Plan Review Details - Permit 18090217
Plan Review Stops For Permit 18090217 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2019-12-13 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-12-13 |
Time |
10:19 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-12-13 |
Time |
10:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2019-06-18 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-06-18 |
Time |
08:02 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-06-17 |
Time |
16:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2018-10-19 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2018-10-19 |
Time |
07:56 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2018-10-19 |
Time |
07:56 |
Sent To |
|
|
Notes |
2018-10-19 07:57:20 | ****CORRECTIONS**** | | W.P.B. PERMIT: 18090217 | | REVIEWED: OCTOBER 18, 2018 | | | | DYLAN BATTLES | | BUILDING PLANS EXAMINER I | | [email protected] | | 561-805-6718 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC AMENDED = FLORIDA BUILDING CODE,6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC ENERGY = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1. [FBC AMENDED 107.2.5]SUPPLY A SEPARATE PERMIT | | APPLICATION WITH SEPARATE ADDRESS FOR WEST BUILDING. | | | | 2. [FBC AMENDED 107.2.5]THE PROPOSED STRUCTURE ON THE | | EAST SIDE OF PARKING AREA IS ON THE PROPERTY LINE. | | WHILE THE SAME OWNER HOLDS BOTH PARCELS, A UNITY OF | | TITLE WOULD NEED TO COMBINE THE PROPERTY INTO ONE | | PARCEL. | | SUBMIT APPLICATION TO THE ENGINEERING DEPARTMENT: | | HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR | | MS,-PERMITS-APPLICATIONS | | IF THIS HAS ALREADY BEEN DONE, PLEASE PROVIDE A COPY OF | | THE RECORDED DOCUMENT. | | | | 3. [FBC AMENDED 107.2.5]SHEET S-1 HAS SECTION CUTS THAT | | REFER TO SHEET S-2. PLEASE PROVIDE SHEET S-2 TO SHOW | | THE REST OF THE STRUCTURE. I SEE FOUNDATION AND I-BEAM | | POSTS, BUT I CAN?T TELL WHAT THE POSTS ARE FOR. IS | | THERE A ROOF STRUCTURE? FULL REVIEW WILL BE COMPLETED | | UPON RECEIPT OF ALL DRAWINGS. ALSO, CO-ORDINATE WITH A | | SHEETS SO SIZES AND ELEVATIONS MATCH. | | | | 4. [FBC AMENDED 107.2.5]UPDATE SHEET S-1 STRUCTURAL | | DESIGN CRITERIA AND CODE. | | D-3 PROVIDE LOADS FOR THIS PROJECT. | | D-4 THE STRUCTURES ARE NOT ENCLOSED | | | | 5. [FBC 401.4]PROVIDE COPY OF GEOTECHNICAL REFERENCED | | IN GEOTECHNICAL AND FOUNDATIONS F-1 | | | | 6. [FBC 1609.1]PROVIDE DETAILS OF HOW EQUIPMENT IS | | ATTACHED TO THE PAD. | | | | NOTE: | | -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | EACH COMMENT IS BEING ADDRESSED. | | -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW | | OF MATERIALS REQUESTED. | | -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS | | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | NEED "VOID", RENDERING THEM NOT USABLE. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2019-06-19 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-06-19 |
