Plan Review Stops For Permit 18090558 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2018-12-12 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2018-12-12 |
Time |
12:59 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2018-12-11 |
Time |
16:54 |
Sent To |
|
|
Notes |
2018-12-12 13:00:28 | PROVISOS ADDRESSED AND REMOVED FROM PLAN. CT |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2018-11-14 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-11-14 |
Time |
12:18 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-11-05 |
Time |
07:50 |
Sent To |
|
|
Notes |
2018-11-14 12:26:21 | ****PROVISOS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1. FBC B 1603.1.4, REVISE PLAN TO INCLUDE WIND DESIGN | | CRITERIA, INCLUDING DESIGN PRESSURES FOR THE NEW DOORS. | | | | 2. PRIOR TO INSTALLATION, DOOR ENGINEERING REVIEWED BY | | DESIGNER OF RECORD IS TO BE SUBMITTED AND ISSUED PRIOR | | TO INSTALLATION. A SEPARATE SUBMITTAL HAS BEEN | | GENERATED FOR THE DOOR ENGINEERING TO FACILITATE | | ISSUANCE OF THIS PERMIT. | | | | 3. REVISE THE LIFE SAFETY PLAN; OCCUPANT LOAD IS OVER | | 50 SO REQUIRES TWO REMOTELY LOCATED EXITS. THE THREE | | FRENCH DOORS ARE SHOWN AS NON-EGRESS, BUT ONE IS | | REQUIRED. BUILDING OFFICIAL HAS AGREED TO APPLICANT'S | | PROPOSAL OF DOOR SIGNAGE INDICATING "OPEN" OR "CLOSED" | | AND AGREEMENT THAT THE DOORS WILL REMAIN UNLOCKED AT | | ALL TIMES THAT THE RESTAURANT IS OPEN. | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2018-10-11 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-10-11 |
Time |
06:13 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-10-10 |
Time |
18:25 |
Sent To |
|
|
Notes |
2018-10-11 06:26:13 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1. FBC A 226, 902.1, IT APPEARS THAT THERE ARE TWO | | DINING BAR AREAS; REVISE PLAN TO SHOW COMPLIANCE. BAR | | HEIGHT IS NOT CLEAR, AND NO ACCESSIBLE PORTION SHOWN. | | | | 2. FBC A 227, SALES AND SERVICE A POS AND PICK UP AREA | | IS SHOWN. REVISE PLAN TO SHOW COMPLIANCE. | | | | 3. FBC A TABLE 404.2.41(C), THE TWO BATHROOM DOORS SHOW | | 12" CLEARANCE ON THE PULL SIDE, BUT IT APPEARS THAT 18" | | IS REQUIRED. ALTHOUGH THIS IS EXISTING, PLEASE SEE FBC | | A 202.4. IT APPEARS THAT THERE IS ROOM TO MOVE THE LAV | | AND MAINTAIN ALL REQUIRED CLEAR FLOOR SPACES. NOTE | | THAT, AS INSTALLED, A WHEELCHAIR USER COULD ENTER AND | | USE THE BATHROOM BUT MAY BE UNABLE TO EXIT. | | | | 4. A.04, DOOR SCHEDULE SHOWS "NA" FOR ALL DOORS. FLOOR | | PLAN SHOWS THREE NEW DOUBLE DOORS PROPOSED AS WELL AS | | EXISTING DOORS AND REFERS TO STRUCTURAL DRAWINGS FOR | | THE NEW DOORS. NO STRUCTURAL SHEETS WERE SUBMITTED, | | PLEASE PROVIDE. LIFE SAFETY/FLOOR PLAN SHOULD SHOW THE | | SIZE OF THE NEW DOORS PROPOSED AS WELL AS PROVIDE | | INFORMATION REGARDING EXISTING DOORS, FBC 107, FBC B | | 1609, FBC B CHAPTER 10. | | | | 5. FBC B 1603.1.4, REVISE PLAN TO INCLUDE WIND DESIGN | | CRITERIA, INCLUDING DESIGN PRESSURES FOR THE NEW DOORS. | | | | 6. TO AVOID ANY FIELD CONFLICTS, REVISE THE DOOR | | SCHEDULE TO INCLUDE THE PANIC BARS REQUIRED BY FBC B | | 1010.1.10 (PER FBC EB 801.3. | | | | 7. FLORIDA STATUTE 481, DOCUMENTS