Plan Review Stops For Permit 18091125 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2018-12-17 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-12-17 |
Time |
10:24 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-12-17 |
Time |
09:43 |
Sent To |
E |
|
Notes |
2018-12-17 10:25:06 | SENT TO E (JP) PER SH. CT |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2018-11-27 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-11-27 |
Time |
17:48 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-11-27 |
Time |
17:41 |
Sent To |
|
|
Notes |
2018-11-27 17:48:37 | RESIDENTIAL (R3) BUILDING REVIEW COMMENTS | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | ORIGINAL COMMENT: | | 1- ACCORDING TO CITY RECORDS AND PROPERTY APPRAISER THE | | AREA PROPOSED FOR THE NEW MASTER BATHROOM WAS AN | | UNFINISHED ENCLOSED PORCH. THERE ARE NO CITY RECORDS | | FOR THE RECONFIGURATION OF THIS SPACE. PLANS REQUIRE | | REVIEW BY THE PBC IMPACT FEE OFFICE. CALL (561) | | 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE PLAN SET | | AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE RETURNED | | STAMPED AND WITH A COPY OF THE RECEIPT AS APPLICABLE. | | PLEASE PROVIDE THE MUNICIPAL IMPACT FEE QUESTIONNAIRE | | FORM TO THE PBC IMPACT FEE OFFICE. THE FORM CAN BE | | FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINISTRATION | | /PDF/IMPACT-FEES/FORMS/QUESTIONNAIRE.PDF | | | | RESPONSE: | | NEED COPY OF THE PAID RECEIPT. ($236.59 IS DUE). | | | | | | ORIGINAL COMMENT: | | 2- PLANS SHOW REMOVAL OF SOME WINDOWS IN THE MASTER | | BEDROOM. SPECIFY TYPE AND SIZE OF WINDOWS TO BE REMOVED | | AND REMAINING WIDOWS TO VERIFY COMPLIANCE WITH THE | | EGRESS REQUIREMENTS AS REQUIRED BY SEC. 702.5 | | FBC-EXISTING BUILDING. | | | | RESPONSE: | | TYPE AND SIZE OF REMAINING WINDOWS WERE NOT SPECIFIED | | ON PLANS AS REQUESTED. UNABLE TO VERIFY EGRESS | | COMPLIANCE. | | | | | | | | NOTE: | | MECHANICAL AND PLUMBING WERE APPROVED ON PREVIOUS | | REVIEW. ONE SET OF THE APPROVED AND STAMPED MECHANICAL | | AND PLUMBING PLANS WAS REMOVED AND NOT RESUBMITTED. | | NEED TO RESUBMIT THOSE PLANS OR NEW PLANS ARE REQUIRED | | FOR RE-STAMPING. | | | | | | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | COMMENT TO HELP EXPEDITE THE REVIEW PROCESS. | | | | ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD | | DRAWING. SUBMIT OLD DRAWINGS FOR REFERENCE OF ALREADY | | REVIEWED DRAWINGS. DO NOT STAPLE OLD DRAWINGS TO PLANS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2018-11-08 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-11-08 |
Time |
18:26 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-11-08 |
Time |
17:37 |
Sent To |
|
|
Notes |
2018-11-08 18:26:24 | RESIDENTIAL (R3) BUILDING REVIEW COMMENTS | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | 1- ACCORDING TO CITY RECORDS AND PROPERTY APPRAISER THE | | AREA PROPOSED FOR THE NEW MASTER BATHROOM WAS AN | | UNFINISHED ENCLOSED PORCH. THERE ARE NO CITY RECORDS | | FOR THE RECONFIGURATION OF THIS SPACE. PLANS REQUIRE | | REVIEW BY THE PBC IMPACT FEE OFFICE. CALL (561) | | 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE PLAN SET | | AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE RETURNED | | STAMPED AND WITH A COPY OF THE RECEIPT AS APPLICABLE. | | PLEASE PROVIDE THE MUNICIPAL IMPACT FEE QUESTIONNAIRE | | FORM TO THE PBC IMPACT FEE OFFICE. THE FORM CAN BE | | FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINISTRATION | | /PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | 2- PLANS SHOW REMOVAL OF SOME WINDOWS IN THE MASTER | | BEDROOM. SPECIFY TYPE AND SIZE OF WINDOWS