Plan Review Details - Permit 18090589
Plan Review Stops For Permit 18090589
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2019-05-01 Cont ID  
Sent By dbattles Date 2019-05-01 Time 08:03 Rev Time 0.00
Received By dbattles Date 2019-05-01 Time 08:03 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2018-12-26 Cont ID  
Sent By dbattles Date 2018-12-26 Time 13:53 Rev Time 0.00
Received By dbattles Date 2018-12-26 Time 13:53 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2018-11-08 Cont ID  
Sent By dbattles Date 2018-11-08 Time 15:31 Rev Time 0.00
Received By dbattles Date 2018-11-08 Time 10:46 Sent To  
Notes
2018-11-08 15:31:30****CORRECTIONS****
 W.P.B. PERMIT: 18090589
 REVIEWED: NOVEMBER 8, 2018
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER I
 [email protected]
 561-805-6718
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC AMENDED = FLORIDA BUILDING CODE,6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC ENERGY = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 [FBC EXISTING 501]STATE THE LEVEL OF ALTERATION FOR
 WORK BEING PERFORMED.
  
 AREA TABULATION:
 IS THE AREA WITH THE SMALL CUBICLES, STORAGE AND GLASS
 FRONT OFFICE PART OF THE EXISTING OFFICE?
 IF NOT, WHAT IS THE CURRENT AREA OF THE OFFICE, THE
 AMOUNT BEING ADDED AND THE TOTAL?
  
 NOTE:
 -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
 -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW
 OF MATERIALS REQUESTED.
 -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS
 OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS)
 SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT
 DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER
 SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID"
 OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS
 APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE
 NEED "VOID", RENDERING THEM NOT USABLE.
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-01-02 Cont ID  
Sent By jpearson Date 2019-01-02 Time 11:09 Rev Time 0.00
Received By jpearson Date 2019-01-02 Time 08:09 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2018-09-27 Cont ID  
Sent By fgiaquin Date 2018-09-27 Time 14:55 Rev Time 0.00
Received By fgiaquin Date 2018-09-27 Time 13:10 Sent To  
Notes
2018-09-27 14:55:04ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. ANNOTATE ON PLAN THE REQUIRED REDUNDANT GROUNDING
 FOR RECEPTACLES AND EQUIPMENT IN PATIENT CARE AREAS.
 (EXAM & NST ROOMS). 517.13A&B NEC.
  
 2. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL
 LOADS. NEC 220; FBC RE E3602.2
  
 3. RECEPTACLES WITHIN 6' OF SINKS MUST BE GFCI
 PROTECTED. SOME RECEPTACLES ON PLAN MARKED SFI???
 210.8B5 NEC
  
 4. OCCUPANCY SENSOR REQUIRED IN DR'S OFFICES FBC EC
 C405.2.2.2
  
 5. ENGINEERED DRAWING HAS BEEN MARKED WITH PERMANENT
 MARKER SAYING "NO WORK" AND NOT INITIALED BY THE DESIGN
 PROFESSIONAL TO INDICATE HE/SHE MADE THE CHANGE.
 PROVIDE CORRECTION. FS 471.003(2)(H); 471.025; WPB FBC
 107.1
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 CODES IN EFFECT:
  
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2017 6TH ED.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 FRANK GIAQUINTO
 ELECTRICAL INSPECTOR
 ELECTRICAL PLANS EXAMINER
 CITY OF WPB
 [email protected]
 CELL: 561-657-1653
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2019-05-01 Cont ID  
Sent By pleduc Date 2019-05-01 Time   Rev Time 0.00
Received By pleduc Date 2019-05-01 Time 14:26 Sent To I
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2018-12-14 Cont ID  
Sent By pleduc Date 2018-12-14 Time   Rev Time 0.00
Received By pleduc Date 2018-12-14 Time 14:22 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2018-09-18 Cont ID  
Sent By pleduc Date 2018-09-18 Time   Rev Time 0.00
Received By pleduc Date 2018-09-17 Time 12:05 Sent To  
Notes
2018-09-18 10:47:45THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 1) SHEET A 2 - THERE IS AN INDICATION OF AN AREA OF
 REFUGE AND SEE SHEET A 2.1 FOR MORE INFORMATION. THERE
 IS NO SHEET A 2.1.
  
 PLEASE VIEW AND CORRECT OR JUSTIFY.
  
  
  
 2) SHEET A 2 - THERE IS AN INDICATION OF THE NUMBER OF
 EXITS AS 2; HOWEVER, THERE IS ONLY ONE EXIT SHOWN ON
 THE PLAN DRAWING.
  
 PER NFPA 101, 2 EXITS ARE REQUIRED.
  
