Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-11-02 Cont ID  
Sent By dbattles Date 2018-11-02 Time 16:29 Rev Time 0.00
Received By dbattles Date 2018-11-02 Time 16:29 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-10-18 Cont ID  
Sent By dbattles Date 2018-10-18 Time 08:58 Rev Time 0.00
Received By dbattles Date 2018-10-18 Time 08:58 Sent To  
Notes
2018-10-18 08:59:48****CORRECTIONS****
 W.P.B. PERMIT: 18100586
 REVIEWED: OCTOBER 11, 2018
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER I
 [email protected]
 561-805-6718
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC AMENDED = FLORIDA BUILDING CODE,6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC ENERGY = FBC ENERGY CONSERVATION
  
 1. [FBC 1503.4]PROVIDE EXISTING SCUPPERS SIZING TO MEET
 DRAINAGE REQUIREMENTS IN FBC PLUMBING CHAPTER 11. IF
 ROOF DRAINS SHOW LOCATIONS ON SKETCH.
  
 2. [FBC 1505.1]PLEASE PROVIDE THE TYPE OF CONSTRUCTION
 AND THE FIRE CLASSIFICATION OF NEW ROOF SYSTEM.
  
 3. [FBC 1508.1]PROVIDE ENGINEERING FOR THE NEW
 INSULATION ATTACHMNET (SEE NOTE #2 ON FL-11475-R8)
  
 4. [FBC 1507.10.1]ADD MINIMUM ROOF SLOPE TO SKETCH.
  
 NOTE:
 -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW
 OF MATERIALS REQUESTED.
 -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS
 OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS)
 SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT
 DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER
 SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID"
 OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS
 APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE
 NEED "VOID", RENDERING THEM NOT USABLE.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-11-02 Cont ID  
Sent By dbattles Date 2018-11-02 Time 16:29 Rev Time 0.00
Received By dbattles Date 2018-10-31 Time 15:33 Sent To  
Notes
2018-11-01 15:33:58RESUB ROUTED TO DBATTLES

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-10-18 Cont ID  
Sent By dbattles Date 2018-10-18 Time 08:58 Rev Time 0.00
Received By dbattles Date 2018-10-12 Time 09:45 Sent To  
Notes
2018-10-15 09:45:44DBATTLES


Account Summary | Usage Policy | Privacy Policy