Plan Review Details - Permit 18091284
Plan Review Stops For Permit 18091284
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2019-10-23 Cont ID  
Sent By dbattles Date 2019-10-23 Time 08:41 Rev Time 0.00
Received By dbattles Date 2019-10-22 Time 11:06 Sent To  
Notes
2019-10-23 08:33:13PROVISOS:
 1) DEFERRED SUBMITTALS - SEE SHEET G100 FOR FULL LIST
 OF DEFERRED SUBMITTALS
 2) MODIFIED BITUMEN 17-1221.10 - FLAT ROOF PENDING
 SELECTING SYSTEM
 PROVIDE ENGINEERING IF APPLICABLE BASED ON FLAT ROOF
 SYSTEM SELECTION.
 3) CONSTRUCTION HOURS - 7AM TO 7PM MON-FRI, 8AM TO 8PM
 SAT-SUN
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2019-09-24 Cont ID  
Sent By jwitmer Date 2019-09-24 Time 15:11 Rev Time 0.00
Received By jwitmer Date 2019-09-24 Time 09:38 Sent To  
Notes
2019-09-24 15:11:472017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 18091284
 ADD: 2201 45TH ST. JFK NORTH ED ADDITION & RENOVATIONS
 CONT: DPR CONSTRUCTION
 TEL: 954-991-6200
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 3RD REVIEW
 DATE: TUES. SEPT. 24/2019
 ACTION: DENIED
  
 1) 3RD REQUEST. THIS PROJECT WILL REQUIRE A RESIDENT
 INSPECTOR ON THE PROJECT AS LONG AS THERE IS STRUCTURAL
 STEEL BOLTED OR WELDED CONNECTIONS BAR JOIST AND THE
 STEEL ROOF DECK ANCHORING BY WELDS OR BOLTED
 CONNECTIONS.
 2017 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION 110.3.9. OTHER
 INSPECTIONS SERVICES. THE BUILDING OFFICIAL MAY MAKE,
 OR CAUSE TO BE MADE BY OTHERS, THE INSPECTIONS REQUIRED
 BY SECTION 109 110. HE/SHE MAY ACCEPT REPORTS OF
 INSPECTORS OF RECOGNIZED INSPECTION SERVICES, PROVIDED
 THAT AFTER INVESTIGATION HE/SHE IS SATISFIED AS TO
 THEIR QUALIFICATIONS AND RELIABILITY. A CERTIFICATE
 CALLED FOR BY ANY PROVISION OF THE TECHNICAL CODES
 SHALL NOT BE BASED ON SUCH REPORTS UNLESS THE SAME ARE
 IN WRITING AND CERTIFIED BY A RESPONSIBLE OFFICER OF
 SUCH SERVICE. THE BUILDING OFFICIAL MAY REQUIRE THE
 OWNER TO EMPLOY AN INSPECTION SERVICE IN THE FOLLOWING
 INSTANCES:
 1. FOR BUILDINGS OR ADDITIONS OF TYPE I OR II
 CONSTRUCTION
 2. FOR ALL MAJOR STRUCTURAL ALTERATIONS
 FORMS ARE TO BE E-MAILED TO : [email protected] SENT AT
 2:09 PM 02/19/2019.
  
 2) TO BE DETERMINED BY THE BUILDING OFFICIAL, TO DATE
 NO RESPONSE BACK AS TO THE DETERMINATION OF EXPOSURE B
 OR C. SHEET 088_S001 IN THE STRUCTURAL NOTES IN THE
 WIND DESIGN DATA THE EXPOSURE IS GIVEN AS A B EXPOSURE.
 IT WOULD APPEAR THAT TO THE NORTHEAST AND NORTHWEST
 THERE ARE C EXPOSURES SINCE MOST OF THESE AREAS HAVE
 LITTLE OR NO BUILDINGS, THEY ARE GRASSLANDS, OPEN
 LAKES, CANALS, PARKING LOTS AND HIGHWAYS.
 2017 FBC-B 1609.4.2 SURFACE ROUGHNESS CATEGORIES. A
 GROUND SURFACE ROUGHNESS WITHIN EACH 45-DEGREE SECTOR
 SHALL BE DETERMINED FOR A DISTANCE UPWIND OF THE SITE
 AS DEFINED IN SECTION 1609.4.3 FROM THE CATEGORIES
 DEFINED BELOW, FOR THE PURPOSE OF ASSIGNING AN EXPOSURE
 CATEGORY AS DEFINED IN SECTION 1609.4.3.
 SURFACE ROUGHNESS C. OPEN TERRAIN WITH SCATTERED
 OBSTRUCTIONS HAVING HEIGHTS GENERALLY LESS THAN 30
 FEET. THIS CATEGORY INCLUDES FLAT OPEN COUNTRY, AND
 GRASSLANDS.
  
 3) PENDING THE BUILDING OFFICIALS DETERMINATION. SINCE
 THE EXPOSURE WOULD BE A C EXPOSURE FOR 179 VASD THE
 PRESSURES WILL INCREASE FOR THE MULTIPLIER FOR THE
 HEIGHT OF THE BUILDING FOR THE EXPOSURE C. SEE TABLE
 1609.7(2).
  
 4) COLMPIED. PENDING EXPOSURE CATEGORY B IF C PRESSURES
 WILL BE HIGHER.
 THE COLUMN OF PRESSURES FOR CORNERS WALL ZONE 5 THE
 NEGATIVE PRESSURES FOR 20 SQ. FT. AND 100 SQ. FT. ARE
 THE SAME AND THE PRESSURES FOR 50 SQ. FT. ARE HIGHER
 THAN FOR THE 20 SQ. FT. IT WOULD APPEAR THIS IS A TYPO,
 PLEASE PROVIDE ADDITIONAL INFORMATION, PLEASE.
 107.2.1.2. ADDITIONAL INFORMATION IS REQUIRED.
  
 5A) 3RD REVIEW. SEMI- COMPLIED. PRODUCT APPROVALS WERE
 SUBMITTED BUT THE OTHER COMMENTS THAT DEAL WITH THE
 PRODUCT APPROVAL HAVE NOT BEEN ADDRESSED. STATING THE
 SPECS DOES NOT CONSTITUTE CODE COMPLIANCE. 2017 FBC-B
 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.4.1
 COMPONENTS & CLADDING. FLORIDA DEPARTMENT OF COMMUNITY
 AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, RULE 9N-3
 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR
 CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT
 APPROVALS:
 (31)(A) EXTERIOR DOORS, MULLIONS & ROOF HATCHES.
 (B) WINDOWS & MULLIONS
 (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL
 LOUVERS, EFIS SYSTEMS,
 (D) ROOFING PRODUCTS AND ASSEMBLIES, LIGHTWEIGHT
 CONCRETE INSULATION, ROOF TOP VENTILATORS & CURBS
  
 5B) 3RD REQUEST. WE STILL HAVE NOT SEEN WHERE THE
 DESIGNER OF RECORD HAS REVIEWED AND APPROVED THE
 INSTALLATION OF THESE PRODUCT ON THIS PROJECT WITH
 THEIR SHOP DRAWING STAMP OF APPROVAL, OR LISTED ON AN
 ARCHITECTURAL SHEET. W. P. B. 107.3.4. PRODUCT
 APPROVALS. THOSE PRODUCTS WHICH ARE REGULATED BY
 FLORIDA ADMINISTRATIVE CODE RULE 61G20 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 6) 3RD REQUEST. IN REVIEWING ALL OF THE PRODUCT
 APPROVALS WITH GLAZED UNITS AND OR MULLIONS, NONE HAVE
 BEEN IDENTIFIED.
 1ST REVIEW COMMENT. IDENTIFY GLAZING/ MULLIONS. PLEASE
 IDENTIFY ON THE PRODUCT APPROVAL BEFORE SUBMITTING TO
 DESIGNER OF RECORD AND BEFORE SUBMISSION TO THE
 BUILDING DEPARTMENT. FOR ALL PRODUCTS WITH GLAZING,
 PLEASE IDENTIFY THE OPENING WIDTH & HEIGHT, TYPE OF
 GLAZING, MULLION SIZE, LENGTH IF UNREINFORCED OR
 REINFORCED INFORMATION IF REQUIRED, ATTACHMENTS AND
 ASSOCIATE PRESSURES FOR EACH OPENING SIZE. 2014 FBC-B
 1405.13.1 INSTALLATION. WINDOWS AND DOORS SHALL BE
 INSTALLED IN ACCORDANCE WITH APPROVED MANUFACTURERS
 INSTRUCTIONS. FASTENER SIZE AND SPACING SHALL BE
 PROVIDED IN SUCH INSTRUCTIONS AND SHALL BE CALCULATED
 BASED ON MAXIMUM LOADS AND SPACING USED IN THE TESTS.
  
 7) 3RD ***REVIEW LIGHTWEIGHT CONCRETE NOA 18-0208-03
 PLEASE NOTE THERE ARE SUBSTRATE REQUIREMENTS WITHIN
 THIS PRODUCT APPROVAL THAT EITHER THE CONTRACTOR OR
 DESIGNER OF RECORD PICK OUT PAGES 8-11 CIRCLE THE DECK
 TYPE TO BE INSTALLED NOTE THE PRESSURES FOR THE STEEL
 DECK ARE MAXIMUM DESIGN PRESSURES, NO ENHANCEMENT.
 3RD REVIEW. NOA 17-0808.06 BERRIDGE MANUFACTURING
 ZEE-LOCK PANEL & CLIP. PLEASE NOTE THERE ARE VARIOUS
 DECKS AND DESIGN PRESSURES, PLEASE IDENTIFY THE TYPE OF
 DECK TO BE INSTALLED. THERE IS STILL A QUESTION AS TO
 THE SHEATHING TO BE APPLIED TO THE B DECK, SHEET
 063_A501 DOES SHOW DENSGLASS AS THE ROOF SHEATHING BUT
 NO PRODUCT APPROVAL HAS BEEN REVIEWED AND SUBMITTED.
 PLEASE NOTE THIS IS A REPETITIVE COMMENT FOR ALL OF THE
 PRODUCT APPROVALS.
 1ST REVIEW COMMENT. ROOFING: FOR ALL ROOFING PRODUCTS
 PLEASE IDENTIFY ALL ROOFING SUB-SYSTEMS AND THEIR
 ASSOCIATED PRESSURES FOR ROOF ZONE # 1. REVIEW THE
 PRODUCT APPROVAL LIMITATIONS, IF ENHANCED FASTENING IS
 ALLOWED FOR ROOF ZONES 2 & 3. FASTENER DENSITIES SHALL
 BE INCREASED FOR BOTH INSULATION & THE BASE SHEET AS
 CALCULATED IN COMPLIANCE WITH ROOFING APPLICATION
 STANDARDS RAS 117. CALCULATION PREPARED, SIGNED AND
 SEALED BY A FLORIDA REGISTERED PROFESSIONAL ENGINEER OR
 REGISTERED ARCHITECT. 1609.6.4.4.1 COMPONENTS &
 CLADDING.
  
 8) 3RD REQUEST. SEMI-COMPLIED. THE SUBMITTED STO NOA
 16-0418 HAS 3 BASE SHEATHING PRODUCTS WITHIN THIS NOA
 PLEASE CIRCLE AND IDENTIFY WHICH OF THESE PRODUCT AND
 ASSOCIATED PRESSURES WILL BE INSTALLED AS THE BASE.
 EFIS SYSTEMS: PLEASE PROVIDE THE PRODUCT APPROVAL FOR
 THE SYSTEM TO BE INSTALLED. PLEASE ALSO PROVIDE THE
 MANUFACTURERS INSTALLATION BROCHURE PROVIDING
 COMPLIANCE WITH 2014 FBC-B SECTIONS;
 1408.2 PERFORMANCE CHARACTERISTICS.
 1408.2 PERFORMANCE CHARACTERISTICS.
 1408.3 STRUCTURAL DESIGN.
 1408.4 WEATHER RESISTANCE.
 1408.4.1 EIFS WITH DRAINAGE.
 408.4.1.1 WATER-RESISTIVE BARRIER.
 1408.5 INSTALLATION
  
 9) 3RD REVIEW. PLEASE NOTE THAT SINCE THE SUBMITTED
 PRODUCT APPROVALS HAVE HAD COMMENTS AND PLAN REVIEW
 TIME ON THE SUBMITTED APPROVALS IF AFTER PERMIT
 ISSUANCE THEY ARE CHANGED TO A DIFFERENT PRODUCT THAT
 WILL CONSTITUTE A REVISION. EACH PRODUCT APPROVAL THAT
 IS CHANGED IS CONSIDERED A SEPARATE REVISION, WITH
 ASSOCIATE REVIEW AND FEES.
 IF EITHER THE CONTRACTOR OR DESIGN PROFESSIONAL WOULD
 LIKE TO SUBMIT THE PRODUCT APPROVALS AFTER PERMIT
 ISSUANCE PLEASE NOTE SO ON THE PLANS AS A DEFERRED
 SUBMITTAL.
  
 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS
 SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE
 PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE
 TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO
 THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD.
 DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR
 APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED
 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST
 THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS
 FOR REVIEW BY THE BUILDING OFFICIAL.
  
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.
  
 10) 3RD REVIEW. SHEET 088_S001 UNDER THE HEADING OF
 FOUNDATION AND THE GEOTECHNICAL REPORT IT DOES NOT
 INDICATE A REPORT NUMBER NOR UNDER THE SOIL BEARING
 CAPACITY FOR ISOLATED FOOTING OR CONTINUOUS FOOTING THE
 PSF IS LEFT BLANK. PLEASE SHOW COMPLIANCE WITH THE 2017
 FBC-B SECTION:
  
 1803.5.2 QUESTIONABLE SOIL. WHERE THE CLASSIFICATION,
 STRENGTH OR COMPRESSIBILITY OF THE SOIL IS IN DOUBT OR
 WHERE A LOAD-BEARING VALUE SUPERIOR TO THAT SPECIFIED
 IN THIS CODE IS CLAIMED, THE BUILDING OFFICIAL SHALL BE
 PERMITTED TO REQUIRE THAT A GEOTECHNICAL INVESTIGATION
 BE CONDUCTED.
  
 11 A-E) PROVISO: SEPARATE PERMITS FOR TEMPORARY
 AMBULANCE CANOPY, TEMPORARY ENCLOSED WALKWAY AND A 2ND
 TEMPORARY CANOPY FOR PUBLIC ED. AND A 2ND ENCLOSED
 WALKWAY WITH LIGHTS AND SPRINKLERS. ADDITIONAL
 INFORMATION IS REQUIRED? 107.2.1.2.
  
 11A) THE PLAN INDICATES THAT THE TEMPORARY WALKWAY HAS
 LIGHTS AND FIRE SPRINKLERS BUT NOT THE TEMP. AMBULANCE
 CANOPY, OR PUBLIC EDUCATION CANOPIES DO THEY HAVE
 LIGHTS AND FIRE SPRINKLERS AS WELL?
 2017 FBC-B 3103.1.1 CONFORMANCE. TEMPORARY STRUCTURES
 AND USES SHALL CONFORM TO THE STRUCTURAL STRENGTH, FIRE
 SAFETY, AND MEANS OF EGRESS, ACCESSIBILITY, LIGHT,
 VENTILATION AND SANITARY REQUIREMENTS OF THIS CODE AS
 NECESSARY TO ENSURE PUBLIC HEALTH, SAFETY AND GENERAL
 WELFARE.
  
