Plan Review Details - Permit 18100919
Plan Review Stops For Permit 18100919
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2018-10-29 Cont ID  
Sent By skennedy Date 2018-10-29 Time 11:12 Rev Time 0.00
Received By skennedy Date 2018-10-29 Time 11:11 Sent To Z
Notes
2018-10-29 11:26:47SUBJECT TO SECTION 3103
 TEMPORARY STRUCTURES

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2018-10-23 Cont ID  
Sent By jleahy Date 2018-10-22 Time 18:14 Rev Time 0.00
Received By jleahy Date 2018-10-22 Time 18:14 Sent To  
Notes
2018-10-22 18:21:08FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 HOW IS THE LIGHTING TO BE DONE IN THE DIFFERENT ROOMS
 OR IS THIS GOING TO BE OPEN TO EXISTING CEILING?
  
 NOTES SAY THAT THIS WILL BE PLUGIN TO EXISTING OUTLETS
 PLEASE ELABORATE ON HOW THIS WILL BE ACOMPLISHED.
  
 HOW WILL EXIT AND EMERGENCY LIGHTS BE WIRED INTO THE
 SHOW?
  
 PLANS SHOW SOME KIND OF TRUSS SYSTEM FOR LIGHTING, THIS
 WAS NOT EXISTING IN OLD STORE.(?)
  
 SHOW RISER WITH FEEDER OR BRANCH CIRCUITS TO DIMMER
 RACKS

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2018-10-23 Cont ID  
Sent By pleduc Date 2018-10-23 Time   Rev Time 0.00
Received By pleduc Date 2018-10-23 Time 14:45 Sent To E
Notes
2018-10-23 14:57:38THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
 1) SHEET ALS 1.1 - ADD AN ADDITIONAL EXIT SING IN ZONE
 4 ROOM IN THE PATH OF TRAVLE AS SHOWN.
  
 FIRE INSPECTOR WILL VERIFY ON FIRE INSPECTION
  
  
  
 2) SHEET ALS 1.2 - THERE ARE TWO EXITS SIGNS OVER DOORS
 THAT LEAD INTO A GRAYED-OUT AREA. THESE EXIT SIGNS ARE
 NOT LOCATED ON THE PREVIOUS SHEET.
  
 WHERE DO THESE EXIT DOORS LEAD? ADITIONAL EXIT SIGNAGE
 MAY BE NEEDED WITHIN THE GRAY AREA TO LEAD TO THE
 NEAREST EXIT.
  
 FIRE INSPECTOR WILL VERIFY ON FIRE INSPECTION
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-10-31 Cont ID  
Sent By cpuell Date 2018-10-31 Time 11:39 Rev Time 0.00
Received By cpuell Date 2018-10-19 Time 14:30 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2018-10-22 Cont ID  
Sent By skennedy Date 2018-10-22 Time 14:40 Rev Time 0.00
Received By skennedy Date 2018-10-22 Time 14:40 Sent To  
Notes
2018-10-22 14:41:11NO HVAC WORK TO BE DONE, EXISTING.

Review Stop P PLUMBING
Rev No 1 Status N Date 2018-10-22 Cont ID  
Sent By skennedy Date 2018-10-22 Time 14:41 Rev Time 0.00
Received By skennedy Date 2018-10-22 Time 14:41 Sent To  
Notes
2018-10-22 14:41:55NO PLUMBING WORK TO BE DONE, EXISTING FIXTURES ARE
 ADEQUATE.

Review Stop Z ZONING
Rev No 1 Status P Date 2018-10-30 Cont ID  
Sent By aaponte Date 2018-10-30 Time 16:38 Rev Time 0.25
Received By eschneid Date 2018-10-30 Time 16:38 Sent To PC
Notes
***NONE***