Plan Review Details - Permit 18110168
Plan Review Stops For Permit 18110168
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-01-04 Cont ID  
Sent By pvalenti Date 2019-01-04 Time 07:16 Rev Time 0.00
Received By pvalenti Date 2019-01-04 Time 07:16 Sent To  
Notes
2019-01-04 07:21:35PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 APPROVED WITH PROVISO:
  
 AT TIME OF INSPECTION, PROVIDE ROOFING PRODUCT
 APPROVALS INCLUDING: ROOF TILE, UNDERLAYMENTS, AND FLAT
 ROOF TORCH DOWN MATERIALS ON SITE FOR INSPECTOR.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-12-06 Cont ID  
Sent By pvalenti Date 2018-12-06 Time 10:02 Rev Time 0.00
Received By pvalenti Date 2018-12-06 Time 10:02 Sent To  
Notes
2018-12-06 10:02:23 
 ****CORRECTIONS****
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1.PLEASE PROVIDE PRODUCT APPROVALS FOR ROOF TILES AND
 UNDERLAYMENT/BASE MATERIAL. FBC 107.1
 2.PLEASE PROVIDE MANUFACTURER?S INSTRUCTIONS FOR THE
 VENTED HOOD AND GAS GRILL SHOWN IN SHEET 1. FBC 107.1
 3.PROVIDE LOCATION WITH ATTACHMENTS DETAILS AND EXHAUST
 LOCATION(INCLUDING TERMINATION) FOR THE VENTED HOOD.
 FBCR 1307.1 AND 1307.2
 4.THE STUCCO DETAIL NEEDS ADDITIONAL LAYER OF WATER
 BARRIER.
 R703.7.3 WATER-RESISTIVE BARRIERS.
 WATER-RESISTIVE BARRIERS SHALL BE INSTALLED AS REQUIRED
 IN SECTION R703.2 AND, WHERE APPLIED OVER WOOD-BASED
 SHEATHING, SHALL INCLUDE A WATER-RESISTIVE
 VAPOR-PERMEABLE BARRIER WITH A PERFORMANCE AT LEAST
 EQUIVALENT TO TWO LAYERS OF GRADE D PAPER. THE
 INDIVIDUAL LAYERS SHALL BE INSTALLED INDEPENDENTLY SUCH
 THAT EACH LAYER PROVIDES A SEPARATE CONTINUOUS PLANE
 AND ANY FLASHING (INSTALLED IN ACCORDANCE WITH SECTION
 R703.4) INTENDED TO DRAIN TO THE WATER-RESISTIVE
 BARRIER IS DIRECTED BETWEEN THE LAYERS.
 EXCEPTION: WHERE THE WATER-RESISTIVE BARRIER THAT IS
 APPLIED OVER WOOD-BASED SHEATHING HAS A WATER
 RESISTANCE EQUAL TO OR GREATER THAN THAT OF 60-MINUTE
 GRADE D PAPER AND IS SEPARATED FROM THE STUCCO BY AN
 INTERVENING, SUBSTANTIALLY NONWATER-ABSORBING LAYER OR
 DESIGNED DRAINAGE SPACE.
 5.PLEASE PROVIDE DECK RAFTERS SIZE. FBC 107.2
 6.PLEASE PROVIDE THE SPACING FOR THE #5 FILL CELLS
 REBAR. FBC 107.2.1
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2018-12-23 Cont ID  
Sent By jpearson Date 2018-12-23 Time 13:13 Rev Time 0.00
Received By jpearson Date 2018-12-23 Time 13:13 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-12-04 Cont ID  
Sent By fgiaquin Date 2018-12-04 Time 07:03 Rev Time 0.00
Received By fgiaquin Date 2018-12-04 Time 06:40 Sent To B
Notes
2018-12-04 06:48:19ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE UL/NRTL LISTING FOR HOOD FAN AND
 INSTALLATION INSTRUCTIONS FOR PRODUCT APPROVAL.
 90.7,110.2,110.3B NEC
  
 2. LIGHTING OUTLET CONTROLLED BY WALL SWITCH REQUIRED
 IN NEW STORAGE AREA. 210.70A2 NEC
  
  
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 CODES IN EFFECT:
  
