Plan Review Details - Permit 18090121
Plan Review Stops For Permit 18090121 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
N |
Date |
2020-03-16 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-03-16 |
Time |
14:49 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-03-16 |
Time |
14:31 |
Sent To |
|
|
Notes |
2020-03-16 14:50:36 | DISREGARD THIS BLDG. REVIEW STOP. SEE ROOFING REVIEW | | THIS DATE. CT |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2019-05-16 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-05-16 |
Time |
15:05 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-05-16 |
Time |
15:05 |
Sent To |
|
|
Notes |
2019-05-16 15:05:24 | PROVISOS: | | 1) PROVIDE PRODUCT APPROVALS FOR ROOFING WITH SUB | | PERMIT. | | 2) PROVIDE PRODUCT APPROVALS FOR WINDOWS, DOORS, | | ROLL-UP DOOR AND STOREFRONT. | | 3) AIPP | | THIS PROJECT MEETS THE CRITERIA TO PROVIDE AIPP. PLEASE | | CONTACT: MS. SYBILLE WELTER ART IN PUBLIC PLACES | | COORDINATOR 822-1515 E-MAIL: [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2019-03-22 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-03-22 |
Time |
07:38 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-03-14 |
Time |
12:42 |
Sent To |
|
|
Notes |
2019-03-22 08:12:48 | PROVISOS: | | 1) FORMBOARD SURVEY TO INSPECTOR PRIOR TO POUR. | | 2) PROVIDE PRODUCT APPROVALS FOR ROOFING WITH SUB | | PERMIT. | | 3) PROVIDE PRODUCT APPROVALS FOR WINDOWS, DOORS, | | ROLL-UP DOOR AND STOREFRONT. | | 4) AIPP | | 5) ENGINEERED FLOODPROOFING SUBMITTAL PER FEMA TB 3-93 | | FLOOD PROOFING AND CERT. | | THE DESIGN B.F.E IS 14.7 FEET NAVD88.-PENDING NFIP | | EVALUATION FOR SUBSTANTIAL IMPROVEMENT | | | | -PENDING NFIP EVALUATION FOR SUBSTANTIAL IMPROVEMENT | | 1612.4.1 FBC[B] MODIFICATION OF ASCE 24. TABLE 6-1 AND | | SECTION 6.2.1 IN ASCE 24 SHALL BE MODIFIED AS FOLLOWS: | | 1. THE TITLE OF TABLE 6.1 SHALL BE MINIMUM ELEVATION OF | | FLOODPROOFING, RELATIVE TO BASE FLOOD ELEVATION (BFE) | | OR DESIGN FLOOD ELEVATION (DFE), IN COASTAL A ZONES AND | | IN OTHER FLOOD HAZARD AREAS THAT ARE NOT HIGH RISK | | FLOOD HAZARD AREAS. | | 2. SECTION 6.2.1 SHALL BE MODIFIED TO PERMIT DRY | | FLOODPROOFING IN COASTAL A ZONES, AS FOLLOWS: ?DRY | | FLOODPROOFING OF NONRESIDENTIAL STRUCTURES AND | | NONRESIDENTIAL AREAS OF MIXED-USE STRUCTURES SHALL NOT | | BE ALLOWED UNLESS SUCH STRUCTURES ARE LOCATED OUTSIDE | | OF HIGH RISK FLOOD HAZARD AREAS AND COASTAL HIGH HAZARD | | AREAS. DRY FLOODPROOFING SHALL BE PERMITTED IN COASTAL | | A ZONES PROVIDED WAVE LOADS AND THE POTENTIAL FOR | | EROSION AND LOCAL SCOUR ARE ACCOUNTED FOR IN THE | | DESIGN. DRY FLOODPROOFING OF RESIDENTIAL STRUCTURES OR | | RESIDENTIAL AREAS OF MIXED-USE STRUCTURES SHALL NOT BE | | PERMITTED. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2019-01-18 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-01-18 |
Time |
15:29 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-01-18 |
Time |
15:29 |
Sent To |
|
|
Notes |