 39.2.4 NUMBER OF MEANS OF EGRESS.
 39.2.4.1 MEANS OF EGRESS SHALL COMPLY WITH ALL OF THE
 FOLLOWING,
 EXCEPT AS OTHERWISE PERMITTED BY 39.2.4.2 THROUGH
 39.2.4.6:
 (1) THE NUMBER OF MEANS OF EGRESS SHALL BE IN
 ACCORDANCE WITH
 7.4.1.1 AND 7.4.1.3 THROUGH 7.4.1.6.
 (2) NOT LESS THAN TWO SEPARATE EXITS SHALL BE PROVIDED
 ON EVERY
 STORY.
 (3) NOT LESS THAN TWO SEPARATE EXITS SHALL BE
 ACCESSIBLE FROM
 EVERY PART OF EVERY STORY.
  
 PLEASE PROVIDE THE 2ND EXIT PLAN DRAWING.
  
  
  
  
 3) SHEET A 2 & E - THERE IS AN INDICATION OF THE
 INSTALLATION OF A VOICE EVACUATION ALARM AND E SHEETS
 DO NOT SHOW ANY DEVICES .
  
 ANY WORK ON A FIRE ALARM SYSTEM SHALL BE UNDER SEPARATE
 SHOP DRAWINGS BY CERTIFIED LIFE SAFETY CONTRACOTRS.
  
 PLEASE PROVIDE THE APPLICABLE NOTE .
  
  
  
  
 4) SHEET A 2 & A 3 - THERE ARE INDICATIONS OF NEW
 DOORS; HOWEVER, THERE IS NO INDICATION OF A DOOR
 SCHEDULE, INCLUDING HARDWARE & LOCKS.
  
 PLEASE PROVIDE A DOOR SCHEDULE .
  
  
  
 5) SHEET A 4 & E 2.1 - THERE ARE INDICATIONS OF NEW
 CORRIDORS; HOWEVER, THERE ARE NO EXIT SIGNS INDICATED
 IN THE APPLICABLE AREAS. EITHER EXISTING OR NEW.
  
 PLEASE REVIEW AND CORRECT OR JUSTIFY.
  
  
  
 6) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
  
 7) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-05-01 Cont ID  
Sent By cpuell Date 2019-05-01 Time 16:03 Rev Time 0.00
Received By cpuell Date 2019-04-23 Time 14:40 Sent To  
Notes
2019-04-29 15:11:06C10

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-01-10 Cont ID  
Sent By jesmith Date 2019-01-10 Time 09:08 Rev Time 0.00
Received By jesmith Date 2019-01-10 Time 09:08 Sent To  
Notes
2018-12-12 14:31:32C08

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2018-11-08 Cont ID  
Sent By dbattles Date 2018-11-08 Time 15:36 Rev Time 0.00
Received By dbattles Date 2018-09-13 Time 15:37 Sent To  
Notes
2018-09-14 15:37:47C30

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status N Date 2018-12-26 Cont ID  
Sent By dbattles Date 2018-12-26 Time 13:54 Rev Time 0.00
Received By dbattles Date 2018-12-26 Time 13:54 Sent To  
Notes
2018-12-26 13:55:11NO CHANGE IN OCCUPANCY OR ADDED SPACE.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2018-11-08 Cont ID  
Sent By dbattles Date 2018-11-08 Time 15:32 Rev Time 0.00
Received By dbattles Date 2018-11-08 Time 15:31 Sent To  
Notes
2018-11-08 15:36:08DYLAN BATTLES
 BUILDING PLANS EXAMINER I
 [email protected]
 561-805-6718
  
 IS ANY AREA BEING ADDED TO OFFICE SQ FOOTAGE THAT WAS
 PREVIOUSLY A DIFFERENT OCCUPANCY?
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2019-05-01 Cont ID  
Sent By ccole Date 2019-05-01 Time 14:11 Rev Time 0.00
Received By ccole Date 2019-05-01 Time 12:29 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2019-01-07 Cont ID  
Sent By ccole Date 2019-01-07 Time 10:41 Rev Time 0.00
Received By ccole Date 2019-01-07 Time 10:41 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2018-10-23 Cont ID  
Sent By ccole Date 2018-10-23 Time 11:56 Rev Time 0.00
Received By ccole Date 2018-10-23 Time 11:56 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2019-04-30 Cont ID  
Sent By thunt Date 2019-04-30 Time 15:49 Rev Time 0.00
Received By thunt Date 2019-04-30 Time 15:21 Sent To  
Notes
2019-04-30 15:50:26PROVISO: ADDED CLEAR FLOOR SPACE TO SHT. A-2 AS CALLED
 OUT ON A-1 DETAIL FOR SINK. THUNT

Review Stop P PLUMBING
Rev No 2 Status F Date 2019-01-10 Cont ID  
Sent By jesmith Date 2019-01-10 Time 09:08 Rev Time 0.00
Received By jesmith Date 2019-01-10 Time 09:06 Sent To  
Notes
2019-01-10 09:07:52CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 2ND REVIEW:
 PLUMBING COMMENTS: DENIED
  
