Plan Review Stops For Permit 18110168 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2019-01-04 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2019-01-04 |
Time |
07:16 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2019-01-04 |
Time |
07:16 |
Sent To |
|
|
Notes |
2019-01-04 07:21:35 | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | APPROVED WITH PROVISO: | | | | AT TIME OF INSPECTION, PROVIDE ROOFING PRODUCT | | APPROVALS INCLUDING: ROOF TILE, UNDERLAYMENTS, AND FLAT | | ROOF TORCH DOWN MATERIALS ON SITE FOR INSPECTOR. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2018-12-06 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2018-12-06 |
Time |
10:02 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2018-12-06 |
Time |
10:02 |
Sent To |
|
|
Notes |
2018-12-06 10:02:23 | | | ****CORRECTIONS**** | | | | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1.PLEASE PROVIDE PRODUCT APPROVALS FOR ROOF TILES AND | | UNDERLAYMENT/BASE MATERIAL. FBC 107.1 | | 2.PLEASE PROVIDE MANUFACTURER?S INSTRUCTIONS FOR THE | | VENTED HOOD AND GAS GRILL SHOWN IN SHEET 1. FBC 107.1 | | 3.PROVIDE LOCATION WITH ATTACHMENTS DETAILS AND EXHAUST | | LOCATION(INCLUDING TERMINATION) FOR THE VENTED HOOD. | | FBCR 1307.1 AND 1307.2 | | 4.THE STUCCO DETAIL NEEDS ADDITIONAL LAYER OF WATER | | BARRIER. | | R703.7.3 WATER-RESISTIVE BARRIERS. | | WATER-RESISTIVE BARRIERS SHALL BE INSTALLED AS REQUIRED | | IN SECTION R703.2 AND, WHERE APPLIED OVER WOOD-BASED | | SHEATHING, SHALL INCLUDE A WATER-RESISTIVE | | VAPOR-PERMEABLE BARRIER WITH A PERFORMANCE AT LEAST | | EQUIVALENT TO TWO LAYERS OF GRADE D PAPER. THE | | INDIVIDUAL LAYERS SHALL BE INSTALLED INDEPENDENTLY SUCH | | THAT EACH LAYER PROVIDES A SEPARATE CONTINUOUS PLANE | | AND ANY FLASHING (INSTALLED IN ACCORDANCE WITH SECTION | | R703.4) INTENDED TO DRAIN TO THE WATER-RESISTIVE | | BARRIER IS DIRECTED BETWEEN THE LAYERS. | | EXCEPTION: WHERE THE WATER-RESISTIVE BARRIER THAT IS | | APPLIED OVER WOOD-BASED SHEATHING HAS A WATER | | RESISTANCE EQUAL TO OR GREATER THAN THAT OF 60-MINUTE | | GRADE D PAPER AND IS SEPARATED FROM THE STUCCO BY AN | | INTERVENING, SUBSTANTIALLY NONWATER-ABSORBING LAYER OR | | DESIGNED DRAINAGE SPACE. | | 5.PLEASE PROVIDE DECK RAFTERS SIZE. FBC 107.2 | | 6.PLEASE PROVIDE THE SPACING FOR THE #5 FILL CELLS | | REBAR. FBC 107.2.1 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2018-12-23 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-12-23 |
Time |
13:13 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-12-23 |
Time |
13:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2018-12-04 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2018-12-04 |
Time |
07:03 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2018-12-04 |
Time |
06:40 |
Sent To |
B |
|
Notes |
2018-12-04 06:48:19 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PROVIDE UL/NRTL LISTING FOR HOOD FAN AND | | INSTALLATION INSTRUCTIONS FOR PRODUCT APPROVAL. | | 90.7,110.2,110.3B NEC | | | | 2. LIGHTING OUTLET CONTROLLED BY WALL SWITCH REQUIRED | | IN NEW STORAGE AREA. 210.70A2 NEC | | | | | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | CODES IN EFFECT: | | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2017 6TH ED. | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | FRANK GIAQUINTO III | | ELECTRICAL INSPECTOR | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | [email protected] | | CELL: 561-657-1653 | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
