2018-12-06 08:29:05 | ****CORRECTIONS**** |
| W.P.B. PERMIT: 18101067 |
| REVIEWED: DECEMBER 6, 2018 |
| |
| DYLAN BATTLES |
| BUILDING PLANS EXAMINER I |
| [email protected] |
| 561-805-6718 |
| |
| FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) |
| FBC AMENDED = FLORIDA BUILDING CODE,6TH EDITION (2017) |
| FBC B = FBC BUILDING |
| FBC EB = FBC EXISTING BUILDING |
| FBC A = FBC ACCESSIBILITY |
| FBC ENERGY = FBC ENERGY CONSERVATION |
| FBC R = FBC RESIDENTIAL |
| |
| 1. [FBC 107.2.1]ALL INFORMATION, DRAWINGS, |
| SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE |
| NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE |
| DESIGN. |
| PLEASE ADD NAME AND SIGNATURE OF DESIGNER TO EACH SHEET |
| WITHIN THE PLANS (SEAL IS NOT REQUIRED) |
| A) SHEET 01 JUST ADD NAME. |
| B) SHEETS 02-05 NEED NAME AND SIGNATURE. |
| |
| 2. [FBC R702.4.1]GENERAL. CERAMIC TILE SURFACES SHALL |
| BE INSTALLED |
| IN ACCORDANCE WITH ANSI A108.1, A108.4, A108.5, |
| A108.6, A108.11, A118.1, A118.3, A136.1 AND A137.1. |
| R702.4.2 BACKER BOARDS. MATERIALS USED AS BACKERS FOR |
| WALL TILE IN TUB AND SHOWER AREAS AND WALL PANELS IN |
| SHOWER |
| AREAS SHALL BE OF MATERIALS LISTED IN TABLE R702.4.2, |
| AND |
| INSTALLED IN ACCORDANCE WITH THE MANUFACTURER?S |
| RECOMMENDATIONS. |
| VERIFY GYPSUM LIMITATIONS IN PRODUCT SPEC SHEET THAT |
| PRODUCT CAN BE INSTALLED IN SHOWER AREA. |
| |
| 3. [FBC R308.4.5]GLAZING AND WET SURFACES |
| SAFETY GLASS TO BE USED AT SHOWER CATEGORY |
| CLASSIFICATION II OR A. |
| |
| NOTE: |
| -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS |
| OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) |
| SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT |
| DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER |
| SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" |
| OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS |
| APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE |
| NEED "VOID", RENDERING THEM NOT USABLE. |
| |