Time |
09:30 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-06-18 |
Time |
15:35 |
Sent To |
|
|
Notes |
2019-06-19 09:37:57 | APPROVED WITH PROVISO ON PLAN: HIGH-LEG MARKING PER NEC | | 110.15. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2018-09-24 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2018-09-24 |
Time |
10:04 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2018-09-24 |
Time |
07:26 |
Sent To |
|
|
Notes |
2018-09-24 10:04:12 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PLAN IS REQUIRED TO BE DESIGNED BY AN ELECTRICAL | | ENGINEER AS IT EXCEEDS THE VALUES PERMITTED IN FLORIDA | | STATUTE 471.003(2)(H). | | 2. PLAN PROVIDED SHOWS INSTALLATIONS FOR DIFFERENT | | BUIDLINGS WHICH HAVE A DIFFERENT ADDRESS. THERE SHOULD | | BE TWO PERMIT APPLICATION, ONE FOR EACH ADDRESS. | | PROVIDE SECOND PERMIT APPLICATION WITH PERTINENT | | INFORMATION FOR EACH PROJECT. REMOVE ANY INFORMATION | | FROM THIS PACKET WHICH DOES NOT PERTAIN TO 435 SOUTHERN | | BLVD. WPB FBC 105.1 | | 3. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS | | IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. FBC 109.3 | | 4. BUILDING PLANS SHALL BE DRAWN TO A MINIMUM 1/8 INCH | | SCALE UPON SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE | | MEDIUM. PROVIDE CORRECTION. WPB FBC 107.2.1.3 | | 5. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | IS ADEQUATE. NEC 215.2, 220, 408.30 | | 6. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | 250.50, 250.94, 408.30 | | 7. PROVIDE PANEL SCHEDULE FOR EACH PANEL INDICATING ANY | | NEW OR ALTERED CIRCUITS, THE WIRE AND BREAKER SIZE FOR | | THESE CIRCUITS, AND AFCI OR GFCI PROTECTION WHERE | | APPLICABLE TO COMPLY WITH CODE. NEC 210.8, 210.12, | | 210.19, 210.20, 215.5, 408.4 | | 8. PROVIDE AIC RATING OF EACH PANEL. NEC 110.3, 110.9 | | 9. PROVIDE AIC CALCULATION FOR EACH NEW PANEL | | INSTALLED. NEC 110.10 | | 10. PLAN SHOWS A NEUTRAL CONDUCTOR GOING TO 80KVA | | TRANSFORMER. PROVIDE CORRECTION. NEC 250.30 | | | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2019-06-19 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2019-06-19 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2019-06-19 |
Time |
14:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2018-09-17 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2018-09-17 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2018-09-14 |
Time |
11:54 |
Sent To |
|
|
Notes |
2018-09-17 10:37:13 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) THE SUBMITTED PLAN SHEETS WHERE NOT PROVIDED WITH | | ANY KIND OF ORDER AND WERE NOT ORGAINIZED OR BOUND | | TOGETHER AS SETS. | | | | PER NFPA 1 | | | | 1.7.11 PLANS AND SPECIFICATIONS. | | | | 1.7.11.1 THE AHJ SHALL HAVE THE AUTHORITY TO REQUIRE | | PLANS AND SPECIFICATIONS TO ENSURE COMPLIANCE WITH | | APPLICABLE CODES AND STANDARDS. | | | | | | PLEASE REVIEW AND PROVIDE