Plan Review Details - Permit 18091019
Plan Review Stops For Permit 18091019 |
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2018-11-05 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-11-05 |
Time |
15:08 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-11-05 |
Time |
15:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2018-10-08 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-10-08 |
Time |
08:18 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-10-08 |
Time |
08:18 |
Sent To |
I |
|
Notes |
2018-10-08 08:18:08 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE, | | INCLUDE EXISTING AND NEW LOADS TO CONFIRM CAPACITY IS | | ADEQUATE. NEC 215.2, 220, 408.30 | | 2. PROVIDE PVC EXPANSION FITTING PER NEC 352.44. | | 3. ELECTRICAL PLAN IS REQUIRED TO BE SIGNED/SEALED BY A | | DESIGN PROFESSIONAL OR SIGNED BY THE ELECTRICAL | | CONTRACTOR QUALIFIER. PROVIDE CORRECTION. FS | | 471.003(2)(H); 471.025; WPB FBC 107.1 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2018-11-05 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2018-10-23 |
Time |
16:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2018-10-08 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2018-09-26 |
Time |
11:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2018-11-05 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-11-05 |
Time |
15:08 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-11-05 |
Time |
15:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2018-10-08 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-10-08 |
Time |
08:10 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-10-08 |
Time |
08:10 |
Sent To |
|
|
Notes |
2018-10-08 08:10:51 | | | | | ELECTRICAL PLAN IS REQUIRED TO BE SIGNED/SEALED BY A | | DESIGN PROFESSIONAL OR SIGNED BY THE ELECTRICAL | | CONTRACTOR QUALIFIER. PROVIDE CORRECTION. FS | | 471.003(2)(H); 471.025; WPB FBC 107.1 |
|
|
|