Plan Review Details - Permit 18101375
Plan Review Stops For Permit 18101375
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2018-12-06 Cont ID  
Sent By cthroop Date 2018-12-06 Time 10:17 Rev Time 0.00
Received By cthroop Date 2018-12-06 Time 09:06 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2018-11-16 Cont ID  
Sent By cthroop Date 2018-11-16 Time 15:46 Rev Time 0.00
Received By cthroop Date 2018-11-16 Time 15:29 Sent To  
Notes
2018-11-16 15:54:10BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 2ND REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE A THIRD SIGNED AND SEALED PLAN SHEET PAGE
 S-1.
 2. PROVIDE THREE COPIES OF THE RESIDENT INSPECTOR FORM
 WITH ORIGINAL SIGNATURES AND SEALS. A COPY IS PROVIDED
 FOR YOUR REVIEW AND USE.
 3. COMPLETE AND SUBMIT PAGES 14, 15 & 16 WITH
 APPLICATION. PAGE 21 SHALL BE SUBMITTED AT FINAL
 INSPECTION.
 4. A RESIDENT INSPECTOR MUST BE A FLORIDA LICENSED
 ARCHITECT OR ENGINEER.
 5. MR. MOCK MAY PROVIDE INSPECTIONS PER FS 468.
 6. PROVIDE A THIRD COPY OF THE INSULATION DATA SHEETS.
  
 FEEL FREE TO CALL IF I CAN BE OF FURTHER ASSISTANCE.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-11-06 Cont ID  
Sent By cthroop Date 2018-11-06 Time 16:04 Rev Time 0.00
Received By cthroop Date 2018-11-03 Time 12:11 Sent To  
Notes
2018-11-06 16:09:28BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. RESIDENT INSPECTOR REQUIRED. A COPY OF THE CURRENT
 RI FORM HAS BEE INCLUDED IN YOUR SUBMITTAL FOR YOUR
 REVIEW AND USE.
 110.3.9 OTHER INSPECTIONS SERVICES. THE BUILDING
 OFFICIAL MAY MAKE, OR CAUSE TO BE MADE BY OTHERS, THE
 INSPECTIONS REQUIRED BY SECTION 110. HE/SHE MAY ACCEPT
 REPORTS OF INSPECTORS OF RECOGNIZED INSPECTION
 SERVICES, PROVIDED THAT AFTER INVESTIGATION HE/SHE IS
 SATISFIED AS TO THEIR QUALIFICATIONS AND RELIABILITY. A
 CERTIFICATE CALLED FOR BY ANY PROVISION OF THE
 TECHNICAL CODES SHALL NOT BE BASED ON SUCH REPORTS
 UNLESS THE SAME ARE IN WRITING AND CERTIFIED BY A
 RESPONSIBLE OFFICER OF SUCH SERVICE. THE BUILDING
 OFFICIAL MAY REQUIRE THE OWNER TO EMPLOY AN INSPECTION
 SERVICE IN THE FOLLOWING INSTANCES:
  
 1. FOR BUILDINGS OR ADDITIONS OF TYPE I OR II
 CONSTRUCTION
 2. FOR ALL MAJOR STRUCTURAL ALTERATIONS
 3. WHERE THE CONCRETE DESIGN IS BASED ON COMPRESSIVE
 STRENGTH (F ?C) IN EXCESS OF 3000 POUNDS PER SQUARE
 INCH
 4. FOR PILE DRIVING
 5. FOR BUILDINGS WITH AREA GREATER THAN 20,000 SQUARE
 FOOT
 6. FOR BUILDINGS MORE THAN 2 STORIES IN HEIGHT
 7. FOR BUILDINGS AND STRUCTURES OF UNUSUAL DESIGN OR
 METHODS OF CONSTRUCTION
  
 SUCH INSPECTORS SHALL BE ADEQUATELY PRESENT AT TIMES
 WORK IS UNDERWAY ON THE STRUCTURAL ELEMENTS OF THE
 BUILDING. SUCH INSPECTORS SHALL BE A REGISTERED
 ARCHITECT, OR ENGINEER, OR A PERSON LICENSED UNDER
 CHAPTER 468, PART XII, FLORIDA STATUTES.
 SUCH INSPECTORS SHALL SUBMIT WEEKLY PROGRESS REPORTS
 INCLUDING THE DAILY INSPECTIONS TO THE BUILDING
 OFFICIAL, AND INCLUDING A CODE COMPLIANCE OPINION OF
 THE RESIDENT INSPECTOR.
 AT THE COMPLETION OF THE CONSTRUCTION WORK OR PROJECT,
 SUCH INSPECTORS SHALL SUBMIT A CERTIFICATE OF
 COMPLIANCE TO THE BUILDING OFFICIAL, STATING THAT THE
 WORK WAS DONE IN COMPLIANCE WITH THIS CODE AND IN
 ACCORDANCE WITH THE PERMITTED DRAWING. FINAL INSPECTION
 SHALL BE MADE BY THE BUILDING OFFICIAL BEFORE A
 CERTIFICATE OF OCCUPANCY OR CERTIFICATE OF COMPLETION
 IS ISSUED; AND CONFIRMATION INSPECTIONS MAY BE MADE AT
 ANY TIME TO MONITOR ACTIVITIES AND RESIDENT INSPECTORS.
 1. RESIDENT INSPECTOR AGREEMENT SHALL BE COMPLETED AND
 SUBMITTED IN TRIPLICATE.
 2. PROVIDE RESUME OF RESIDENT INSPECTOR.
 3. PROVIDE RESUME OF JOB INSPECTOR IF DIFFERENT FROM
 RESIDENT INSPECTOR ? (P.E., ARCH. OR 468 INSPECTOR).
 4. PROVIDE LIST OF SIMILAR PROJECTS COMPLETED BY
 CONTRACTOR.
 5. PROVIDE STRUCTURAL INSPECTION PLAN.
  
 2. PROVIDE R-VALUE FOR PROPOSED INSULATION.
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2018-12-06 Cont ID  
Sent By cthroop Date 2018-12-06 Time 10:17 Rev Time 0.00
Received By cthroop Date 2018-11-28 Time 14:08 Sent To  
Notes
2018-11-29 14:08:46RESUB ROUTED TO CTHROOP

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-11-16 Cont ID  
Sent By cthroop Date 2018-11-16 Time 15:54 Rev Time 0.00
Received By cthroop Date 2018-11-15 Time 09:38 Sent To  
Notes
2018-11-16 09:38:52RESUB ROUTED TO CTHROOP

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-11-06 Cont ID  
Sent By cthroop Date 2018-11-06 Time 16:09 Rev Time 0.00
Received By cthroop Date 2018-10-30 Time 10:54 Sent To  
Notes
2018-11-01 10:54:55BLDG MISC 1