COMPLETED SETS IN AN | | ORGANIZED MANNER | | | | | | | | 2) THERE ARE NO INDICATIONS OF A FIRE SPRINKLER SYSTEM | | IN EITHER OF THE BUILDINGS. | | | | PER NFPA 1, CHAPTER 13, FIRE PROTECTION SYSTEMS | | | | 13.3.2.28 WOODWORKING OPERATIONS. AN APPROVED AUTOMATIC | | FIRE SPRINKLER SYSTEM SHALL BE INSTALLED IN BUILDINGS | | CONTAINING | | WOODWORKING OPERATIONS EXCEEDING 2500 FT2 (232 M2) THAT | | USE | | EQUIPMENT, MACHINERY, OR APPLIANCES; THAT GENERATE | | FINELY DIVIDED | | COMBUSTIBLE WASTE; OR THAT USE FINELY DIVIDED | | COMBUSTIBLE | | MATERIALS. | | | | PLEASE REVIEW AND PROVIDE FOR THE REQUIREMENT OF | | JUSTIFY, | | | | | | CHAPTER 40 DUST EXPLOSION AND FIRE PREVENTION | | | | 40.1 GENERAL. EQUIPMENT, PROCESSES, AND OPERATIONS THAT | | INVOLVE | | THE MANUFACTURE, PROCESSING, BLENDING, REPACKAGING, OR | | HANDLING | | OF COMBUSTIBLE PARTICULATE SOLIDS OR COMBUSTIBLE DUSTS | | REGARDLESS | | OF CONCENTRATION OR PARTICLE SIZE SHALL BE INSTALLED | | AND MAINTAINED | | IN ACCORDANCE WITH THIS CHAPTER AND THE FOLLOWING | | STANDARDS AS | | APPLICABLE: | | (1) NFPA 61, STANDARD FOR THE PREVENTION OF FIRES AND | | DUST | | EXPLOSIONS IN AGRICULTURAL AND FOOD PROCESSING | | FACILITIES | | (2) NFPA 69, STANDARD ON EXPLOSION PREVENTION SYSTEMS | | (3) NFPA 85, BOILER AND COMBUSTION SYSTEMS HAZARDS CODE | | (4) NFPA 120, STANDARD FOR FIRE PREVENTION AND CONTROL | | IN | | COAL MINES | | (5) NFPA 484, STANDARD FOR COMBUSTIBLE METALS | | (6) NFPA 654, STANDARD FOR THE PREVENTION OF FIRE AND | | DUST | | EXPLOSIONS FROM THE MANUFACTURING, PROCESSING, AND | | HANDLING OF COMBUSTIBLE PARTICULATE SOLIDS | | (7) NFPA 655, STANDARD FOR PREVENTION OF SULFUR FIRES | | AND | | EXPLOSIONS | | (8) NFPA 664, STANDARD FOR THE PREVENTION OF FIRES AND | | EXPLOSIONS IN WOOD PROCESSING AND WOODWORKING | | FACILITIES | | | | | | | | | | 3) THERE ARE NO INDICATIONS THAT THE PROPOSED PROJECT | | IS IN COMPLIANCE OR REVIEWED THROUGH THE REQUIREMENTS | | OF NFPA 664 | | | | PER NFPA 1, CHAPTER 31, FOREST PRODUCTS | | | | 31.1* GENERAL. THE STORAGE, MANUFACTURING, AND | | PROCESSING OF | | TIMBER, LUMBER, PLYWOOD, VENEERS, AND BY-PRODUCTS SHALL | | BE IN | | ACCORDANCE WITH THIS CHAPTER AND NFPA 664, STANDARD FOR | | THE | | PREVENTION OF FIRES AND EXPLOSIONS IN WOOD PROCESSING | | AND | | WOODWORKING FACILITIES. | | | | 31.3.9 WOOD PROCESSING AND WOODWORKING FACILITIES. DUST | | CONTROL | | SHALL BE IN ACCORDANCE WITH NFPA 664 FOR COMBUSTIBLE | | DUSTPRODUCING | | OPERATIONS THAT OCCUPY AREAS OF MORE THAN 5000 FT2 (464 | | M2), OR TO AREAS WHERE DUST-PRODUCING EQUIPMENT | | REQUIRES AN | | AGGREGATE DUST COLLECTION FLOW RATE OF MORE THAN 1500 | | FT3/MIN (2549 | | M3/HR). | | | | | | PLEASE REVIEW AND PROVIDE A NOTE OF ACKNOWLEDGEMENT OF | | COMPLIANCE OR JUSTIFY THAT IT IS NOT REQUIRED WITH | | SPECIFIC CODE REFERENCES | | | | | | | | | | 4) THERE IS NO INDICATION OF A COMPLIANCE OPTION