 11B) IS THE TEMPORARY WALKWAYS AND AMBULANCE & PUBLIC
 EDUCATION CANOPIES GOING TO BE PART OF THIS PERMIT OR
 COME IN UNDER A SEPARATE TENT PERMIT. 107.2.1.2
 ADDITIONAL INFORMATION IS REQUIRED.
  
 11C) HOW LONG IS THE WALKWAYS, AMBULANCE CANOPY &
 PUBLIC EDUCATION CANOPIES GOING TO BE ERECTED?
 THE BUILDING CODE 2017 FBC-B SECTION:
 3103.1 THE PROVISIONS OF SECTIONS 3103.1 THROUGH 3103.4
 SHALL APPLY TO STRUCTURES ERECTED FOR A PERIOD OF LESS
 THAN 180 DAYS. TENTS AND OTHER MEMBRANE STRUCTURES
 ERECTED FOR A PERIOD OF LESS THAN 180 DAYS SHALL COMPLY
 WITH THE FLORIDA FIRE PREVENTION CODE. THOSE ERECTED
 FOR A LONGER PERIOD OF TIME SHALL COMPLY WITH
 APPLICABLE SECTIONS OF THIS CODE.
  
 THE AMBULANCE AND WALKWAY CANOPIES WILL NEED TO SHOW
 ENGINEERING FOR THE WIND SPEED REQUIRED FOR 180 VULT,
 OR WILL THE STRUCTURES BE REMOVED IN CASE OF
 HURRICANES, WHAT THEN WOULD HAPPEN TO THE FIRE
 SPRINKLER PIPING WITHIN THE STRUCTURES?
  
 11D) WITH THE EXTENSION OF THE EXIT SHOWN IN THE PLAN,
 IT IS NOT CLEAR IF THE ENCLOSED WALKWAY FOR THE
 AMBULANCE CANOPY ONLY HAS THE ONE EXIT AT THE END OF
 THE ENCLOSURE OR IF AT THE MAIN BUILDING EXIT THERE IS
 A SIDE OPENING TO ALLOW THE EXITING OF THE ENCLOSURE
 DIRECTLY FROM THE BUILDING?
 2017 FBC-B 3103.4 MEANS OF EGRESS. TEMPORARY STRUCTURES
 SHALL CONFORM TO THE MEANS OF EGRESS REQUIREMENTS OF
 CHAPTER 10 AND SHALL HAVE AN EXIT ACCESS TRAVEL
 DISTANCE OF 100 FEET (30 480 MM) OR LESS.
  
 11E) IN THE TENT FOR THE AMBULANCES ARE THEIR GOING TO
 HAVE SIDES ENCLOSING THE TENT AS THE WALKWAY, HOW WILL
 THE VENTILATION REQUIREMENTS BE MET AND CARBON MONOXIDE
 FROM THE AMBULANCES BE REMOVED FROM THE TENT.
 2017 FBC-B 3103.1.1 CONFORMANCE. TEMPORARY STRUCTURES
 AND USES SHALL CONFORM TO THE STRUCTURAL STRENGTH, FIRE
 SAFETY, AND MEANS OF EGRESS, ACCESSIBILITY, LIGHT,
 VENTILATION AND SANITARY REQUIREMENTS OF THIS CODE AS
 NECESSARY TO ENSURE PUBLIC HEALTH, SAFETY AND GENERAL
 WELFARE.
  
 12-16) COMPLIED.
 17) SEMI-COMPLIED. WITHIN THE STO PRODUCT APPROVAL
 THERE IS LISTED 3 TYPES OF GLASS MAT GYPSUM SUBSTRATE
 PRODUCT THAT ARE COVERED UNDER THIS NOA. PLEASE CIRCLE
 THE PRODUCT TO BE INSTALLED WITH ASSOCIATED PRESSURES.
 18) COMPLIED.
  
 19) SEMI-COMPLIED. SAME AS COMMENT # 17.
 1ST ROUND COMMENTS. SHEET 069_A577 THERE ARE 3 DETAILS
 DETAIL # 1 & 2 DOES NOT INDICATE THE TYPE OF SHEATHING
 TO BE INSTALLED. BOTH DETAIL 2 & 3 BOTH INDICATE SEE
 DETAIL # 4 SHEET 011_G165. 2 INCH EFIS ON 5/8 INCH
 EXTERIOR SHEATHING. PLEASE NOTE THE CONSTRUCTION TYPE
 FOR THIS BUILDING IS I-B. PLEASE REVIEW THE 2017 FBC-B
 SECTIONS:
  
 603.1 ALLOWABLE MATERIALS. COMBUSTIBLE MATERIALS SHALL
 BE PERMITTED IN BUILDINGS OF TYPE I OR II CONSTRUCTION
 IN THE FOLLOWING APPLICATIONS AND IN ACCORDANCE WITH
 SECTIONS 603.1.1 THROUGH 603.1.3:
 1.FIRE-RETARDANT-TREATED WOOD SHALL BE PERMITTED IN:
 1.1.NONBEARING PARTITIONS WHERE THE REQUIRED
 FIRE-RESISTANCE RATING IS 2 HOURS OR LESS.
 1.2.NONBEARING EXTERIOR WALLS WHERE
 FIRE-RESISTANCE-RATED CONSTRUCTION IS NOT REQUIRED.
 1.3.ROOF CONSTRUCTION, INCLUDING GIRDERS, TRUSSES,
 FRAMING AND DECKING.
  
 20-21) SEMI-COMPLIED. IN THE UPPER LEFT HAND CORNER THE
 TYPICAL CASEWORK DETAIL STILL SHOWS A MICROWAVE OVER
 THE UNOBSTRUCTED REACH RANGES.
 SHEET 076_A800 PLEASE REVIEW THE UPPER LEFT HAND BREAK
 ROOM CABINETS, DETAIL NOT GIVEN A DETAIL NUMBER. THE
 SHELF THAT THE MICROWAVE SITS ON IS 4 FOOT 8 INCHES
 ABOVE FINISH FLOOR, OUT OF REACH RANGES.
 SEE THE 2017 FBC-ACCESSIBILITY CODE SECTIONS:
  
 308 REACH RANGES. 308.2 FORWARD REACH./ 308.2.1
 UNOBSTRUCTED/ 308.2.2 OBSTRUCTED HIGH REACH.
 308.3 SIDE REACH. / 308.3.1 UNOBSTRUCTED/ 308.3.2
 OBSTRUCTED HIGH REACH.
  
 309 OPERABLE PARTS. 309.3 HEIGHT. OPERABLE PARTS SHALL
 BE PLACED WITHIN ONE OR MORE OF THE REACH RANGES
 SPECIFIED IN 308.309.4 OPERATION. OPERABLE PARTS SHALL
 BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT
 GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE
 REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS
 (22.2 N) MAXIMUM.
 22-23) COMPLIED.
  
  
 24) IMPACT FEES - DIGITAL SUBMITTALS: PLANS WILL BE
 REVIEWED BY THE PBC IMPACT FEE OFFICE DIGITALLY VIA
 PROJECT DOX UPON NOTIFICATION BY THIS OFFICE.
 NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST FINAL
 FORM. YOU MAY COORDINATE WITH THE IMPACT FEE OFFICE AT
 (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL IMPACT
 FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME THE
 FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM CAN
 BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINISTRAT
 ION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO: [email protected]
 25) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2019-06-28 Cont ID  
Sent By dbattles Date 2019-06-28 Time 15:04 Rev Time 0.00
Received By dbattles Date 2019-06-27 Time 08:40 Sent To  
Notes
2019-06-28 15:11:092 ND REVIEW: JUNE 27, 2019
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER PX4191
 [email protected]
 561-805-6718
  
 2017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 18091284
 ADD: 2201 45TH ST. JFK NORTH ED ADDITION & RENOVATIONS
 CONT: DPR CONSTRUCTION
 TEL: 954-991-6200
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1) IN PROGRESS
 -PLEASE SEND RESIDENT INSPECTOR AGREEMENT (STARTS ON
 PAGE 9) VIA E-MAIL TO [email protected]. ALSO, INCLUDE
 RESUMES FOR ALL INSPECTORS THAT MAY BE ON-SITE.
 UPON APPROVAL BY CHIEF BUILDING INSPECTOR, THREE
 ORIGINAL COPIES WILL BE REQUESTED.
  
 2) SHEET 088_S001 IN THE STRUCTURAL NOTES IN THE WIND
 DESIGN DATA THE EXPOSURE IS GIVEN AS A B EXPOSURE. IT
 WOULD APPEAR THAT TO THE NORTHEAST AND NORTHWEST THERE
 ARE C EXPOSURES SINCE MOST OF THESE AREAS HAVE LITTLE
 OR NO BUILDINGS, THEY ARE GRASSLANDS, OPEN LAKES,
 CANALS, PARKING LOTS AND HIGHWAYS.
 2017 FBC-B 1609.4.2 SURFACE ROUGHNESS CATEGORIES. A
 GROUND SURFACE ROUGHNESS WITHIN EACH 45-DEGREE SECTOR
 SHALL BE DETERMINED FOR A DISTANCE UPWIND OF THE SITE
 AS DEFINED IN SECTION 1609.4.3 FROM THE CATEGORIES
 DEFINED BELOW, FOR THE PURPOSE OF ASSIGNING AN EXPOSURE
 CATEGORY AS DEFINED IN SECTION 1609.4.3.
 SURFACE ROUGHNESS C. OPEN TERRAIN WITH SCATTERED
 OBSTRUCTIONS HAVING HEIGHTS GENERALLY LESS THAN 30
 FEET. THIS CATEGORY INCLUDES FLAT OPEN COUNTRY, AND
 GRASSLANDS.
 -STRUCTURAL ENGINEER FEELS THAT THIS SHOULD BE EXPOSURE
 B.
 THIS HAS BEEN SENT TO THE BUILDING OFFICIAL FOR
 DETERMINATION.
  
 3) PENDING BUILDING OFFICIAL DETERMINATION.
  
 4) OK
  
 5A) PLEASE PROVIDE THE PRODUCT APPROVAL FOR STOREFRONT
 SYSTEM BEING USED AT WINDOWS, OR INDICATE THAT IT WILL
 BE DEFERRED.
  
 5B) W. P. B. 107.3.4. PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY FLORIDA ADMINISTRATIVE CODE RULE
 61G20 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
 PLEASE PROVIDE PRODUCT APPROVALS THAT HAVE BEEN STAMPED
 FOR APPROVAL BY THE DESIGNER OF RECORD, OR PROVIDE
 INDEX SHEET LISTING THE PRODUCT APPROVALS AND
 VERIFICATION THAT WERE REVIEWED.
  
 6) OK
  
 7) ROOFING PRODUCT APPROVALS ? PLEASE SELECT THE SYSTEM
 BEING USED FROM NOA 17-1221.10 AND PROVIDE INFORMATION
 IF REQUIRED BY GENERAL LIMITATIONS.
 IF INFORMATION IS NOT KNOWN THIS CAN BECOME A DEFERRED
 SUBMITTAL WITH THE SUB PERMIT.
  
 8) OK
  
 9) OK
  
 10) GEOTECHNICAL REPORT WAS NOT FOUND IN SUPPORTING
 DOCUMENTS. PLEASE UPLOAD GEOTECHNICAL REPORT, OR TELL
 ME WHERE IT IS LOCATED. IF IT IS COMBINED WITH ANOTHER
 DOCUMENT PLEASE PROVIDE AS STAND ALONE DOCUMENT.
  
 11) ADDITIONAL PERMIT IS BEING SUBMITTED FOR TEMP
 WALKWAYS AND FENCING. WALKWAYS TO BE DESIGNED BY P.E.
 AND DIGITALLY SIGNED WITH THIRD PARTY VERIFICATION.
 61G15-23 PE RULES FAC, FS 471 ENGINEERING FS.
  
 12) OK
  
 13) OK
  
 14) ROOF HATCH PRODUCT APPROVAL WAS SUBMITTED
 PREVIOUSLY.
 IS THIS BEING USED, OR IS ACCESS PROVIDED BY EXTERIOR
 LADDER?
 PLEASE DELETE ROOF HATCH FROM SUPPORTING DOCUMENTS IF
 NOT UTILIZING.
 ACCESS LADDER TO BE ADDED TO PROVISO LIST TO PROVIDE
 LOCATION AND ATTACHMENT.
  
 15) OK
  
 16A) ROOFTOP EXHAUST FANS WILL BE ADDED TO DEFERRED
 SUBMITTAL LIST.
 NO RESPONSE NEEDED.
  
 16B)-22 OK
  
 23) PLEASE SUPPLY A SURVEY FOR THIS PROPERTY INDICATING
 THE DISTANCE FROM THE CURRENT BUILDING LOCATION TO THE
 EAST PROPERTY LINE TO VERIFY THE EXTERIOR WALL RATING
 FBC-B TABLE 602 AND THE AMOUNT OF ALLOWABLE OPENINGS
 FOR UNPROTECTED AND SPRINKLERED FBC-B TABLE 705.8.
 I COULD NOT FIND THE SURVEY IN DRAWINGS OR SUPPORTING
 DOCUMENTS.
 PLEASE UPLOAD THE EXISTING SURVEY.
  
 24) OK
  
 25) OK
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-02-21 Cont ID  
Sent By jwitmer Date 2019-02-21 Time 07:00 Rev Time 0.00
Received By jwitmer Date 2019-02-12 Time 14:17 Sent To  
Notes
2019-02-21 07:00:362017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 18091284
 ADD: 2201 45TH ST. JFK NORTH ED ADDITION & RENOVATIONS
 CONT: DPR CONSTRUCTION
 TEL: 954-991-6200
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. FEB. 20/2019
 ACTION: DENIED
  
 1) THIS PROJECT WILL REQUIRE A RESIDENT INSPECTOR ON
 THE PROJECT AS LONG AS THERE IS STRUCTURAL STEEL BOLTED
 OR WELDED CONNECTIONS BAR JOIST AND THE STEEL ROOF DECK
 ANCHORING BY WELDS OR BOLTED CONNECTIONS.
 2017 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION 110.3.9. OTHER
 INSPECTIONS SERVICES. THE BUILDING OFFICIAL MAY MAKE,
 OR CAUSE TO BE MADE BY OTHERS, THE INSPECTIONS REQUIRED
 BY SECTION 109 110. HE/SHE MAY ACCEPT REPORTS OF
 INSPECTORS OF RECOGNIZED INSPECTION SERVICES, PROVIDED
 THAT AFTER INVESTIGATION HE/SHE IS SATISFIED AS TO
 THEIR QUALIFICATIONS AND RELIABILITY. A CERTIFICATE
 CALLED FOR BY ANY PROVISION OF THE TECHNICAL CODES
 SHALL NOT BE BASED ON SUCH REPORTS UNLESS THE SAME ARE
 IN WRITING AND CERTIFIED BY A RESPONSIBLE OFFICER OF
 SUCH SERVICE. THE BUILDING OFFICIAL MAY REQUIRE THE
 OWNER TO EMPLOY AN INSPECTION SERVICE IN THE FOLLOWING
 INSTANCES:
 1. FOR BUILDINGS OR ADDITIONS OF TYPE I OR II
 CONSTRUCTION
 2. FOR ALL MAJOR STRUCTURAL ALTERATIONS
 FORMS ARE TO BE E-MAILED TO : [email protected] SENT AT
 2:09 PM 02/19/2019.
  
