Plan Review Details - Permit 18100634
Plan Review Stops For Permit 18100634
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-02-05 Cont ID  
Sent By dbattles Date 2019-02-05 Time 07:55 Rev Time 0.00
Received By dbattles Date 2019-02-05 Time 07:55 Sent To  
Notes
2019-02-05 07:57:11PROVISO:
 -SUBMIT TRUSS SHOP DRAWINGS TO THE BUILDING INSPECTOR
 PRIOR TO INSTALLATION.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-12-03 Cont ID  
Sent By dbattles Date 2018-12-03 Time 13:55 Rev Time 0.00
Received By dbattles Date 2018-11-30 Time 13:41 Sent To  
Notes
2018-12-03 13:58:11****CORRECTIONS****
 W.P.B. PERMIT: 18100634
 REVIEWED: NOVEMBER 30, 2018
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER I
 [email protected]
 561-805-6718
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC AMENDED = FLORIDA BUILDING CODE,6TH EDITION (2017)
 FBC A = FBC ACCESSIBILITY
 FBC ENERGY = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. [FBC 107.3.5.3]PROVIDE SEDIMENT CONTROL TO KEEP
 CONSTRUCTION DEBRIS FROM ENTERING ADJACENT PROPERTIES
 AND STORM DRAINS DURING CONSTRUCTION.
 YOU CAN JUST ADD SILT FENCE DETAIL AND HOW DRAINS ARE
 PROTECTED TO THE DRAINAGE PLAN.
 SOME ENGINEERING STANDARD DETAILS CAN BE USED FROM WPB
 WEBSITE-POLLUTION CONTROL.
 HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS
 /FORMS,-PERMITS-APPLICATIONS
  
 2. [FBC 107.5][FBC 110.9][FBC R401.3][PROVIDE SITE
 DRAINAGE PLAN.
 SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER
 CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT
 DOES NOT CREATE A HAZARD. LOTS SHALL BE GRADED TO DRAIN
 SURFACE WATER AWAY FROM FOUNDATION WALLS. THE GRADE
 SHALL FALL A MINIMUM OF 6 INCHES (152 MM) WITHIN THE
 FIRST 10 FEET (3048 MM).
 EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER
 PHYSICAL BARRIERS PROHIBIT 6 INCHES (152 MM) OF FALL
 WITHIN 10 FEET (3048 MM), DRAINS OR SWALES SHALL BE
 CONSTRUCTED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE.
 IMPERVIOUS SURFACES WITHIN 10 FEET (3048 MM) OF THE
 BUILDING FOUNDATION SHALL BE SLOPED A MINIMUM OF 2
 PERCENT AWAY FROM THE BUILDING.
 THIS CAN BE SHOWN ON THE SITE PLAN THAT IS REQUESTED
 FROM
  
 3. [FBC R807]CO-ORDINATE ATTIC ACCESS SHOWN ON SHEET A1
 WITH TRUSS LAYOUT ON SHEET S2. SHEET A1 SHOWS ACCESS
 CENTERED IN RROM, BUT SHEET S2 SHOWN TRUSS DOWN THE
 CENTER OF ROOM.
  
 4. [FBC R806.5]UNVENTED ATTIC AND UNVENTED ENCLOSED
 RAFTER
 ASSEMBLIES. UNVENTED ATTICS AND UNVENTED ENCLOSED ROOF
 FRAMING ASSEMBLIES CREATED BY CEILINGS THAT ARE APPLIED
 DIRECTLY TO THE UNDERSIDE OF THE ROOF FRAMING MEMBERS
 AND
 STRUCTURAL ROOF SHEATHING APPLIED DIRECTLY TO THE TOP
 OF THE ROOF
 FRAMING MEMBERS/RAFTERS, SHALL BE PERMITTED WHERE ALL
 THE FOLLOWING
 CONDITIONS ARE MET:
 A. THE UNVENTED ATTIC SPACE IS COMPLETELY WITHIN THE
 BUILDING THERMAL ENVELOPE.
 SHEET A-3 NOTE SAYS FOAM INSULATION AND NO VENTS. IF NO
 VENTS THE ATTIC SPACE NEEDS TO BE IN THE THERMAL
 ENVELOPE. ICYNENE OR EQUIVALENT WOULD BE APPLIED UNDER
 ROOF DECK.
 IF IT IS TO BE ON THE ATTIC BOTTOM CHORD PROVIDE VENT
 CALCULATIONS FOR THE ATTIC SPACE.
  
 5. [FBC R302.10]PROVIDE CUT SHEET FOR ICYNENE(ICC-ES
 REPORT OR EQUAL) WITH THE TYPE SELECTED TO ESTABLISH
 THICKNESS NEEDED TO MEET REQUIRED R-VALUE, FLAME SPREAD
 INDEX AND SMOKE DEVELOPED INDEX.
  