PER | | NFPA 664. | | | | 4.7 COMPLIANCE OPTIONS. | | 4.7.1 OPTIONS. LIFE SAFETY, PROPERTY PROTECTION, AND | | MISSION | | CONTINUITY MEETING THE GOALS AND OBJECTIVES OF SECTION | | 4.1 AND | | SECTION 4.6 SHALL BE PROVIDED IN ACCORDANCE WITH EITHER | | OF THE | | FOLLOWING: | | (1) PERFORMANCE-BASED PROVISIONS PER 4.7.2 | | (2) PRESCRIPTIVE-BASED PROVISIONS PER 4.7.3 | | | | | | PLEASE REVIEW AND PROVIDE SPECIFIC DETAILS. | | | | | | | | 5) THERE IS AN INDICATION OF A SPRAY BOOTH AS PART OF | | THIS SUBMITTAL | | | | THE SPRAY BOOTH SHALL BE SUBMITTED UNDER SEPARATE SHOP | | DRAWINGS. | | | | PLEASE SUBMIT SEPARATE SHOP DRAWINGS FOR THE PROPOSED | | SPRAY BOOTH. | | | | | | | | | | 6) THERE IS NO INDICATIONS OF FIRE PROTECTION OF THE | | PROPOSED SPRAY BOOTH. | | | | PER NFPA 1 | | | | CHAPTER 43 SPRAYING, DIPPING, AND COATING USING | | FLAMMABLE OR COMBUSTIBLE MATERIALS | | | | 43.1 APPLICATION. | | 43.1.1* OPERATIONS INVOLVING THE SPRAY APPLICATION OF | | FLAMMABLE | | AND COMBUSTIBLE MATERIALS SHALL COMPLY WITH NFPA 33, | | STANDARD | | FOR SPRAY APPLICATION USING FLAMMABLE OR COMBUSTIBLE | | MATERIALS, AND SECTION 43.1. | | | | 43.1.7 PROTECTION. | | 43.1.7.1* GENERAL. SPRAY AREAS, WHICH INCLUDE BY | | DEFINITION ANY | | ASSOCIATED EXHAUST PLENUMS AND EXHAUST DUCTWORK, ANY | | PARTICULATE | | FILTERS, ANY SOLVENT CONCENTRATOR UNITS, ANY | | RECIRCULATION AIR SUPPLY | | UNITS, AND MIXING ROOMS, SHALL BE PROTECTED WITH AN | | APPROVED | | AUTOMATIC FIRE PROTECTION SYSTEM. | | | | PLEASE PROVIDE FOR THE REQUIRED PROTECTION OR JUSTIFY | | WHY NOT WITH SPECIFIC CODE REFERENCES. | | | | | | | | | | 7) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | | | 8) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2019-12-13 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-12-13 |
Time |
10:19 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-12-06 |
Time |
14:51 |
Sent To |
|
|
Notes |
2019-12-09 14:51:43 | RESUB ROUTED TO CCOLE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-06-23 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2019-06-23 |
Time |
08:52 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2019-06-13 |
Time |
15:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-10-19 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2018-10-19 |
Time |
07:58 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2018-09-07 |
Time |
08:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2019-12-12 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2019-12-12 |
Time |
08:40 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2019-12-12 |
Time |
07:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2019-06-17 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2019-06-17 |
Time |
09:40 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2019-06-17 |
Time |
08:15 |
Sent To |
|
|
Notes |