TO BE REMOVED | | AND REMAINING WIDOWS TO VERIFY COMPLIANCE WITH THE | | EGRESS REQUIREMENTS AS REQUIRED BY SEC. 702.5 | | FBC-EXISTING BUILDING. | | | | 3- A)PROVIDE COMPLETE IN-FILL FRAMING DETAIL FOR | | EXTERIOR WALL THAT MATCHES PROPOSED WORK. CLEARLY | | SPECIFY ALL FRAMING MEMBERS AND ALL CONNECTORS (TOP AND | | BOTTOM). SEC. R301.1 FBC-RESIDENTIAL. | | | | B)NEED TO SPECIFY 2 LAYERS OF WATER RESISTIVE BARRIERS | | AS REQUIRED BY SEC. R703.7.3 WATER-RESISTIVE BARRIERS. | | | | 4- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS, | | CONTRACTOR'S OVERHEAD AND PROFIT AND DESIGN | | PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY | | AMENDMENTS. UPDATE VALUATION OR PROVIDE COPY OF SIGNED | | CONTRACT. | | | | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | COMMENT TO HELP EXPEDITE THE REVIEW PROCESS. | | | | ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD | | DRAWING. SUBMIT OLD DRAWINGS FOR REFERENCE OF ALREADY | | REVIEWED DRAWINGS. DO NOT STAPLE OLD DRAWINGS TO PLANS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2018-12-17 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-12-17 |
Time |
12:00 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-12-17 |
Time |
12:00 |
Sent To |
HIST |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2018-11-26 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-11-27 |
Time |
18:53 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-11-26 |
Time |
11:02 |
Sent To |
B |
|
Notes |
2018-11-26 11:02:35 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | 1. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS | | IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. FBC 109.3 | | (NOT PROVIDED.) | | 2. CORRECTED. | | 3. CORRECTED. | | 4. CORRECTED. | | 5. CORRECTED. | | 6. CORRECTED. | | 7. CORRECTED. | | 8. PROVIDE ACCURATE LOAD CALCULATION BASED ON FORMAT | | SPECIFIED IN THE FLORIDA BUILDING CODE RESIDENTIAL. FBC | | RE E3602.2 (LOAD CALCULATION PROVIDED DOES NOT INCLUDE | | THE POOL/CABANA LOADS. PROVIDE CORRECTION.) | | 9. CORRECTED. | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2018-10-07 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-10-07 |
Time |
16:48 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-10-07 |
Time |
16:48 |
Sent To |
|
|
Notes |
2018-10-07 16:48:49 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS | | IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. FBC 109.3 | | 2. NOTE 2 FOR AFCI PROTECTION SHOWN IN NOT CODE | | COMPLIANT. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. THIS | | INCLUDES LIGHTING AND POWER OUTLETS AND RECEPTACLES. | | SOME AREAS REQUIRE BOTH AFCI AND GFCI PROTECTION. | | PROVIDE CORRECTION. NEC 210.8, 210.12; FBC RE E3902; | | FBC EX 607.1.1 OR 801.1, 801.2, OR 901.2 AS APPLICABLE. | | 3. NOTE 4 STATES THAT RECEPTACLES SHALL BE TAMPER | | RESISTANT PER NEC 406.11. THIS CODE SECTION DOES NOT | | APPLY TO TAMPER RESISTANT RECEPTACLES. PROVIDE | | CORRECTION. NEC 406.12; FBC RE E4002.14 | | 4. RISER DIAGRAM SHOWS A FEED FROM THE METER TO THE | | INTERIOR PANEL WHICH IS LOCATED IN THE LAUNDRY ROOM. | | CONDUCTORS THAT ARE NOT PROTECTED BY A MAIN BREAKER OR | | DISCONNECT ARE NOT PERMITTED TO RUN THROUGH THE HOUSE | | IN THIS FASHION. PROVIDE EITHER A MAIN ON THE OUTSIDE | | OF THE HOME, OR INSTALL THE CONDUCTORS UNDER THE SLAB. | | IF CONDUCTORS ARE INSTALLED UNDER THE SLAB, THEN THERE | | SHOULD NOT BE AN EQUIPMENT GROUNDING CONDUCTOR IN THIS | | CONDUIT. PROVIDE CORRECTIONS. NEC 230.70, 250.6; FBC RE | | E3601.6 | | 5. IT APPEARS THAT PANEL A IS FED FROM THE METER | | LOCATED ON A SEPARATE STRUCTURE (GUEST HOUSE). PROVIDE | | GROUNDING ELECTRODE SYSTEM AS REQUIRED FOR A BUILDING | | OR STRUCTURE SUPPLIED BY A FEEDER OR BRANCH CIRCUIT. | | NEC 250.32; FBC RE3607.3 | | 6. RECEPTACLE OUTLETS INSTALLED IN LAUNDRY AREAS SHALL | | HAVE GFCI PROTECTION. PROVIDE CORRECTION. NEC | | 210.8(A)(9); FBC RE E3902.9 | | 7. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC | | 210.8(D); FBC RE E3902.10 | | 8. PROVIDE ACCURATE LOAD CALCULATION BASED ON FORMAT | | SPECIFIED IN THE FLORIDA BUILDING CODE RESIDENTIAL. FBC | | RE E3602.2 | | 9. CIRCUIT 21 SHOWS THE DINING ROOM RECEPTACLE CIRCUIT | | ON 14 GAUGE WIRE AND A 15 AMP BREAKER. PROVIDE | | CORRECTION. NEC 210.52(B)(2); FBC RE E3703.2 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2018-10-18 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2018-10-18 |
Time |
16:10 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2018-10-18 |
Time |
16:08 |
Sent To |
|
|
Notes |
2018-10-18 16:10:36 | REQUIREMENT FOR GAS IS ON THE PLAN. A REVIEW HAS NOT | | BEEN MADE AT THIS TIME. APPLICATION FOR GAS PERMIT MUST | | BE SUBMITTED ALONG WITH PLANS COMPLYING WITH THE | | FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | | | JERALD SMITH | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | EMAIL [email protected] | | PHONE 561-805-6715 | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2018-12-20 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2018-12-20 |
Time |
16:26 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2018-12-20 |
Time |
16:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2018-11-13 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2018-11-13 |
Time |
11:43 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2018-11-13 |
Time |
11:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2018-12-20 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2018-12-20 |
Time |
16:54 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2018-12-05 |
Time |
15:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-11-27 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-11-27 |
Time |
18:52 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-11-21 |
Time |
16:17 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-11-21 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2018-11-21 |
Time |
16:16 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2018-09-25 |
Time |
10:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
3 |
Status |
P |
Date |
2018-12-17 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-12-17 |
Time |
10:12 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-12-17 |
Time |
10:12 |
Sent To |
|
|
Notes |
2018-12-17 10:14:09 | PALM BEACH COUNTY IMPACT FEES $236.59. | | MU-2018-038702-0000. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
F |
Date |
2018-11-27 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-11-27 |
Time |
18:52 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-11-27 |
Time |
18:52 |
Sent To |
|
|
Notes |
2018-11-27 18:52:48 | ORIGINAL COMMENT: | | 1- ACCORDING TO CITY RECORDS AND PROPERTY APPRAISER THE | | AREA PROPOSED FOR THE NEW MASTER BATHROOM WAS AN | | UNFINISHED ENCLOSED PORCH. THERE ARE NO CITY RECORDS | | FOR THE RECONFIGURATION OF THIS SPACE. PLANS REQUIRE | | REVIEW BY THE PBC IMPACT FEE OFFICE. CALL (561) | | 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE PLAN SET | | AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE RETURNED | | STAMPED AND WITH A COPY OF THE RECEIPT AS APPLICABLE. | | PLEASE PROVIDE THE MUNICIPAL IMPACT FEE QUESTIONNAIRE | | FORM TO THE PBC IMPACT FEE OFFICE. THE FORM CAN BE | | FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINISTRATION | | /PDF/IMPACT-FEES/FORMS/QUESTIONNAIRE.PDF | | | | RESPONSE: | | NEED COPY OF THE PAID RECEIPT. ($236.59 IS DUE). |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2018-11-08 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2018-11-08 |