 6. [FBC R316.5.3]IF MECHANICAL EQUIPMENT IN THE ATTIC
 SPACE THAN IT REQUIRES IGNITION BARRIER. IF AIR HANDLER
 WILL BE IN ATTIC ADD NOTE FOR IGNITION BARRIER.
  
 7. [FBC AMENDED 107.3.4.1]PROVIDE PRODUCT APPROVAL FOR
 WINDOW MULL TO GO WITH SINGLE HUNG WINDOW NOA
 17-0630.08
  
 8. [FBC AMENDED 107.3.4.1]SUBMIT TRUSS SHOP DRAWINGS TO
 THE BUILDING INSPECTOR PRIOR TO INSTALLATION.
 THIS WILL BE A PROVISO ITEM THAT DOES NOT NEED TO BE
 ADDRESSED.
  
 NOTE:
 -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
 -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW
 OF MATERIALS REQUESTED.
 -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS
 OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS)
 SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT
 DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER
 SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID"
 OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS
 APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE
 NEED "VOID", RENDERING THEM NOT USABLE.
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-02-03 Cont ID  
Sent By jpearson Date 2019-02-03 Time 09:53 Rev Time 0.00
Received By jpearson Date 2019-02-03 Time 09:53 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-11-30 Cont ID  
Sent By jpearson Date 2018-11-30 Time 09:31 Rev Time 0.00
Received By jpearson Date 2018-11-30 Time 07:37 Sent To  
Notes
2018-11-30 09:31:31CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
 (S)
  
 1. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS
 LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND
 VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS
 IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. FBC 109.3
 2. PLAN APPROVED WITH PROVISO FOR LOCATION OF SMOKE
 ALARMS (MUST BE THREE FEET FROM BATHROOM), AFCI
 PROTECTION (MUST INCLUDE ALL AREAS PER CURRENT FBC RE)
 AND DISHWASHER (MUST BE GFCI PROTECTED). PROVISO NOTED
 ON PLANS.
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2019-02-01 Cont ID  
Sent By fmittner Date 2019-02-01 Time 15:10 Rev Time 0.00
Received By fmittner Date 2019-02-01 Time 15:10 Sent To  
Notes
2019-02-01 15:11:04APPROVED WITH PROVISO TO RAISE PARAPET WALL HEIGHT.

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2018-11-28 Cont ID  
Sent By fmittner Date 2018-11-28 Time 16:00 Rev Time 0.00
Received By fmittner Date 2018-11-28 Time 16:00 Sent To  
Notes
2018-11-28 16:03:50MUST ADDRESS COMMENTS BY HISTORIC PRESERVATION BOARD.
 SPOKE TO FRED ON 11/28/18.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status P Date 2019-02-14 Cont ID  
Sent By rmcdouga Date 2019-02-14 Time 16:37 Rev Time 0.00
Received By rmcdouga Date 2019-02-14 Time 16:37 Sent To  
Notes
2019-02-14 16:38:50MU-2019-4572, PAID $9766.49

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-02-05 Cont ID  
Sent By jesmith Date 2019-02-05 Time 08:47 Rev Time 0.00
Received By jesmith Date 2019-02-05 Time 08:47 Sent To  
Notes
2019-01-16 15:57:51R16

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-12-07 Cont ID  
Sent By cpuell Date 2018-12-07 Time 16:27 Rev Time 0.00
Received By cpuell Date 2018-10-12 Time 12:47 Sent To  
Notes
2018-11-29 15:51:42R21
2018-10-15 12:47:22LIBRARY

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2019-02-14 Cont ID  
Sent By rmcdouga Date 2019-02-14 Time 16:49 Rev Time 0.00
Received By rmcdouga Date 2019-02-14 Time 16:49 Sent To  
Notes
2019-02-14 16:50:40MU-2019-4572, PAID $9,766.49

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2018-12-03 Cont ID  
Sent By dbattles Date 2018-12-03 Time 13:58 Rev Time 0.00
Received By dbattles Date 2018-12-03 Time 13:58 Sent To  
Notes
2018-12-03 13:59:21DYLAN BATTLES
 BUILDING PLANS EXAMINER I
 [email protected]
 561-805-6718
  