2019-06-17 10:11:04 | 2ND REVIEW FBC-2017 MECHANICAL | | PERMIT #18090217 | | 9/27/18 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED | | | | THE RESULTS FROM THE 1ST REVIEW COMMENTS ARE INDICATED | | BELOW. | | | | 1) OK | | | | 2) OK | | | | 3) STILL EXISTS- GENERAL SCOPE OF WORK NOTES ON NEW M-1 | | SHEET INCLUDES THE PAINT SPRAY BOOTH. (PLEASE NOTE THAT | | A SEPARATE PERMIT IS REQUIRED FOR THE SPRAY BOOTH SO IT | | WILL NOT BE REVIEWED AT THIS TIME. THE CONTRACTOR OF | | RECORD SHALL SUBMIT A SEPARATE APPLICATION AND TWO SETS | | OF PLANS AND SPECIFICATIONS FOR REVIEW.) | | | | 4) STILL EXISTS- NO CONTRACT OR DOCUMENTATION SUBMITTED | | TO VERIFY COSTS. (THE $50,000 JOB VALUE ON THE PERMIT | | APPLICATION APPEARS LOW FOR THE SCOPE OF THE PROPOSED | | PROJECT. PLEASE SUBMIT DETAILED ESTIMATES AND/OR BONA | | FIDE CONTRACTS FOR ALL PHASES OF THE PROJECT INCLUDING | | STRUCTURAL, ELECTRIC, MECHANICALL, PLUMBING, INTERIOR | | AND EXTERIOR FINISH, SITE WORK, DESIGN FEES, AND OVER | | HEAD AND PROFIT. PLEASE NOTE VALUE IS BASED ON LABOR, | | MATERIALS, AND EQUIPMENT.) | | | | 5) STILL EXISTS- NEW SHEETS A-1 & A-2 SHOW THE 15000 | | CFM COLLECTOR LOCATED 8'4" TO THE ROLL UP DOOR. WHETHER | | NEW OR EXISTING, PROVIDE DOCUMENTATION INDICATING THE | | DOOR IS IMPACT RESISTANT AND CAPABLE OF RESISTING THE | | CURRENT WINDSPEEDS AND PRESSURES PER THE ASCE 7-10- SEE | | SECTION 1609 FBC B. (SHEET A2: THE PLAN DOES NOT | | CLEARLY SHOW THAT THE LOCATIONS OF THE NEW COLLECTORS | | ARE IN COMPLIANCE WITH SECTION 511.1 FBC M WHICH | | REQUIRES A MINIMUM 10' CLEARANCE TO COMBUSTIBLE | | CONSTRUCTION AND ALSO UNPROTECTED OPENINGS INTO THE | | BUILDINGS.) | | | | 6) STILL EXISTS- BASED ON COMMENT 35 ABOVE, A METAL | | VENT PIPE MAY BE REQUIRED TO BE LOCATED ABOVE THE | | HIGHEST ROOF LEVEL WITH A DISTANCE OF 30'- SECTION | | 511.1 FBC M. (A-2, M3, & M4: THE COLLECTOR DRAWINGS ARE | | INCONSISTENT ON HOW THE COLLECTION, EXHAUST, AND RETURN | | SYSTEMS ARE FUNCTIONING. THERE ARE NO EXHAUST | | DISCHARGES SHOWN, OR LABELED FOR THE COLLECTORS, | | HOWEVER THERE APPEARS TO BE A RETURN AIR DUCT INTO THE | | BUILDING AS SHOWN ON SHEETS A2 & M3. PLEASE VERIFY | | COMPLIANCE WITH SECTION 511.1.3). | | | | 7) STILL EXISTS- SPACING OF HANGERS AND ATTRACHMENT TO | | THE STRUCTURE NOT PROVIDED (PROVIDE TYPICAL DETAILS FOR | | DUCT HANGING AND SUPPORT INCLUDING SPACING OF THE | | HANGERS,). | | | | 8) STILL EXISTS- NOT PROVIDED SHEETS S1 & M3: THE | | STRUCTURAL ENGINEER OF RECORD MUST PROVIDE COMPLETE | | DETAILS FOR CONSTUCTION OF THE STEEL FRAIMING AND | | SUPPORT BASES FOR THE COLLECTORS INCLUDING WIND LOAD | | ENGINEERING FOR ATTACHING THE COLLECTORS TO THE | | SUPPORTS AND THE SUPPORTS TO THE FOUNDATIONS- SECTION | | 301.15 FBC M.). | | | | 9) STILL EXISTS- NOT PROVIDED (A FLORIDA LICENSED | | MECHANICAL CONTRACTOR SHALL SUBMIT A SUB-PERMIT | | APPLICATION FOR INSTALLATION OF THE DUCT COLLECTORS AND | | DUCT SYSTEMS- SECTION 489.113 (I) FS.). | | | | 10) NEW COMMENT: SHOW THE LOCATION OF THE REQUIRED | | EXPLOSION RELIEF VENT- SECTION 511.1.5 FBC M. | | | | 11) NEW COMMENT, SHEET M-3: MUCH OF THE PRINT IN THE | | MAXI-FILTER DETAILS IS TOO FAINT TO READ AND SCAN INTO | | THE CITY'S COMPUTER FILES- SECTION 107.2.1 WPB. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2018-09-27 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-09-27 |