2019-01-18 16:17:23 | ALL COMMENTS CLEAR EXCEPT FOR BASE FLOOD ELEVATION | | (BFE). | | | | THE CITY OF WEST PALM BEACH HAS APPROVED AN ORDINANCE | | WITH PROVISIONS ABOVE THE FEMA MINIMUM STANDARDS. ALL | | NEW COMMERCIAL STRUCTURES SUBMITTED AFTER OCTOBER 5, | | 2017 WILL FOLLOW THE ORDINANCES GUIDELINES FOR FLOOD | | PLAIN MANAGEMENT. | | | | ORDINANCE NO. 4729-17 SEC. 18-34 - TECHNICAL AMENDMENTS | | TO FLORIDA BUILDING CODE, BUILDING. 1612.4.2 ELEVATION | | REQUIREMENTS. THE MINIMUM ELEVATION REQUIREMENTS SHALL | | BE AS SPECIFIED IN ASCE 24 OR THE BASE FLOOD ELEVATION | | PLUS TWO FEET. WHICHEVER IS HIGHER. | | | | ENCLOSURES BELOW THE LOWEST FLOOR. UNIT 5, SECTION E | | COVERED THE REQUIRE-MENTS FOR OPENINGS IN ENCLOSURES. | | IF AN APPLICANT DESIGNS AN ENCLOSURE BELOW THE LOWEST | | FLOOR USING AN ALTERNATIVE TO THE NFIP STANDARD, A | | REGIS-TERED PROFESSIONAL ARCHITECT OR ENGINEER MUST | | CERTIFY THE DESIGN [44 CFR 60.3(C)(5)]. IF A FULL-STORY | | ENCLOSURE IS PLANNED BELOW THE ELEVATED LOWEST FLOOR, | | YOU SHOULD REQUIRE THE APPLICANT TO SIGN A | | NON-CONVERSION AGREEMENT SUCH AS THE ONE IN FIGURE | | 5-13. | | | | PLEASE PROVIDE BASE FLOOD ELEVATION CERTIFICATE FEMA | | FORM 086-0-33 TO SHOW WHAT PROPOSED BASE ELEVATION IS | | GOING TO BE. | | ACCORDING TO THE FIRM MAP FOR WPB THE BFE IS 12.7 FEET. | | ORDINANCE 4729-17 SEC. 18-34 REQUIRES ADDITIONAL | | FREEBOARD OF 2 FEET, SO THE DESIGN BFE SHOULD BE 14.7 | | (SURVEYOR TO VERIFY AND STATE ON CERTIFICATE) | | | | IF THE PROPOSED FLOOR IS LOWER THAN THE DESIGN BFE AND | | THE INTENT IS TO MAINTAIN FLOOR LEVEL OF EXISTING, DRY | | FLOOD PROOFING CAN BE DONE TO THE DESIGN BFE LEVEL. | | DRY FLOODPROOFING WILL REQUIRE A SUBMITTAL AND THE | | ENGINEER WILL ALSO NEED TO PROVIDE DESIGN CERTIFICATION | | FEMA FORM 086-0-34. | | | | PLEASE FEEL FREE TO CALL OR E-MAIL ME ABOUT THIS | | ANYTIME. | | | | DYLAN BATTLES | | BUILDING PLANS EXAMINER I | | [email protected] | | 561-805-6718 | | | | P.S. IT WOULD BE ADVISABLE TO CONTACT YOUR FLOOD | | INSURANCE PROVIDER TO ASK ABOUT | | ONE FOOT DEDUDCTION OF BFE FOR FLOOD PROOFING. WHEN | | FLOOD PROOFING IS DONE INSTEAD | | OF BRINGING THE LOWEST FLOOR ELEVATION UP TO BFE THE | | ADJUSTER WILL TAKE OFF ONE | | FOOT AND THIS MEANS THAT THE FLOODPROOFING WOULD NEED | | TO BE ONE ADDITIONAL FOOT | | TO GET THE SAME RATE AS BRINGING FLOOR UP TO BFE. | | IN THE CASE OF ADDING FREEBOARD BEYOND THE FIRM BFE I | | DON'T KNOW IF YOU WOULD NEED THAT | | ADDITIONAL FOOT ON TOP OF THE ESTABLISHED DESIGN | | ELEVATION. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2018-11-02 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2018-11-02 |
Time |
15:39 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2018-11-01 |
Time |
15:08 |
Sent To |
|
|
Notes |
