Plan Review Stops For Permit 18100037 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2018-11-03 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-11-03 |
Time |
07:57 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-11-03 |
Time |
07:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2018-10-24 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-10-24 |
Time |
07:30 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-10-24 |
Time |
07:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2018-12-03 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2018-12-03 |
Time |
07:47 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2018-12-03 |
Time |
07:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2018-11-30 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2018-11-21 |
Time |
12:49 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2018-11-21 |
Time |
12:48 |
Sent To |
|
|
Notes |
2018-11-21 12:49:30 | STILL THE SAME NO CHANGE TO THE DRAWINGS A # 8 IS NOT | | GOOD FOR 75A |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2018-11-02 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2018-11-02 |
Time |
12:23 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2018-11-02 |
Time |
12:23 |
Sent To |
|
|
Notes |
2018-11-02 12:27:00 | PAGE 6-6/E2 | | | | SHOWS A #8 FROM INVERTER AT 75 AMPERES. #8 IS ONLY GOOD | | FOR 55 AMPERES. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2018-10-04 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2018-10-17 |
Time |
09:45 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2018-10-04 |
Time |
09:45 |
Sent To |
Z |
|
Notes |
2018-10-04 09:48:27 | FLORIDA BUILDING CODE 2017 6TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | NFPA 70 2014 EDITION | | | | JAKE LEAHY | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | PAGE E-2 | | | | RISER SHOW 1/0 AL WITH 150A MAIN, CONDUCTORS ARE ONLY | | GOOD FOR 125A PER CODE. 310.15(B)(16). | | | | #8 FEEDING THE 60A BREAKER ? | | | | YOUR CALCULATION SHOWS THE #8 AT 75 AMPERES? | | 310.15(B)(16) SHOWS 55 AMPERES? | | | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2018-11-21 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2018-11-21 |
Time |
12:49 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2018-11-19 |
Time |
13:56 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-11-03 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-11-03 |
Time |
07:57 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-10-29 |
Time |
10:15 |
Sent To |
|
|
Notes |
2018-10-31 10:15:41 | RESUB ROUTED TO ZONING INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-10-24 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-10-24 |
Time |
07:30 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-10-01 |
Time |
13:43 |
Sent To |
|
|
Notes |
2018-10-02 13:43:47 | ROUTED TO JLEAHY |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2018-10-15 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2018-10-15 |
Time |
14:30 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2018-10-15 |
Time |
14:30 |
Sent To |
B |
|
Notes |
2018-10-15 14:30:38 | THIS IS A PHOTOVOLTAIC AND HAS NO PLUMBING. TKL. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2018-11-01 |
|
|
Cont ID |
|
Sent By |
hmtribou |
Date |
2018-11-01 |
Time |
10:43 |
Rev Time |
0.00 |
Received By |
hmtribou |
Date |
2018-11-01 |
Time |
10:43 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2018-10-05 |
|
|
Cont ID |
|
Sent By |
hmtribou |
Date |
2018-10-05 |
Time |
08:23 |
Rev Time |
0.00 |
Received By |
hmtribou |
Date |
2018-10-05 |
Time |
08:23 |
Sent To |
P |
|
Notes |
2018-10-05 08:28:38 | SOLAR PANELS MAY NOT EXTEND PAST ROOF LINE. IT APPEARS | | THAT THE SOUTH EAST CORNER OF THE SOLAR PANEL EXTENDS | | PAST AN EAVE LINE. IF ALL WAS SHIFTED TO THE WEST, THEN | | THE PANELS WILL EXTEND PAST THE WEST SIDE OF THE ROOF | | LINE. |
|
|