Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2018-12-13 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-12-13 |
Time |
06:50 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2018-12-13 |
Time |
06:45 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2018-12-14 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2018-12-14 |
Time |
13:28 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2018-12-14 |
Time |
13:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2018-11-15 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2018-11-15 |
Time |
13:51 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2018-11-15 |
Time |
13:50 |
Sent To |
|
|
Notes |
2018-11-15 13:53:51 | FLORIDA BUILDING CODE 2017 6TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | NFPA 70 2014 EDITION | | | | JAKE LEAHY | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | ACCORDING TO THE ORIGINAL PLANS PANEL "B" SUBFED PANEL | | "C" | | | | NOT ALL ACS WHERE INSTALLED IN "B" PLEASE SUBMIT PANEL | | SCHEDULES FOR PANEL "B" FOR COMPARISON. | | IF AC LOADS ARE ALL LOCATED IN PANEL "B PLEASE SUBMIT A | | PANEL "A" PANEL SCHEDULE. |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
P |
Date |
2018-11-30 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2018-11-30 |
Time |
11:50 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2018-11-30 |
Time |
11:50 |
Sent To |
|
|
Notes |
2018-11-30 11:51:16 | 11/30/18 REVIEWED FOR CODE COMPLIANCE (GAS) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVE PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-12-13 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2018-12-14 |
Time |
06:50 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2018-11-02 |
Time |
11:37 |
Sent To |
|
|
Notes |
2018-11-06 11:37:51 | ROUTED TO ZONING INBOX |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2018-11-09 |
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2018-11-09 |
Time |
09:00 |
Rev Time |
0.00 |
Received By |
mcruz |
Date |
2018-11-09 |
Time |
08:56 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy