Plan Review Details - Permit 18100150
Plan Review Stops For Permit 18100150 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2018-10-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-10-11 |
Time |
17:50 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-10-11 |
Time |
17:49 |
Sent To |
|
|
Notes |
2018-10-11 17:51:31 | 10/11/18 RECEIVED REVISED RAS 117 CALCULATIONS FROM | | ENGINEER VIA E-MAIL. JG. | | | | | | 10/11/18 APPROVED. NEED ENGINEER'S CALCULATIONS WITH | | ORIGINAL SEAL & SIGNATURE TO PRINT PERMIT. PERMIT | | PACKAGE UPRONT UNDER "P". JG. | | | | 10/11/18 TALKED TO JOHN AVERKAMP (ENGINEER) RAS 117 | | CALCS ARE OK. NEED ORIGINAL COPIES SIGNED AND SELAED AS | | REQ'D BY F. S. 471. JG. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2018-10-10 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-10-10 |
Time |
12:23 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-10-10 |
Time |
10:37 |
Sent To |
|
|
Notes |
2018-10-10 12:23:00 | RESIDENTIAL (R3) RE-ROOF SECOND BUILDING REVIEW | | CHECKLIST. | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | ORIGINAL COMMENT: | | 1- FLAT ROOF: ENGINEER TO REVISE RAS 117 CALCULATIONS | | SUBMITTED. ENGINEER IS ROUNDING UP THE FASTENER | | SPACING. ACCORDING TO SEC. 104.5 OF RAS 117 THE | | FASTENER SPACING SHALL BE ROUNDED DOWN TO THE NEXT | | WHOLE NUMBER NOT ROUNDED UP. REVISE FASTENER SPACING AS | | REQUIRED. NOTE: KEEP IN MIND THAT THE MINIMUM FASTENER | | SEPARATION SHALL NOT BE LESS THAN 4 INCHES O.C.. SEE | | SEC. 8.1 OF RAS 117. | | | | RESPONSE: | | ENGINEER TO REVISE RAS 117 CALCULATIONS. | | (1) NEED TO USE THE ACTUAL NET WIDTH OF THE ANCHOR | | SHEET AS SHOWN ON THE NOA SUBMITTED. IT LOOKS LIKE THE | | ENGINEER IS USING THE NET WIDTH SHOWN ON THE RAS 117 | | CALCULATIONS SAMPLE NOT THE ACTUAL WIDTH OF NOA | | SUBMITTED. | | (2) ENGINEER SPECIFIES TWO ROWS OF FASTENERS IN A 6" | | SIDE LAP. TWO ROWS IN A 6" LAP DOESN'T SEEM TO COMPLY | | WITH THE MIN. 4"0.C. FASTENER SPACING REQUIRED BY SEC. | | 8.1 OF RAS 117. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2018-10-04 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-10-04 |
Time |
16:26 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-10-04 |
Time |
15:42 |
Sent To |
|
|
Notes |
2018-10-04 16:26:11 | RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | 1- FLAT ROOF: ENGINEER TO REVISE RAS 117 CALCULATIONS | | SUBMITTED. ENGINEER IS ROUNDING UP THE FASTENER | | SPACING. ACCORDING TO SEC. 104.5 OF RAS 117 THE | | FASTENER SPACING SHALL BE ROUNDED DOWN TO THE NEXT | | WHOLE NUMBER NOT ROUNDED UP. REVISE FASTENER SPACING AS | | REQUIRED. NOTE: KEEP IN MIND THAT THE MINIMUM FASTENER | | SEPARATION SHALL NOT BE LESS THAN 4 INCHES O.C.. SEE | | SEC. 8.1 OF RAS 117. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2018-10-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-10-11 |
Time |
17:52 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-10-11 |
Time |
17:49 |
Sent To |
|
|
Notes |
2018-10-11 17:50:46 | RECEIVED REVISED RAS 117 CALCULATIONS FROM ENGINEER VIA | | E-MAIL. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-10-10 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-10-10 |
Time |
12:23 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-10-10 |
Time |
10:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-10-04 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-10-04 |
Time |
16:43 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-10-03 |
Time |
15:08 |
Sent To |
I |
|
Notes |
2018-10-04 15:08:55 | JGOMEZ |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |