Plan Review Stops For Permit 18090657 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2018-12-20 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-12-20 |
Time |
08:48 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-12-20 |
Time |
06:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2018-11-01 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-11-01 |
Time |
14:12 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-11-01 |
Time |
09:25 |
Sent To |
|
|
Notes |
2018-11-01 14:15:59 | BUILDING PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | PLANS EXAMINER, PX3169 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | RESULTS: DENIED | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. ROOF FRAMING - PROPOSED ROOF INDICATES A | | PRE-ENGINEERED ROOF SYSTEM. DETAIL - TYP.RIDGE COPING | | DETAIL ON PLAN PAGE A-4 INDICATES A RIDGE BEAM AND | | RAFTER SYSTEM. PLEASE CLARIFY. | | 2. WALL INSULATION - ENERGY SUBMITTAL REQUIRES R-19. | | PLANS INDICATE R-15. PLEASE CLARIFY. | | 3. CRAWL SPACE INSULATION - ENERGY SUBMITTAL REQUIRED | | R-19. PLANS SHOW NO INSULATION IN CRAWL SPACE. PLEASE | | CLARIFY. | | 4. PROVIDE CRAWL SPACE VENTS PER R408.1 AND ACCESS PER | | R408.4. | | 5. EGRESS WINDOW - PGT-700 SERIES. WINDOW SIZE FROM | | WINDOW SCHEDULE 3' X 5' DOES NOT PROVIDE THE REQUIRED | | EGRESS OPENING PER R310.2.1. SELECT WINDOW FROM PGT | | CATALOG THAT MEETS EGRESS REQUIREMENTS. CHANGE ROUGH | | OPENING DEMENSIONS FOR NEW WINDOW. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | REVIEWED SHEETS DETACHED. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2018-12-20 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-12-20 |
Time |
08:48 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-12-20 |
Time |
08:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2018-11-19 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-10-05 |
Time |
15:52 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-10-05 |
Time |
15:52 |
Sent To |
|
|
Notes |
2018-11-19 12:29:29 | CHANGED VALUE TO $40,000 PER INFORMATION FROM OWNER, | | CHANGED STATUS TO PASS. | | | | | | | 2018-10-05 15:52:09 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | (S) | | | | 1. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS | | IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. FBC 109.3 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2018-12-14 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2018-12-14 |
Time |
11:02 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2018-12-14 |
Time |
11:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
F |
Date |
2018-11-14 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2018-11-14 |
Time |
08:05 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2018-11-14 |
Time |
08:05 |
Sent To |
|
|
Notes |
2018-11-14 08:08:32 | PROPERTY LOCATED IN HISTORIC DISTRICT. ADDITIONS | | REQUIRE SUBMITTAL OF CERTIFICATE OF APPROPRIATENESS | | (COA). INITIAL REVIEW INDICATES PROPOSAL DOES NOT MEET | | DESIGN GUIDELINES. NO PRECEDENCE ON HOUSE OR | | ARCHITECTURAL STYLE FOR ARCH OR DOUBLE FRENCH DOORS | | THAT ARE DRAWN AS SOLID DOORS. QUESTIONS, CONTACT | | FRIEDERIKE MITTNER, CITY HSITORIC PRESERVATION PLANNER | | AT (561) 822-1457 OR [email protected]. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-12-20 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-12-20 |
Time |
08:49 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-11-27 |
Time |
11:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-11-14 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2018-11-14 |
Time |
09:15 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2018-09-14 |
Time |
15:03 |
Sent To |
|
|
Notes |
2018-11-06 08:54:55 | 11/6 TO FM | | | 2018-09-17 15:03:37 | R38 |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2018-12-20 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-12-20 |
Time |
07:01 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-12-20 |
Time |
06:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2018-10-30 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2018-10-30 |
Time |
14:12 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2018-10-30 |
Time |
14:12 |
Sent To |
|
|
Notes |
2018-10-30 14:14:01 | 1ST REVIEW: FBC 2017 6TH ED. RESIDENTIAL | | 1ST REVIEW FBC 2017 EXISTING BUILDING | | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE PLAN AND | | TAKE TO THAT OFFICE FOR REVIEW. PLEASE RETURNED STAMPED | | WITH A COPY OF RECEIPT AS APPLICABLE. | | | | | | STEVEN KENNEDY, CBO | | ASSISTANT BUILDING OFFICIAL | | (561) 805-6710 | | [email protected] | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2018-12-20 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-12-20 |
Time |
08:48 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-12-20 |
Time |
08:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2018-11-01 |
|
|
Cont ID |
|
Sent By |
cmontell |
Date |
2018-10-22 |
Time |
14:17 |
Rev Time |
0.00 |
Received By |
cmontell |
Date |
2018-11-01 |
Time |
14:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2018-12-20 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-12-20 |
Time |
08:49 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-12-20 |
Time |
08:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2018-10-18 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2018-10-18 |
Time |
12:20 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2018-10-18 |
Time |
10:47 |
Sent To |
|
|
Notes |
2018-10-18 12:10:33 | 1ST REVIEW: | | PLUMBING COMMENTS: APPROVED | | | | PROVISO | | 1. TUB/SHOWER CONTROL VALVE(S) SHALL BE PRESSURE | | BALANCED PB,THERMOSTATIC MIXING (TM) OR COMBINATION | | PB/TM VALVE TYPES WITH HIGH TEMPERATURE LIMITING STOP. | | FBC RES P2708.4 | | 2. ACCESSIBLE TEMPERATURE LIMITING DEVICE REQUIRED ON | | HOT WATER TO MASTER BATH BATHTUB(S) IS REQUIRED. FBC | | RES P2713.3 | | 3. PROVIDE WATER HAMMER ARRESTORS AT WATER SUPPLIES TO | | ICE LINE, DISHWASHER AND CLOTHES WASHER PER FBC RES | | P2903.5 | | 4. THE VALVES FOR THE STACKABLE WASHING MACHINE(S) | | SHALL BE ACCESSIBLE. FBC RES P2903.9.3 | | | | ADDITIONAL NOTE: SEE RED LINE MODIFICATION OF SANITARY | | ISOMETRIC TO MAKE CODE COMPLIANT | | | | JERALD SMITH | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | EMAIL [email protected] | | PHONE 561-805-6715 |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
2018-12-20 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-12-20 |
Time |
08:48 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-12-20 |
Time |
07:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2018-12-14 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2018-12-14 |
Time |
11:02 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2018-12-14 |
Time |
11:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2018-11-14 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2018-11-14 |
Time |
08:05 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2018-11-14 |
Time |
08:04 |
Sent To |
|
|
Notes |
2018-11-14 08:05:44 | APPLICATION NEEDS TO REFLECT LOT COVERAGE AND SHOW | | DIMENSIONS FOR REAR SETBACK. |
|
|