PREPARED BY AN | | ARCHITECT AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | SIGNED, SEALED DATED ORIGINALS. AT LEAST ONE PAGE WAS | | SEALED BUT NOT SIGNED AND DATED. PLEASE CONFIRM ALL | | PAGES PRIOR TO RESUBMITTAL. | | | | 8. THIS PERMIT WILL BE ISSUED WITH PROVISO; PRIOR TO | | INSTALLATION, DOOR PRODUCT APPROVALS REVIEWED BY | | DESIGNER OF RECORD ARE TO BE SUBMITTED AND ISSUED PRIOR | | TO REVIEW. ON THE PRODUCT APPROVAL, INDICATE ADA | | THRESHOLD AND PANIC BARS. IF YOU DO NOT AGREE WITH THIS | | PROVISO, CONTACT ME PRIOR TO ISSUANCE. | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2018-11-09 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-11-09 |
Time |
12:50 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-11-09 |
Time |
12:50 |
Sent To |
|
|
Notes |
2018-11-09 12:50:36 | NO CHANGES TO PREVIOUSLY APPROVED PLANS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2018-09-17 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-09-16 |
Time |
15:39 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-09-16 |
Time |
15:39 |
Sent To |
|
|
Notes |
2018-09-17 10:17:52 | CHANGED VALUE TO $85,000 PER EMAIL FROM CONTRACTOR. | | CHANGED STATUS TO PASS. | | | | | | | 2018-09-16 15:38:32 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | (S) | | | | 1. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS | | IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. FBC 109.3 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED "OLD | | SHEETS". | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | | | | | | | |
|
|
Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
Rev No |
1 |
Status |
P |
Date |
2018-11-09 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-11-09 |
Time |
12:57 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-11-09 |
Time |
12:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2018-12-14 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2018-12-14 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2018-12-14 |
Time |
13:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2018-10-24 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2018-10-24 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2018-10-24 |
Time |
11:34 |
Sent To |
|
|
Notes |
2018-10-24 11:38:48 | THE PREVIOUS COMMENTS FROM FIRE DO NOT APPEAR TO BE | | ADDRESSED EITHER IN CLOUD REVISIONS NOR NARRATIVE AND | | ARE RESTATED BELOW. | | | | PLEASE ADDRESS FIRE COMMENTS SPECIFICALLY: | | | | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) SHEET A 03 - THE OCCUPANCY LOAD CALCULATIONS DO NOT | | INDICATE NUMBERS FOR THE KITCHEN OR BAR SERVICE AREA. | | | | PLEASE REVIEW AND PROVIDE DETAILS | | | | | | | | | | 2) THERE ARE NO DIMENSIONS INDICATED TO VERIFY THE | | OCCUPANCY LOAD OF THE SEATING AREA. THE BATHROOMS | | SHOULD NO BE INCLUDED WITH THE SEATING AREA. | | | | ADDITIONALLY, THERE ARE NO DIMENSIONS INDCATED BETWEEN | | THE SEATS OR EACH AISLE TO ENSURE REQUIRED WIDTHS OR | | PASSAGE. | | | | PER NFPA 101, CHAPTER 12 OR 13, NEW OR EXISTING | | ASSEMBLY OCCUPANCIES | | | | 12.2.5.8 AISLES SERVING SEATING AT TABLES. | | | | 12.2.5.8.2* THE WIDTH OF AISLES SERVING SEATING