 2) SHEET 088_S001 IN THE STRUCTURAL NOTES IN THE WIND
 DESIGN DATA THE EXPOSURE IS GIVEN AS A B EXPOSURE. IT
 WOULD APPEAR THAT TO THE NORTHEAST AND NORTHWEST THERE
 ARE C EXPOSURES SINCE MOST OF THESE AREAS HAVE LITTLE
 OR NO BUILDINGS, THEY ARE GRASSLANDS, OPEN LAKES,
 CANALS, PARKING LOTS AND HIGHWAYS.
 2017 FBC-B 1609.4.2 SURFACE ROUGHNESS CATEGORIES. A
 GROUND SURFACE ROUGHNESS WITHIN EACH 45-DEGREE SECTOR
 SHALL BE DETERMINED FOR A DISTANCE UPWIND OF THE SITE
 AS DEFINED IN SECTION 1609.4.3 FROM THE CATEGORIES
 DEFINED BELOW, FOR THE PURPOSE OF ASSIGNING AN EXPOSURE
 CATEGORY AS DEFINED IN SECTION 1609.4.3.
 SURFACE ROUGHNESS C. OPEN TERRAIN WITH SCATTERED
 OBSTRUCTIONS HAVING HEIGHTS GENERALLY LESS THAN 30
 FEET. THIS CATEGORY INCLUDES FLAT OPEN COUNTRY, AND
 GRASSLANDS.
  
 3) SINCE THE EXPOSURE WOULD BE A C EXPOSURE FOR 179
 VASD THE PRESSURES WILL INCREASE FOR THE MULTIPLIER FOR
 THE HEIGHT OF THE BUILDING FOR THE EXPOSURE C. SEE
 TABLE 1609.7(2).
  
 4) PLEASE ALSO NOTE ON SHEET 088_S001 UNDER THE HEADING
 2.4.1 EXTERIOR COMPONENTS & CLADDING
 THE COLUMN OF PRESSURES FOR CORNERS WALL ZONE 5 THE
 NEGATIVE PRESSURES FOR 20 SQ. FT. AND 100 SQ. FT. ARE
 THE SAME AND THE PRESSURES FOR 50 SQ. FT. ARE HIGHER
 THAN FOR THE 20 SQ. FT. IT WOULD APPEAR THIS IS A TYPO,
 PLEASE PROVIDE ADDITIONAL INFORMATION, PLEASE.
 107.2.1.2. ADDITIONAL INFORMATION IS REQUIRED.
  
 5A) 2017 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT
 OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005,
 RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS
 OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT
 APPROVALS:
 (31)(A) EXTERIOR DOORS, MULLIONS & ROOF HATCHES.
 (B) WINDOWS & MULLIONS
 (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL
 LOUVERS, EFIS SYSTEMS,
 (D) ROOFING PRODUCTS AND ASSEMBLIES, LIGHTWEIGHT
 CONCRETE INSULATION, ROOF TOP VENTILATORS & CURBS
  
 5B) W. P. B. 107.3.4. PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY FLORIDA ADMINISTRATIVE CODE RULE
 61G20 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 6) IDENTIFY GLAZING/ MULLIONS. PLEASE IDENTIFY ON THE
 PRODUCT APPROVAL BEFORE SUBMITTING TO DESIGNER OF
 RECORD AND BEFORE SUBMISSION TO THE BUILDING
 DEPARTMENT. FOR ALL PRODUCTS WITH GLAZING, PLEASE
 IDENTIFY THE OPENING WIDTH & HEIGHT, TYPE OF GLAZING,
 MULLION SIZE, LENGTH IF UNREINFORCED OR REINFORCED
 INFORMATION IF REQUIRED, ATTACHMENTS AND ASSOCIATE
 PRESSURES FOR EACH OPENING SIZE. 2014 FBC-B 1405.13.1
 INSTALLATION. WINDOWS AND DOORS SHALL BE INSTALLED IN
 ACCORDANCE WITH APPROVED MANUFACTURER?S INSTRUCTIONS.
 FASTENER SIZE AND SPACING SHALL BE PROVIDED IN SUCH
 INSTRUCTIONS AND SHALL BE CALCULATED BASED ON MAXIMUM
 LOADS AND SPACING USED IN THE TESTS.
  
 7) ROOFING: FOR ALL ROOFING PRODUCTS PLEASE IDENTIFY
 ALL ROOFING SUB-SYSTEMS AND THEIR ASSOCIATED PRESSURES
 FOR ROOF ZONE # 1. REVIEW THE PRODUCT APPROVAL
 LIMITATIONS, IF ENHANCED FASTENING IS ALLOWED FOR ROOF
 ZONES 2 & 3. FASTENER DENSITIES SHALL BE INCREASED FOR
 BOTH INSULATION & THE BASE SHEET AS CALCULATED IN
 COMPLIANCE WITH ROOFING APPLICATION STANDARDS RAS 117.
 CALCULATION PREPARED, SIGNED AND
 SEALED BY A FLORIDA REGISTERED PROFESSIONAL ENGINEER OR
 REGISTERED ARCHITECT. 1609.6.4.4.1 COMPONENTS &
 CLADDING.
  
 8) EFIS SYSTEMS: PLEASE PROVIDE THE PRODUCT APPROVAL
 FOR THE SYSTEM TO BE INSTALLED. PLEASE ALSO PROVIDE THE
 MANUFACTURERS INSTALLATION BROCHURE PROVIDING
 COMPLIANCE WITH 2014 FBC-B SECTIONS;
 1408.2 PERFORMANCE CHARACTERISTICS.
 1408.2 PERFORMANCE CHARACTERISTICS.
 1408.3 STRUCTURAL DESIGN.
 1408.4 WEATHER RESISTANCE.
 1408.4.1 EIFS WITH DRAINAGE.
 408.4.1.1 WATER-RESISTIVE BARRIER.
 1408.5 INSTALLATION
  
 9) IF EITHER THE CONTRACTOR OR DESIGN PROFESSIONAL
 WOULD LIKE TO SUBMIT THE PRODUCT APPROVALS AFTER PERMIT
 ISSUANCE PLEASE NOTE SO ON THE PLANS AS A DEFERRED
 SUBMITTAL.
  
 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS
 SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE
 PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE
 TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO
 THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD.
 DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR
 APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED
 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST
 THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS
 FOR REVIEW BY THE BUILDING OFFICIAL.
  
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.
  
 10) SHEET 088_S001 UNDER THE HEADING OF FOUNDATION AND
 THE GEOTECHNICAL REPORT IT DOES NOT INDICATE A REPORT
 NUMBER NOR UNDER THE SOIL BEARING CAPACITY FOR ISOLATED
 FOOTING OR CONTINUOUS FOOTING THE PSF IS LEFT BLANK.
 PLEASE SHOW COMPLIANCE WITH THE 2017 FBC-B SECTION:
  
 1803.5.2 QUESTIONABLE SOIL. WHERE THE CLASSIFICATION,
 STRENGTH OR COMPRESSIBILITY OF THE SOIL IS IN DOUBT OR
 WHERE A LOAD-BEARING VALUE SUPERIOR TO THAT SPECIFIED
 IN THIS CODE IS CLAIMED, THE BUILDING OFFICIAL SHALL BE
 PERMITTED TO REQUIRE THAT A GEOTECHNICAL INVESTIGATION
 BE CONDUCTED.
  
 11) SHEET 018G410 THE 1ST FLOOR PHASING PLAN WHICH
 INCLUDES A TEMPORARY AMBULANCE CANOPY, TEMPORARY
 ENCLOSED WALKWAY AND A 2ND TEMPORARY CANOPY FOR PUBLIC
 ED. AND A 2ND ENCLOSED WALKWAY WITH LIGHTS AND
 SPRINKLERS. ADDITIONAL INFORMATION IS REQUIRED?
 107.2.1.2.
  
 11A) THE PLAN INDICATES THAT THE TEMPORARY WALKWAY HAS
 LIGHTS AND FIRE SPRINKLERS BUT NOT THE TEMP. AMBULANCE
 CANOPY, OR PUBLIC EDUCATION CANOPIES DO THEY HAVE
 LIGHTS AND FIRE SPRINKLERS AS WELL?
 2017 FBC-B 3103.1.1 CONFORMANCE. TEMPORARY STRUCTURES
 AND USES SHALL CONFORM TO THE STRUCTURAL STRENGTH, FIRE
 SAFETY, AND MEANS OF EGRESS, ACCESSIBILITY, LIGHT,
 VENTILATION AND SANITARY REQUIREMENTS OF THIS CODE AS
 NECESSARY TO ENSURE PUBLIC HEALTH, SAFETY AND GENERAL
 WELFARE.
  
 11B) IS THE TEMPORARY WALKWAYS AND AMBULANCE & PUBLIC
 EDUCATION CANOPIES GOING TO BE PART OF THIS PERMIT OR
 COME IN UNDER A SEPARATE TENT PERMIT. 107.2.1.2
 ADDITIONAL INFORMATION IS REQUIRED.
  
 11C) HOW LONG IS THE WALKWAYS, AMBULANCE CANOPY &
 PUBLIC EDUCATION CANOPIES GOING TO BE ERECTED?
 THE BUILDING CODE 2017 FBC-B SECTION:
 3103.1 THE PROVISIONS OF SECTIONS 3103.1 THROUGH 3103.4
 SHALL APPLY TO STRUCTURES ERECTED FOR A PERIOD OF LESS
 THAN 180 DAYS. TENTS AND OTHER MEMBRANE STRUCTURES
 ERECTED FOR A PERIOD OF LESS THAN 180 DAYS SHALL COMPLY
 WITH THE FLORIDA FIRE PREVENTION CODE. THOSE ERECTED
 FOR A LONGER PERIOD OF TIME SHALL COMPLY WITH
 APPLICABLE SECTIONS OF THIS CODE.
  
 THE AMBULANCE AND WALKWAY CANOPIES WILL NEED TO SHOW
 ENGINEERING FOR THE WIND SPEED REQUIRED FOR 180 VULT,
 OR WILL THE STRUCTURES BE REMOVED IN CASE OF
 HURRICANES, WHAT THEN WOULD HAPPEN TO THE FIRE
 SPRINKLER PIPING WITHIN THE STRUCTURES?
  
 11D) WITH THE EXTENSION OF THE EXIT SHOWN IN THE PLAN,
 IT IS NOT CLEAR IF THE ENCLOSED WALKWAY FOR THE
 AMBULANCE CANOPY ONLY HAS THE ONE EXIT AT THE END OF
 THE ENCLOSURE OR IF AT THE MAIN BUILDING EXIT THERE IS
 A SIDE OPENING TO ALLOW THE EXITING OF THE ENCLOSURE
 DIRECTLY FROM THE BUILDING?
 2017 FBC-B 3103.4 MEANS OF EGRESS. TEMPORARY STRUCTURES
 SHALL CONFORM TO THE MEANS OF EGRESS REQUIREMENTS OF
 CHAPTER 10 AND SHALL HAVE AN EXIT ACCESS TRAVEL
 DISTANCE OF 100 FEET (30 480 MM) OR LESS.
  
 11E) IN THE TENT FOR THE AMBULANCES ARE THEIR GOING TO
 HAVE SIDES ENCLOSING THE TENT AS THE WALKWAY, HOW WILL
 THE VENTILATION REQUIREMENTS BE MET AND CARBON MONOXIDE
 FROM THE AMBULANCES BE REMOVED FROM THE TENT.
 2017 FBC-B 3103.1.1 CONFORMANCE. TEMPORARY STRUCTURES
 AND USES SHALL CONFORM TO THE STRUCTURAL STRENGTH, FIRE
 SAFETY, AND MEANS OF EGRESS, ACCESSIBILITY, LIGHT,
 VENTILATION AND SANITARY REQUIREMENTS OF THIS CODE AS
 NECESSARY TO ENSURE PUBLIC HEALTH, SAFETY AND GENERAL
 WELFARE.
  
 12) SHEET 019G411 UNDER THE HEADING PHASING NOTE S NOTE
 # 6 STATES THAT DURING CONSTRUCTION AT NO TIME SHALL
 TEMPORARY CONSTRUCTION BARRIERS LIMIT THE CORRIDOR
 WIDTH TO LESS THAN 6 FEET. THERE IS NOTE ON THE PLANS
 FOR A TEMPORARY CORRIDOR TO BE 5 FEET 11 57/64 INCHES
 IN WIDTH. WHICH NOTE TAKES PRECEDENCE? THE NOTE IS
 LOCATED IN A CORRIDOR BETWEEN THE CLEAN SUPPLY ROOM AND
 PATIENT TOILET. 107.2.1.2 ADDITIONAL INFORMATION
 REQUIRED.
  
 13) SHEET 053_A250 DETAIL # 10 SHOWS A 1 HOUR
 HORIZONTAL SHAFT THAT IS HANGING FROM THE CEILING. THIS
 SAME DETAIL INDICATES SEE SHEET G150 DETAIL 7Z FOR THE
 1 HOUR SHAFT ENCLOSURE/ UL# U415. THE UL LISTING U 415
 DOES SHOW THE USE OF SHAFTWALL SYSTEM FOR NONBEARING
 WALL SYSTEMS. NOWHERE IN THE UL 415 STANDARD DOES IT
 STATE THAT THIS SHAFT WALL IS TO BE HUNG FROM THE
 CEILING. THE SHAFTWALL SYSTEM SHOWS THAT IT WAS ONLY
 TESTED FOR VERTICAL USE, (A WALL SYSTEM), IT DOES NOT
 INDICATE THAT THE SYSTEM WAS EVER TESTED FOR THE WALL
 ASSEMBLY TO BE TURNED ON ITS SIDE AND BE USED
 HORIZONTALLY. WE WILL NEED TO SEE ACTUAL TEST DATA FROM
 UL WHERE THIS ASSEMBLY WAS TESTED HANGING FROM THE
 CEILING, AND TESTED FROM BOTH SIDES SINCE THIS IS
 SHAFTWALL CONSTRUCTION WITH DIFFERENT COMPONENTS MAKING
 UP THE WALL SYSTEM.
  
 2017 FBC-B 707.5 CONTINUITY. FIRE BARRIERS SHALL EXTEND
 FROM THE TOP OF THE FOUNDATION OR FLOOR/CEILING
 ASSEMBLY BELOW TO THE UNDERSIDE OF THE FLOOR OR ROOF
 SHEATHING, SLAB OR DECK ABOVE AND SHALL BE SECURELY
 ATTACHED THERETO. SUCH FIRE BARRIERS SHALL BE
 CONTINUOUS THROUGH CONCEALED SPACE, SUCH AS THE SPACE
 ABOVE A SUSPENDED CEILING. JOINTS AND VOIDS AT
 INTERSECTIONS SHALL COMPLY WITH SECTIONS 707.8 AND
 707.9.
  
