTION
 COMPLYING WITH SECTION 1012.10.1 OR 1012.10.2 SHALL BE
 PROVIDED ON EACH SIDE OF RAMP RUNS AND AT EACH SIDE OF
 RAMP LANDINGS. (SEE EXCEPTIONS)
 PROVIDE CROSS SECTION OF RAMP TO SHOW HOW EDGE
 PROTECTION IS ACHIEVED.
  
 8. 107.2.1.2 FBC[AMENDED] PROVIDE GUARD RAIL
 ENGINEERING, OR INDICATE THAT IT WILL BE DEFERRED.
  
 9. 107.2.1.2 FBC[AMENDED] PROVIDE STAIRCASE
 ENGINEERING, OR INDICATE THAT IT WILL BE DEFERRED.
  
 10. 107.3.4.1 FBC[AMENDED] PROVIDE PRODUCT APPROVALS
 FOR WINDOWS AND DOORS, OR INDICATE THAT YOU WOULD LIKE
 THEM DEFERED.
 SHEET A5.0 SHOWS ONE PRODUCT APPROVAL NUMBER FOR
 EXTERIOR DOOR FL-16-1206.04.
 A. IF THIS IS BEING USED PLEASE UPLOAD THE PRODUCT
 APPROVAL TO PROJECT DOX SUPPORTING DOCUMENTS.
 B. ARE ANY WINDOWS BEING REPLACED, OR ARE THEY JUST TO
 BE COVERED. PLEASE PROVIDE ANY APPLICABLE PRODUCT
 APPROVALS IN SUPPORTING DOCUMENTS.
 11. 1014.6 FBC[B] HANDRAIL EXTENSIONS. HANDRAILS SHALL
 RETURN TO A WALL, GUARD OR THE WALKING SURFACE OR SHALL
 BE CONTINUOUS TO THE HANDRAIL OF AN ADJACENT FLIGHT OF
 STAIRS OR RAMP RUN. WHERE HANDRAILS ARE NOT CONTINUOUS
 BETWEEN FLIGHTS, THE HANDRAILS SHALL EXTEND
 HORIZONTALLY NOT LESS THAN 12 INCHES (305 MM) BEYOND
 THE TOP RISER AND CONTINUE TO SLOPE FOR THE DEPTH OF
 ONE TREAD BEYOND THE BOTTOM RISER. AT RAMPS WHERE
 HANDRAILS ARE NOT CONTINUOUS BETWEEN RUNS, THE
 HANDRAILS SHALL EXTEND HORIZONTALLY ABOVE THE LANDING
 12 INCHES (305 MM) MINIMUM BEYOND THE TOP AND BOTTOM OF
 RAMP RUNS. THE EXTENSIONS OF HANDRAILS SHALL BE IN THE
 SAME DIRECTION OF THE FLIGHTS OF STAIRS AT STAIRWAYS
 AND THE RAMP RUNS AT RAMPS. (SEE 1415.6 FOR EXCEPTIONS
 AND REQUIREMENTS)
 -REVIEW HANDRAIL EXTENSIONS AT NEW STAGE STAIRS.
  
 12. 407.1 FBC[A] GENERAL. ELEVATORS SHALL COMPLY WITH
 407 AND WITH ASME A17.1 (INCORPORATED BY REFERENCE, SEE
 ?REFERENCED STANDARDS? IN CHAPTER 1). THEY SHALL BE
 PASSENGER ELEVATORS AS CLASSIFIED BY ASME A17.1.
 ELEVATOR OPERATION SHALL BE AUTOMATIC.
  
 13. 1003.7 FBC[B] ELEVATORS, ESCALATORS AND MOVING
 WALKS. ELEVATORS, ESCALATORS AND MOVING WALKS SHALL NOT
 BE USED AS A COMPONENT OF A REQUIRED MEANS OF EGRESS
 FROM ANY OTHER PART OF THE BUILDING. EXCEPTION:
 ELEVATORS USED AS AN ACCESSIBLE MEANS OF EGRESS IN
 ACCORDANCE WITH SECTION 1009.
  
