Plan Review Details - Permit 18100875
Plan Review Stops For Permit 18100875 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2018-12-03 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-12-03 |
Time |
14:52 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-12-03 |
Time |
14:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2018-11-05 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2018-11-05 |
Time |
11:27 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-11-05 |
Time |
10:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2018-11-20 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2018-11-20 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2018-11-20 |
Time |
12:48 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2018-10-31 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2018-10-31 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2018-10-31 |
Time |
11:22 |
Sent To |
B |
|
Notes |
2018-10-31 11:27:50 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | | 1) THE SUBMITTED PLANS DO NOT INDICATE CLEARLY WHERE | | THE FENCE IS BEING PLACED. | | | | IT APPEARS THE FENCE SURROUNDS THE ENTIRE SITE. | | | | | | PLEASE CLEARLY INDICATED ALL THE LOCATION OF THE FENCE. | | | | | | | | | | 2) THE SUBMITTED PLANS DO NOT CLEARLY SHOW THE | | CONSTRUCTION AREA AND HOW THE EXITING OF THE BUILDING | | OR SPACES WILL BE AFFECTED. | | | | PLEASE REVIEW AND PROVIDE A LIFE SAFETY PLAN SHOWING | | THE EXITS OF THE BUILDING IN RELATION TO THE FENCE | | LOCATIONS. | | | | | | | | 3) THE SUBMITTED PLANS DO NOT SHOW AREAS ON HOW THE | | FIRE DEPARTMENT CAN ACCESS THE BUILDING, LOCATIONS OF | | FDC AND THEIR ACCESS. | | | | THE FD REQUIRES 20' FIRE LANE ACCESS TO THE BUILDING. | | | | PLEASE REVIEW AND PROVIDE DETAILS ON HOW AND WHERE THE | | FD WILLL ACCESS THE SITE AND BUILDING. | | | | | | | | 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | | | 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-12-03 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-12-03 |
Time |
14:52 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-11-15 |
Time |
16:14 |
Sent To |
|
|
Notes |
2018-11-20 09:57:06 | ROUTED FROM ZONING TO PERMIT LIBRARIAN 11/20/18 | 2018-11-15 16:14:58 | RESUB ROUTED TO ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-11-05 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-11-05 |
Time |
11:04 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-10-18 |
Time |
15:08 |
Sent To |
|
|
Notes |
2018-10-30 11:44:47 | ROUTED FROM ZONING TO LM 10/30/2018 | 2018-10-19 15:08:34 | ROUTED TO ZONING INBOX |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2018-11-20 |
|
|
Cont ID |
|
Sent By |
elevesqu |
Date |
2018-11-20 |
Time |
09:56 |
Rev Time |
0.00 |
Received By |
elevesqu |
Date |
2018-11-20 |
Time |
09:56 |
Sent To |
FIRE |
|
Notes |
2018-11-20 09:56:48 | PROVISO: TEMPORARY FENCE TO BE REMOVED PRIOR TO | | ISSUANCE OF CO OR CC. | | | | LIZ LEVESQUE, URBAN DESIGN PLANNER | | [email protected] | | 561 822 1426 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2018-10-30 |
|
|
Cont ID |
|
Sent By |
elevesqu |
Date |
2018-10-30 |
Time |
11:44 |
Rev Time |
0.00 |
Received By |
elevesqu |
Date |
2018-10-30 |
Time |
11:40 |
Sent To |
FIRE |
|
Notes |
2018-10-30 11:44:28 | PLEASE SUBMIT SCREENING GRAPHICS- | | PER SECTION 94-316, SCREENING DETAILS SHALL BE | | SUBMITTED WITH THE TEMPORARY CONSTRUCTION FENCE PERMIT | | APPLICATION. WIND SCREENING SHALL BE SUBSTANTIAL ENOUGH | | TO AVOID RIPS OR TEARS DUE TO WIND OR SUN, AND SHALL | | HAVE NO LESS THAN 85 PERCENT OPACITY. SCREENING SHALL | | BE MAINTAINED IN GOOD CONDITION AT ALL TIMES. SCREENING | | GRAPHICS SHALL BE APPROVED WITH A PERMIT PURSUANT TO | | THE PROVISIONS OF CHAPTER 94, ARTICLE XIII, SIGN | | REGULATIONS, OF THE ZONING AND LAND DEVELOPMENT | | REGULATIONS OF THIS CODE. | | | | PLEASE NOTE, ANY PROPOSED TEMPORARY FENCE SIGNAGE SHALL | | BE REVIEWED THROUGH SEPARATE PERMIT. | | | | PLEASE NOTE, TEMPORARY CONSTRUCTION FENCES MAY NOT BE | | ERECTED MORE THAN TEN DAYS PRIOR TO THE COMMENCEMENT OF | | LAND DISTURBING CONSTRUCTION OR LAND DEVELOPMENT | | ACTIVITIES. | | | | LIZ LEVESQUE, URBAN DESIGN PLANNER | | [email protected] (PREFERRED) | | 561 822 1426 |
|
|
|