 14) THE SHEET 054_A300 AND 117_M301 BOTH SHOW A
 MECHANICAL PENTHOUSE. PLEASE INDICATE HOW ONE GETS UP
 TO THE PENTHOUSE TO WORK ON THE MECHANICAL EQUIPMENT.
 PLEASE SHOW COMPLIANCE WITH THE 2017
 FBC-B SECTIONS:
 1011.12 STAIRWAY TO ROOF. EXCEPTION: OTHER THAN WHERE
 REQUIRED BY SECTION 1011.12.1, IN BUILDINGS WITHOUT AN
 OCCUPIED ROOF ACCESS TO THE ROOF FROM THE TOP STORY
 SHALL BE PERMITTED TO BE BY AN ALTERNATING TREAD
 DEVICE, A SHIPS LADDER OR A PERMANENT LADDER.
  
 1011.12.2 ROOF ACCESS. WHERE A STAIRWAY IS PROVIDED TO
 A ROOF, ACCESS TO THE ROOF SHALL BE PROVIDED THROUGH A
 PENTHOUSE COMPLYING WITH SECTION 1510.2.
 EXCEPTION: IN BUILDINGS WITHOUT AN OCCUPIED ROOF,
 ACCESS TO THE ROOF SHALL BE PERMITTED TO BE A ROOF
 HATCH OR TRAP DOOR NOT LESS THAN 16 SQUARE FEET IN AREA
 AND HAVING A MINIMUM DIMENSION OF 2 FEET.
  
 1011.16 LADDERS. PERMANENT LADDERS SHALL NOT SERVE AS A
 PART OF THE MEANS OF EGRESS FROM OCCUPIED SPACES WITHIN
 A BUILDING. PERMANENT LADDERS SHALL BE PERMITTED TO
 PROVIDE ACCESS TO THE FOLLOWING AREAS:
 1.SPACES FREQUENTED ONLY BY PERSONNEL FOR MAINTENANCE,
 REPAIR OR MONITORING OF EQUIPMENT.
 5.NONOCCUPIED ROOFS THAT ARE NOT REQUIRED TO HAVE
 STAIRWAY ACCESS IN ACCORDANCE WITH SECTION
 1011.12.1.
 6.LADDERS SHALL BE CONSTRUCTED IN ACCORDANCE WITH
 SECTION 306.5 OF THE FLORIDA BUILDING CODE,
 MECHANICAL.
  
 15) SHEET 054_A300 ROOF PLAN NOTE 10. STATES THAT ROOF
 PAVERS OR BUILT UP WALKWAYS TO BE PROVIDED AND
 INSTALLED AS NEEDED TO ACCESS MECHANICAL EQUIPMENT FROM
 ROOF HATCHES. PLEASE SPECIFY EITHER ROOF PAVERS OR
 BUILT UP WALKWAYS.
 2017 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION 107.2.1.
 W.P.B. ADMINISTRATIVE CODE 2017. DRAWINGS &
 SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM
 OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS,
 WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE
 TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC TO
 THE TECHNICAL CODES "SHALL NOT BE CITED AS A WHOLE OR
 IN PART, NOR THE TERM "LEGAL" OR ITS EQUIVALENT BE USED
 AS A SUBSTITUTE FOR SPECIFIC INFORMATION".
  
 16A) THE ROOFTOP PLAN 054_A300 INDICATES NEW ROOF TOP
 EXHAUST FANS, THE MECHANICAL SHEET 121_M404 DETAIL 1
 &10 BOTH INDICATE EXHAUST FANS AND OR CURBS. NOTE 7 IN
 DETAIL 1 INDICATE FAN TO HAVE A NOA, PRODUCT APPROVAL.
 IN DETAIL 10 INDICATE AN ENGINEER IS TO PROVIDE THE
 ATTACHMENT METHOD OF THE FAN TO THE ROOF CURB AND CURB
 TO THE ROOF FRAMING. SHEET 101_S402 SHOW THE ROOF TOP
 REINFORCEMENT OF ROOF FRAMING AT THE ROOF DECK OPENING
 BUT NOT THE CURB TO THE ROOF FRAMING.
  
 LATERAL FORCE-RESISTING SYSTEM. FOR ALL ROOF TOP
 EQUIPMENT, CURBS, FANS OR A/C STANDS, AND OR VENTS,
 PIPE SUPPORTS ON THE ROOF DETAILED ATTACHMENT TO THE
 ROOF FRAMING & DECK AS WELL AS FROM THE CURB OR ROOF
 STAND TO THE EQUIPMENT ABOVE.
  
 2017 FBC-B 1604.4 ANALYSIS. LOAD EFFECTS ON STRUCTURAL
 MEMBERS AND THEIR CONNECTIONS SHALL BE DETERMINED BY
 METHODS OF STRUCTURAL ANALYSIS THAT TAKE INTO ACCOUNT
 EQUILIBRIUM, GENERAL STABILITY, GEOMETRIC COMPATIBILITY
 AND BOTH SHORT- AND LONG-TERM MATERIAL PROPERTIES.
 EVERY STRUCTURE SHALL BE DESIGNED TO RESIST THE
 OVERTURNING EFFECTS CAUSED BY THE LATERAL FORCES
 SPECIFIED IN THIS CHAPTER. SEE SECTION 1609 FOR WIND
 LOADS.
  
 16B) SHEET 121_M404 DETAIL 11 SHOWS A ROOF TOP PIPE
 SUPPORT. THE NOTE ON THE PLANS INDICATES THE TIE DOWN
 DETAILS ARE BY THE STRUCTURAL ENGINEER REGISTERED IN
 THE STATE OF FLORIDA BASED ON THE AREA WIND LOADING
 REQUIREMENTS, PLEASE SHOW CODE COMPLIANCE. LATERAL
 FORCE-RESISTING SYSTEM. FOR ALL ROOF TOP EQUIPMENT,
 CURBS, FANS OR A/C STANDS, AND OR VENTS, PIPE SUPPORTS
 ON THE ROOF DETAILED ATTACHMENT TO THE ROOF FRAMING &
 DECK AS WELL AS FROM THE CURB OR ROOF STAND TO THE
 EQUIPMENT ABOVE.
  
 17) SHEET 063_A501 DETAILS 1 & 3 BOTH SHOW THE USE OF 2
 INCH EFIS ON 5/8 INCH EXTERIOR GRADE PLYWOOD.
 PLEASE NOTE THE CONSTRUCTION TYPE FOR THIS BUILDING IS
 I-B. PLEASE REVIEW THE 2017 FBC-B SECTIONS:
  
 603.1 ALLOWABLE MATERIALS. COMBUSTIBLE MATERIALS SHALL
 BE PERMITTED IN BUILDINGS OF TYPE I OR II CONSTRUCTION
 IN THE FOLLOWING APPLICATIONS AND IN ACCORDANCE WITH
 SECTIONS 603.1.1 THROUGH 603.1.3:
 1.FIRE-RETARDANT-TREATED WOOD SHALL BE PERMITTED IN:
 1.1.NONBEARING PARTITIONS WHERE THE REQUIRED
 FIRE-RESISTANCE RATING IS 2 HOURS OR LESS.
 1.2.NONBEARING EXTERIOR WALLS WHERE
 FIRE-RESISTANCE-RATED CONSTRUCTION IS NOT REQUIRED.
 1.3.ROOF CONSTRUCTION, INCLUDING GIRDERS, TRUSSES,
 FRAMING AND DECKING.
  
 18) SHEET 063_A501 DETAILS 3 & 4 BOTH SHOW THE USE OF
 FIREPROOFING OF THE STEEL FRAMING ALSO SHEET 064_A525
 DETAILS 1,2 & 5. PLEASE PROVIDE CODE COMPLIANCE OF FIRE
 RESISTANCE RATING REQUIREMENT FOR BUILDINGS ELEMENTS
 SEE TABLE 601 AND FOOTNOTES OF THE 2017 FBC-B. THE
 ARCHITECTURAL SHEET ALSO STATES STEEL BEAM WITH SPRAY
 APPLIED FIREPROOFING, COORDINATE WITH STRUCTURAL STEEL
 DRAWINGS. SHEET 010_G164
 DOES HAVE FIRE RESISTANCE RATINGS FOR BAR JOIST BUT
 WITHIN THE SYSTEM THERE ARE DIFFERENT OR ALTERNATE
 METHODS OF APPLICATION, NO ONE METHOD HAS BEEN
 IDENTIFIED FOR USE IN THIS BUILDING. THERE IS NO
 INFORMATION ABOUT FIRE RESISTANCE RATING FOR THE STEEL
 COLUMNS.
  
 19) SHEET 069_A577 THERE ARE 3 DETAILS DETAIL # 1 & 2
 DOES NOT INDICATE THE TYPE OF SHEATHING TO BE
 INSTALLED. BOTH DETAIL 2 & 3 BOTH INDICATE SEE DETAIL #
 4 SHEET 011_G165. 2 INCH EFIS ON 5/8 INCH EXTERIOR
 SHEATHING. PLEASE NOTE THE CONSTRUCTION TYPE FOR THIS
 BUILDING IS I-B. PLEASE REVIEW THE 2017 FBC-B SECTIONS:
  
 603.1 ALLOWABLE MATERIALS. COMBUSTIBLE MATERIALS SHALL
 BE PERMITTED IN BUILDINGS OF TYPE I OR II CONSTRUCTION
 IN THE FOLLOWING APPLICATIONS AND IN ACCORDANCE WITH
 SECTIONS 603.1.1 THROUGH 603.1.3:
 1.FIRE-RETARDANT-TREATED WOOD SHALL BE PERMITTED IN:
 1.1.NONBEARING PARTITIONS WHERE THE REQUIRED
 FIRE-RESISTANCE RATING IS 2 HOURS OR LESS.
 1.2.NONBEARING EXTERIOR WALLS WHERE
 FIRE-RESISTANCE-RATED CONSTRUCTION IS NOT REQUIRED.
 1.3.ROOF CONSTRUCTION, INCLUDING GIRDERS, TRUSSES,
 FRAMING AND DECKING.
  
 20) SHEET 076_A800 PLEASE REVIEW THE UPPER LEFT HAND
 BREAK ROOM CABINETS, DETAIL NOT GIVEN A DETAIL NUMBER.
 THE SHELF THAT THE MICROWAVE SITS ON IS 4 FOOT 8 INCHES
 ABOVE FINISH FLOOR, OUT OF REACH RANGES.
 SEE THE 2017 FBC-ACCESSIBILITY CODE SECTIONS:
  
 308 REACH RANGES. 308.2 FORWARD REACH./ 308.2.1
 UNOBSTRUCTED/ 308.2.2 OBSTRUCTED HIGH REACH.
 308.3 SIDE REACH. / 308.3.1 UNOBSTRUCTED/ 308.3.2
 OBSTRUCTED HIGH REACH.
  
 309 OPERABLE PARTS. 309.3 HEIGHT. OPERABLE PARTS SHALL
 BE PLACED WITHIN ONE OR MORE OF THE REACH RANGES
 SPECIFIED IN 308.309.4 OPERATION. OPERABLE PARTS SHALL
 BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT
 GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE
 REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS
 (22.2 N) MAXIMUM.
  
 21A) SHEET 076_A800 PLEASE REVIEW DETAIL 11. THIS
 DETAIL GIVES AN ALTERNATE POSITION FOR A MICROWAVE. IT
 IS SHOWN ON AN UPPER CABINET SHELF AT A HEIGHT OF IS 4
 FOOT 8 INCHES ABOVE FINISH FLOOR, OUT OF REACH RANGES.
 SEE THE 2017 FBC-ACCESSIBILITY CODE SECTIONS:
  
 308 REACH RANGES. 308.2 FORWARD REACH./ 308.2.1
 UNOBSTRUCTED/ 308.2.2 OBSTRUCTED HIGH REACH.
 308.3 SIDE REACH. / 308.3.1 UNOBSTRUCTED/ 308.3.2
 OBSTRUCTED HIGH REACH.
  
 309 OPERABLE PARTS. 309.3 HEIGHT. OPERABLE PARTS SHALL
 BE PLACED WITHIN ONE OR MORE OF THE REACH RANGES
 SPECIFIED IN 308.309.4 OPERATION. OPERABLE PARTS SHALL
 BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT
 GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE
 REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS
 (22.2 N) MAXIMUM.
  
 21B) IN THE SAME DETAIL AN ALTERNATE POSITION IS SHOWN
 ON THE COUNTERTOP. THIS POSITION IS CODE COMPLIANT BUT
 SHOWN AS AN ALTERNATE POSITION, THE LOCATION HAS TO BE
 SPECIFIC. 2017 WEST PALM BEACH AMENDMENTS TO THE
 FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION
 107.2.1.
 W.P.B. ADMINISTRATIVE CODE/2017 DRAWINGS &
 SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM
 OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS,
 WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE
 TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC TO
 THE TECHNICAL CODES HALL NOT BE CITED AS A WHOLE OR IN
 PART, NOR THE TERM "LEGAL" OR ITS EQUIVALENT BE USED AS
 A SUBSTITUTE FOR SPECIFIC INFORMATION. CONSTRUCTION
 DOCUMENTS SHALL BE SUFFICIENT CLARITY TO INDICATE THE
 LOCATION, NATURE AND EXTENT OF THE WORK PROPOSED AND
 SHOW IN DETAIL THAT IT WILL CONFORM TO THE PROVISIONS
 OF THIS CODE AND RELEVANT LAWS, ORDINANCES, RULES AND
 REGULATIONS, AS DETERMINED BY THE BUILDING OFFICIAL.
  
 22) SHEET 007_A801 PLEASE REVIEW DETAIL 5 THE STAFF
 LOUNGE AND DETAIL 8 THE EMS LOUNGE. THESE DETAIL GIVES
 AN ALTERNATE POSITION FOR A MICROWAVE. IT IS SHOWN ON
 AN UPPER CABINET SHELF AT A HEIGHT OF IS 4 FOOT 8
 INCHES ABOVE FINISH FLOOR, OUT OF REACH RANGES.
 SEE THE 2017 FBC-ACCESSIBILITY CODE SECTIONS:
  
 308 REACH RANGES. 308.2 FORWARD REACH./ 308.2.1
 UNOBSTRUCTED/ 308.2.2 OBSTRUCTED HIGH REACH.
 308.3 SIDE REACH. / 308.3.1 UNOBSTRUCTED/ 308.3.2
 OBSTRUCTED HIGH REACH.
  
 309 OPERABLE PARTS. 309.3 HEIGHT. OPERABLE PARTS SHALL
 BE PLACED WITHIN ONE OR MORE OF THE REACH RANGES
 SPECIFIED IN 308.309.4 OPERATION. OPERABLE PARTS SHALL
 BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT
 GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE
 REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS
 (22.2 N) MAXIMUM.
  
 23) PLEASE SUPPLY A SURVEY FOR THIS PROPERTY INDICATING
 THE DISTANCE FROM THE CURRENT BUILDING LOCATION TO THE
 EAST PROPERTY LINE TO VERIFY THE EXTERIOR WALL RATING
 FBC-B TABLE 602 AND THE AMOUNT OF ALLOWABLE OPENINGS
 FOR UNPROTECTED AND SPRINKLERED FBC-B TABLE 705.8.
  
 24) IMPACT FEES - DIGITAL SUBMITTALS: PLANS WILL BE
 REVIEWED BY THE PBC IMPACT FEE OFFICE DIGITALLY VIA
 PROJECT DOX UPON NOTIFICATION BY THIS OFFICE.
 NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST FINAL
 FORM. YOU MAY COORDINATE WITH THE IMPACT FEE OFFICE AT
 (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL IMPACT
 FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME THE
 FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM CAN
 BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINISTRAT
 ION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO: [email protected]
 PALM BEACH COUNTY IMPACT FEE OFFICE IS LOCATED AT 2300
 N. JOG RD. ROOM?S 2W01-2W14 WEST PALM BEACH, FL.
  
 25) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2019-09-13 Cont ID  
Sent By jpearson Date 2019-09-13 Time 15:51 Rev Time 0.00
Received By jpearson Date 2019-09-13 Time 15:09 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2019-07-17 Cont ID  
Sent By jpearson Date 2019-07-17 Time 14:48 Rev Time 0.00
Received By jpearson Date 2019-07-17 Time 14:48 Sent To  
Notes
2019-07-17 14:48:36CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. NO ELECTRICAL ISSUED FOR PLAN, ALL ITEMS HAVE BEEN
 ADDRESSED. HOWEVER, I AM UNABLE TO APPROVE THE PLAN
 UNTIL THE SIGNATURE ISSUE IS RESOLVED. SEE SIGNATURE
 COMMENTS. WPB FBC 107.1; FS 471/481
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-02-22 Cont ID  
Sent By jpearson Date 2019-02-22 Time 15:45 Rev Time 0.00
Received By jpearson Date 2019-02-22 Time 15:45 Sent To  
Notes
2019-02-22 15:45:00CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. INDICATE ON PLANS WHICH ROOMS/AREAS SHALL BE WIRED
 PER NEC 517.13.
 2. PROVIDE PANEL BOARD BONDING PER NEC 517.14.
 3. PANEL SCHEDULES SHOW DEMAND FACTORS FOR VARIOUS
 ITEMS THAT DON'T SEEM TO BE CODE COMPLIANT. FOR
 EXAMPLE, SOME LIGHTING IS SHOWN WITH A DEMAND FACTOR OF
 40%, BUT THE PLAN DOES NOT CLARIFY WHAT THESE AREAS
 ARE. THIS DEMAND FACTOR CANNOT BE APPLIED TO AREAS OF A
 HOSPITAL WHERE THE LIGHTING LOAD IS LIKELY TO BE USED
 AT ONE TIME, SUCH AS AN EMERGENCY DEPARTMENT. PROVIDE
 CLARIFICATION. ANOTHER EXAMPLE IS THE DEMAND FACTOR OF
 85% APPLIED TO SOME AREAS. WHAT IS THE CODE REFERENCE
 THAT PERMITS THIS? ALSO, THE DEMAND FACTORS FOR
 RECEPTACLE LOADS IS NOT COMPLIANT WITH NEC TABLE
 220.44. PROVIDE CORRECTIONS AS NEEDED, AND UPDATE LOAD
 SUMMARIES TO REFLECT CHANGES. NEC 220; WPB FBC 107.2.1
 4. SHEET E-701 PROVIDES LOAD SUMMARIES AND SHOWS THE
 EXISTING LOADS FOR EACH OF THOSE SUMMARIES. WHERE IS
 THIS INFORMATION FROM, HOW ARE THESE EXISTING LOADS
 DETERMINED? PROVIDE CLARIFICATION. NEC 220; WPB FBC
 107.2.1
 5. BE ADVISED THAT FIRE ALARM, LOW VOLTAGE SYSTEMS,
 DAS, LIGHTNING PROTECTION, GENERATORS, COMMERCIAL HOOD
 SYSTEMS, WALK IN COOLERS, SIGNS, SITE LIGHTING, AND
 SWIMMING POOLS (WHERE APPLICABLE) ARE NOT INCLUDED IN
 THE SCOPE OF THIS PLAN REVIEW. PROVIDE A BLOCK NOTE
 INDICATING THE REQUIRED SEPARATE PERMITS AND PLAN
 SUBMITTALS FOR ANY OF THESE SYSTEMS PRESENT. WPB FBC
 105.1, 107.2.1
  
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop ENG ENGINEERING CSD
Rev No 3 Status P Date 2019-10-08 Cont ID  
Sent By rrossano Date 2019-10-08 Time   Rev Time 0.00
Received By rrossano Date 2019-10-08 Time   Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2019-07-17 Cont ID  
Sent By rrossano Date 2019-07-17 Time   Rev Time 0.00
Received By rrossano Date 2019-07-17 Time   Sent To I
Notes
2019-07-17 15:47:05PASSED WITH PROVISO: FORMAL PLAN REVIEW VIA ENGINEERING
 PERMIT APPLICATION WAS SATISFACTORY. ANY UPDATES OR
 REVISIONS TO THE APPROVED SITE PLAN WILL REQUIRE AN
 ENGINEERING REVISION REVIEW.
  
 FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR
 CONCERNS, THANKS.
  
 RICK ROSSANO
 PROJECT COORDINATOR
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1098
 FAX: (561) 494-1116
 MOBILE: (561) 246-9525
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
 MANNY GONZALEZ
 SENIOR ENGINEERING PROJECT COORDINATOR
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 MOBILE: (561) 644-7301
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
 CENTRAL OPERATIONS CENTER (DISPATCH):
 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC
 UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2019-02-07 Cont ID  
Sent By rrossano Date 2019-02-07 Time 11:40 Rev Time  
Received By rrossano Date 2019-02-07 Time   Sent To  
Notes
2019-02-07 11:38:16PLEASE ADD THE ADDITIONAL WATER AND SEWER DEMANDS FOR
 THE SUBJECT PROJECT ON SHEETS C400 AND C401.
  
 FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR
 CONCERNS, THANKS.
  
 RICK ROSSANO
 PROJECT COORDINATOR
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1098
 FAX: (561) 494-1116
 MOBILE: (561) 246-9525
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
 MANNY GONZALEZ
 SENIOR ENGINEERING PROJECT COORDINATOR
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 MOBILE: (561) 644-7301
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
 CENTRAL OPERATIONS CENTER (DISPATCH):
 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC
 UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2019-08-20 Cont ID  
Sent By pleduc Date 2019-08-20 Time   Rev Time 0.00
Received By pleduc Date 2019-08-20 Time 09:31 Sent To  
Notes
2019-08-20 10:01:508/20/19
  
 A FEW OF THE PEVIOUS FIRE COMMENTS DO NOT APPEAR TO BE
 ADDRESSED.
  
  
  
 1) COMPLIED
  
  
  
 2) PROVISO COMMENT:
  
 SHEET A 575 - THERE ARE INDICATIONS OF CARDER READERS
 AND ACCESS CONTROL WITHIN THE DOOR SCHEDULE.
  
 CARD READER AND ACCESS CONTROL SHALL BE INSTALLED UNDER
 SPEARATE PERMIT AND SHOP DRAWINGS.
  
 ALL DEVICES AND EQUIPMENT FOR CARD READERS AND ACCESS
 CONTRAL SHALL FUNCTION/OPERATE UNDER THE REQUIREMENTS
 OF NFPA 101, CHAPTER 7, MEANS OF EGRESS.
  
  
  
 3) COMPLIED
  
  
  
 4) COMPLIED
  
  
 5) PROVISO COMMENT:
  
 SHEET G 410 - THERE IS AN INDICATION OF A TEMPORARY
 AMBULANCE CANOPY. THERE IS NO DETAIL PLAN SHEET OR
 CALL-OUT DRAWING.
  
 IF THIS A TENT STRUCTURE, IS THE FABRIC FIRE RETARDENT,
 SIZE, HEIGHT, SIDES, LIGHTING, ETC.?
  
 ANY TEMPORAY TENT STRUCTURE SHALL BE INSTALLED UNDER
 SEPARATE PERMIT AND SHOP DRAWINGS THAT INCLUDE, THE
 ABOVE.
  
  
  
 6) PROVISO COMMENT:
  
 SHEET G 410 - A CONSTRUCTION BARRIER IS INDICATED.
 THERE IS NO DETAIL PLAN SHEET OR CALL-OUT DRAWING.
  
 WILL THIS AREA BE CONSTRUCTION MATERIAL, HAVE LIGHTING,
 EXIT SIGNAGE, SIDES, SPRINKLER PROTECTION, FIRE ALARM
 DEVICES, ETC.
  
 SHOP DRAWINGS REQUIRED
  
  
  
 7) PROVISO COMMENT:
  
 SHEET G 410 - A TEMPORARY PUB ED CANOPY IS INDICATED.
 WHAT IS THE PURPOSE AND OCCUPANCY CLASSIFICATION OF
 THIS CANOPY?
  
 EDUCATION CLASSROOM, ASEEMBLY GATHERING AREA,? HOW WILL
 IT BE CONSTRUCTED? IS IT TEMPORARY TENT WITH SIDES?
  
 ANY TEMPORAY TENT STRUCTURE SHALL BE INSTALLED UNDER
 SEPARATE PERMIT AND SHOP DRAWINGS THAT INCLUDE, THE
 ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2019-06-13 Cont ID  
Sent By pleduc Date 2019-06-13 Time   Rev Time 0.00
Received By pleduc Date 2019-06-13 Time 15:41 Sent To  
Notes
2019-06-13 16:01:586/13/19
  
 PEVIOUS FIRE COMMENTS DO NOT APPEAR TO BE ADDRESSED IN
 NARRATIVE NOR PLAN REVISION FORM.
  
 PLEASE ADDRESS THE FIRE COMMENTS THAT WERE PREVIOUSLY
 SUBMITTED AND RESUBMITTED BELOW:
  
  
  
 1) SHEET D 110 - THERE ARE NO INDICATIONS THAT THE LIFE
 SAFETY SYSTEMS SHALL BE MAINTAINED DURING DEMO AND/OR
 THROUGHOUT CONSTRUCTION.
  
 IT IS OF THE UTMOST IMPORTANCE THAT THE FIRE ALARM AND
 FIRE SPRINKLER BE MAINTAINED AT ALL TIMES.
  
 PLEASE PROVIDE A NOTE OF ACKNOWLEDGEMENT.
  
  
  
 2) SHEET A 575 - THERE ARE INDICATIONS OF CARDER
 READERS AND ACCESS CONTROL WITHIN THE DOOR SCHEDULE.
  
 CARD READER AND ACCESS CONTROL SHALL BE INSTALLED UNDER
 SPEARATE PERMIT AND SHOP DRAWINGS.
  
 ALL DEVICES AND EQUIPMENT FOR CARD READERS AND ACCESS
 CONTRAL SHALL FUNCTION/OPERATE UNDER THE REQUIREMENTS
 OF NFPA 101, CHAPTER 7, MEANS OF EGRESS.
  
 PLEASE PROVIDE A NOTE OF ACKNOWLEDGEMENT.
  
  
  
 3) SHEET FP 001 - THERE ARE INDICATIONS OF FIRE
 SPRINKLER WORK.
  
 ALL FIRE SPRINKLER WORK, DEMO THRU NEW CONSTRUCTION,
 SHALL BE DONE UNDER SEPARATE PERMIT AND SHOP DRAWINGS
 BY CERTIFIED FIRE SPRINKLER CONTRATORS.
  
 PLEASE PROVIDE A NOTE OF ACKNOWLEDGEMENT.
  
  
  
 4) SHEET E 000 - THERE ARE NO INDICATIONS OF FIRE ALARM
 DEVICES/ EQUIPMENT OR FIRE ALARM WORK.
  
 ALL FIRE ALARM WORK, DEMO THRU NEW CONSTRUCTION, SHALL
 BE DONE UNDER SEPARATE PERMIT AND SHOP DRAWINGS BY
 CERTIFIED FIRE ALARM CONTRATORS.
  
 PLEASE PROVIDE A NOTE OF ACKNOWLEDGEMENT.
  
  
 5) SHEET G 410 - THERE IS AN INDICATION OF A TEMPORARY
 AMBULANCE CANOPY. THERE IS NO DETAIL PLAN SHEET OR
 CALL-OUT DRAWING.
  
 IF THIS A TENT STRUCTURE, IS THE FABRIC FIRE RETARDENT,
 SIZE, HEIGHT, SIDES, LIGHTING, ETC.?
  
 ANY TEMPORAY TENT STRUCTURE SHALL BE INSTALLED UNDER
 SEPARATE PERMIT AND SHOP DRAWINGS THAT INCLUDE, THE
 ABOVE.
  
 PLEASE PROVIDE DETAILS AND/OR A NOTE OF
 ACKNOWLEDGEMENT.
  
  
  
 6) SHEET G 410 - A CONSTRUCTION BARRIER IS INDICATED.
 THERE IS NO DETAIL PLAN SHEET OR CALL-OUT DRAWING.
  
 WILL THIS AREA BE CONSTRUCTION MATERIAL, HAVE LIGHTING,
 EXIT SIGNAGE, SIDES, SPRINKLER PROTECTION, FIRE ALARM
 DEVICES, ETC.
  
 PLEASE PROVIDE DETAILS.
  
  
  
 7) SHEET G 410 - A TEMPORARY PUB ED CANOPY IS
 INDICATED. WHAT IS THE PURPOSE AND OCCUPANCY
 CLASSIFICATION OF THIS CANOPY?
  
 EDUCATION CLASSROOM, ASEEMBLY GATHERING AREA,? HOW WILL
 IT BE CONSTRUCTED? IS IT TEMPORARY TENT WITH SIDES?
  
 ANY TEMPORAY TENT STRUCTURE SHALL BE INSTALLED UNDER
 SEPARATE PERMIT AND SHOP DRAWINGS THAT INCLUDE, THE
 ABOVE.
  
 PLEASE PROVIDE DETAILS AND/OR A NOTE OF
 ACKNOWLEDGEMENT.
  
  
  
 8) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
  
 9)ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2019-02-21 Cont ID  
Sent By pleduc Date 2019-02-21 Time   Rev Time 0.00
Received By pleduc Date 2019-01-31 Time 10:48 Sent To  
Notes
2019-02-21 10:17:58THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
  
 1) SHEET D 110 - THERE ARE NO INDICATIONS THAT THE LIFE
 SAFETY SYSTEMS SHALL BE MAINTAINED DURING DEMO AND/OR
 THROUGHOUT CONSTRUCTION.
  
 IT IS OF THE UTMOST IMPORTANCE THAT THE FIRE ALARM AND
 FIRE SPRINKLER BE MAINTAINED AT ALL TIMES.
  
 PLEASE PROVIDE A NOTE OF ACKNOWLEDGEMENT.
  
  
  
 2) SHEET A 575 - THERE ARE INDICATIONS OF CARDER
 READERS AND ACCESS CONTROL WITHIN THE DOOR SCHEDULE.
  
 CARD READER AND ACCESS CONTROL SHALL BE INSTALLED UNDER
 SPEARATE PERMIT AND SHOP DRAWINGS.
  
 ALL DEVICES AND EQUIPMENT FOR CARD READERS AND ACCESS
 CONTRAL SHALL FUNCTION/OPERATE UNDER THE REQUIREMENTS
 OF NFPA 101, CHAPTER 7, MEANS OF EGRESS.
  
 PLEASE PROVIDE A NOTE OF ACKNOWLEDGEMENT.
  
  
  
 3) SHEET FP 001 - THERE ARE INDICATIONS OF FIRE
 SPRINKLER WORK.
  