AT | | TABLES SHALL BE | | NOT LESS THAN 44 IN. (1120 MM) WHERE SERVING AN | | OCCUPANT LOAD | | EXCEEDING 50, AND 36 IN. (915 MM) WHERE SERVING AN | | OCCUPANT | | LOAD OF 50 OR FEWER. | | 12.2.5.8.3* WHERE NONFIXED SEATING IS LOCATED BETWEEN A | | TABLE AND | | AN AISLE, THE MEASUREMENT OF REQUIRED CLEAR WIDTH OF | | THE AISLE SHALL | | BE MADE TO A LINE 19 IN. (485 MM), MEASURED | | PERPENDICULARLY TO | | THE EDGE OF THE TABLE, AWAY FROM THE EDGE OF SAID | | TABLE. | | 12.2.5.9 APPROVAL OF LAYOUTS. | | 12.2.5.9.1 WHERE REQUIRED BY THE AUTHORITY HAVING | | JURISDICTION, | | PLANS DRAWN TO SCALE SHOWING THE ARRANGEMENT OF | | FURNISHINGS OR | | EQUIPMENT SHALL BE SUBMITTED TO THE AUTHORITY BY THE | | BUILDING | | OWNER, MANAGER, OR AUTHORIZED AGENT TO SUBSTANTIATE | | CONFORMANCE | | WITH THE PROVISIONS OF 12.2.5. | | 12.2.5.9.2 THE LAYOUT PLANS SHALL CONSTITUTE THE ONLY | | ACCEPTABLE | | ARRANGEMENT, UNLESS ONE OF THE FOLLOWING CRITERIA IS | | MET: | | (1) THE PLANS ARE REVISED. | | (2) ADDITIONAL PLANS ARE SUBMITTED AND APPROVED. | | (3) TEMPORARY DEVIATIONS FROM THE SPECIFICATIONS OF THE | | APPROVED PLANS ARE USED, PROVIDED THAT THE OCCUPANT | | LOAD IS | | NOT INCREASED AND THE INTENT OF 12.2.5.9 IS MAINTAINED. | | | | PLEASE REVIEW AND PROVIDE. | | | | | | | | 3) SHEET A 04 - 8 SEATS ARE INDCATED ON THE FLOOR PLAN | | BY THE LEFT SIDE DOUBLE DOORS. 4 OF THE SEAT ENCROACH | | INTO THE PATH OF EGRESS. | | | | THOSE DOORS ARE NOT REQUIRED TO MEET YOUR EGRESS | | DEMAND; HOWEVER, EITHER THOSE DOOR CAN NOT BE INDICATED | | AS AN EXIT OR THE CHAIRS AND TABLES WILL NEED TO BE | | REMOVED. | | | | PER NFPA 101, CHAPTER 7, MEANS OF EGRESS. | | | | 7.1.10 MEANS OF EGRESS RELIABILITY. | | 7.1.10.1* MAINTENANCE. MEANS OF EGRESS SHALL BE | | CONTINUOUSLY | | MAINTAINED FREE OF ALL OBSTRUCTIONS OR IMPEDIMENTS TO | | FULL INSTANT | | USE IN THE CASE OF FIRE OR OTHER EMERGENCY. | | | | | | | | 4) SHEET A 06 - THERE IS KITCHEN COOKING AND HOOD | | EQUIPMENT INDICATED. THERE ARE NO INDICATIONS IF THE | | NOTED EQUIPMENT IS NEW OR EXISTING. | | | | PER NFPA 101, CHAPTER 12 OR 13, NEW OR EXISTING | | ASSEMBLY OCCUPANCIES | | | | 12.3.2.2 COOKING EQUIPMENT. COOKING EQUIPMENT SHALL BE | | PROTECTED IN ACCORDANCE WITH 9.2.3, UNLESS THE COOKING | | EQUIPMENT | | IS ONE OF THE FOLLOWING TYPES: | | (1) OUTDOOR EQUIPMENT | | (2) PORTABLE EQUIPMENT NOT FLUE-CONNECTED | | (3) EQUIPMENT USED ONLY FOR FOOD WARMING | | | | ALL COOKING AND HOOD EQUIPMENT NEW OR EXISTING SHALL BE | | INSPECTED AND TESTED FOR COMPLIANCE WITH THE APPLICABLE | | CODE. | | | | PLEASE REVIEW AND PROVIDE DETAILS | | | | | | | | | | 5) FIRE SPRINKLER DOCUMENTS ARE INDICATED WITH THE | | BACK-UP INFORMATION PACKET . THESE DOCUMENTS ARE | | ACCEPTED AS INFORMATIONAL PURPOSES ONLY. | | | | FIRE SPRINKLER SHOP DRAWINGS SHALL BE SUBMITTED | | SEPARATELY FOR APPROVAL. | | | | | | | | 6) DOOR INFORMATION DOCUMENTS ARE INDICATED WITH THE | | BACK-UP INFORMATION PACKET. THOSE DOCUMENTS ARE | | INDICATED WITH HELLBENT CUSTOM GARAGE IN THE TITLE | | BLOCKS | | | | PLEASE REVIEW AND CORRECT. | | | | | | | | 7) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | | | 8) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2018-09-19 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2018-09-19 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2018-09-18 |