2018-11-02 15:48:30 | ****CORRECTIONS**** | | W.P.B. PERMIT: 18090121 | | REVIEWED: NOVEMBER 1, 2018 | | | | DYLAN BATTLES | | BUILDING PLANS EXAMINER I | | [email protected] | | 561-805-6718 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC AMENDED = FLORIDA BUILDING CODE,6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC ENERGY = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1. ART IN PUBLIC PLACES | | THE CITY OF WEST PALM BEACH ART IN PUBLIC PLACES | | ORDINANCE REQUIREMENT THAT APPLIES TO ANY REMODEL OR | | NEW CONSTRUCTION PROJECT FOR WHICH THE PERMIT | | APPLICATION WAS SUBMITTED AFTER 6/29/14, AND THE TOTAL | | PROJECT CONSTRUCTION COSTS ARE EQUAL TO OR GREATER THAN | | $750,000 WILL NEED TO COMPLY WITH THIS ORDINANCE. | | PER CITY OF WEST PALM BEACH ORDINANCE NO. 4504-14, AND | | CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE V, | | ART IN PUBLIC PLACES, SECTION 78-123(A) AND SECTION | | 78-126(A), THE ART ASSESSMENT IS 1% OF THE TOTAL | | PROJECT CONSTRUCTION COST. | | PER CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE | | V, ART IN PUBLIC PLACES, SECTION 78-122, RENOVATION AND | | NEW CONSTRUCTION PROJECTS ARE ASSESSED CUMULATIVELY, SO | | THE ART ASSESSMENT WILL BE APPLICABLE TO ALL FUTURE | | PROJECTS. | | SEC. 78-129. - PUBLIC ART ASSESSMENT FOR PRIVATE | | DEVELOPMENT. | | (A) APPLICABILITY. THE PROVISIONS OF THIS ARTICLE AND | | THE PUBLIC ART ASSESSMENT SECTION SHALL APPLY TO ALL | | PRIVATE DEVELOPMENT PROJECTS, INCLUDING NEW | | CONSTRUCTION, OR THE RENOVATION OR IMPROVEMENT OF AN | | EXISTING BUILDING, WHERE TOTAL CONSTRUCTION COSTS ARE | | EQUAL TO OR GREATER THAN $750,000.00. ALL BUILDINGS | | WITHIN NEW PLANNED DEVELOPMENTS SHALL BE ASSESSED | | CUMULATIVELY TOWARDS THIS ART IN PUBLIC PLACES | | REQUIREMENT, EVEN IF THE BUILDINGS ARE PERMITTED | | SEPARATELY OR DEVELOPED IN PHASES. THE PROVISIONS OF | | THIS SECTION APPLY TO NEW DEVELOPMENT OR NEW | | CONSTRUCTION WITHIN EXISTING PLANNED DEVELOPMENTS. | | FOR CONTACT INFORMATION PLEASE CONTACT: | | MS. SYBILLE WELTER ART IN PUBLIC PLACES COORDINATOR | | 822-1515 E-MAIL: [email protected] | | | | 2. [FBC AMENDED 107.3.5.1.1]PROVIDE BASE FLOOD | | ELEVATION(B.F.E.) CERTIFICATE WITH DESIGN FLOOD | | ELEVATIONS TO INCLUDE ANY MECHANICAL EQUIPMENT AS | | APPLICABLE. ALL ELEVATION CERTIFICATES CERTIFIED | | OCTOBER 5, 2017 AND LATER ARE TO UTILIZE NAVD88 AND | | INCLUDE A CONVERSION TO NGVD29. | | | | 3. [ORDINANCE NO. 4658-16][WPB MUNI CODE SEC. 18-33] | | TECHNICAL AMENDMENTS TO FLORIDA BUILDING CODE, | | RESIDENTIAL. BUILDINGS AND STRUCTURES IN FLOOD HAZARD | | AREAS DESIGNATED AS COASTAL A ZONES SHALL HAVE THE | | LOWEST FLOORS ELEVATED TO OR ABOVE THE BASE FLOOD | | ELEVATION PLUS TWO FEET OR THE DESIGN FLOOD ELEVATION, | | WHICHEVER IS HIGHER. | | | | 4. [FBC 401.4]PROVIDE SOIL REPORT TO SHOW BEARING | | CAPACITY AND FOUNDATION RECOMMENDATIONS. UPLOAD INTO | | SUPPORTING FILES. | | | | 5. [FBC 107.2.5]PROVIDE SURVEY OF PROPERTY SHOWING | | EASEMENTS. UPLOAD INTO SUPPORTING FILES. | | | | 6. [FBC 107.3.5.3]UPDATE CODE REFERENCES ON SHEET A0-01 | | ADOPTED DECEMBER 31, 2017 | | BUILDING, ENERGY, MECHANICAL PLUMBING, ACCESSIBILITY | | FLORIDA BUILDING CODE(FBC), 6TH EDITION (2017) | | FLORIDA FIRE PREVENTION, 6TH EDITION | | | | 7. [FBC AMENDED107.3.5]SHEET A0-01 PROJECT INFO DOESN?T | | MATCH LIFE SAFETY SHEET. IF THIS IS EXISTING BUILDING | | DATA PLEASE LABLE AS SUCH, OR MATCH WITH DATA