 14. 2702.2.2 FBC[B] ELEVATORS AND PLATFORM LIFTS.
 STANDBY POWER SHALL BE PROVIDED FOR ELEVATORS AND
 PLATFORM LIFTS AS REQUIRED IN SECTIONS 1009.4, 1009.5,
 3003.1, 3007.8 AND 3008.8.
 IF ELEVATOR IS BEING USED FOR ACCESSIBLE MEANS OF
 EGRESS, HOW IS BACK-UP POWER BEING SUPPLIED?
 OTHERWISE, PLEASE PROVIDE ALTERNATIVE ACCESSIBLE PATH
 OF EGRESS FROM SECOND FLOOR SPACE.
  
 15. 3003.1 FBC[B] STANDBY POWER. IN BUILDINGS AND
 STRUCTURES WHERE STANDBY POWER IS REQUIRED OR FURNISHED
 TO OPERATE AN ELEVATOR, THE OPERATION SHALL BE IN
 ACCORDANCE WITH SECTIONS 3003.1.1 THROUGH 3003.1.4.
  
 16. 407.4.1 FBC[A] CAR DIMENSIONS. INSIDE DIMENSIONS OF
 ELEVATOR CARS AND CLEAR WIDTH OF ELEVATOR DOORS SHALL
 COMPLY WITH TABLE 407.4.1.
 -PLEASE ADD CAB DIMENSIONS AND TURNING SPACE ON PLANS.
  
 17. ASCE 7-10 SECTION 4.5.1 LOADS ON HANDRAIL AND
 GUARDRAIL SYSTEMS.
 -PROVIDE ENGINEERING FOR THE RAIL AT PULPIT, OR
 INDICATE THAT IT WILL BE A DEFERRED SUBMITTAL.
  
 18. 1609.1 FBC[B] APPLICATIONS. BUILDINGS, STRUCTURES
 AND PARTS THEREOF SHALL BE DESIGNED TO WITHSTAND THE
 MINIMUM WIND LOADS PRESCRIBED HEREIN.
 -PLEASE PROVIDE ENGINEERING TO SHOW HOW LEXAN PANELS
 MEET PRESSURES BASED ON SPAN, EDGE DISTANCE AND GLASS
 SEPARATION.
  
 NOTE:
 -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
 -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW
 OF MATERIALS REQUESTED.
 -IF ANY SPEC SHEETS OR PRDUCT APPROVALS ARE ADDED,
 PLEASE UPLOAD THEM AS MULTIPAGE FORMAT PDF IN
 SUPPORTING DOCUMENTS.
 -DIGITAL RESUBMITTAL UPON ALL REVIEWS COMPLETED.
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-03-19 Cont ID  
Sent By jpearson Date 2019-03-19 Time 13:40 Rev Time 0.00
Received By jpearson Date 2019-03-19 Time 13:10 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2019-01-08 Cont ID  
Sent By jleahy Date 2019-01-08 Time 16:17 Rev Time 0.00
Received By jleahy Date 2019-01-04 Time 16:16 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2019-02-22 Cont ID  
Sent By scaldero Date 2019-02-22 Time 13:19 Rev Time 0.00
Received By scaldero Date 2019-02-22 Time 13:15 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2018-12-17 Cont ID  
Sent By scaldero Date 2018-12-17 Time 11:39 Rev Time 0.00
Received By scaldero Date 2018-12-14 Time 10:03 Sent To  
Notes
2018-12-17 11:39:29PERMIT # 18110465
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 APPROVED WITH COMMENTS:
  
 1) PER NFPA 101 - 9.4.3 FIRE FIGHTER?S EMERGENCY
 OPERATIONS.
 9.4.3.1 ALL NEW ELEVATORS SHALL CONFORM TO THE FIRE
 FIGHTER?S EMERGENCY OPERATIONS REQUIREMENTS OF ASME
 A17.1/CSA B44, SAFETY CODE FOR ELEVATORS.
  