Time |
15:10 |
Sent To |
I |
|
Notes |
2018-09-18 16:54:29 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) SHEET A 03 - THE OCCUPANCY LOAD CALCULATIONS DO NOT | | INDICATE NUMBERS FOR THE KITCHEN OR BAR SERVICE AREA. | | | | PLEASE REVIEW AND PROVIDE DETAILS | | | | | | | | | | 2) THERE ARE NO DIMENSIONS INDICATED TO VERIFY THE | | OCCUPANCY LOAD OF THE SEATING AREA. THE BATHROOMS | | SHOULD NO BE INCLUDED WITH THE SEATING AREA. | | | | ADDITIONALLY, THERE ARE NO DIMENSIONS INDCATED BETWEEN | | THE SEATS OR EACH AISLE TO ENSURE REQUIRED WIDTHS OR | | PASSAGE. | | | | PER NFPA 101, CHAPTER 12 OR 13, NEW OR EXISTING | | ASSEMBLY OCCUPANCIES | | | | 12.2.5.8 AISLES SERVING SEATING AT TABLES. | | | | 12.2.5.8.2* THE WIDTH OF AISLES SERVING SEATING AT | | TABLES SHALL BE | | NOT LESS THAN 44 IN. (1120 MM) WHERE SERVING AN | | OCCUPANT LOAD | | EXCEEDING 50, AND 36 IN. (915 MM) WHERE SERVING AN | | OCCUPANT | | LOAD OF 50 OR FEWER. | | 12.2.5.8.3* WHERE NONFIXED SEATING IS LOCATED BETWEEN A | | TABLE AND | | AN AISLE, THE MEASUREMENT OF REQUIRED CLEAR WIDTH OF | | THE AISLE SHALL | | BE MADE TO A LINE 19 IN. (485 MM), MEASURED | | PERPENDICULARLY TO | | THE EDGE OF THE TABLE, AWAY FROM THE EDGE OF SAID | | TABLE. | | 12.2.5.9 APPROVAL OF LAYOUTS. | | 12.2.5.9.1 WHERE REQUIRED BY THE AUTHORITY HAVING | | JURISDICTION, | | PLANS DRAWN TO SCALE SHOWING THE ARRANGEMENT OF | | FURNISHINGS OR | | EQUIPMENT SHALL BE SUBMITTED TO THE AUTHORITY BY THE | | BUILDING | | OWNER, MANAGER, OR AUTHORIZED AGENT TO SUBSTANTIATE | | CONFORMANCE | | WITH THE PROVISIONS OF 12.2.5. | | 12.2.5.9.2 THE LAYOUT PLANS SHALL CONSTITUTE THE ONLY | | ACCEPTABLE | | ARRANGEMENT, UNLESS ONE OF THE FOLLOWING CRITERIA IS | | MET: | | (1) THE PLANS ARE REVISED. | | (2) ADDITIONAL PLANS ARE SUBMITTED AND APPROVED. | | (3) TEMPORARY DEVIATIONS FROM THE SPECIFICATIONS OF THE | | APPROVED PLANS ARE USED, PROVIDED THAT THE OCCUPANT | | LOAD IS | | NOT INCREASED AND THE INTENT OF 12.2.5.9 IS MAINTAINED. | | | | PLEASE REVIEW AND PROVIDE. | | | | | | | | 3) SHEET A 04 - 8 SEATS ARE INDCATED ON THE FLOOR PLAN | | BY THE LEFT SIDE DOUBLE DOORS. 4 OF THE SEAT ENCROACH | | INTO THE PATH OF EGRESS. | | | | THOSE DOORS ARE NOT REQUIRED TO MEET YOUR EGRESS | | DEMAND; HOWEVER, EITHER THOSE DOOR CAN NOT BE INDICATED | | AS AN EXIT OR THE CHAIRS AND TABLES WILL NEED TO BE | | REMOVED. | | | | PER NFPA 101, CHAPTER 7, MEANS OF EGRESS. | | | | 7.1.10 MEANS OF EGRESS RELIABILITY. | | 7.1.10.1* MAINTENANCE. MEANS OF EGRESS SHALL BE | | CONTINUOUSLY | | MAINTAINED FREE OF ALL OBSTRUCTIONS OR IMPEDIMENTS TO | | FULL INSTANT | | USE IN THE CASE OF FIRE OR OTHER EMERGENCY. | | | | | | | | 4) SHEET A 06 - THERE IS KITCHEN COOKING AND HOOD | | EQUIPMENT INDICATED. THERE ARE NO INDICATIONS IF THE | | NOTED EQUIPMENT IS NEW OR EXISTING. | | | | PER NFPA 101, CHAPTER 12 OR 13, NEW OR EXISTING | | ASSEMBLY OCCUPANCIES | | | | 12.3.2.2 COOKING EQUIPMENT. COOKING EQUIPMENT SHALL BE | | PROTECTED IN ACCORDANCE WITH 9.2.3, UNLESS THE COOKING | | EQUIPMENT | | IS ONE OF THE FOLLOWING TYPES: | | (1) OUTDOOR EQUIPMENT | | (2) PORTABLE EQUIPMENT NOT FLUE-CONNECTED | | (3) EQUIPMENT USED ONLY FOR FOOD WARMING | | | | ALL COOKING AND HOOD EQUIPMENT NEW OR EXISTING SHALL BE | | INSPECTED AND TESTED FOR COMPLIANCE WITH THE APPLICABLE | | CODE. | | | | PLEASE REVIEW AND PROVIDE DETAILS | | | | | | | | | | 5) FIRE SPRINKLER DOCUMENTS ARE INDICATED WITH THE | | BACK-UP INFORMATION PACKET . THESE DOCUMENTS ARE | | ACCEPTED AS INFORMATIONAL PURPOSES ONLY. | | | | FIRE SPRINKLER SHOP DRAWINGS SHALL BE SUBMITTED | | SEPARATELY FOR APPROVAL. | | | | | | | | 6) DOOR INFORMATION DOCUMENTS ARE INDICATED WITH THE | | BACK-UP INFORMATION PACKET. THOSE DOCUMENTS ARE | | INDICATED WITH HELLBENT CUSTOM GARAGE IN THE TITLE | | BLOCKS | | | | PLEASE REVIEW AND CORRECT. | | | | | | | | 7) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | | | 8) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
4 |
Status |
P |
Date |
2019-01-16 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2019-01-16 |
Time |
06:53 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2019-01-16 |
Time |
06:46 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
F |
Date |
2018-12-20 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2018-12-20 |
Time |
06:05 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2018-12-18 |
Time |
13:41 |
Sent To |
|
|
Notes |
2018-12-20 05:09:44 | 1) SUBMIT MANUFACTURER'S SPECIFICATIONS AND | | INSTALLATION MANUALS FOR ALL GAS EQQUIPMENT.A NOTE ON | | SHT.P-3 FOR THE TANKLESS WATER HEATER IS INSUFFICIENT. | | EQUIPMENT SHALL BE LISTED AND LABELED PER 2017 FBC-FUEL | | GAS SEC.301.3, WPB AMEND. TO FBC SEC.. 107.2.1. 2ND | | REQUEST. | | 2) SHOW THE DISTANCE FROM THE TANKLESS WATER HEATER TO | | THE REAR DOOR AND ALL OTHER OPENINGS INTO THE BUILDING. | | THE TANKLESS WATER HEATER SHALL BE LOCATED IN | | ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION MANUAL. | | 2017 FBC-FUEL GAS SEC.305.1. | | 3) THE COMBUSTION AIR CALCULATIONS THAT HAVE BEEN | | SUBMITTED DO NOT CORRELATE WITH THE EQUATION IN THE | | CODE ALTHOUGH THE FINAL TOTAL CFM IS CORRECT. REVISE | | THE EQUATION NUMBERS TO COMPLY WITH THE CODE. PLEASE | | REFER TO 2017 FBC-FUEL GAS SEC.304.9. | | 4) EACH OF THE APPLIANCES SERVED SHALL BE INTERLOCKED | | WITH THE MECHANICAL AIR SUPPLY SYSTEM TO PREVENT MAIN | | BURNER OPERATION WHEN THE MECHANICAL AIR SUPPLY SYSTEM | | IS NOT IN OPERATION. 2017 FBC- FUEL GAS SEC. 304.9.2. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
F |
Date |
2018-11-28 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2018-11-28 |
Time |
09:28 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2018-11-28 |
Time |
06:16 |
Sent To |
I |
|
Notes |
