Plan Review Details - Permit 18110389
Plan Review Stops For Permit 18110389
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-12-27 Cont ID  
Sent By pvalenti Date 2018-12-27 Time 16:51 Rev Time 0.00
Received By pvalenti Date 2018-12-27 Time 16:51 Sent To M
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-12-13 Cont ID  
Sent By pvalenti Date 2018-12-13 Time 09:19 Rev Time 0.00
Received By pvalenti Date 2018-12-13 Time 09:19 Sent To  
Notes
2018-12-13 10:05:07****CORRECTIONS****
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 FBC 107. PLEASE PROVIDE MORE INFORMATION :
  
 1. THE SUBMITTED PLANS SHOW AN INTERIOR ROOM LABELED
 "GARAGE" IN ADDITION TO THE EXISTING GARAGE AT THE
 FRONT OF THE HOUSE. PLEASE ADDRESS THIS DISCREPANCY.
  
  
 2. A SHUTTER PRODUCT APPROVAL WAS SUBMITTED WITHOUT ANY
 OTHER REQUIRED INFORMATION:
  
 A. PROVIDE A SKETCH/LAYOUT SHEET SHOWING THE LOCATION
 OF ALL SHUTTERS TO BE INSTALLED.THIS LAYOUT SHEET
 SHOULD INDICATE WINDOW/DOOR OPENINGS NUMBERED TO MATCH
 WITH THE SCHEDULE FOR INSTALLATION OF OPENING
 PROTECTIVE DEVICES.
  
  
 B. FBC R 301, COMPLETE THE "SCHEDULE FOR INSTALLATION
 OF OPENING PROTECTIVE DEVICES" OR PROVIDE ALL
 INFORMATION REQUIRED IN ANOTHER FORMAT (SUCH AS EXCEL
 SPREADSHEET):
  
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS?PAGE=2
  
 C. WHEN COMPLETING THE INSTALLATION SCHEDULE FACTORS
 APPLY DEPENDING ON SUBSTRATE, EDGE DISTANCE AND
 FASTENER. FOR FASTENER, IF USING TAPCON, BE SPECIFIC AS
 TO WHICH TAPCON.
  
  
 D. REVISE PLAN TO SHOW MEANS OF ESCAPE REQUIRED BY FBC
 R 310.4; INCLUDE ROOM DESIGNATION.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2018-11-28 Cont ID  
Sent By jleahy Date 2018-11-28 Time 18:25 Rev Time 0.00
Received By jleahy Date 2018-11-28 Time 18:25 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-01-02 Cont ID  
Sent By cmontell Date 2019-01-02 Time 13:09 Rev Time 0.00
Received By cmontell Date 2019-01-02 Time 13:09 Sent To  
Notes
2018-12-27 12:47:03RESUB ROUTED TO PVALENTI

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-12-26 Cont ID  
Sent By cthroop Date 2018-12-26 Time 15:07 Rev Time 0.00
Received By cthroop Date 2018-11-09 Time 15:09 Sent To  
Notes
2018-11-13 15:09:17R07

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2019-01-02 Cont ID  
Sent By cmontell Date 2019-01-02 Time 13:08 Rev Time 0.00
Received By cmontell Date 2019-01-02 Time 13:02 Sent To I
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2018-11-16 Cont ID  
Sent By cmontell Date 2018-11-16 Time 10:36 Rev Time 0.00
Received By cmontell Date 2018-11-16 Time 10:09 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2018-12-26 Cont ID  
Sent By cthroop Date 2018-12-26 Time 15:07 Rev Time 0.00
Received By cthroop Date 2018-12-26 Time 12:32 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2018-12-13 Cont ID  
Sent By pvalenti Date 2018-12-13 Time 10:09 Rev Time 0.00
Received By pvalenti Date 2018-12-13 Time 10:09 Sent To  
Notes
***NONE***