Time |
17:54 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-09-27 |
Time |
17:54 |
Sent To |
|
|
Notes |
2018-09-27 18:26:54 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT #18090217 | | 9/27/18 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) DESIGN CRITERIA: PROVIDE A LIST OF CURRENT CODES AND | | STANDARDS USED IN THE DESIGN OF THE PROJECT- SECTION | | 107.2.1 WPB. | | | | 2) PROVIDE ON THE PLAN THE LEVEL OF ALTERATION AS | | OUTLINED IN CHAPTER 5 FBC EX. | | | | 3) PLEASE NOTE THAT A SEPARATE PERMIT IS REQUIRED FOR | | THE SPRAY BOOTH SO IT WILL NOT BE REVIEWED AT THIS | | TIME. THE CONTRACTOR OF RECORD SHALL SUBMIT A SEPARATE | | APPLICATION AND TWO SETS OF PLANS AND SPECIFICATIONS | | FOR REVIEW. | | | | 4) THE $50,000 JOB VALUE ON THE PERMIT APPLICATION | | APPEARS LOW FOR THE SCOPE OF THE PROPOSED PROJECT. | | PLEASE SUBMIT DETAILED ESTIMATES AND/OR BONA FIDE | | CONTRACTS FOR ALL PHASES OF THE PROJECT INCLUDING | | STRUCTURAL, ELECTRIC, MECHANICALL, PLUMBING, INTERIOR | | AND EXTERIOR FINISH, SITE WORK, DESIGN FEES, AND OVER | | HEAD AND PROFIT. PLEASE NOTE VALUE IS BASED ON LABOR, | | MATERIALS, AND EQUIPMENT. | | | | 5) SHEET A2: THE PLAN DOES NOT CLEARLY SHOW THAT THE | | LOCATIONS OF THE NEW COLLECTORS ARE IN COMPLIANCE WITH | | SECTION 511.1 FBC M WHICH REQUIRES A MINIMUM 10' | | CLEARANCE TO COMBUSTIBLE CONSTRUCTION AND ALSO | | UNPROTECTED OPENINGS INTO THE BUILDINGS. | | | | 6) A-2, M3, & M4: THE COLLECTOR DRAWINGS ARE | | INCONSISTENT ON HOW THE COLLECTION, EXHAUST, AND RETURN | | SYSTEMS ARE FUNCTIONING. THERE ARE NO EXHAUST | | DISCHARGES SHOWN, OR LABELED FOR THE COLLECTORS, | | HOWEVER THERE APPEARS TO BE A RETURN AIR DUCT INTO THE | | BUILDING AS SHOWN ON SHEETS A2 & M3. PLEASE VERIFY | | COMPLIANCE WITH SECTION 511.1.3: | | | | 511.1.3 CONVEYING SYSTEMS EXHAUST DISCHARGE. | | AN EXHAUST SYSTEM SHALL DISCHARGE TO THE OUTSIDE OF THE | | BUILDING EITHER DIRECTLY BY FLUE OR INDIRECTLY THROUGH | | THE BIN OR VAULT INTO WHICH THE SYSTEM DISCHARGES | | EXCEPT WHERE THE CONTAMINANTS HAVE BEEN REMOVED. | | EXHAUST SYSTEM DISCHARGE SHALL BE PERMITTED TO BE | | RECIRCULATED PROVIDED THAT THE SOLID PARTICULATE HAS | | BEEN REMOVED AT A MINIMUM EFFICIENCY OF 99.9 PERCENT AT | | 10 MICRONS (10.01 MM), VAPOR CONCENTRATIONS ARE LESS | | THAN 25 PERCENT OF THE LFL, AND APPROVED EQUIPMENT IS | | USED TO MONITOR THE VAPOR CONCENTRATION. | | | | 7) PROVIDE TYPICAL DETAILS FOR DUCT HANGING AND SUPPORT | | INCLUDING SPACING OF THE