Plan Review Stops For Permit 18110341 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2019-02-26 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2019-02-26 |
Time |
07:08 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2019-02-21 |
Time |
17:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2019-01-26 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2019-01-26 |
Time |
11:11 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2019-01-26 |
Time |
11:06 |
Sent To |
|
|
Notes |
2019-01-26 11:52:06 | ****CORRECTIONS**** | | | | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | FBC 107. PLEASE PROVIDE MORE INFORMATION: | | | | 1. PROVIDE THE DESIGNER OF RECORD SIGNATURE AND SEAL ON | | THE SUBMITTED DRAWINGS AS PER FBC 107.1 FLORIDA | | STATUTES SECTIONS 471(PROFESSIONAL ENGINEER) OR | | 481(REGISTERED ARCHITECT). | | | | 2. ACCESSIBILITY: IF CONSTRUCTION TRAILOR IS TO BE USED | | FOR MEETINGS/ASSEMBLY, THE REQUIREMENTS FOR PROVIDING | | ACCESSIBLE ACCESS (INCLUDING PARKING AREAS AND | | ACCESSIBLE ROUTES) ARE REQUIRED. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL COMMENTS MAY | | RESULT IN NEW PLAN REVIEW COMMENTS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2019-01-02 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2019-01-02 |
Time |
17:30 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2019-01-02 |
Time |
17:00 |
Sent To |
|
|
Notes |
2019-01-02 17:30:00 | 2ND REVIEW: FBC 2017 6TH EDITION | | | | | | BUILDING - REVIEW FAILED | | | | PREVIOUS COMMENTS NOTADEQUATELY ANSWERED | | | | FBC CHAPTER 1 SECTION 107 - MINIMUM PLAN REVIEW | | CRITERIA | | | | 1) PROVIDE A SITE PLAN - THE PROVIDED PLAN IS FOR | | PROPERTY AT THE NW INTERSECTION OF MADERIA COURT AND | | PBL BLVD ADDRESSED AS 425 PALM BEACH LAKES BLVD ON THE | | ELECTRICAL SERVICE PLAN BUT NO ADDRESS IS ASSIGNED IN | | THE CITY PERMITTING SOFTWARE . THIS IS NOT CONSISTENT | | WITH THE ADDDRESS ASSIGNED TO THE PERMIT APPLICATION. | | PLEASE CORRECT THE ADDRESS ON THE APPLICATION. OBTAIN | | AN ADDRESS BY CONTACTION MICHAEL ORIO AT 561 494-1171 | | OR [email protected]. THE PLAN INDICATES NO PARKING | | PROVISION, INDICATE REQUIRED PARKING AND ACCESSIBLE | | PARKING IF NEEDED. THERE IS NO PROVISION FOR ACCESS TO | | THE PROPERTY AT THE STREET TO ROAD CONNECTION. YOU MAY | | NEED TO OBTAIN A DRIVEWAY PERMIT TO PROVIDE A PROPER | | CONNECTION.THE PLAN SHOWS A FENCE WHICH REQUIRES A | | SEPARATE PERMIT. | | | | 2) CLARIFY THE INTENDED USE OF THE STRUCTURE AND LENGTH | | OF TIME IT IS TO BE IN PLACE. THIS COMMENT WAS NOT | | ADDRESSED IN THE RESUBMITTAL, | | | | IF THE LENGTH OF TIME EXCEEDS SIX MONTHS AND OR IF THE | | USE IS BEYOND THAT OF CONSTRUCTUION PERSONEL ONLY, | | PROVIDE THE FOLLOWING: | | | | 3) A FOUNDATION AND TIE DOWN PLAN - THIS COMMENT WAS | | NOT ADDRESSED IN THE RESUBMITTAL, PLANS TOO SMALL TO | | READ. | | | | 4) ACCESSIBLE PARKING SPACE -THIS COMMENT WAS NOT | | ADDRESSED IN THE RESUBMITTAL, | | | | 5) ACCESSIBLE ENTRANCE/RAMP OR OTHER MEANS - THIS | | COMMENT WAS NOT ADDRESSED IN THE RESUBMITTAL, | | | | NEW COMMENT: | | 6) THE WILLIAMS SCOTSMAN MODULAR PLAN SUBMITTED IS TOO | | SMALL TO READ. IS THIS A PLAN THAT CAN BE FOUND ON THE | | THE FLORIDA DBPR BCIS WEBSITE AS AN APPROVED MODULAR | | BUILDING? IF SO, PROVIDE THE PLAN NUMBER AND IN ANY | | CASE A PLAN LARGE ENOUGH TO READ. IF NOT, THE | | PROFESSIONAL INSIGNIA ON THE REDUCED PLAN IS NOT | | ACCEPTABLE PER CHAPTER 471, FLORIDA STATUTES& 61G15 | | FLORIDA ADMINISTRATIVE CODE OR CHAPTER 481, FLORIDA | | STATUTES& 61G1 FLORIDA ADMINISTRATIVE CODE. | | | | STEVEN KENNEDY, CBO | | ASSISTANT BUILDING OFFICIAL | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2018-12-04 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2018-12-04 |