 FBC SECTION 3003.2 FIRE-FIGHTERS? EMERGENCY OPERATION.
 ELEVATORS SHALL BE PROVIDED WITH PHASE I EMERGENCY
 RECALL OPERATION AND PHASE II EMERGENCY IN-CAR
 OPERATION IN ACCORDANCE WITH ASME A17.1/CSA B44.
  
 2) EVERY ASSEMBLY OCCUPANCY ROOM NOT HAVING FIXED SEATS
 SHALL HAVE THE OCCUPANT LOAD OF THE ROOM POSTED IN A
 CONSPICUOUS PLACE NEAR THE MAIN EXIT FROM THE ROOM.
 SIGNS SHALL BE DURABLE AND INDICATE THE NUMBER OF
 OCCUPANTS PERMITTED FOR EACH ROOM.
  
 3) SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE
 INSTALLATION OR MODIFICATION OF THE FIRE SPRINKLER
 SYSTEM AND/OR FIRE ALARM SYSTEM.
  
  
  
 SUE ELLEN CALDERON
 ASSISTANT FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2019-03-08 Cont ID  
Sent By fmittner Date 2019-03-08 Time 15:40 Rev Time 0.00
Received By fmittner Date 2019-03-08 Time 15:40 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2018-12-20 Cont ID  
Sent By fmittner Date 2018-12-20 Time 16:47 Rev Time 0.00
Received By fmittner Date 2018-12-20 Time 16:47 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-04-02 Cont ID  
Sent By lmarchan Date 2019-04-02 Time 09:30 Rev Time 0.00
Received By lmarchan Date 2019-02-21 Time 15:10 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-01-22 Cont ID  
Sent By gjohnson Date 2019-01-22 Time 10:00 Rev Time 0.00
Received By gjohnson Date 2018-12-10 Time 07:59 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2019-01-18 Cont ID  
Sent By dbattles Date 2019-01-18 Time 11:30 Rev Time 0.00
Received By dbattles Date 2019-01-18 Time 11:30 Sent To  
Notes
2019-01-18 11:31:25NO CHANGE IN OCCUPANCY AND NO CHANGE IN SQ. FOOTAGE.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2019-03-26 Cont ID  
Sent By ccole Date 2019-03-26 Time 16:43 Rev Time 0.00
Received By ccole Date 2019-03-26 Time 16:26 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2019-01-11 Cont ID  
Sent By ccole Date 2019-01-11 Time 16:26 Rev Time 0.00
Received By ccole Date 2019-01-11 Time 16:21 Sent To  
Notes
2019-01-11 16:35:37 
 1ST REVIEW FBC-2017 MECHANICAL
 PERMIT
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) REFER TO SECTION 3005.2 FBC B AND SHOW COMPLIANCE
 FOR REQUIRED VENTILATION IN THE ELEVATOR MACHINE ROOM.
  
 3005.2 VENTING. ELEVATOR MACHINE ROOMS, MACHINERY
 SPACES THAT CONTAIN THE DRIVING MACHINE, AND CONTROL
 ROOMS OR SPACES THAT CONTAIN THE OPERATION OR MOTION
 CONTROLLER FOR ELEVATOR OPERATION SHALL BE PROVIDED
 WITH AN INDEPENDENT VENTILATION OR AIR-CONDITIONING
 SYSTEM TO PROTECT AGAINST THE OVERHEATING OF THE
 ELECTRICAL EQUIPMENT. THE SYSTEM SHALL BE CAPABLE OF
 MAINTAINING TEMPERATURES WITHIN THE RANGE ESTABLISHED
 FOR THE ELEVATOR EQUIPMENT.
  