2018-11-28 07:03:52 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | FAC= FLORIDA ADMINISTRATIVE CODE | | FS = FLORIDA STATUTES | | | | GAS COMMENTS: DENIED | | | | 1.PLAN SHEET P-2; GAS ISOMETRIC. GAS PIPING DOES NOT GO | | THROUGH THE ANSUL SYSTEM. ACCESSIBLE EMERGENCY VALVE TO | | BE INSTALLED IN LINE TO KITCHEN COOKING LINE. | | A. EMERGENCY GAS VALVE PIPING IS SHOWN GOING TO A DEAD | | END. ACCESSIBLE EMERGENCY GAS VALVE TO BE INSTALLED IN | | LINE TO KITCHEN COOKING APPLIANCES AND CONTROLLED BY | | THE ANSUL SYSTEM TO COMPLY. | | 2. SUBMIT MANUFACTURER'S SPECIFICATION SHEETS / | | INSTALLATION MANUAL FOR ALL GAS EQUIPMENT INCLUDING THE | | TANKLESS WATER HEATER TO VERIFY COMPLIANCE WITH | | STANDARDS NFPA 54, NFPA 58, AND FBC FG 402.2, AND 301.3 | | GAS APPLIANCES SHALL BE LISTED AND LABELED. THE | | INSTALLATION MANUALS FOR ALL GAS APPLIANCES / EQUIPMENT | | SHALL BE ONSITE AT THE TIME OF INSPECTION. FBC FG 305.1 | | 3. SHT. P-2 - THERE IS A NOTE AT THE GAS RISER THAT | | REFERS TO THE 2014 FUEL GAS CODE. THE GAS CODE IN | | EFFECT IS THE 2017 CODE. REVISE THE NOTE. | | 4) SUBMIT COMBUSTION AIR CALCULATIONS FOR THE GAS | | EQUIPMENT PER 2017 FBC-FUEL GAS SEC. 304.1.WHERE | | COMBUSTION AIR IS PROVIDED BY THE BUILDING'S MECHANICAL | | VENTILATION SYSTEM,THE SYSTEM SHALL PROVIDE THE | | SPECIFIED COMBUSTION AIR RATE IN ADDITION TO THE | | REQUIRED VENTILATION AIR. 2017 FBC-FUEL GAS | | SEC.304.9.3. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED "VOID". | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2018-10-02 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2018-10-02 |
Time |
16:15 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2018-10-04 |
Time |
08:28 |
Sent To |
|
|
Notes |
2018-10-04 08:28:21 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | FAC= FLORIDA ADMINISTRATIVE CODE | | FS = FLORIDA STATUTES | | | | 1ST REVIEW: | | GAS COMMENTS: DENIED | | | | 1. RE: PLAN SHEET P-2; GAS ISOMETRIC. EMERGENCY HOOD | | SHUT DOWN SHUT OFF VALVE SHALL BE BELOW THE CEILING. | | THE MANUAL SHUTOFF VALVE SHALL BE UPSTREAM OF KITCHEN | | EQUIPMENT. UNION TO BE DOWN STREAM OF MANUAL VALVE. | | SECS. 10.4, 10.5 OF NFPA 96-08. | | A. EMERGENCY GAS VALVE PIPING IS SHOWN GOING TO A DEAD | | END. ACCESSIBLE EMERGENCY GAS VALVE TO BE INSTALLED IN | | LINE TO KITCHEN COOKING APPLIANCES AND CONTROLLED BY | | THE ANSUL SYSTEM TO COMPLY. | | 2. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS / | | INSTALLATION MANUAL FOR ALL GAS EQUIPMENT INCLUDING | | REGULATORS TO VERIFY COMPLIANCE WITH STANDARDS NFPA 54, | | NFPA 58, AND FBC FG 402.2, AND 301.3 GAS APPLIANCES | | SHALL BE LISTED AND LABELED. THE INSTALLATION MANUALS | | FOR ALL GAS APPLIANCES / EQUIPMENT SHALL BE ONSITE AT | | THE TIME OF INSPECTION. FBC FG 305.1 | | 3. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE, | | TERMINATION POINT, HEIGHT ABOVE THE ROOF AND ANCHORING | | DETAILS FOR GAS REGULATOR VENTS IF APPLICABLE (SEE NOTE | | 2 AND FBC FG 410.3) PER FBC-FG SECS. 502 THRU 505 WPB | | FBC 107.2.1 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED "VOID". | | | | | | JERALD SMITH | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | EMAIL [email protected] | | PHONE 561-805-6715 | | | 2018-10-02 16:14:48 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | FAC= FLORIDA ADMINISTRATIVE CODE | | FS = FLORIDA STATUTES | | | | 1ST REVIEW: | | PLUMBING COMMENTS: DENIED | | | | 1. RE: PLAN SHEET P-2; GAS ISOMETRIC. GAS PIPING DOES | | NOT GO THROUGH THE ANSUL SYSTEM. ACCESSIBLE