ON LIFE | | SAFETY SHEET. | | WHAT IS THE EXISTING OCCUPANCY(S) OF THE 21,008 SQ. FT. | | SPACE? | | HOW MANY OCCUPANTS? | | | | 8. [FBC 718]HOW ARE THE CONCEALED SPACES HANDLED | | BETWEEN EXISTING AND NEW AT ROLL UP DOOR 006? | | | | 9. [FBC 1907.1]SHEET A3.11 AND A3.12 STATE 4" CONCRETE | | SLAB, BUT STRUCTURAL SHOWS 5" SLAB. PLEASE CO-ORDINATE | | THE ARCHITECTURAL AND STRUCTURAL DRAWINGS TO MATCH. | | SHEET A0-02 WHY EGRESS INTO EXISTING SPACE? IF THAT | | WILL BE AN EGRESS THAN SHOW HOW IT PROVIDE EGRESS TO | | THE PUBLIC RIGHT OF WAY FROM DOOR 003. | | | | 10. [FBC A604.5.1] THE SIDE WALL GRAB BAR SHALL BE 42 | | INCHES (1065 MM) LONG MINIMUM, LOCATED 12 INCHES (305 | | MM) MAXIMUM FROM THE REAR WALL AND EXTENDING 54 INCHES | | (1370 MM) MINIMUM FROM THE REAR WALL. | | [FBC A604.5.2] THE REAR WALL GRAB BAR SHALL BE 36 | | INCHES (915 MM) LONG MINIMUM AND EXTEND FROM THE | | CENTERLINE OF THE WATER CLOSET 12 INCHES (305 MM) | | MINIMUM ON ONE SIDE AND 24 INCHES (610 MM) MINIMUM ON | | THE OTHER SIDE. | | ADJUST NOTES ON A4.11 (DETAIL 1) TO STATE PROPER LENGTH | | OF GRAB BARS IN RESTROOMS. GRAPHICLLY THEY APPEAR | | CORRECT SIZE. | | SHOW LENGTH OF BACK GRAB BARS IN RESTROOMS | | | | 11. [FBC AMENDED 107.3.5]THE ADA PARKING APPEARS TO BE | | IN THE RIGHT OF WAY. | | CONTACT ENGINEERING (561-494-1040) FOR PERMIT THAT | | PERTAINS TO THE R.O.W. | | PROVIDE PARKING DATA TO MEET REQUIREMENTS FOR ADA AND | | NEW SPACES REQUIRED. | | | | 12. [FBC 1510.10]ROOF MOUNTED MECHANICAL UNITS SHALL BE | | MOUNTED ON CURBS RAISED A MINIMUM OF 8 INCHES (203 MM) | | ABOVE THE ROOF SURFACE, OR WHERE ROOFING MATERIALS | | EXTEND BENEATH THE UNIT, ON RAISED EQUIPMENT SUPPORTS | | PROVIDING A MINIMUM CLEARANCE HEIGHT IN ACCORDANCE WITH | | TABLE 1510.10. | | PROVIDE STRUCTURAL DETAIL OF ROOF CURB. | | | | 13. [FBC 1503.4]ROOF DRAINAGE | | PROVIDE ROOF DRAIN CALCULATIONS AND DESIGN TO COMPLY | | WITH SECTIONS 1106 AND 1107, AS APPLICABLE, OF THE | | FLORIDA BUILDING CODE, PLUMBING, CHAPTER 11. | | | | 14. [FBC AMENDED 107.3.4.1]PROVIDE PRODUCT APPROVALS | | FOR ROOFING, OR INDICATE THAT YOU WOULD LIKE THEM | | DEFERED. | | | | 15. [FBC AMENDED 107.3.4.1]PROVIDE PRODUCT APPROVALS | | FOR WINDOWS, DOORS, ROLL-UP DOOR AND STOREFRONT, OR | | INDICATE THAT YOU WOULD LIKE THEM DEFERED. | | | | NOTE: | | -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | EACH COMMENT IS BEING ADDRESSED. | | -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW | | OF MATERIALS REQUESTED. | | -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS | | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | NEED "VOID", RENDERING THEM NOT USABLE. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2018-10-04 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2018-10-04 |
Time |
16:17 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2018-10-04 |
Time |
13:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
Rev No |
1 |
Status |
P |
Date |
2018-10-04 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2018-10-04 |
Time |