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2017 6TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 FRANK GIAQUINTO III
 ELECTRICAL INSPECTOR
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 [email protected]
 CELL: 561-657-1653
  

Review Stop G GAS REVIEW
Rev No 1 Status P Date 2018-12-03 Cont ID  
Sent By tklarge Date 2018-12-03 Time 06:40 Rev Time 0.00
Received By tklarge Date 2018-12-03 Time 06:01 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-01-04 Cont ID  
Sent By pvalenti Date 2019-01-04 Time 07:21 Rev Time 0.00
Received By pvalenti Date 2018-12-18 Time 14:49 Sent To  
Notes
2018-12-19 14:49:49R13

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-12-06 Cont ID  
Sent By pvalenti Date 2018-12-06 Time 10:02 Rev Time 0.00
Received By pvalenti Date 2018-11-05 Time 14:46 Sent To I
Notes
2018-11-06 14:46:56ROUTED TO ZONING INBOX

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2018-12-31 Cont ID  
Sent By hmoser Date 2018-12-31 Time 14:57 Rev Time 0.00
Received By hmoser Date 2018-12-31 Time 14:46 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2018-12-03 Cont ID  
Sent By hmoser Date 2018-12-03 Time 09:30 Rev Time 0.00
Received By hmoser Date 2018-12-03 Time 09:30 Sent To E
Notes
2018-12-03 09:36:22PLAN DENIED
 PROVIDE MANUFACTURERS INSTALLATION INSTRUCTIONS FOR
 GAS GRILL AND HOOD PER SECTION 107
 FBC 2017
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2018-12-18 Cont ID  
Sent By skennedy Date 2018-12-18 Time 14:17 Rev Time 0.00
Received By skennedy Date 2018-12-18 Time 14:17 Sent To  
Notes
2018-12-18 14:18:57ROOFING WILL BE A SEPARATE APPLICATION BY ROOFING
 SUB-CONTRACTOR.

Review Stop Z ZONING
Rev No 2 Status P Date 2019-01-03 Cont ID  
Sent By mcruz Date 2019-01-03 Time 14:15 Rev Time 0.00
Received By mcruz Date 2019-01-03 Time 14:15 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2018-11-13 Cont ID  
Sent By mcruz Date 2018-11-13 Time 09:54 Rev Time 0.00
Received By mcruz Date 2018-11-13 Time 09:05 Sent To G
Notes
2018-11-13 09:54:52ZONING REVIEW FAILED, DUE TO THE FOLLOWING:
  
 1) PROVIDE 2 COPIES OF A SURVEY.
 2) INDICATE LOCATION OF THE PROPOSED SHED AND GRILL ON
 SURVEY. PURSUANT TO 94-304(B)(2), THE FOLLOWING ARE THE
 SETBACKS FOR ACCESSORY STRUCTURES:
 FRONT: 25 FEET.
 SIDE: FIVE FEET FROM THE LOT LINES.
 REAR: FIVE FEET MINIMUM
 3) INDICATE ON SURVEY THE LOCATION OF THE PROPOSED
 STAIRS. PURSUANT TO 94-305(B)(7), STEPS, OPEN UNCOVERED
 PORCHES OR STOOPS, AND OPEN TERRACES WHICH ARE THREE
 FEET OR LESS ABOVE GRADE MAY ENCROACH INTO ANY REQUIRED
 SETBACK AREA TO A POINT NOT CLOSER THAN TWO FEET TO THE
 PROPERTY LINE. ANY GRADE DIFFERENTIAL BETWEEN THE
 ENCROACHING STEP, PORCH, STOOP, OR TERRACE AND ADJACENT
 PROPERTY SHALL BE STRUCTURALLY RETAINED AND POSITIVELY
 DRAINED IN A MANNER THAT WILL PREVENT ANY DRAINAGE
 DISCHARGE TO ANY PROPERTY CONTIGUOUS TO THE SIDE OR
 REAR PROPERTY LINES.
  
 FOR ADDITIONAL INFORMATION, THE ZONING AND LAND
 DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT
 WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH
 PLANNING DEPARTMENT WEBSITE AT
 WWW.CITYOFWPB.COM/PLAN/INDEX.HTM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 MAGGIE CRUZ
 ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: 561-822-1442
 E-MAIL: [email protected]