EMERGENCY | | VALVE TO BE INSTALLED IN LINE TO KITCHEN COOKING LINE. | | 2. PROVIDE MANUFACTURER"S SPECS FOR ALL GAS FIRED | | EQUIPMENT INCLUDING THE TANKLESS WATER HEATER. WPB FBC | | 107.2.1 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED "VOID". | | | | | | JERALD SMITH | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | EMAIL [email protected] | | PHONE 561-805-6715 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2019-01-16 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2019-01-16 |
Time |
06:49 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2019-01-11 |
Time |
14:53 |
Sent To |
|
|
Notes |
2019-01-14 14:53:41 | RESUB ROUTED TO TKLARGE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2018-12-20 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2018-12-20 |
Time |
06:27 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2018-12-06 |
Time |
14:57 |
Sent To |
|
|
Notes |
2018-12-10 11:37:40 | B09 | 2018-12-07 14:57:09 | LIBRARY |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2018-11-16 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2018-11-16 |
Time |
15:05 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2018-10-22 |
Time |
15:46 |
Sent To |
|
|
Notes |
2018-11-14 12:58:13 | TO CC DESK | 2018-10-23 15:46:46 | B23 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-10-11 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-10-11 |
Time |
06:55 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-09-13 |
Time |
16:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2018-11-15 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-11-15 |
Time |
15:15 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-11-15 |
Time |
07:45 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2018-09-25 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-09-25 |
Time |
10:20 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-09-25 |
Time |
09:18 |
Sent To |
|
|
Notes |
2018-09-25 10:49:23 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT #18090558 | | 9/25/18 | | | | CODES IN EFFECT: | | | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET M-1: RECIRCULATION OF AIR FROM THE KITCHEN | | INTO THE BAR AREAS VIA AHU'S 1 & 3 IS PROHIBITED PER | | TABLE 403.3.1.1 FOOTNOTE B FBC M. | | | | 2) M-1: DUCT SMOKE DETECTORS ARE REQUIRED IN THE SUPPLY | | AIR SYSTEMS OF THE 5-TON AC-1 & 3 SYSTEMS PER SECTION | | 606.2.1. PLEASE NOTE THAT AN EXEMPTION CAN BE APPLIED | | IF THE MANUFACTURER'S SPECIFICATIONS INDICATE THE | | SYSTEMS ARE NOT CAPABLE OF PRODUCING OVER 2000 CFMS OF | | SUPPLY AIR. | | | | 3) M-1: THE LOCATION OF THE O/A INTAKE APPEARS TO BE | | WITHIN THE MINIMUM 10' REQUIRED CLEARANCE TO THE ALLEY | | AND THE PROPERTY LINE- SECTION 401.4 FBC M. | | | | 4) M-1: PROVIDE WIND LOAD ENGINEERING FOR TIE DOWN OF | | THE NEW CONDENSER ON THE EXITING STAND- SECTION 301.15 | | FBC M. | | | | 5) P-1: PROVIDE COMBUSTION AIR CALCULATIONS FOR THE NEW | | GAS-FIRED COOKING APPLIANCES- SECTION 304 FBC FG. | | | | 6) P-1: SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE | | GAS-FIRE COOKING APPLIANCES- SECTION 623.1 FBC FG. | | | | 7) ADVISORY: PLEASE REFER TO SECTION 508.1.1 FBC M. | | ALTHOUGH THE KITCHEN HOOD IS UNDER A SEPARATE, THE | | REQUIREMENT CONCERNING THE TEMPERATURE OF THE MAKEUP | | AIR MAY EFFECT THE MAIN HVAC DESIGN. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2019-01-16 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2019-01-16 |