13:31 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2018-10-04 |
Time |
13:31 |
Sent To |
|
|
Notes |
2018-10-04 13:31:51 | TELEPHONE AND DATA ONLY |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
4 |
Status |
N |
Date |
2019-05-13 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2019-05-13 |
Time |
|
Rev Time |
0.00 |
Received By |
rrossano |
Date |
2019-05-13 |
Time |
|
Sent To |
I |
|
Notes |
2019-05-13 12:07:52 | PLANS HAVE BEEN APPROVED THROUGH THE FORMAL ENGINEERING | | REVIEW. | | | | FEEL FREE TO CONTACT US IF YOU HAVE ANY QUESTIONS OR | | CONCERNS, THANKS. | | | | RICK ROSSANO | | PROJECT COORDINATOR | | ENGINEERING SERVICES DEPARTMENT | | 401 CLEMATIS STREET, 4TH FLOOR | | WEST PALM BEACH, FL 33401 | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | MAIN PHONE: (561) 822-1200 | | DIRECT: (561) 494-1098 | | FAX: (561) 494-1116 | | MOBILE: (561) 246-9525 | | EMAIL: [email protected] | | WWW.WPB.ORG/ENGINEERING | | | | MANNY GONZALEZ | | SENIOR ENGINEERING PROJECT COORDINATOR | | ENGINEERING SERVICES DEPARTMENT | | 401 CLEMATIS STREET, 4TH FLOOR | | WEST PALM BEACH, FL 33401 | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | MAIN PHONE: (561) 822-1200 | | DIRECT: (561) 494-1085 | | FAX: (561) 494-1116 | | MOBILE: (561) 644-7301 | | EMAIL: [email protected] | | WWW.WPB.ORG/ENGINEERING | | | | CENTRAL OPERATIONS CENTER (DISPATCH): | | 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC | | UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210 | | | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
3 |
Status |
F |
Date |
2019-03-22 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-03-22 |
Time |
07:37 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2019-03-22 |
Time |
07:37 |
Sent To |
|
|
Notes |
2019-03-22 16:14:47 | CONTACT ENGINEERING DEPARTMENT DIRECTLY AND SUBMIT | | APPLICATION IF REQUIRED | | HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS | | /FORMS,-PERMITS-APPLICATIONS | | | | ENGINEERING APPROVAL REQUIRED PRIOR TO PERMIT ISSUANCE | | | | MAIN PHONE: (561) 822-1200 | | | | | 2019-03-22 07:38:12 | DB ENTERED STATUS BY ACCIDENT AND NEW STOP CREATED FOR | | ENGINEERING TO USE. |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
F |
Date |
2019-01-29 |
|
|
Cont ID |
|
Sent By |
RRossano |
Date |
2019-01-29 |
Time |
|
Rev Time |
0.00 |
Received By |
rrossano |
Date |
2019-01-29 |
Time |
|
Sent To |
I |
|
Notes |
2019-01-29 07:11:18 | PROVIDE SEPARATE SUBMITTAL TO ENGINEERING DEPARTMENT | | FOR REVIEW. CITY OF WPB ENGINEERING FORMS AND DESIGN | | REQUIREMENT INFORMATION CAN BE FOUND HERE: HTTP://WPB.O | | RG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FORMS,-PERMITS- | | APPLICATIONS | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2018-11-02 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-11-02 |
Time |
19:41 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-11-02 |
Time |
19:41 |
Sent To |
|
|
Notes |