P |
Date |
2018-12-03 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2018-12-03 |
Time |
06:40 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2018-12-03 |
Time |
06:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-01-04 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2019-01-04 |
Time |
07:21 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2018-12-18 |
Time |
14:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-12-06 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2018-12-06 |
Time |
10:02 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2018-11-05 |
Time |
14:46 |
Sent To |
I |
|
Notes |
2018-11-06 14:46:56 | ROUTED TO ZONING INBOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2018-12-31 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2018-12-31 |
Time |
14:57 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2018-12-31 |
Time |
14:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2018-12-03 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2018-12-03 |
Time |
09:30 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2018-12-03 |
Time |
09:30 |
Sent To |
E |
|
Notes |
2018-12-03 09:36:22 | PLAN DENIED | | PROVIDE MANUFACTURERS INSTALLATION INSTRUCTIONS FOR | | GAS GRILL AND HOOD PER SECTION 107 | | FBC 2017 | | | | PLAN REVIEW BY HAROLD MOSER | | [email protected] | | OFFICE 561-805-6732 | | FAX 561-805-6676 |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
N |
Date |
2018-12-18 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2018-12-18 |
Time |
14:17 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2018-12-18 |
Time |
14:17 |
Sent To |
|
|
Notes |
2018-12-18 14:18:57 | ROOFING WILL BE A SEPARATE APPLICATION BY ROOFING | | SUB-CONTRACTOR. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2019-01-03 |
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2019-01-03 |
Time |
14:15 |
Rev Time |
0.00 |
Received By |
mcruz |
Date |
2019-01-03 |
Time |
14:15 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2018-11-13 |
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2018-11-13 |
Time |
09:54 |
Rev Time |
0.00 |
Received By |
mcruz |
Date |
2018-11-13 |
Time |
09:05 |
Sent To |
G |
|
Notes |
2018-11-13 09:54:52 | ZONING REVIEW FAILED, DUE TO THE FOLLOWING: | | | | 1) PROVIDE 2 COPIES OF A SURVEY. | | 2) INDICATE LOCATION OF THE PROPOSED SHED AND GRILL ON | | SURVEY. PURSUANT TO 94-304(B)(2), THE FOLLOWING ARE THE | | SETBACKS FOR ACCESSORY STRUCTURES: | | FRONT: 25 FEET. | | SIDE: FIVE FEET FROM THE LOT LINES. | | REAR: FIVE FEET MINIMUM | | 3) INDICATE ON SURVEY THE LOCATION OF THE PROPOSED | | STAIRS. PURSUANT TO 94-305(B)(7), STEPS, OPEN UNCOVERED | | PORCHES OR STOOPS, AND OPEN TERRACES WHICH ARE THREE | | FEET OR LESS ABOVE GRADE MAY ENCROACH INTO ANY REQUIRED | | SETBACK AREA TO A POINT NOT CLOSER THAN TWO FEET TO THE | | PROPERTY LINE. ANY GRADE DIFFERENTIAL BETWEEN THE | | ENCROACHING STEP, PORCH, STOOP, OR TERRACE AND ADJACENT | | PROPERTY SHALL BE STRUCTURALLY RETAINED AND POSITIVELY | | DRAINED IN A MANNER THAT WILL PREVENT ANY DRAINAGE | | DISCHARGE TO ANY PROPERTY CONTIGUOUS TO THE SIDE OR | | REAR PROPERTY LINES. | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | PLANNING DEPARTMENT WEBSITE AT | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | CONTACT ME. | | | | MAGGIE CRUZ | | ASSOCIATE PLANNER | | PLANNING AND ZONING DEPARTMENT | | TEL: 561-822-1442 | | E-MAIL: [email protected] |
|
|