Time |
18:27 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2018-11-08 |
Time |
18:26 |
Sent To |
|
|
Notes |
2018-11-08 18:27:27 | 1- ACCORDING TO CITY RECORDS AND PROPERTY APPRAISER THE | | AREA PROPOSED FOR THE NEW MASTER BATHROOM WAS AN | | UNFINISHED ENCLOSED PORCH. THERE ARE NO CITY RECORDS | | FOR THE RECONFIGURATION OF THIS SPACE. PLANS REQUIRE | | REVIEW BY THE PBC IMPACT FEE OFFICE. CALL (561) | | 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE PLAN SET | | AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE RETURNED | | STAMPED AND WITH A COPY OF THE RECEIPT AS APPLICABLE. | | PLEASE PROVIDE THE MUNICIPAL IMPACT FEE QUESTIONNAIRE | | FORM TO THE PBC IMPACT FEE OFFICE. THE FORM CAN BE | | FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINISTRATION | | /PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2018-10-23 |
|
|
Cont ID |
|
Sent By |
cmontell |
Date |
2018-10-23 |
Time |
10:07 |
Rev Time |
0.00 |
Received By |
cmontell |
Date |
2018-10-23 |
Time |
09:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2018-10-18 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2018-10-18 |
Time |
16:07 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2018-10-18 |
Time |
16:07 |
Sent To |
|
|
Notes |
2018-10-18 16:07:20 | PLUMBING COMMENTS: APPROVED | | | | PROVISO | | 1. TUB/SHOWER CONTROL VALVE(S) SHALL BE PRESSURE | | BALANCED PB, THERMOSTATIC MIXING (TM) OR COMBINATION | | PB/TM VALVE TYPES WITH HIGH TEMPERATURE LIMITING STOP. | | FBC RES P2708.4 | | 2. PROVIDE WATER HAMMER ARRESTORS AT WATER SUPPLIES TO | | ICE LINE, DISHWASHER AND CLOTHES WASHER. FBC RES | | P2903.5 | | 3. THE VALVES FOR THE STACKABLE WASHING MACHINE(S) | | SHALL BE ACCESSIBLE. FBC RES P2903.9.3 | | 4. P3105.1 DISTANCE OF TRAP FROM VENT EXCEPT FOR WATER | | CLOSETS SHALL COMPLY WITH THE REQUIREMENTS SET FORTH IN | | TABLE P3105.1. | | 5. HAND HELD SHOWER IF FURNISHED, REQUIRES AN | | ATMOSPHERIC VACUUM BREAKER AT SHOWER ARM OUTLET. FBC | | RES P2708.5 | | | | JERALD SMITH | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | EMAIL [email protected] | | PHONE 561-805-6715 |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
P |
Date |
2018-12-26 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-12-26 |
Time |
15:45 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-12-26 |
Time |
15:45 |
Sent To |
|
|
Notes |
2018-12-26 15:46:41 | EXPIRED ROOFING PERMIT 18091125. EVALUATION REQUIRED. | | CT |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2018-12-17 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2018-12-17 |
Time |
11:52 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2018-12-17 |
Time |
11:52 |
Sent To |
|
|
Notes |
2018-12-17 11:52:34 | NO ROOFING IS SHOWN HOWEVER THERE IS AN EXPIRED | | RE-ROOFING PERMIT ON THE PROPERTY. | | | | RESOLVE EXPIRE RE-ROOF PERMIT 18091125. | | THE FOLLOWING IS RECOMMENDED: | | A ROOFING CONSULTANT OR CONTRACTOR SHOULD PERFORM A | | DESTRUCTIVE INVESTIGATION TO EVALUATE THE INSTALLED | | SYSTEM, SHEATHING RE-NAILING, UNDERLAYMENT APPLICATION | | AND FINAL CONNECTIONS IN AN ATTEMPT TO EVALUATE/CERTIFY | | THE INSTALLATION OR A NEW ROOF COVERING SHOULD BE | | INSTALLED. A ROOFING PERMIT IS REQUIRED. | | | | STEVEN KENNEDY, CBO | | ASSISTANT BUILDING OFFICIAL | | (561) 805-6710 | | [email protected] | | |
|
|