Plan Review Details - Permit 18100235
Plan Review Stops For Permit 18100235 |
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-10-23 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2018-10-23 |
Time |
09:26 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2018-10-18 |
Time |
15:00 |
Sent To |
|
|
Notes |
2018-10-19 15:00:19 | RESUB ROUTED TO TKLARGE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-10-10 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2018-10-10 |
Time |
10:04 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2018-10-04 |
Time |
13:32 |
Sent To |
|
|
Notes |
2018-10-05 13:32:57 | PLUMB <5K |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2018-10-23 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2018-10-23 |
Time |
09:26 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2018-10-22 |
Time |
14:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2018-10-10 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2018-10-10 |
Time |
10:04 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2018-10-10 |
Time |
09:00 |
Sent To |
I |
|
Notes |
2018-10-10 09:21:20 | 1) SUBMIT MANUFACTURER'S SPECIFICATIONS & INSTALLATION | | MANUAL FOR THE BATHTUB.THE BATHTUB SHALL COMPLY WITH | | THE STANDARDS LISTED IN 2017 FBC-RESIDENTIAL TABLE | | P2701.1. | | 2) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE BATHTUB | | VALVE. HOT WATER SUPPLIED TO BATHTUBS SHALL BE LIMITED | | TO 120 DEGREES FAHRENHEIT AND SHALL COMPLY WITH THE | | REQUIREMENTS OF 2017 FBC-RESIDENTIAL SEC.P2713.3. | | 3) SUBMIT A FLOOR PLAN SHOWING THE LOCATION OF THE NEW | | TUB. IS THE TUB BEING ADDED TO AN EXISTING BATHROOM OR | | IS A NEW BATHROOM BEING CREATED? CLARIFY.**NOTE - A | | PREVIOUS PERMIT APPLICATION WAS SUBMITTED FOR THIS IN | | JULY THAT SHOWED THE BATHTUB BEING ADDED IN A DRESSING | | ROOM. THIS WOULD NOW BE CONSIDERED A BATHROOM AND | | COMPLIANCE Y WITH 2017 FBC-RES.SEC. R303.3 FOR REQUIRED | | AGGREGATE GLAZING AND VENTILATION REQUIREMENTS WILL BE | | REQUIRED. REFER TO THE EXCEPTION FOR ALTERNATE | | COMPLIANCE. | | 4) INDICATE ON THE PLAN IF ANY OTHER WORK WILL BE | | ASSOCIATED WITH THIS INSTALLATION ( BUILDING, | | ELECTRICAL, ETC.) AND IF SO SUBMIT A COMPLETE SET OF | | PLANS THAT REFLECT THE ENTIRE SCOPE OF WORK TO BE DONE. | | WPB AMEND. TO FBC SEC. 107.2.1. | | 5) THE WALLS SURROUNDING THE BATHTUB SHALL COMPLY WITH | | THE 2017 FBC-RES. SEC.R307.2. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | |
|
|
|