 ALL FIRE SPRINKLER WORK, DEMO THRU NEW CONSTRUCTION,
 SHALL BE DONE UNDER SEPARATE PERMIT AND SHOP DRAWINGS
 BY CERTIFIED FIRE SPRINKLER CONTRATORS.
  
 PLEASE PROVIDE A NOTE OF ACKNOWLEDGEMENT.
  
  
  
 4) SHEET E 000 - THERE ARE NO INDICATIONS OF FIRE ALARM
 DEVICES/ EQUIPMENT OR FIRE ALARM WORK.
  
 ALL FIRE ALARM WORK, DEMO THRU NEW CONSTRUCTION, SHALL
 BE DONE UNDER SEPARATE PERMIT AND SHOP DRAWINGS BY
 CERTIFIED FIRE ALARM CONTRATORS.
  
 PLEASE PROVIDE A NOTE OF ACKNOWLEDGEMENT.
  
  
 5) SHEET G 410 - THERE IS AN INDICATION OF A TEMPORARY
 AMBULANCE CANOPY. THERE IS NO DETAIL PLAN SHEET OR
 CALL-OUT DRAWING.
  
 IF THIS A TENT STRUCTURE, IS THE FABRIC FIRE RETARDENT,
 SIZE, HEIGHT, SIDES, LIGHTING, ETC.?
  
 ANY TEMPORAY TENT STRUCTURE SHALL BE INSTALLED UNDER
 SEPARATE PERMIT AND SHOP DRAWINGS THAT INCLUDE, THE
 ABOVE.
  
 PLEASE PROVIDE DETAILS AND/OR A NOTE OF
 ACKNOWLEDGEMENT.
  
  
  
 6) SHEET G 410 - A CONSTRUCTION BARRIER IS INDICATED.
 THERE IS NO DETAIL PLAN SHEET OR CALL-OUT DRAWING.
  
 WILL THIS AREA BE CONSTRUCTION MATERIAL, HAVE LIGHTING,
 EXIT SIGNAGE, SIDES, SPRINKLER PROTECTION, FIRE ALARM
 DEVICES, ETC.
  
 PLEASE PROVIDE DETAILS.
  
  
  
 7) SHEET G 410 - A TEMPORARY PUB ED CANOPY IS
 INDICATED. WHAT IS THE PURPOSE AND OCCUPANCY
 CLASSIFICATION OF THIS CANOPY?
  
 EDUCATION CLASSROOM, ASEEMBLY GATHERING AREA,? HOW WILL
 IT BE CONSTRUCTED? IS IT TEMPORARY TENT WITH SIDES?
  
 ANY TEMPORAY TENT STRUCTURE SHALL BE INSTALLED UNDER
 SEPARATE PERMIT AND SHOP DRAWINGS THAT INCLUDE, THE
 ABOVE.
  
 PLEASE PROVIDE DETAILS AND/OR A NOTE OF
 ACKNOWLEDGEMENT.
  
  
  
 8) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
  
 9)ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2019-10-31 Cont ID  
Sent By lmarchan Date 2019-10-31 Time 07:38 Rev Time 0.00
Received By lmarchan Date 2019-10-15 Time 10:56 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-10-08 Cont ID  
Sent By cpuell Date 2019-10-08 Time 14:18 Rev Time 0.00
Received By cpuell Date 2019-08-16 Time 06:25 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-07-24 Cont ID  
Sent By lmarchan Date 2019-07-24 Time 15:16 Rev Time 0.00
Received By lmarchan Date 2019-06-12 Time 15:56 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-03-15 Cont ID  
Sent By lmarchan Date 2019-03-15 Time 15:32 Rev Time 0.00
Received By lmarchan Date 2019-01-14 Time 16:44 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2019-10-31 Cont ID  
Sent By lmarchan Date 2019-10-31 Time 13:39 Rev Time 0.00
Received By lmarchan Date 2019-10-25 Time 09:44 Sent To  
Notes
2019-10-31 13:10:16RECEIPT - 2019-1031-364 - $28,049.44 - PAID
2019-10-25 09:44:2810/25/19 EMAILED IMPACT FEE OFFICE. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2019-02-12 Cont ID  
Sent By jwitmer Date 2019-02-12 Time 14:18 Rev Time 0.00
Received By jwitmer Date 2019-02-12 Time 14:17 Sent To  
Notes
2019-02-12 14:17:59IMPACT FEES - DIGITAL SUBMITTALS:
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected] .
 PALM BEACH COUNTY IMPACT FEE OFFICE IS LOCATED AT 2300
 N. JOG RD. ROOM?S 2W01-2W14 WEST PALM BEACH, FL.
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2019-09-16 Cont ID  
Sent By ccole Date 2019-09-14 Time 08:05 Rev Time 0.00
Received By ccole Date 2019-09-16 Time 08:05 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2019-07-16 Cont ID  
Sent By ccole Date 2019-07-16 Time 08:32 Rev Time 0.00
Received By ccole Date 2019-07-15 Time 16:48 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2019-02-26 Cont ID  
Sent By ccole Date 2019-02-26 Time 17:12 Rev Time 0.00
Received By ccole Date 2019-02-26 Time 12:25 Sent To  
Notes
2019-02-26 17:48:391ST REVIEW FBC-2017 MECHANICAL
 PERMIT #18091284
 2/26/19
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
 FGI- GUIDELINES FOR DESIGN AND CONSTRUCTION OF
 HOSPITALS AND OUTPATIENT FACILITIES- 2014.
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET M002: PROVIDE THE MINIMUM EFFICIENCY RATINGS
 OF THE DUCTLESS SYSTEMS AND THE CHILLERS IN THE
 EQUIPMENT SCHEDULES- SEE TABLES C403.2.3(1) &
 C403.2.3(7) FBC M.
  
 2) M110B & M301: PROVIDE A AUTOMATICALLY CONTROLLED
 DAMPER FOR THE O/A INTAKE DUCT FOR AHU-22- SECTION
 C403.2.4.2 FBC M.
  
 3) M110B & M301: SHOW THE LOCATION OF THE REQUIRED DUCT
 SMOKE DETECTOR FOR AHU-22- SECTION 606.2.1 FBC M.
  
 4) M110B: INDICATE THE TYPE OF DUCTWORK AND DIFFUSERS
 TO BE INSTALLED IN THE TRAUMA ROOM- SEE TABLE 6-2
 ASHRAE 170-2008
  
 5) M404, DETAIL 1: INDICATE HOW THE FAN CURB WILL BE
 ATTACHED TO THE STRUCTURE AND SUBMIT A MIAMI-DADE NOA
 FOR THE EXHAUST FANS PER NOTE 7- SECTION 301.15 FBC M.
  
 6) PROVIDE WIND LOAD ENGINEERING FOR INSTALLATION OF
 THE CHILLER AND SUPPORT BASE- SECTION 301.15 FBC M.
  
 7) REQUIRED SUBMITTALS TO BE APPROVED BY THE ENGINEER
 OF RECORD:
  
 A) EXHAUST FANS
 B) FILTER BANKS
 C) DUCTWORK
 D) TRAUMA ROOM DIFFUSERS
 E) FIRE AND FIRE/SMOKE DAMPERS
 G) TERMINAL REHEAT BOXES.
  
 8) COMMISSIONING REPORT FOR THE MECHANICAL AND SERVICE
 WATER SYSTEMS ARE REQUIRED FOR CO- SEE SECTION C408 FBC
 EC.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop MEDGAS MEDICAL GAS
Rev No 5 Status P Date 2019-10-30 Cont ID  
Sent By gjohnson Date 2019-10-30 Time 11:41 Rev Time 0.00
Received By gjohnson Date 2019-10-30 Time 11:41 Sent To  
Notes
***NONE***

Review Stop MEDGAS MEDICAL GAS
Rev No 4 Status P Date 2019-10-04 Cont ID  
Sent By gjohnson Date 2019-10-04 Time 12:21 Rev Time 0.00
Received By gjohnson Date 2019-10-04 Time 12:21 Sent To  
Notes
2019-10-04 12:21:59PLUMBING PROVISO : 18091284
  
 MED GAS COMMENTS: SHALL BE COMPLIED WITH PRIOR TO FINAL
 INSPECTION.
  
 1) SHOW THE TERMINATION POINT OF THE VACUUM PUMP VENT
 LINE. THE DISCHARGE SHALL BE A MINIMUM OF 25 FEET FROM
 ANY DOOR, WINDOW, AIR INTAKE, OR OTHER OPENINGS IN
 BUILDINGS. NFPA 99 SEC.5.1.3.7.6.2.
  
 2) THE MEDICAL AIR INTAKE SHALL BE LOCATED A MINIMUM OF
 25 FEET FROM VENTILATING SYSTEM EXHAUSTS, PLUMBING
 VENTS, VACUUM DISCHARGES, OR OTHER AREAS THAT CAN
 COLLECT OTHER NOXIOUS FUMES. NFPA 99 SEC. 5.1.3.6.3.11.
  
 DEFERRED SUBMITTALS. SUBMIT MANUFACTURER'S
 SPECIFICATIONS FOR THE VACUUM PUMPS AND AIR
 COMPRESSORS, THE MUFFLER/INTAKE AND ALSO FOR THE
 RECEIVERS, DRYERS, AFTERCOOLERS, ETC.IF THEY ARE BEING
 REPLACED WITH NEW. WPB AMEND. TO FBC SEC. 107.3.4.1
  
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]

Review Stop MEDGAS MEDICAL GAS
Rev No 3 Status F Date 2019-09-18 Cont ID  
Sent By gjohnson Date 2019-09-18 Time 12:57 Rev Time 0.00
Received By gjohnson Date 2019-09-18 Time 12:57 Sent To  
Notes
2019-09-18 12:57:473RD REVIEW:
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
  
 MED GAS COMMENTS: PREVIOUS COMMENTS NOT COMPLIED WITH
  
 1) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE VACUUM
 PUMPS AND AIR COMPRESSORS, THE MUFFLER/INTAKE AND ALSO
 FOR THE RECEIVERS, DRYERS, AFTERCOOLERS, ETC.IF THEY
 ARE BEING REPLACED WITH NEW. WPB AMEND. TO FBC SEC.
 107.2.1.
  
 3) SHOW THE TERMINATION POINT OF THE VACUUM PUMP VENT
 LINE. THE DISCHARGE SHALL BE A MINIMUM OF 25 FEET FROM
 ANY DOOR, WINDOW, AIR INTAKE, OR OTHER OPENINGS IN
 BUILDINGS. NFPA 99 SEC.5.1.3.7.6.2.
 4) THE MEDICAL AIR INTAKE SHALL BE LOCATED A MINIMUM OF
 25 FEET FROM VENTILATING SYSTEM EXHAUSTS, PLUMBING
 VENTS, VACUUM DISCHARGES, OR OTHER AREAS THAT CAN
 COLLECT OTHER NOXIOUS FUMES. NFPA 99 SEC. 5.1.3.6.3.11.
  
 6) SHT.P002 - DETAIL # 7 - A PRESSURE INDICATOR(S)
 SHALL BE LOCATED DOWNSTREAM OF EACH REGULATOR OR
 IMMEDIATELY DOWNSTREAM OF THE ISOLATING VALVES FOR THE
 REGULATORS PER NFPA 99 SEC. 5.1.3.5.5.1 (3).
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]

Review Stop MEDGAS MEDICAL GAS
Rev No 2 Status F Date 2019-07-14 Cont ID  
Sent By tklarge Date 2019-07-14 Time 09:49 Rev Time 0.00
Received By tklarge Date 2019-07-14 Time 09:14 Sent To  
Notes
2019-07-14 09:17:551) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE VACUUM
 PUMPS AND AIR COMPRESSORS, THE MUFFLER/INTAKE AND ALSO
 FOR THE RECEIVERS, DRYERS, AFTERCOOLERS, ETC.IF THEY
 ARE BEING REPLACED WITH NEW. WPB AMEND. TO FBC SEC.
 107.2.1.
 2) THE VACUUM PUMPS SHALL BE PROVIDED WITH
 ANTIVIBRATION MOUNTINGS PERR NFPA 99 SEC.5.1.3.7.2.2.
 3) SHOW THE TERMINATION POINT OF THE VACUUM PUMP VENT
 LINE. THE DISCHARGE SHALL BE A MINIMUM OF 25 FEET FROM
 ANY DOOR, WINDOW, AIR INTAKE, OR OTHER OPENINGS IN
 BUILDINGS. NFPA 99 SEC.5.1.3.7.6.2.
 4) THE MEDICAL AIR INTAKE SHALL BE LOCATED A MINIMUM OF
 25 FEET FROM VENTILATING SYSTEM EXHAUSTS, PLUMBING
 VENTS, VACUUM DISCHARGES, OR OTHER AREAS THAT CAN
 COLLECT OTHER NOXIOUS FUMES. NFPA 99 SEC. 5.1.3.6.3.11.
 5) MEDICAL AIR DRYERS SHALL BE PROVIDED WITH
 ANTIVIBRATION MOUNTINGS PER NFPA 99 SEC. 5.1.3.6.3.7
 (4).
 6) SHT.P002 - DETAIL # 7 - A PRESSURE INDICATOR(S)
 SHALL BE LOCATED DOWNSTREAM OF EACH REGULATOR OR
 IMMEDIATELY DOWNSTREAM OF THE ISOLATING VALVES FOR THE
 REGULATORS PER NFPA 99 SEC. 5.1.3.5.5.1 (3).
 7) SUBMIT RISER DIAGRAMS FOR ALL THE MEDICAL GAS PIPING
 TO BE INSTALLED. WPB AMEND. TO FBC SEC. 107.2.1.
 8) SHT. P002 - DETAIL #7 - THE PRESSURE RELIEF VALVES
 ON THE COMPRESSED AIR SYSTEM SHALL BE VENTED IN
 ACCORDANCE WITH NFPA 99 SEC. 5.1.3.5.6.1 (4).
 9) IDENTIFY THE CONTINUATION POINTS OF THE MEDICAL GAS
 PIPING ON THE REQUESTED MEDICAL GAS RISER DIAGRAMS. WPB
 AMEND. TO FBC SEC. 107.2.1.
 10) THE AREA(S) HOUSING THE VACUUM PUMP AND AIR
 COMPRESSOR SHALL BE VENTILATED PER NFPA 99
 SECS.5.1.3.3.3.3, 5.1.3.6.3.1, 5.1.3.7.1.1.
 11) THE NEW OUTDOOR ENCLOSURE FOR THE MEDICAL GAS SHALL
 BE VENTILATED PER NFPA 99 SEC.5.1.3.3.3.4 (1).
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  

Review Stop MEDGAS MEDICAL GAS
Rev No 1 Status F Date 2019-02-28 Cont ID  
Sent By gjohnson Date 2019-02-28 Time 14:03 Rev Time 0.00
Received By gjohnson Date 2019-02-28 Time 14:03 Sent To  
Notes
2019-02-28 14:04:101ST REVIEW:
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 MED GAS COMMENTS:
  
 1. PLEASE PLACE NOTE ON PLAN THE CONTRACTOR AND ANYONE
 INSTALLING MED GAS PIPING SHALL BE MED GAS CERTIFIED.
 INSTALLERS SHALL PROVIDE FOR INSPECTORS ON JOBSITE AND
 COPY'S PROVIDED FOR PERMIT ISSUE. PER FAC 61G4-15.031
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]