 [FBC AMENDED 109]PLANS REQUIRE REVIEW BY THE PBC IMPACT
 FEE OFFICE. CALL (561) 233-5025. UPON APPROVAL, YOU MAY
 CHECK OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR
 REVIEW. PLEASE RETURNED STAMPED AND WITH A COPY OF THE
 RECEIPT AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO THE PBC IMPACT FEE
 OFFICE. THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGO
 V.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONN
 AIRE.PDF
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2019-02-14 Cont ID  
Sent By rmcdouga Date 2019-02-14 Time 16:55 Rev Time 0.00
Received By rmcdouga Date 2019-02-14 Time 16:55 Sent To  
Notes
2019-02-14 16:56:28APPROVED BY CHRIS THROOP ON 2/7/2019.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2019-02-04 Cont ID  
Sent By cmontell Date 2019-02-04 Time 14:29 Rev Time 0.00
Received By cmontell Date 2019-02-04 Time 13:56 Sent To  
Notes
2019-02-04 14:29:17MECHANICAL PLAN REVIEW FAIL
  
 1 - NEED SIGNATURE ON BUILDING ECERGY CARD PER 2017
 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION SEC. R103.1.1.2 CODE COMPLIANCE CERTIFICATION.
  
 2 - NEED RETURN AIR IN BED ROOMS PER 2017 FLORIDA
 BUILDING CODE - RESIDENTIAL, SIXTH EDITION SEC. M1602.3
 BALANCED RETURN AIR.
  
 CHRIS MONTELLO
 561-805-6733

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2018-12-07 Cont ID  
Sent By cmontell Date 2018-12-07 Time 14:32 Rev Time 0.00
Received By cmontell Date 2018-12-07 Time 14:32 Sent To I
Notes
2018-12-07 14:45:42MECHANICAL PLAN REVIEW FAIL
  
 1 - NEED MECHANICAL PLANS PER AMENDMENTS TO THE FLORIDA
 BUILDING CODE, 6TH EDITION (2017), CHAPTER 1,
 ADMINISTRATION, SEC. 107.2.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS.
  
 CHRIS MONTELLO
 561-805-6733
  
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-02-05 Cont ID  
Sent By jesmith Date 2019-02-05 Time 08:38 Rev Time 0.00
Received By jesmith Date 2019-02-05 Time 08:32 Sent To  
Notes
2019-02-05 08:38:00APPROVED
 PROVISO
 ALL WORK PER CITY CODES SUBJECT TO FIELD INSPECTOR'S
 APPROVAL

Review Stop P PLUMBING
Rev No 1 Status F Date 2018-12-04 Cont ID  
Sent By jesmith Date 2018-12-04 Time 09:13 Rev Time 0.00
Received By jesmith Date 2018-12-04 Time 09:12 Sent To  
Notes
2018-12-04 09:12:381ST REVIEW:
 PLUMBING COMMENTS: DENIED
  
 1. RE: PLAN SHEET E-1, SANITARY RISER DIAGRAM
 A) MASTER BATH; THE DRY VENTS AT THE SHOWER AND THE TWO
 LAVATORIES EXTEND HORIZONTALLY BEFORE RISING
 VERTICALLY. THIS IS PROHIBITED PER FBC RES P3104.3.
 B) MASTER BATH; THE FIXTURE DRAINS FOR THE SHOWER AND
 BOTH LAVATORIES RISE VERTICALLY ABOVE THE VENT BEFORE
 CONNECTING TO THE TRAP. THIS IS PROHIBITED PER FBC RES
 P3105.2 AND P3201.5.3.
 C) BATH #2; THE FIXTURE DRAIN FOR THE SHOWER RISES
 VERTICALLY ABOVE THE VENT BEFORE CONNECTING TO THE
 TRAP. THIS IS PROHIBITED PER FBC RES P3105.2 AND
 P3201.5.3.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED "VOID".
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715
  
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2019-02-14 Cont ID  
Sent By dbattles Date 2019-02-14 Time 16:45 Rev Time 0.00
Received By dbattles Date 2019-02-14 Time 16:45 Sent To  
Notes
2019-02-14 16:46:1316-0425.01 PRODUCT APPROVAL FOR SHINGLES - OK

Review Stop Z ZONING
Rev No 2 Status P Date 2019-02-12 Cont ID  
Sent By fmittner Date 2019-02-01 Time 15:11 Rev Time 0.00
Received By fmittner Date 2019-02-01 Time 15:11 Sent To  
Notes
2019-02-12 11:28:05LANDSCAPE PERMIT SUBMITTED SEPARATELY.
2019-02-01 15:15:45LANDSCAPE PLAN NEEDS TO BE A SEPARATE PERMIT. PLAN WITH
 SETBACK TO BE LABELED AS SITE PLAN

Review Stop Z ZONING
Rev No 1 Status F Date 2018-11-28 Cont ID  
Sent By fmittner Date 2018-11-28 Time 16:01 Rev Time 0.00
Received By fmittner Date 2018-11-28 Time 16:01 Sent To  
Notes
2018-11-28 16:06:22NEED SITE PLAN AND SEPERATE LANDSCAPE PERMIT.