Time |
14:11 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2018-12-04 |
Time |
14:11 |
Sent To |
|
|
Notes |
2018-12-04 14:12:43 | 1ST REVIEW: FBC 2017 6TH EDITION | | 1ST REVIEW FBC 2017 EXISTING BUILDING | | | | BUILDING - DENIED | | | | PROVIDE THE FOLLOWING | | 1) SITE PLAN | | 2) CLARIFY THE INTENDED USE OF THE STRUCTURE AND LENGTH | | OF TIME IT IS TO BE IN PLACE. | | | | IF THE LENGTH OF TIME EXCEEDS SIX MONTHS AND OR IF THE | | USE IS BEYOND THAT OF CONSTRUCTUION PERSONEL ONLY, | | PROVIDE THE FOLLOWING: | | | | 3) A FOUNDATION AND TIE DOWN PLAN | | 4) ACCESSIBLE PARKING SPACE | | 5) ACCESSIBLE ENTRANCE/RAMP OR OTHER MEANS | | | | STEVEN KENNEDY, CBO | | ASSISTANT BUILDING OFFICIAL | | (561) 805-6710 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
N |
Date |
2019-01-24 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-01-24 |
Time |
07:03 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-01-24 |
Time |
07:03 |
Sent To |
|
|
Notes |
2019-01-24 07:03:37 | SEE PERMIT 18120882 FOR ELECTRICAL. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2018-12-24 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-12-24 |
Time |
10:39 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-12-24 |
Time |
10:39 |
Sent To |
|
|
Notes |
2018-12-24 10:39:02 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | 1. PER THE WPB AMENDMENTS TO THE FBC, PLAN IS REQUIRED | | TO BE SIGNED BY PERSON RESPONSIBLE FOR THE DESIGN. | | PROVIDE CORRECTION. FS 471/481; WPB FBC 107.1, 107.2.1, | | 107.3.5.1.2 (PLAN AND RISER NOT SIGNED.) | | 2. CORRECTED. | | | | NEW COMMENTS: | | | | 3. PLAN SHOWS 4/0 ALUMINUM FEEDING THE TWO 200 AMP | | DISCONNECTS. THIS WIRE IS NOT RATED FOR 200 AMPS AND A | | LOAD CALCULATION WAS NOT PROVIDED STATING THAT THIS | | WIRE WILL HANDLE THE LOAD. EITHER CORRECT WIRE SIZE, OR | | PROVIDE LOAD CALCULATION SHOWING THIS WIRE SIZE CAN | | HANDLE THE LOAD. NEC 220, 240.4, 310.15(B)(16) | | 4. PLAN SHOWS 250 KCMIL TRIPLEX FEEDING THE TRAILERS. | | THESE FEEDERS ARE REQUIRED TO HAVE AN EQUIPMENT | | GROUNDING CONDUCTOR. PROVIDE CORRECTION. NEC 250.110, | | 250.122 | | 5. PLAN SHOWS A SINGLE PHASE SERVICE, BUT THE TRAILER | | PANELS STATE THERE IS 208 VOLTS. IS THIS SERVICE SINGLE | | PHASE 240 VOLT, OR THREE PHASE 208 VOLT? PROVIDE | | CLARIFICATION AND/OR CORRECTIONS. WPB FBC 107.2.1 | | 6. PROVIDE SERVICE AREA RECEPTACLE. NEC 210.64 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2018-11-30 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-11-30 |
Time |
13:55 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-11-30 |
Time |
13:23 |
Sent To |
|
|
Notes |
2018-11-30 13:55:45 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PER THE WPB AMENDMENTS TO THE FBC, PLAN IS REQUIRED | | TO BE SIGNED BY PERSON RESPONSIBLE FOR THE DESIGN. | | PROVIDE CORRECTION. FS 471/481; WPB FBC 107.1, 107.2.1, | | 107.3.5.1.2 | | 2. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | 250.50, 250.94, 408.30 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
4 |
Status |
P |
Date |
2019-02-06 |
|
|
Cont ID |
|
Sent By |
scaldero |
Date |
2019-02-06 |
Time |