Time |
06:45 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2019-01-16 |
Time |
05:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2018-12-20 |
Time |
|
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2018-12-20 |
Time |
06:05 |
Sent To |
I |
|
Notes |
2018-12-20 06:26:23 | 1) SHT. P-1 - THE SAMPLING PORT SHOWN FOR THE GREASE | | TRAP IS UNACCEPTABLE .THE SAMPLING PORT SHALL BE | | MINIMUM 4 INCH TWO WAY CLEANOUT PER THE CITY OF WEST | | PALM BEACH UTILITIES DEPT.YOU HAVE REVISED THE PLAN | | VIEW BUT HAVE NOT REMOVED THIS DETAIL FROM THE | | PLANS.2ND REQUEST. | | 2) THE PLUMBING SANITARY RISER AND PLAN VIEW FOR THE | | BAR AREA STILL SHOWS THE ICE BINS DISCHARGING TO THE | | INTERCEPTOR. THE CLEAR WATER WASTE SHALL NOT DISCHARGE | | TO THE INTERCEPTOR. 2017 FBC-PLUMBING. SEC. 1003.2. 2ND | | REQUEST. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2018-11-16 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2018-11-16 |
Time |
15:04 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2018-11-16 |
Time |
14:38 |
Sent To |
I |
|
Notes |
2018-11-16 15:00:34 | 1) THE SAMPLING PORT SHOWN FOR THE GREASE TRAP IS | | UNACCEPTABLE. THE SAMPLING PORT SHALL BE A MINIMUM 4 | | INCH TWO WAY CLEANOUT PER THE CITY OF WEST PALM BEACH | | UTILITIES DEPT. | | 2) THE CLEAR WATER WASTE FROM THE ICE BIN, ICE MAKER | | AND ANY OTHER CLEAR WATER WASTE SHALL NOT DISCHARGE | | INTO THE GREASE INTERCEPTOR. 2017 FBC-PLUMBING | | SEC.1003.2. | | 3) THE HOT WATER LINES SHALL BE INSULATED IN ACCORDANCE | | WITH THE 2017 FBC-ENERGY SEC.C404.4 & IN THE THICKNESS | | REQUIRED BY TABLE C403.2.10. | | 4) THE LOCATION OF THE TANKLESS WATTER HEATER SHALL BE | | LOCATED A MINIMUM OF 4 FEET FROM OPERABLE DOORS AND | | WINDOWS PER THE MANUFACTURER'S INSTALLATION | | INSTRUCTIONS. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2018-10-02 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2018-10-02 |
Time |
16:01 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2018-10-02 |
Time |
16:01 |
Sent To |
|
|
Notes |
2018-10-02 16:01:45 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | FAC= FLORIDA ADMINISTRATIVE CODE | | FS = FLORIDA STATUTES | | | | 1ST REVIEW: | | PLUMBING COMMENTS: DENIED | | | | 1. RE: PLAN SHEET P-2; WATER ISOMETRIC. PROVIDE | | INFORMATION FOR TYPICAL BACKFLOW PREVENTOR(S) SHOWN ON | | WATER SUPPLY(S). INCLUDE TYPE, MODEL NUMBER AND ASSE | | STANDARD FOR COMPLIANCE. IF THERE IS A RELIEF OPENING | | ON THE DEVICE THEN PROVIDE DETAILS FOR DISCHARGE | | PIPING. WPB FBC 107.2.1 | | 2. RE: PLAN SHEET P-3; TANKLESS WATER HEATER. PROVIDE | | MANUFACTURER, MODEL # AND SPECS FOR THE WATER HEATER. | | WPB FBC 107.2.1 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED "VOID". | | | | | | JERALD SMITH | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | EMAIL [email protected] | | PHONE 561-805-6715 |
|
|