HANGERS, | | | | 8) SHEETS S1 & M3: THE STRUCTURAL ENGINEER OF RECORD | | MUST PROVIDE COMPLETE DETAILS FOR CONSTUCTION OF THE | | STEEL FRAIMING AND SUPPORT BASES FOR THE COLLECTORS | | INCLUDING WIND LOAD ENGINEERING FOR ATTACHING THE | | COLLECTORS TO THE SUPPORTS AND THE SUPPORTS TO THE | | FOUNDATIONS- SECTION 301.15 FBC M. | | | | 9) A FLORIDA LICENSED MECHANICAL CONTRACTOR SHALL | | SUBMIT A SUB-PERMIT APPLICATION FOR INSTALLATION OF THE | | DUCT COLLECTORS AND DUCT SYSTEMS- SECTION 489.113 (I) | | FS. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | 2018-09-27 17:55:35 | | | | | | | | | | | | | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2019-06-21 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2019-06-21 |
Time |
|
Rev Time |
0.00 |
Received By |
llouie |
Date |
2019-06-21 |
Time |
|
Sent To |
|
|
Notes |
2019-06-21 16:31:19 | ZONING PROVISOS: | | | | 1.) OPAQUE SCREEN REQUIRED FOR THE WEST DUST COLLECTION | | SYSTEM FACING THE STREET SIDE PRIOR TO FINAL | | INSPECTION. SEPARATE PERMIT WILL BE REQUIRED FOR THE | | SCREEN. | | | | 2.) PARKING LOT STRIPING SHALL COMPLY WITH THE STRIPING | | REQUIREMENTS OF ZLDR S.94-485. | | | | (REFERENCE: ZBA 3329) | | | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2018-09-18 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2018-09-18 |
Time |
|
Rev Time |
|
Received By |
llouie |
Date |
2018-09-18 |
Time |
|
Sent To |
|
|
Notes |
2018-09-18 16:06:11 | ** FAILED ** | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | APPLICABLE: | | | | 1.) THE USE ON THE PROPERTY WAS GRANTED A CLASS B | | SPECIAL USE PERMIT (SUBJECT TO CONDITIONS) ON JANUARY | | 7, 2016. AS PART OF THE USE APPROVAL, SEVERAL | | CONDITIONS HAD TO BE MET PRIOR TO THE OPERATION OF THE | | PROPERTY AS A WOOD KITCHEN CABINET MANUFACTURING | | BUSINESS. TO DATE, NOT ALL CONDITIONS HAVE BEEN MET. IF | | THE PROPERTY OWNER FAILS TO SATISFY ALL CONDITIONS | | PRIOR TO THE EXPIRATION OF THE CLASS B PERMIT, THE | | CLASS B PERMIT WILL BE REVOKED AND THE USE SHALL CEASE. | | THE OWNER OF THE BUSINESS SHOULD BE REMINDED TO ADDRESS | | ALL CONDITIONS OF APPROVAL. | | | | 2.) EXISTING PARKING WILL BE ELIMINATED WITH THE | | ADDITION OF THE DUST COLLECTION SYSTEM LOCATED NEXT TO | | THE EXISTING ONE-STORY INDUSTRIAL BUILDING. PLEASE | | DEMONSTRATE THAT SUFFICIENT PARKING WILL REMAIN FOR THE | | USE WITH THE ELIMINATION OF PARKING STALLS BY PROVIDING | | PARKING CALCULATIONS IN THE PLAN (EXISTING VS. | | PROPOSED). | | | | | | PROVISO: THE REQUIRED LANDSCAPE IMPROVEMENTS AS PART OF | | THE CLASS B APPROVAL SHALL BE INSTALLED PRIOR TO FINAL | | INSPECTION OF THE DUST COLLECTION SYSTEMS. A SEPARATE | | PERMIT FOR LANDSCAPING WILL BE REQUIRED. | | | | NOTES: | | | | REFERENCE: ZBA FINAL ORDER 3329 | | | | * REVISION MAY RESULT IN ADDITIONAL COMMENTS. | | | | * ZONE: I | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | QUESTIONS. | | |
|
|
|