10:15 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2019-02-06 |
Time |
10:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2019-01-23 |
|
|
Cont ID |
|
Sent By |
scaldero |
Date |
2019-01-23 |
Time |
08:35 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2019-01-23 |
Time |
08:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2018-12-19 |
|
|
Cont ID |
|
Sent By |
scaldero |
Date |
2018-12-19 |
Time |
11:39 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2018-12-19 |
Time |
11:35 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2018-11-15 |
|
|
Cont ID |
|
Sent By |
scaldero |
Date |
2018-11-15 |
Time |
13:02 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2018-11-15 |
Time |
12:58 |
Sent To |
|
|
Notes |
2018-11-15 13:02:43 | PERMIT # 18110341 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | FAILED COMMENT: | | | | 1) PLEASE PROVIDE A SITE PLAN THAT INDICATES THE | | LOCATION OF WHERE THIS TRAILER WILL BE PLACED. PLEASE | | BE SURE TO INCLUDE THE LOCATIONS/DIMENSIONS OF OTHER | | STRUCTURES ON THE SITE. | | | | 2) TEMPORARY CONSTRUCTION TRAILERS OR MODULAR BUILDINGS | | WILL REQUIRE A PERMIT AND COMPLIANCE WITH THE | | FOLLOWING: | | PER NFPA 241- STANDARD FOR SAFEGUARDING CONSTRUCTION, | | ALTERATION, AND DEMOLITION OPERATIONS, SECTION 4.2: | | TEMPORARY OFFICES, TRAILERS, AND OTHER FACILITIES OF | | COMBUSTIBLE CONSTRUCTION OR HOUSING COMBUSTIBLE | | CONTENTS SHALL BE SEPARATED FROM ADJACENT BUILDINGS, | | TRAILERS OR STRUCTURES IN ACCORDANCE WITH TABLE 4.2.1. | | PER TABLE 4.2.1: | | 1) 20 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | ADJACENT STRUCTURES BY AT LEAST 30 FEET | | 2) 30 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | ADJACENT STRUCTURES BY AT LEAST 35 FEET | | 3) 40 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | ADJACENT STRUCTURES BY AT LEAST 40 FEET | | 4) 50 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | ADJACENT STRUCTURES BY AT LEAST 45 FEET | | 5) 60 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | ADJACENT STRUCTURES BY AT LEAST 50 FEET | | 6) GREATER THAN 60 FEET EXPOSED LENGTH SHALL BE | | SEPARATED FROM ADJACENT STRUCTURES BY AT LEAST 60 FEET | | **A 75 PERCENT REDUCTION IN SEPARATION DISTANCES SHALL | | BE PERMITTED TO BE APPLIED, PROVIDED AUTOMATIC | | SPRINKLER PROTECTION IS USED IN THE EXPOSING STRUCTURE. | | | | | | SUE ELLEN CALDERON | | ASSISTANT FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2019-03-01 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2019-03-01 |
Time |
13:33 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2019-02-04 |
Time |
14:49 |
Sent To |
|
|
Notes |
2019-02-28 15:38:55 | ROUTED FROM ZONING TO PERMIT LIBRARIAN 2/28/2019 EL | 2019-02-05 14:50:07 | B28 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2019-01-31 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2019-01-31 |
Time |
08:48 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2019-01-31 |
Time |
08:48 |
Sent To |
|
|
Notes |
2019-01-29 15:24:08 | ROUTED FROM ZONING TO PERMIT LIBRARIAN 1/29/19 EL | 2019-01-17 15:49:37 | B03 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-01-02 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2019-01-02 |
Time |
17:30 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2018-12-13 |
Time |
12:58 |
Sent To |
|
|
Notes |
2018-12-20 15:28:05 | ROUTED FROM ZONING TO PERMIT LIBRARIAN 12/20/18 | 2018-12-14 12:59:55 | B04 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-12-04 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2018-12-04 |