Review Stop P PLUMBING
Rev No 4 Status P Date 2019-10-30 Cont ID  
Sent By gjohnson Date 2019-10-30 Time 11:40 Rev Time 0.00
Received By gjohnson Date 2019-10-30 Time 11:40 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2019-09-18 Cont ID  
Sent By gjohnson Date 2019-09-18 Time 14:14 Rev Time 0.00
Received By gjohnson Date 2019-09-12 Time 12:00 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2019-07-14 Cont ID  
Sent By tklarge Date 2019-07-14 Time 09:14 Rev Time 0.00
Received By tklarge Date 2019-07-09 Time 04:48 Sent To  
Notes
2019-07-14 06:21:041) SHT. G171 - DETAILS #1,2,3 - THERE IS NO APPROVED
 LISTING FOR THESE PENETRATION DETAILS. CLARIFY. AN
 ENGINEERING JUDGEMENT MAY BE REQUIRED FROM UL. 2017 FBC
 SEC. 714.
 2) SHT. G175 - DETAIL #6 - CLARIFY THE LOCATION OF THE
 REQUIRED CLEAR FLOOR SPACE FOR THE DRINKING FOUNTAIN.
 THE CLEAR FLOOR SPACE SHALL COMPLY WITH 2107 FBC SEC.
 602.2 AND BE CENTERED ON THE UNIT.
 3) SHT. A600 - DETAIL #2 - SHOW THE CLEAR INSIDE
 DIMENSIONS (L X W) OF THE ACCESSIBLE SHOWER. TRANSFER
 SHOWERS SHALL BE 36 INCHES BY 36 INCHES AND SHALL
 COMPLY WITH 2017 FBC - ACCESSIBILITY SEC.608.2.
 4) GRAB BARS IN THE TRANSFER SHOWER SHALL COMPLY WITH
 2017 FBC-ACCESSIBILITY SEC. 608.3.1.
 5) A SHOWER SPRAY UNIT SHALL BE PROVIDED IN THE SHOWER
 AND COMPLY WITH 2017 FBC-ACCESS/ SEC.608.6.
 6) THRESHOLD FOR THE SHOWER SHALL COMPLY WITH 2017 FBC
 -ACCESS. SEC.608.7.
 7) THE SEAT IN THE ACCESSIBLE SHOWER SHALL COMPLY WITH
 2017 FBC- ACCESS. SEC. 610.3.2.
 8) SHT.A351 - DETAIL #1 - THE OVERFLOW SCUPPER SHALL BE
 LOCATED NO MORE THAN 4 INCHES ABOVE THE FINISHED ROOF
 COVERING AND SHALL BE LOCATED AS CLOSE AS PRACTICAL TO
 REQUIRED VERTICAL LEADERS OR DOWNSPOUTS PER 2017 FBC
 SEC.1503.4.2.1.
 9) SHT. A600 SHOWS A GRAB BAR IN THE VERTICAL POSITION.
 GRAB BARS ARE NOT PERMITTED TO BE INSTALLED IN A
 VETICAL POSITION PER 2017 FBC-ACCESS. SEC.609.4.
 10) SHT. A600 - TOILET ACCESSORY LEGEND - IDENTIFY ON
 THE GRAB BAR DETAILS WHICH DETAILS APPLY TO THE SIDE
 WALL GRAB BAR AND WHICH ONES APPLY TO THE REAR WALL. IT
 IS CONFUSING . 2017 FBC - ACCESS. SEC.604.5.1 &
 604.5.2.
 11) SHT. A600 - DETAIL # 2 - THE DOOR CANNOT SWING INTO
 THE REQUIRED CLEAR FLOOR SPACE FOR THE LAVATORY AND THE
 SHOWER. 2017 FBC - ACCESS. SEC.603.2.3. SEE EXCEPTION
 #2.
 12) SHT. A652 - DETAIL #4 - SHOW THE MOUNTING HEIGHT OF
 THE LAVATORY IN THE NURSE'S STATION.
 13) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE VACUUM
 PUMPS AND AIR COMPRESSORS, THE MUFFLER/INTAKE AND ALSO
 FOR THE RECEIVERS, DRYERS, AFTERCOOLERS, ETC.IF THEY
 ARE BEING REPLACED WITH NEW. WPB AMEND. TO FBC SEC.
 107.2.1.
 14) THE VACUUM PUMPS SHALL BE PROVIDED WITH
 ANTIVIBRATION MOUNTINGS PERR NFPA 99 SEC.5.1.3.7.2.2.
 15) SHOW THE TERMINATION POINT OF THE VACUUM PUMP VENT
 LINE. THE DISCHARGE SHALL BE A MINIMUM OF 25 FEET FROM
 ANY DOOR, WINDOW, AIR INTAKE, OR OTHER OPENINGS IN
 BUILDINGS. NFPA 99 SEC.5.1.3.7.6.2.
 16) THE MEDICAL AIR INTAKE SHALL BE LOCATED A MINIMUM
 OF 25 FEET FROM VENTILATING SYSTEM EXHAUSTS, PLUMBING
 VENTS, VACUUM DISCHARGES, OR OTHER AREAS THAT CAN
 COLLECT OTHER NOXIOUS FUMES. NFPA 99 SEC. 5.1.3.6.3.11.
 17) MEDICAL AIR DRYERS SHALL BE PROVIDED WITH
 ANTIVIBRATION MOUNTINGS PER NFPA 99 SEC. 5.1.3.6.3.7
 (4).
 18) SHT.P002 - DETAIL # 7 - A PRESSURE INDICATOR(S)
 SHALL BE LOCATED DOWNSTREAM OF EACH REGULATOR OR
 IMMEDIATELY DOWNSTREAM OF THE ISOLATING VALVES FOR THE
 REGULATORS PER NFPA 99 SEC. 5.1.3.5.5.1 (3).
 19) SUBMIT RISER DIAGRAMS FOR ALL THE MEDICAL GAS
 PIPING TO BE INSTALLED. WPB AMEND. TO FBC SEC. 107.2.1.
 20) SHT. P002 - DETAIL #7 - THE PRESSURE RELIEF VALVES
 ON THE COMPRESSED AIR SYSTEM SHALL BE VENTED IN
 ACCORDANCE WITH NFPA 99 SEC. 5.1.3.5.6.1 (4).
 21) IDENTIFY THE CONTINUATION POINTS OF THE MEDICAL GAS
 PIPING ON THE REQUESTED MEDICAL GAS RISER DIAGRAMS. WPB
 AMEND. TO FBC SEC. 107.2.1.
 22) THE AREA(S) HOUSING THE VACUUM PUMP AND AIR
 COMPRESSOR SHALL BE VENTILATED PER NFPA 99
 SECS.5.1.3.3.3.3, 5.1.3.6.3.1, 5.1.3.7.1.1.
 23) THE NEW OUTDOOR ENCLOSURE FOR THE MEDICAL GAS SHALL
 BE VENTILATED PER NFPA 99 SEC.5.1.3.3.3.4 (1).
 24) CLEANOUTS ARRE REQUIRED IN THE BASE OF THE
 STORMWATER RISERS. 2017 FBC-PLUMBING SEC.1101.8.
 25) INDICATE ON THE IRRIGATION PLANS IF THERE IS AN
 EXISTING BACKFLOW PRVENTION DEVICE, RAIN SENSOR AND
 SYSTEM CONTROLLER ON THE SYSTEM.
 26) SHT.P400 - THE WATER RISER DIAGRAM SHOWS WATER
 PIPING LINES WITH NO CONNECTION POINTS. IDENTIFY ALL
 CONNECTION POINTS OF THE WATER PIPING SYSTEM TO THE
 EXISTING SYSTEM. WPB AMEND. TO FBC SEC. 107.2.1.
 27) SHT. P400 - SHOW THE BACKFLOW PREVENTER ON THE THE
 ONE INCH WATER LINE TO THE PENTHOUSE. FBC SEC. 107.2.1.
 28) SHT. P401 - THE RISER DIAGRAM INDICATES FIXTURE
 #503.THIS FIXTURE IS NOT LISTED IN THE PLUMBING FIXTURE
 SCHEDULE. CLARIFY.
 29) THE SANITARY RISER SHOWS SANITARY DRAIN LINES AND
 VENTS WITH NO CONNECTION POINTS. IDENTIFY ALL
 CONNECTION POINTS OF THE SANITARY SSYSTEM TO THE
 EXISTING SYSTEM.WPB AMEND. TO FBC SEC. 107.2.1.
 30) THERE ARE NUMEROUS AREAS ON THE SANITARY RISER THAT
 ARE MISSING PIPE SIZES ON THE VENTS AND HORIZONTAL
 DRAINAGE SYSTEM. ENSURE THAT ALL AREAS OF THE SANITARY
 RISER ARE SIZED AND IN COMPLIANCE WITH THE PLUMBING
 CODE.
 31) PLEASE SUBMIT AN EXPANDED SANITARY RISER DIAGRAM
 FOR REVIEW. THERE ARE AREAS WHERE IT IS EXTREMELY
 DIFFICULT TO DETERMINE IF THE DESIGN IS CODE
 COMPLIANT.WPB AMEND. TO FBC SEC. 107.2.1.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-02-28 Cont ID  
Sent By gjohnson Date 2019-02-28 Time 14:11 Rev Time 0.00
Received By gjohnson Date 2019-02-26 Time 15:05 Sent To  
Notes
2019-02-28 14:11:061ST REVIEW: 18091284
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1. TEMPERED WATER SHALL BE DELIVERED FROM LAVATORIES
 AND GROUP WASH FIXTURES LOCATED IN PUBLIC TOILET
 FACILITIES PROVIDED FOR CUSTOMERS, PATRONS AND
 VISITORS. TEMPERED WATER SHALL BE DELIVERED THROUGH AN
 APPROVED WATER-TEMPERATURE LIMITING DEVICE THAT
 CONFORMS TO ASSE 1070 OR CSA B125.3.PER FBC PL 416.5
  
 2. ON THE STORM ISOMETRIC PLEASE SHOW THE SQFT AND THE
 SLOPE OF THE PIPING. PER WPB AMEND TO FBC 107.2.1
  
 3. FOR CLARITY PLEASE SEPARATE THE STORM AND THE
 SANITARY ISOMETRIC DRAWINGS AND REMOVE FIXTURES PLEASE
 USE ABBREVIATIONS FOR IDENTIFICATION. PER WPB AMEND TO
 FBC 107.2.1
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2019-10-23 Cont ID  
Sent By dbattles Date 2019-10-23 Time 08:56 Rev Time 0.00
Received By dbattles Date 2019-10-23 Time 08:56 Sent To  
Notes
2019-10-23 08:56:17OK - STANDING SEAM PER NOA 17-0808.06
  
 PROVISO:
 MODIFIED BITUMEN 17-1221.10 - FLAT ROOF PENDING
 SELECTING SYSTEM
 PROVIDE ENGINEERING IF APPLICABLE BASED ON FLAT ROOF
 SYSTEM SELECTION.
 OK - 17-1227.04 ROOF EDGE
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2019-09-24 Cont ID  
Sent By jwitmer Date 2019-09-24 Time 13:26 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2019-09-24 13:27:49SEE BUILDING COMMENTS FOR ROOFING COMMENTS.
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2019-06-27 Cont ID  
Sent By dbattles Date 2019-06-27 Time 16:10 Rev Time 0.00
Received By dbattles Date 2019-06-27 Time 15:52 Sent To  
Notes
2019-06-27 16:10:04OK-STANDING SEAM PER NOA 17-0808.06
 FLAT ROOF PENDING SELECTING SYSTEM (SEE 2ND ROUND BLDG
 COMMENTS)

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2019-10-23 Cont ID  
Sent By dbattles Date 2019-10-23 Time 09:04 Rev Time 0.00
Received By dbattles Date 2019-10-23 Time 09:04 Sent To  
Notes
2019-09-13 15:09:48ELECTRICAL SHEETS OK.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2019-07-17 Cont ID  
Sent By jpearson Date 2019-07-17 Time 12:34 Rev Time 0.00
Received By jpearson Date 2019-07-14 Time 09:48 Sent To  
Notes
2019-07-17 12:33:59ELECTRICAL SHEETS: PER THE WPB AMENDMENTS TO THE FBC,
 EACH SHEET OF PLAN IS REQUIRED TO BE SIGNED AND SEALED
 BY THE PERSON RESPONSIBLE FOR THE DESIGN. THE DIGITAL
 SIGNATURE MUST INCLUDE THE STATEMENT "SIGNED AND
 SEALED" AS PER FAC 61G15-23.004. PROVIDE CORRECTION.
 WPB FBC 107.1; FS 471/481
  
2019-07-14 09:49:29SIGNATURE OK ON PLUMBING AND MEDICAL GAS SHEETS. TKL.
2019-06-27 16:22:25OK - A SHEETS
 OK - S SHEETS
 ANY NEW SHEETS WILL NEED TO BE DIGITALLY SIGNED.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2019-03-18 Cont ID  
Sent By shill Date 2019-03-18 Time 16:56 Rev Time 0.00
Received By shill Date 2019-03-18 Time 16:56 Sent To  
Notes
2019-03-18 16:56:43ALL PLAN PAGES OK - NEW SHEETS SUBMITTED 2ND REVIEW
 REQUIRE VERIFICATION
 [email protected], 561-805-6724
  
2019-02-22 10:02:53ELECTRICAL SHEETS - OK

Review Stop THRESHOLD THRESHOLD INSPECTOR DOCUMENTS
Rev No 3 Status P Date 2019-10-23 Cont ID  
Sent By dbattles Date 2019-10-23 Time 10:31 Rev Time 0.00
Received By dbattles Date 2019-10-23 Time 09:04 Sent To  
Notes
2019-10-23 10:34:41PROVISO:
 PROVIDE 3 ORIGINAL THRESHOLD AGREEMENTS TO DEVELOPMENT
 SERVICES OFFICE.
 ALSO, PROVIDE RESUME FOR CHRISTIAN STEPUTAT.
  
 CITY OF WEST PALM BEACH, BUILDING DIVISION, 1ST FLOOR
 401 CLEMATIS ST, WEST PALM BEACH, FL 33401
 561-822-2222
  

Review Stop THRESHOLD THRESHOLD INSPECTOR DOCUMENTS
Rev No 2 Status F Date 2019-09-24 Cont ID  
Sent By jwitmer Date 2019-09-24 Time 13:24 Rev Time 0.00
Received By jwitmer Date 2019-09-23 Time 06:04 Sent To  
Notes
2019-09-24 13:26:31WE ARE STILL WAITING FOR THE INTERESTED PARTIES TO
 SUBMIT THE DOCUMENTS FOR A RESIDENT INSPECTOR.
 FORMS ARE TO BE E-MAILED TO : [email protected] SENT AT
 2:09 PM 02/19/2019.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop THRESHOLD THRESHOLD INSPECTOR DOCUMENTS
Rev No 1 Status F Date 2019-06-27 Cont ID  
Sent By dbattles Date 2019-06-27 Time 16:10 Rev Time 0.00
Received By dbattles Date 2019-06-27 Time 15:52 Sent To  
Notes
2019-06-27 16:11:00IN PROGRESS
 PLEASE SEND RESIDENT INSPECTOR AGREEMENT (STARTS ON
 PAGE 9) VIA E-MAIL TO [email protected]. ALSO, INCLUDE
 RESUMES FOR ALL INSPECTORS THAT MAY BE ON-SITE.
 UPON APPROVAL BY CHIEF BUILDING INSPECTOR, THREE
 ORIGINAL COPIES WILL BE REQUESTED.
  

