Plan Review Details - Permit 18100167
Plan Review Stops For Permit 18100167
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2019-02-12 Cont ID  
Sent By jgomez Date 2019-02-12 Time 11:57 Rev Time 0.00
Received By jgomez Date 2019-02-12 Time 11:57 Sent To  
Notes
2019-02-12 11:59:29FINAL INSPECTION PASSED ON 02/04/19 BY TOM MOORE. HE
 RECEIVED THE DRAINAGE CERTIFICATE REQUESTED BY KEN
 CONRAD. JG.
  
  
 RECD DRAINAGE LETTER/FINAL TER

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2019-01-02 Cont ID  
Sent By jgomez Date 2019-01-02 Time 14:18 Rev Time 0.00
Received By jgomez Date 2019-01-02 Time 14:04 Sent To  
Notes
2019-01-02 14:18:43RESIDENTIAL (R3) SECOND BUILDING REVIEW COMMENTS
 CODE: 5TH EDITION (2014) AND CITY AMENDMENTS.
  
 1- KEN CONRAD (CHIEF BUILDING INSPECTOR) PERFORMED A
 MISCELLANEOUS INSPECTION FOR RETAINING WALL AND PAVER'S
 ON 09/12/18. IT LOOKS LIKE THERE ARE SOME PROBLEMS WITH
 WATER DRAINING INTO NEIGHBOR'S PROPERTY. THEREFORE, KEN
 CONRAD REQUESTED THE FOLLOWING "A DRAINAGE CERTIFICATE
 SHALL BE SUBMITTED AT FINAL". CONTRACTOR TO PROVIDE
 "DRAINAGE CERTIFICATE" AT FINAL INSPECTION AS REQUESTED
 BY KEN CONRAD.
 NOTE: COORDINATE WITH KEN CONRAD (CHIEF BUILDING
 INSPECTOR).
  
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-12-04 Cont ID  
Sent By jgomez Date 2018-12-04 Time 10:10 Rev Time 0.00
Received By jgomez Date 2018-12-04 Time 09:05 Sent To  
Notes
2018-12-04 09:15:00RESIDENTIAL (R3) BUILDING REVIEW COMMENTS
 CODE: 5TH EDITION (2014) AND CITY AMENDMENTS.
  
 1- KEN CONRAD (CHIEF BUILDING INSPECTOR) PERFORMED A
 MISCELLANEOUS INSPECTION FOR RETAINING WALL AND PAVER'S
 ON 09/12/18. IT LOOKS LIKE THERE ARE SOME PROBLEMS WITH
 WATER DRAINING INTO NEIGHBOR'S PROPERTY. THEREFORE, KEN
 CONRAD REQUESTED THE FOLLOWING "A DRAINAGE CERTIFICATE
 SHALL BE SUBMITED AT FINAL". CONTRACTOR SUBMITTED AN
 "ELEVATION CERTIFICATE" . THIS IS NOT WHAT KEN CONRAD
 REQUESTED. ELEVATION CERTIFICATES ARE ONLY REQUIRED FOR
 PROPERTIES LOCATED IN A SPECIAL FLOOD ZONE. THIS
 PROPERTY IS NO LOCATED IN A FLOOD ZONE. ELEVATION
 CERTIFICATE IS NOT REQUIRED AND WILL NOT BE REVIEWED.
 CONTRACTOR TO SUBMITT "DRAINAGE CERTIFICATE" AS
 REQUESTED BY KEN CONRAD SHOWING THAT THE DRAIN SURFACE
 WATER IS KEPT WITHIN THE LOT AND IS DIVERTED TO AN
 APPROVED POINT OF COLLECTION. SEC. R401.3
 FBC-RESIDENTIAL. NOTE: COORDINATE WITH KEN CONRAD
 (CHIEF BUILDING INSPECTOR).
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE/VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 PLEASE DON'T STAPLE OLD DRAWINGS/DOCUMENTS . SUBMIT OLD
 DRAWINGS/DOCUMENTS FOR REFERENCE.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-01-02 Cont ID  
Sent By jgomez Date 2019-01-02 Time 14:18 Rev Time 0.00
Received By jgomez Date 2019-01-02 Time 14:05 Sent To  
Notes
2019-01-02 14:05:43MAX LOPEZ SUBMITTED DRAINAGE CERTIFICATE LETTER. JG

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2018-12-04 Cont ID  
Sent By jgomez Date 2018-12-04 Time 10:10 Rev Time 0.00
Received By jgomez Date 2018-11-20 Time 16:53 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-10-10 Cont ID  
Sent By jgomez Date 2018-10-10 Time 15:45 Rev Time 0.00
Received By jgomez Date 2018-10-03 Time 09:55 Sent To I
Notes
2018-10-05 09:55:35REVISION ROUTED TO JGOMEZ

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2018-12-04 Cont ID  
Sent By jgomez Date 2018-12-04 Time 09:05 Rev Time 0.00
Received By jgomez Date 2018-12-03 Time 16:27 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2018-10-10 Cont ID  
Sent By jgomez Date 2018-10-10 Time 15:44 Rev Time 0.00
Received By jgomez Date 2018-10-10 Time 14:09 Sent To Z
Notes
2018-10-10 15:44:48RESIDENTIAL (R3) REVISION MECHANICAL REVIEW COMMENTS
 CODE: FBC 5TH EDITION (2014) AND CITY AMENDMENTS.
  
 1- THERE IS AN ENGINEER OF RECORD ON APPROVED
 MECHANICAL PLAN M-1. ENGINEER OF RECORD NEEDS TO SIGN
 AND SEAL REVISED MECHANICAL PLAN. NEED TO HAVE THE
 ORIGINAL SEAL AND SIGNATURE OF THE ENGINEER OF RECORD
 AS REQUIRED BY SEC. 61G15-23.003 FAC AND CHAPTER 471
 F.S. WHEN SUBMITTING PLANS/DOCUMENTS FOR PUBLIC
 RECORDS.
  
 2- THE REVISED TRANSFER DUCT IN THE MASTER BEDROOM
 DOESN'T COMPLY WITH THE BALANCED RETURN AIR SEC.
 M1602.4 FBC-RESIDENTIAL. NEED AT LEAST 13" DUCT.
 ORIGINAL APPROVED PLAN CALLED FOR 14" TRANSFER DUCT AND
 14"X14" RAG. REVISE AS REQUIRED.
  
 3- CLARIFY LOCATION OF A/C COMPRESSOR. THERE IS A
 HANDWRITTEN NOTE STATING THAT COMPRESSOR "MOVED TO WEST
 SIDE". SHOW ACTUAL LOCATION OF COMPRESSOR. HANDWRITTEN
 NOTES ARE NOT ALLOWED. SEC. 107.2.1 CITY AMENDMENTS.
 NOTE: NEED ZONING APPROVAL FOR LOCATION OF A/C
 EQUIPMENT.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2018-11-30 Cont ID  
Sent By jgomez Date 2018-12-04 Time 10:10 Rev Time 0.00
Received By mcruz Date 2018-11-30 Time 09:39 Sent To M
Notes
2018-11-30 09:39:46ZONING PASSED WITH PROVISO: A/C EQUIMENT SHALL BE AT
 LEAST 1' FROM WEST PROPERTY LINE.

Review Stop Z ZONING
Rev No 1 Status F Date 2018-10-16 Cont ID  
Sent By mcruz Date 2018-10-16 Time 16:24 Rev Time 0.00
Received By mcruz Date 2018-10-16 Time 16:08 Sent To PC
Notes
2018-10-16 16:24:05ZONING REVIEW FAILED, DUE TO THE FOLLOWING:
  
 1) PROVIDE 2 COPIES OF THE PROPERTY SURVEY.
 2) INDICATE THE SETBACK DIMENSION FROM THE A/C
 EQUIPMENT TO THE WEST PROPERTY LINE.
  
 FOR ADDITIONAL INFORMATION, THE ZONING AND LAND
 DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT
 WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH
 PLANNING DEPARTMENT WEBSITE AT
 WWW.CITYOFWPB.COM/PLAN/INDEX.HTM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 MAGGIE CRUZ
 ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: 561-822-1442
 E-MAIL: [email protected]
2018-10-10 15:54:09CHANGE OF A/C EQUIPMENT LOCATION.