Time |
15:52 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2018-12-04 |
Time |
15:52 |
Sent To |
|
|
Notes |
2018-11-20 09:45:42 | ROUTED FROM ZONING TO PERMIT LIBRARIAN 11/20/18 | 2018-11-13 13:19:56 | B07 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2018-11-30 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-11-30 |
Time |
08:57 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-11-30 |
Time |
08:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
N |
Date |
2019-02-21 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2019-02-21 |
Time |
13:41 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2019-02-21 |
Time |
13:40 |
Sent To |
|
|
Notes |
2019-03-01 13:33:35 | 3/1 TEMPORARY CONSTRUCTION TRAILER WHICH APPEARS TO BE | | A STATE APPROVED MODULAR BUT IS EXEMPT FROM FBC. ADDED | | AN "N" AS NO FBC REVIEW IS REQUIRED. | | S. HILL | 2019-02-21 13:41:10 | MODULAR/STATE STAMP REQUIRED | | SAMANTHA HILL TO HANDLE |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2019-01-31 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2019-01-31 |
Time |
08:48 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2019-01-31 |
Time |
08:45 |
Sent To |
|
|
Notes |
2019-01-31 08:45:43 | 1ST REVIEW | | COMMENTS: APPROVED | | | | PROVISO | | 1. ALL WORK PER CITY CODES SUBJECT TO FIELD INSPECTOR'S | | APPROVAL | | 2. SEWER AND WATER CONNECTION FOR TEMPORARY | | CONSTRUCTION OFFICE MODULAR STRUCTURE | | | | JERALD SMITH | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | EMAIL [email protected] | | PHONE 561-805-6715 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2018-12-04 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2018-12-04 |
Time |
15:51 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2018-12-04 |
Time |
15:50 |
Sent To |
|
|
Notes |
2018-12-04 15:50:48 | 1ST REVIEW | | COMMENTS: APPROVED | | | | PROVISO | | 1. ALL WORK PER CITY CODES SUBJECT TO FIELD INSPECTOR'S | | APPROVAL | | 2. SEWER AND WATER CONNECTION FOR TEMPORARY | | CONSTRUCTION OFFICE MODULAR STRUCTURE | | | | JERALD SMITH | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | EMAIL [email protected] | | PHONE 561-805-6715 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2019-02-28 |
|
|
Cont ID |
|
Sent By |
elevesqu |
Date |
2019-02-28 |
Time |
15:38 |
Rev Time |
0.00 |
Received By |
elevesqu |
Date |
2019-02-28 |
Time |
15:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2019-01-29 |
|
|
Cont ID |
|
Sent By |
elevesqu |
Date |
2019-01-29 |
Time |
15:22 |
Rev Time |
0.00 |
Received By |
elevesqu |
Date |
2019-01-29 |
Time |
15:22 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2018-12-20 |
|
|
Cont ID |
|
Sent By |
elevesqu |
Date |
2018-12-20 |
Time |
15:27 |
Rev Time |
0.00 |
Received By |
elevesqu |
Date |
2018-12-20 |
Time |
15:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2018-11-20 |
|
|
Cont ID |
|
Sent By |
elevesqu |
Date |
2018-11-20 |
Time |
09:43 |
Rev Time |
0.00 |
Received By |
elevesqu |
Date |
2018-11-20 |
Time |
09:43 |
Sent To |
|
|
Notes |
2018-11-20 09:44:58 | PLEASE PROVIDE SITE PLAN SHOWING LOCATION OF PROPOSED | | TEMPORARY SALES TRAILER. IF OFFSITE PLEASE SHOW | | DISTANCE FROM 300 PBL CONSTRUCTION SITE. | | | | PLEASE INCLUDE DETAIL INCLUDING SETBACKS, SHOW PROPERTY | | LINES, INDICATE ANY PROPOSED SCREENING, ETC. | | | | LIZ LEVESQUE, URBAN DESIGN PLANNER | | 561 822 1426 | | [email protected] |
|
|