Review Stop Z ZONING
Rev No 5 Status P Date 2019-10-31 Cont ID  
Sent By ajones Date 2019-10-31 Time 15:11 Rev Time 0.00
Received By ajones Date 2019-10-31 Time 15:11 Sent To  
Notes
2019-10-31 15:14:2310/31/19- PASSED BASED ON THE SUBMITTIAL OF A LANDSCAPE
 PERMIT (19101646) ON OCTOBER 31, 2019.
  
  
 ANGELLA VANN, AICP
 561-822-1441
 [email protected]

Review Stop Z ZONING
Rev No 4 Status F Date 2019-10-30 Cont ID  
Sent By eschneid Date 2019-10-30 Time 16:36 Rev Time 0.50
Received By eschneid Date 2019-10-30 Time 16:00 Sent To PC
Notes
2019-10-30 16:37:36FAILED
  
 PROVIDE WRITTEN RESPONSES.
  
 1) UPDATED COMMENT: THANK YOU FOR SUBMITTING THE TREE
 ALTERATION PERMIT APPLICATION. THE CITY?S LANDSCAPE
 PLANNER HAS REVIEWED THE APPLICATION AND REQUIRES THE
 SUBMITTAL OF A LANDSCAPE PERMIT PRIOR TO THE CITY
 ISSUANCE OF THE TREE ALTERATION PERMIT. ONCE THE TREE
 ALTERATION PERMIT IS ISSUED, ZONING CAN APPROVE THE
 PLANS, WHICH INCLUDE THE LANDSCAPE REMOVAL SHOWN ON THE
 DEMOLITION PLANS.
  
 2) THE FOLLOWING SEPARATE PERMITS, WITH PLANS, ARE
 REQUIRED:
  
 A. THE JOB SIGN AND ALL EXTERIOR BUILDING SIGNAGE.
 B. PARKING LOT AND STRIPING.
 C. LANDSCAPE.
 D. IRRIGATION.
 E. BICYCLE RACKS AND PADS.
 F. ANY WORK AT THE OXYGEN PARK, TO INCLUDE SCREEN WALL
 AND RELOCATED TANKS.
  
 3) PLEASE NOTE THAT PRIOR TO THE FINAL INSPECTION TO
 ALLOW OCCUPANCY OF THE EXPANDED EMERGENCY ROOM
 FACILITIES, DIRECTIONAL (WAYFINDING) SIGNS, TO DIRECT
 VEHICLES TO GET FROM THE SOUTH SIDE OF THE CAMPUS TO
 THE NORTH SIDE VIA THE INTERNAL RING ROAD, MUST BE
 INSTALLED SUBJECT TO PLANS APPROVED AS PART OF A MINOR
 PLANNED DEVELOPMENT AMENDMENT SUBMITTED TO THE PLANNING
 DIVISION.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  

Review Stop Z ZONING
Rev No 3 Status F Date 2019-09-25 Cont ID  
Sent By eschneid Date 2019-09-25 Time 10:42 Rev Time 0.75
Received By eschneid Date 2019-09-25 Time 09:34 Sent To  
Notes
2019-09-25 10:42:38FAILED
  
 PROVIDE WRITTEN RESPONSES.
  
 1) REPEAT COMMENT: THE DEMOLITION PERMIT SHOWS THE
 REMOVAL OF TREES AND LANDSCAPE. PRIOR TO ZONING
 APPROVAL OF THIS PERMIT, A TREE ALTERATION PERMIT MUST
 BE SUBMITTED TO AND APPROVED BY THE PLANNING DIVISION.
  
 2) THE FOLLOWING SEPARATE PERMITS, WITH PLANS, ARE
 REQUIRED:
  
 A. THE JOB SIGN AND ALL EXTERIOR BUILDING SIGNAGE.
 B. PARKING LOT AND STRIPING.
 C. LANDSCAPE.
 D. IRRIGATION.
 E. BICYCLE RACKS AND PADS.
 F. ANY WORK AT THE OXYGEN PARK, TO INCLUDE SCREEN WALL
 AND RELOCATED TANKS.
  
 3) PLEASE NOTE THAT PRIOR TO THE FINAL INSPECTION TO
 ALLOW OCCUPANCY OF THE EXPANDED EMERGENCY ROOM
 FACILITIES, DIRECTIONAL (WAYFINDING) SIGNS, TO DIRECT
 VEHICLES TO GET FROM THE SOUTH SIDE OF THE CAMPUS TO
 THE NORTH SIDE VIA THE INTERNAL RING ROAD, MUST BE
 INSTALLED SUBJECT TO PLANS APPROVED AS PART OF A MINOR
 PLANNED DEVELOPMENT AMENDMENT SUBMITTED TO THE PLANNING
 DIVISION.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  

Review Stop Z ZONING
Rev No 2 Status F Date 2019-07-24 Cont ID  
Sent By eschneid Date 2019-07-24 Time 14:44 Rev Time 4.00
Received By eschneid Date 2019-07-24 Time 08:40 Sent To  
Notes
2019-07-24 14:45:18FAILED
  
 PROVIDE WRITTEN RESPONSES.
  
 1) REPEAT COMMENT: THE SCOPE OF WORK INCLUDES WORK ON
 THE ADJACENT OFFICE BUILDING FROM WHEN THE COVER
 BETWEEN THE BUILDINGS IS REMOVED. THE OFFICE BUILDING
 IS ON A SEPARATE PARCEL, WITH DIFFERENT OWNER, SO
 SEPARATE PERMIT(S) FOR THAT WORK IS REQUIRED. --- NO
 PERMIT FOR THE DEMOLITION OF THE COVER AND RESTORATION
 OF THE BUILDING ON THE PARCEL WITH THE ADDRESS OF 2151
 45TH STREET HAS BEEN SUBMITTED. ZONING WILL NOT APPROVE
 THIS PERMIT UNTIL THE DEMOLITION PERMIT(S) FOR 2151
 45TH STREET HAVE BEEN SUBMITTED AND APPROVED.
  
 2) REPEAT COMMENT: PROVIDE THE SETBACK DIMENSION FROM
 THE EASTERN PROPERTY LINE TO THE BUILDING EXPANSION ON
 THE DRAWINGS. --- THE RESPONSE COMMENT SAYS THIS WAS
 DONE, BUT THE SETBACK DIMENSIONS DO NOT APPEAR ON
 SHEETS C301 OR C302. THERE IS A BUBBLED AREA ON EACH
 SHEET THAT LOOKS LIKE IT ATTEMPTS TO ADDRESS THE
 COMMENT, BUT IS MISSING THE DIMENSION LINES.
  
 3) REPEAT COMMENT: THE EXTERIOR BUILDING WALLS SHOW THE
 INSTALLATION OF WALL MOUNTED LIGHT FIXTURES. PLEASE
 PROVIDE THE PHOTOMETRIC DETAILS TO VERIFY THAT THEY DO
 NOT EXCEED 1 FOOT CANDLE AT THE EAST PROPERTY LINE. ---
 THE RESPONSE STATES THAT SHEET E111 WAS ADDED TO THE
 PLAN SET, BUT ZONING STAFF IS UNABLE TO LOCATE THE
 SHEET.
  
 4) THE FOLLOWING SHEETS HAVE BEEN REMOVED AND NEED TO
 BE SUBMITTED AS PART OF SEPARATE PERMIT APPLICATIONS AS
 THEY ARE NOT PART OF THE BUILDING EXPANSION. DO NOT
 RESUBMIT THESE PLANS WITH THIS PERMIT!
  
 A. LANDSCAPE
  
 ALL THE CAMPUS TREE PLAN AND LANDSCAPE PLAN SHEETS,
 INCLUDING THE IRRIGATION SHEETS
  
 B. STRIPING
  
 024 C002 - ENABLING PLAN.PDF
  
 C. FENCE PERMIT - OXYGEN PARK SCREEN WALL --- PLEASE
 NOTE THAT THE RECENT REVIEW OF THE BEHAVIORAL HEALTH
 EXPANSION REQUEST VERIFIED THAT THE REVISED OXYGEN
 PARK, AS SHOWN, ENCROACHES INTO THE DRIVE AISLE AND
 REDUCES THE WIDTH SO THAT TWO-WAY TRAFFIC NO LONGER
 FUNCTIONS. THIS AREA IS BEING REDONE AS PART OF THE
 BEHAVIORAL HEATH EXPANSION. ALL WORK, TO INCLUDE THE
 DEMOLITION REQUIRES A SEPARATE PERMIT.
  
 061 A477 - OXYGEN PARK SCREEN WALL.PDF
  
 5) REPEAT COMMENT: THE DEMOLITION PERMIT SHOWS THE
 REMOVAL OF TREES AND LANDSCAPE. PRIOR TO ZONING
 APPROVAL OF THIS PERMIT, A TREE ALTERATION PERMIT MUST
 BE SUBMITTED TO AND APPROVED BY THE PLANNING DIVISION.
  
 6) THE FOLLOWING SEPARATE PERMITS, WITH PLANS, ARE
 REQUIRED:
  
 A. THE JOB SIGN AND ALL EXTERIOR BUILDING SIGNAGE.
 B. PARKING LOT AND STRIPING.
 C. LANDSCAPE.
 D. IRRIGATION.
 E. BICYCLE RACKS AND PADS.
 F. ANY WORK AT THE OXYGEN PARK, TO INCLUDE SCREEN WALL
 AND RELOCATED TANKS.
  
 7) PLEASE NOTE THAT PRIOR TO THE FINAL INSPECTION TO
 ALLOW OCCUPANCY OF THE EXPANDED EMERGENCY ROOM
 FACILITIES, DIRECTIONAL (WAYFINDING) SIGNS, TO DIRECT
 VEHICLES TO GET FROM THE SOUTH SIDE OF THE CAMPUS TO
 THE NORTH SIDE VIA THE INTERNAL RING ROAD, MUST BE
 INSTALLED SUBJECT TO PLANS APPROVED AS PART OF A MINOR
 PLANNED DEVELOPMENT AMENDMENT SUBMITTED TO THE PLANNING
 DIVISION.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  

Review Stop Z ZONING
Rev No 1 Status F Date 2019-03-15 Cont ID  
Sent By eschneid Date 2019-03-15 Time 14:01 Rev Time 6.00
Received By eschneid Date 2019-03-14 Time 09:55 Sent To  
Notes
2019-03-15 14:22:53FAILED
  
 PROVIDE WRITTEN RESPONSES.
  
 1) THE SCOPE OF WORK INCLUDES WORK ON THE ADJACENT
 OFFICE BUILDING FROM WHEN THE COVER BETWEEN THE
 BUILDINGS IS REMOVED. THE OFFICE BUILDING IS ON A
 SEPARATE PARCEL, WITH DIFFERENT OWNER, SO SEPARATE
 PERMIT(S) FOR THAT WORK IS REQUIRED.
  
 2) THE PERMIT PLANS STATE THAT THERE IS 11,856 SQUARE
 FEET OF NEW CONSTUCTION. THE CITY COMMISSION AND PBC
 TRAFFIC APPROVED A 7,300 SQUARE FOOT EXPANSION. PLEASE
 EXPLAIN WHY THERE IS MORE NEW CONSTRUCTION LISTED.
 NOTE: THE EXTRA SQUARE FOOTAGE MAY REQUIRE CITY
 COMMISSION APPROVAL.
  
 3) PROVIDE THE SETBACK DIMENSION FROM THE EASTERN
 PROPERTY LINE TO THE BUILDING EXPANSION ON THE
 DRAWINGS.
  
 4) PROVIDE A COPY OF THE SURVEY.
  
 5) THE JOB SIGN AND ALL EXTERIOR BUILDING SIGNAGE
 REQUIRES SEPARATE PERMITS WITH PLANS.
  
 6) THE ARCHITECTURAL PLANS DO NOT MATCH THE LAYOUT OF
 THE CIVIL BASE PLANS APPROVED BY THE CITY COMMISSION.
 (EX - THE PROPOSED AMBULANCE CANOPY DOES NOT MATCH THE
 CITY COMMISSION APPROVED PLAN SET). PLEASE CORRECT.
 NOTE: THE AMBULANCE CANOPY DISCREPANCY IS ON THE
 ELEVATIONS, STRUCTURAL PLANS, ROOF PLANS, ETC.
  
 7) THE CIVIL PLANS SUBMITTED WITH THIS APPLICATION ARE
 NOT THE PLANS APPROVED BY THE CITY COMMISSION. PLEASE
 NOTE THAT MANY OF THE CIVIL SHEETS SHOW ITEMS THAT
 REQUIRE SEPARATE PERMITS (EX. THE RECONFIGURATION AND
 STRIPING OF THE PARKING AREA). SEPARATE PERMITS, WITH
 PLANS, WILL NEED TO BE SUBMITTED. MOST, IF NOT ALL, THE
 CIVIL SHEETS ARE NOT NEEDED FOR THE CONSTRUCTION OF THE
 BUILDING EXPANSION COVERED BY THIS PERMIT AND SHOULD BE
 REMOVED.
  
 8) THE EXTERIOR BUILDING WALLS SHOW THE INSTALLATION OF
 WALL MOUNTED LIGHT FIXTURES. PLEASE PROVIDE THE
 PHOTOMETRIC DETAILS TO VERIFY THAT THEY DO NOT EXCEED 1
 FOOT CANDLE AT THE EAST PROPERTY LINE.
  
 9) THE FOLLOWING SHEETS HAVE BEEN REMOVED AND NEED TO
 BE SUBMITTED AS PART OF SEPARATE PERMIT APPLICATIONS:
  
 A. LANDSCAPE
  
 ALL THE CAMPUS TREE PLAN AND LANDSCAPE PLAN SHEETS
  
 B. STRIPING
  
 024 C002 - ENABLING PLAN.PDF
  
 C. FENCE PERMIT - OXYGEN PARK SCREEN WALL
  
 061 A477 - OXYGEN PARK SCREEN WALL.PDF
  
 D. SIGNAGE
  
 200 SC106 - SITE PLAN.PDF
 201 SC107 - SITE PLAN.PDF
  
 10) THE DEMOLITION PERMIT SHOWS THE REMOVAL OF TREES
 AND LANDSCAPE. PRIOR TO ZONING APPROVAL OF THIS PERMIT,
 A TREE ALETERATION PERMIT MUST BE SUBMITTED TO AND
 APPROVED BY THE PLANNING DIVISION.
  
 11) PLEASE NOTE THAT PRIOR TO THE FINAL INSPECTION TO
 ALLOW OCCUPANCY OF THE EXPANDED EMERGENCY ROOM
 FACILITIES, DIRECTIONAL (WAYFINDING) SIGNS, TO DIRECT
 VEHICLES TO GET FROM THE SOUTH SIDE OF THE CAMPUS TO
 THE NORTH SIDE VIA THE INTERNAL RING ROAD, MUST BE