 1. SECOND REQUEST
 A) RE: PLAN SHEET A2, A3, P0.1, P2.1 & P3.1; THE
 ACCESSIBILITY CODE REQUIRES A MINIMUM OF 1 SINK IN EACH
 TYPE OF ACCESSIBLE ROOM COMPLY WITH FBC ACC 606 PER FBC
 ACC 212.3. PLEASE NOTE THAT THE ARCHITECT HAS NOT
 PROVIDED THIS INFORMATION ON THE PLANS AND NEEDS TO DO
 SO BEFORE THE PLUMBING PERMIT APPLICATION CAN BE
 APPROVED. THE PROVIDED INFORMATION BY THE ARCHITECT
 NEEDS TO INCLUDE SUCH THINGS AS THE DESIGNATED
 ACCESSIBLE ROOM (IE. EXAM RM #4), MILL WORK PLAN AND
 ELEVATION VIEWS, AND POSSIBLY ANOTHER DESIGNATED
 PLUMBING FIXTURE IN THE PLUMBING FIXTURE SCHEDULE.
 2. PLAN SHEET A2 INDICATES AN EXISTING WATER HEATER IN
 THE EXISTING STORAGE ROOM. P0.1 AND P3.1 INDICATE A NEW
 WATER HEATER.
 A) RESPONSE BY ENGINEER IS THAT THE EXISTING WATER
 HEATER IS TO BE REPLACED WITH A NEW WATER HEATER OF
 LIKE KIND. REQUIRED INFORMATION CONCERNING THIS HAS
 BEEN INCLUDED IN THE PLUMBING FIXTURE SCHEDULE AND
 DETAIL.
 B) ARCHITECT TO REMOVE NOTE ?EXISTING WATER HEATER? AND
 ON PLAN SHEET A2 AND PROVIDE NOTE ?REPLACE EXISTING
 WATER HEATER WITH NEW? PER WPB FBC 107.2.1
 3. RE: PLAN SHEET A1; CODE SUMMARY. REFERENCES TO
 FLORIDA ACCESSIBILITY CODE 2014, FBC PLUMBING CODE 2014
 AND FBC FUEL GAS CODE 2014 SHALL BE CORRECTED TO SHOW
 COMPLIANCE WITH THE 6TH EDITION, 2017 CODE PER WPB FBC
 107.2.1
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED "VOID".
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2018-10-30 Cont ID  
Sent By jesmith Date 2018-10-30 Time 15:10 Rev Time 0.00
Received By jesmith Date 2018-10-30 Time 15:08 Sent To  
Notes
2018-10-30 15:10:05CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 1ST REVIEW:
 PLUMBING COMMENTS: DENIED
  
 1. RE: PLAN SHEET A2, A3, P0.1, P2.1 & P3.1 & P: THE
 ACCESSIBILITY CODE REQUIRES A MINIMUM OF 1 SINK IN EACH
 TYPE OF ACCESSIBLE ROOM COMPLY WITH FBC ACC 606 PER FBC
 ACC 212.3. PLEASE NOTE THAT THE ARCHITECT HAS NOT
 PROVIDED THIS INFORMATION ON THE PLANS AND NEEDS TO DO
 SO BEFORE THE PLUMBING PERMIT APPLICATION CAN BE
 APPROVED. THE PROVIDED INFORMATION BY THE ARCHITECT
 NEEDS TO INCLUDE SUCH THINGS AS THE DESIGNATED
 ACCESSIBLE ROOM (IE. EXAM RM #4), MILL WORK PLAN AND
 ELEVATION VIEWS, AND POSSIBLY ANOTHER DESIGNATED
 PLUMBING FIXTURE IN THE PLUMBING FIXTURE SCHEDULE.
 2. PLAN SHEET A2 INDICATES AN EXISTING WATER HEATER IN
 THE EXISTING STORAGE ROOM. P0.1 AND P3.1 INDICATE A NEW
 WATER HEATER. PLEASE CLARIFY ON PLANS. WPB FBC 107.2.1
 3. NEW EXAM RMS 17 AND 18 HAVE BEEN REMOVED FROM THE
 SCOPE OF WORK. PLEASE REMOVE THE PIPING SHOWN ON P0.1,
 P2.1 AND P3.1 THAT SERVICES THESE ROOMS OR INDICATE
 NIC.. WPB FBC 107.2.1
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED "VOID".
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715
  
  
  
 18090589 770 NORTHPOINT PKWY #200
  

Review Stop Z ZONING
Rev No 1 Status P Date 2018-09-17 Cont ID  
Sent By ajones Date 2018-09-17 Time 15:23 Rev Time 0.00
Received By ajones Date 2018-09-17 Time 15:23 Sent To  
Notes
***NONE***