 2) THE ELEVATOR SHALL BE EQUIPPED WITH AN EXHAUST
 SYSTEM SIZED TO PROVIDE 1.0 CFMS OF EXHAUST PER SF.-
 TABLE 403.3.1.1 FBC M.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status N Date 2019-04-02 Cont ID  
Sent By gjohnson Date 2019-04-02 Time 09:14 Rev Time 0.00
Received By gjohnson Date 2019-04-02 Time 09:14 Sent To  
Notes
2019-04-02 09:19:09NO PLUMBING!!! INCLUDED ON PLAN.
 PLANS AND PERMIT REQUIRED FOR ANY PLUMBING WORK.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status N Date 2019-01-22 Cont ID  
Sent By gjohnson Date 2019-01-22 Time 09:57 Rev Time 0.00
Received By gjohnson Date 2019-01-22 Time 08:43 Sent To  
Notes
2019-01-22 09:59:28NO PLUMBING!!! INCLUDED ON PLAN.
 PLANS AND PERMIT REQUIRED FOR ANY PLUMBING WORK.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  

Review Stop P-IRRIGATE IRRIGATION REVIEW
Rev No 2 Status P Date 2019-04-02 Cont ID  
Sent By gjohnson Date 2019-04-02 Time 09:14 Rev Time 0.00
Received By gjohnson Date 2019-04-02 Time 09:14 Sent To  
Notes
***NONE***

Review Stop P-IRRIGATE IRRIGATION REVIEW
Rev No 1 Status P Date 2019-01-22 Cont ID  
Sent By gjohnson Date 2019-01-22 Time 09:59 Rev Time 0.00
Received By gjohnson Date 2019-01-22 Time 09:59 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2019-02-26 Cont ID  
Sent By dbattles Date 2019-02-26 Time 13:51 Rev Time 0.00
Received By dbattles Date 2019-02-26 Time 13:51 Sent To  
Notes
2019-02-26 13:53:06ALL SHEETS FOR 2ND REVIEW ARE OK
 IF ADDITIONAL SHEETS ARE NEEDED THEY WILL NEED TO BE
 DIGITALLY SIGNED.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2019-01-18 Cont ID  
Sent By dbattles Date 2019-01-18 Time 11:32 Rev Time 0.00
Received By dbattles Date 2019-01-18 Time 11:32 Sent To  
Notes
2019-01-18 11:32:30ALL SHEETS FOR FIRST REVIEW - OK.
 ANY NEW SHEETS SUBMITTED FOR SECOND REVIEW WILL NEED TO
 BE REVIEWED FOR DIGTAL SIGNATURE.

Review Stop Z ZONING
Rev No 2 Status P Date 2019-03-08 Cont ID  
Sent By fmittner Date 2019-03-15 Time 15:40 Rev Time 0.00
Received By aaponte Date 2019-03-08 Time 15:40 Sent To  
Notes
2019-03-15 12:06:44PROVISO: 1. LANDSCAPE ISLANDS SHALL BE PROTECTED FROM
 VEHICLE INTRUSION WITH A CURB.
  

Review Stop Z ZONING
Rev No 1 Status F Date 2019-01-09 Cont ID  
Sent By aaponte Date 2019-01-09 Time 10:14 Rev Time 0.00
Received By aaponte Date 2019-01-09 Time 10:13 Sent To  
Notes
2019-01-09 10:38:591. PARKING LOT ACCESS SHALL BE RELOCATED TO MATCH DRIVE
 AISLE. CURB CUT RELOCATION WILL ALLOW ADDITIONAL
 PARKING SPACES ON SOUTH SIDE OF LOT. LANDSCAPE BUFFER
 (TERMINAL ISLAND) WILL BE REQUIRED.
 2. DUMPSTER IS REQUIRED TO PROVIDE BUFFER ON ALL SIDES
 (EXCEPT GATE). IF TEH WEST TERMINAL ISLAND IS LARGER
 THAN THE MINIMUM 8 FEET REQUIRED, ADDITIONAL WIDTH CAN
 BE LOCATED ON THE DUMPSTER SIDE.
 3. A TERMINAL ISLAND SHALL BE PROVIDED ADJACENT TO THE
 HANDICAP SPACE. GAP TO ACCESS THE RAMP IS ALLOWED.
 4. PARKING DETAIL SHALL MEET CITY STANDARDS (SEC 94-485
 - STALL PAINTING DETAIL).
 5. CONSIDERING THE RAMP ACCESS IS LOCATED ON THE
 ADJACENT PROPERTY THE TWO PROPERTIES SHALL BE UNIFIED.
 FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA
 APONTE AT 561-822-1439.