Plan Review Stops For Permit 18090589 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2019-05-01 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-05-01 |
Time |
08:03 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-05-01 |
Time |
08:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2018-12-26 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2018-12-26 |
Time |
13:53 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2018-12-26 |
Time |
13:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2018-11-08 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2018-11-08 |
Time |
15:31 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2018-11-08 |
Time |
10:46 |
Sent To |
|
|
Notes |
2018-11-08 15:31:30 | ****CORRECTIONS**** | | W.P.B. PERMIT: 18090589 | | REVIEWED: NOVEMBER 8, 2018 | | | | DYLAN BATTLES | | BUILDING PLANS EXAMINER I | | [email protected] | | 561-805-6718 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC AMENDED = FLORIDA BUILDING CODE,6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC ENERGY = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | [FBC EXISTING 501]STATE THE LEVEL OF ALTERATION FOR | | WORK BEING PERFORMED. | | | | AREA TABULATION: | | IS THE AREA WITH THE SMALL CUBICLES, STORAGE AND GLASS | | FRONT OFFICE PART OF THE EXISTING OFFICE? | | IF NOT, WHAT IS THE CURRENT AREA OF THE OFFICE, THE | | AMOUNT BEING ADDED AND THE TOTAL? | | | | NOTE: | | -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | EACH COMMENT IS BEING ADDRESSED. | | -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW | | OF MATERIALS REQUESTED. | | -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS | | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | NEED "VOID", RENDERING THEM NOT USABLE. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2019-01-02 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-01-02 |
Time |
11:09 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-01-02 |
Time |
08:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2018-09-27 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2018-09-27 |
Time |
14:55 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2018-09-27 |
Time |
13:10 |
Sent To |
|
|
Notes |
2018-09-27 14:55:04 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. ANNOTATE ON PLAN THE REQUIRED REDUNDANT GROUNDING | | FOR RECEPTACLES AND EQUIPMENT IN PATIENT CARE AREAS. | | (EXAM & NST ROOMS). 517.13A&B NEC. | | | | 2. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL | | LOADS. NEC 220; FBC RE E3602.2 | | | | 3. RECEPTACLES WITHIN 6' OF SINKS MUST BE GFCI | | PROTECTED. SOME RECEPTACLES ON PLAN MARKED SFI??? | | 210.8B5 NEC | | | | 4. OCCUPANCY SENSOR REQUIRED IN DR'S OFFICES FBC EC | | C405.2.2.2 | | | | 5. ENGINEERED DRAWING HAS BEEN MARKED WITH PERMANENT | | MARKER SAYING "NO WORK" AND NOT INITIALED BY THE DESIGN | | PROFESSIONAL TO INDICATE HE/SHE MADE THE CHANGE. | | PROVIDE CORRECTION. FS 471.003(2)(H); 471.025; WPB FBC | | 107.1 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | CODES IN EFFECT: | | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2017 6TH ED. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | FRANK GIAQUINTO | | ELECTRICAL INSPECTOR | | ELECTRICAL PLANS EXAMINER | | CITY OF WPB | | [email protected] | | CELL: 561-657-1653 | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2019-05-01 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2019-05-01 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2019-05-01 |
Time |
14:26 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2018-12-14 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2018-12-14 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2018-12-14 |
Time |
14:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2018-09-18 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2018-09-18 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2018-09-17 |
Time |
12:05 |
Sent To |
|
|
Notes |
2018-09-18 10:47:45 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) SHEET A 2 - THERE IS AN INDICATION OF AN AREA OF | | REFUGE AND SEE SHEET A 2.1 FOR MORE INFORMATION. THERE | | IS NO SHEET A 2.1. | | | | PLEASE VIEW AND CORRECT OR JUSTIFY. | | | | | | | | 2) SHEET A 2 - THERE IS AN INDICATION OF THE NUMBER OF | | EXITS AS 2; HOWEVER, THERE IS ONLY ONE EXIT SHOWN ON | | THE PLAN DRAWING. | | | | PER NFPA 101, 2 EXITS ARE REQUIRED. | | | | 39.2.4 NUMBER OF MEANS OF EGRESS. | | 39.2.4.1 MEANS OF EGRESS SHALL COMPLY WITH ALL OF THE | | FOLLOWING, | | EXCEPT AS OTHERWISE PERMITTED BY 39.2.4.2 THROUGH | | 39.2.4.6: | | (1) THE NUMBER OF MEANS OF EGRESS SHALL BE IN | | ACCORDANCE WITH | | 7.4.1.1 AND 7.4.1.3 THROUGH 7.4.1.6. | | (2) NOT LESS THAN TWO SEPARATE EXITS SHALL BE PROVIDED | | ON EVERY | | STORY. | | (3) NOT LESS THAN TWO SEPARATE EXITS SHALL BE | | ACCESSIBLE FROM | | EVERY PART OF EVERY STORY. | | | | PLEASE PROVIDE THE 2ND EXIT PLAN DRAWING. | | | | | | | | | | 3) SHEET A 2 & E - THERE IS AN INDICATION OF THE | | INSTALLATION OF A VOICE EVACUATION ALARM AND E SHEETS | | DO NOT SHOW ANY DEVICES . | | | | ANY WORK ON A FIRE ALARM SYSTEM SHALL BE UNDER SEPARATE | | SHOP DRAWINGS BY CERTIFIED LIFE SAFETY CONTRACOTRS. | | | | PLEASE PROVIDE THE APPLICABLE NOTE . | | | | | | | | | | 4) SHEET A 2 & A 3 - THERE ARE INDICATIONS OF NEW | | DOORS; HOWEVER, THERE IS NO INDICATION OF A DOOR | | SCHEDULE, INCLUDING HARDWARE & LOCKS. | | | | PLEASE PROVIDE A DOOR SCHEDULE . | | | | | | | | 5) SHEET A 4 & E 2.1 - THERE ARE INDICATIONS OF NEW | | CORRIDORS; HOWEVER, THERE ARE NO EXIT SIGNS INDICATED | | IN THE APPLICABLE AREAS. EITHER EXISTING OR NEW. | | | | PLEASE REVIEW AND CORRECT OR JUSTIFY. | | | | | | | | 6) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | | | 7) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2019-05-01 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2019-05-01 |
Time |
16:03 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2019-04-23 |
Time |
14:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-01-10 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2019-01-10 |
Time |
09:08 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2019-01-10 |
Time |
09:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-11-08 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2018-11-08 |
Time |
15:36 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2018-09-13 |
Time |
15:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
N |
Date |
2018-12-26 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2018-12-26 |
Time |
13:54 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2018-12-26 |
Time |
13:54 |
Sent To |
|
|
Notes |
2018-12-26 13:55:11 | NO CHANGE IN OCCUPANCY OR ADDED SPACE. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2018-11-08 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2018-11-08 |
Time |
15:32 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2018-11-08 |
Time |
15:31 |
Sent To |
|
|
Notes |
2018-11-08 15:36:08 | DYLAN BATTLES | | BUILDING PLANS EXAMINER I | | [email protected] | | 561-805-6718 | | | | IS ANY AREA BEING ADDED TO OFFICE SQ FOOTAGE THAT WAS | | PREVIOUSLY A DIFFERENT OCCUPANCY? | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2019-05-01 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2019-05-01 |
Time |
14:11 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2019-05-01 |
Time |
12:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2019-01-07 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2019-01-07 |
Time |
10:41 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2019-01-07 |
Time |
10:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2018-10-23 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-10-23 |
Time |
11:56 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-10-23 |
Time |
11:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2019-04-30 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2019-04-30 |
Time |
15:49 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2019-04-30 |
Time |
15:21 |
Sent To |
|
|
Notes |
2019-04-30 15:50:26 | PROVISO: ADDED CLEAR FLOOR SPACE TO SHT. A-2 AS CALLED | | OUT ON A-1 DETAIL FOR SINK. THUNT |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2019-01-10 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2019-01-10 |
Time |
09:08 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2019-01-10 |
Time |
09:06 |
Sent To |
|
|
Notes |
2019-01-10 09:07:52 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | EDITION | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | FAC= FLORIDA ADMINISTRATIVE CODE | | FS = FLORIDA STATUTES | | | | 2ND REVIEW: | | PLUMBING COMMENTS: DENIED | | | | 1. SECOND REQUEST | | A) RE: PLAN SHEET A2, A3, P0.1, P2.1 & P3.1; THE | | ACCESSIBILITY CODE REQUIRES A MINIMUM OF 1 SINK IN EACH | | TYPE OF ACCESSIBLE ROOM COMPLY WITH FBC ACC 606 PER FBC | | ACC 212.3. PLEASE NOTE THAT THE ARCHITECT HAS NOT | | PROVIDED THIS INFORMATION ON THE PLANS AND NEEDS TO DO | | SO BEFORE THE PLUMBING PERMIT APPLICATION CAN BE | | APPROVED. THE PROVIDED INFORMATION BY THE ARCHITECT | | NEEDS TO INCLUDE SUCH THINGS AS THE DESIGNATED | | ACCESSIBLE ROOM (IE. EXAM RM #4), MILL WORK PLAN AND | | ELEVATION VIEWS, AND POSSIBLY ANOTHER DESIGNATED | | PLUMBING FIXTURE IN THE PLUMBING FIXTURE SCHEDULE. | | 2. PLAN SHEET A2 INDICATES AN EXISTING WATER HEATER IN | | THE EXISTING STORAGE ROOM. P0.1 AND P3.1 INDICATE A NEW | | WATER HEATER. | | A) RESPONSE BY ENGINEER IS THAT THE EXISTING WATER | | HEATER IS TO BE REPLACED WITH A NEW WATER HEATER OF | | LIKE KIND. REQUIRED INFORMATION CONCERNING THIS HAS | | BEEN INCLUDED IN THE PLUMBING FIXTURE SCHEDULE AND | | DETAIL. | | B) ARCHITECT TO REMOVE NOTE ?EXISTING WATER HEATER? AND | | ON PLAN SHEET A2 AND PROVIDE NOTE ?REPLACE EXISTING | | WATER HEATER WITH NEW? PER WPB FBC 107.2.1 | | 3. RE: PLAN SHEET A1; CODE SUMMARY. REFERENCES TO | | FLORIDA ACCESSIBILITY CODE 2014, FBC PLUMBING CODE 2014 | | AND FBC FUEL GAS CODE 2014 SHALL BE CORRECTED TO SHOW | | COMPLIANCE WITH THE 6TH EDITION, 2017 CODE PER WPB FBC | | 107.2.1 | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED "VOID". | | | | | | JERALD SMITH | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | EMAIL [email protected] | | PHONE 561-805-6715 | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2018-10-30 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2018-10-30 |
Time |
15:10 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2018-10-30 |
Time |
15:08 |
Sent To |
|
|
Notes |
2018-10-30 15:10:05 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | EDITION | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | FAC= FLORIDA ADMINISTRATIVE CODE | | FS = FLORIDA STATUTES | | | | 1ST REVIEW: | | PLUMBING COMMENTS: DENIED | | | | 1. RE: PLAN SHEET A2, A3, P0.1, P2.1 & P3.1 & P: THE | | ACCESSIBILITY CODE REQUIRES A MINIMUM OF 1 SINK IN EACH | | TYPE OF ACCESSIBLE ROOM COMPLY WITH FBC ACC 606 PER FBC | | ACC 212.3. PLEASE NOTE THAT THE ARCHITECT HAS NOT | | PROVIDED THIS INFORMATION ON THE PLANS AND NEEDS TO DO | | SO BEFORE THE PLUMBING PERMIT APPLICATION CAN BE | | APPROVED. THE PROVIDED INFORMATION BY THE ARCHITECT | | NEEDS TO INCLUDE SUCH THINGS AS THE DESIGNATED | | ACCESSIBLE ROOM (IE. EXAM RM #4), MILL WORK PLAN AND | | ELEVATION VIEWS, AND POSSIBLY ANOTHER DESIGNATED | | PLUMBING FIXTURE IN THE PLUMBING FIXTURE SCHEDULE. | | 2. PLAN SHEET A2 INDICATES AN EXISTING WATER HEATER IN | | THE EXISTING STORAGE ROOM. P0.1 AND P3.1 INDICATE A NEW | | WATER HEATER. PLEASE CLARIFY ON PLANS. WPB FBC 107.2.1 | | 3. NEW EXAM RMS 17 AND 18 HAVE BEEN REMOVED FROM THE | | SCOPE OF WORK. PLEASE REMOVE THE PIPING SHOWN ON P0.1, | | P2.1 AND P3.1 THAT SERVICES THESE ROOMS OR INDICATE | | NIC.. WPB FBC 107.2.1 | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED "VOID". | | | | | | JERALD SMITH | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | EMAIL [email protected] | | PHONE 561-805-6715 | | | | | | | | 18090589 770 NORTHPOINT PKWY #200 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2018-09-17 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2018-09-17 |
Time |
15:23 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2018-09-17 |
Time |
15:23 |
Sent To |
|
|
Notes |
|
|