2018-11-02 19:42:27 | CONTACT ENGINEERING DEPARTMENT DIRECTLY AND SUBMIT | | APPLICATION IF REQUIRED | | HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS | | /FORMS,-PERMITS-APPLICATIONS | | | | ENGINEERING APPROVAL REQUIRED PRIOR TO PERMIT ISSUANCE | | | | MAIN PHONE: (561) 822-1200 | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2019-04-02 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2019-03-05 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2019-03-05 |
Time |
11:52 |
Sent To |
|
|
Notes |
2019-03-05 12:01:09 | 4/2/19 | | | | PER EMAILED COMMENTS FROM MS HAIR, THE EOR LETTER WILL | | BE ATTACHED.PML | | | | | | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) THE RESPONSE TO COMMENT # 4 IS NOT APPROVED. | | ENGINEERED DOCUMENTS ARE REQUIRED TO BE SUBMITTED WITH | | THIS MASTER PERMIT PER THE F.A.C. . | | | | 61G15-30.003 MINIMUM REQUIREMENTS FOR ENGINEERING | | DOCUMENTS. | | (1) ENGINEERING DOCUMENTS ARE PREPARED IN THE COURSE OF | | PERFORMING ENGINEERING SERVICES. WHEN PREPARED FOR | | INCLUSION WITH AN APPLICATION FOR A GENERAL BUILDING | | PERMIT, THE DOCUMENTS SHALL MEET ALL ENGINEER?S | | RESPONSIBILITY RULES, SET FORTH IN CHAPTERS 61G15-31, | | 61G15-32, 61G15-33, AND 61G15-34, F.A.C., AND BE OF | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | WILL CONFORM TO THE PROVISIONS OF THE FLORIDA BUILDING | | CODE, ADOPTED IN SECTION 553.73, F.S., AND APPLICABLE | | LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED | | BY THE AHJ. THE DOCUMENTS SHALL INCLUDE: | | (A) INFORMATION THAT PROVIDES MATERIAL SPECIFICATIONS | | REQUIRED FOR THE SAFE OPERATION OF THE SYSTEM THAT IS A | | RESULT OF ENGINEERING CALCULATIONS, KNOWLEDGE AND | | EXPERIENCE. | | (B) LIST FEDERAL, STATE, MUNICIPAL, AND COUNTY | | STANDARDS, CODES, ORDINANCES, LAWS, AND RULES, WITH | | THEIR EFFECTIVE DATES, THAT THE ENGINEERING DOCUMENTS | | ARE INTENDED TO CONFORM TO. | | (C) INFORMATION, AS DETERMINED BY THE ENGINEER OF | | RECORD, NEEDED FOR THE SAFE AND EFFICIENT OPERATION OF | | THE SYSTEM. | | (D) LIST ENGINEERING DESIGN CRITERIA; REFERENCE PROJECT | | SPECIFIC STUDIES, REPORTS, AND DELEGATED ENGINEERING | | DOCUMENTS. | | (E) IDENTIFY CLEARLY ELEMENTS OF THE DESIGN THAT VARY | | FROM THE GOVERNING STANDARDS AND DEPICT/IDENTIFY THE | | ALTERNATE METHOD USED TO ENSURE COMPLIANCE WITH THE | | STATED PURPOSE OF THESE RESPONSIBILITY RULES. | | (2) ENGINEERS SHALL LEGIBLY INDICATE THEIR NAME AND | | BUSINESS ADDRESS, ON ENGINEERING DOCUMENTS. ENGINEERING | | DOCUMENTS WHICH ARE ISSUED FOR PRELIMINARY OR | | CONCEPTUAL USE, SHALL CLEARLY NOTE THE INTENDED PURPOSE | | OF SUCH DOCUMENTS. | | (3) WHEN ELEMENTS OF THE PROJECT ARE SHOWN ON AN | | ENGINEERING DOCUMENT ONLY FOR INFORMATION OR | | CLARIFICATION AND THE ENGINEER DOES NOT INTEND TO | | ACCEPT RESPONSIBILITY FOR THE ELEMENTS, THE ENGINEER | | SHALL CLEARLY NOTE ON THE DOCUMENTS THE EXTENT OF HIS | | RESPONSIBILITY. | | (4) ENGINEERING DRAWINGS SHALL BE LEGIBLE AND CLEARLY | | DEFINE AND DELINEATE THE WORK IN THE PROJECT. THEY MUST | | ALSO COMPLY WITH CHAPTER 61G15-23, F.A.C., SEALS. | | (5) ENGINEERS SHALL CLEARLY NOTE ON ANY PRELIMINARY | | ENGINEERING DOCUMENTS THAT SUCH DOCUMENTS ARE NOT IN | | FINAL FORM, BUT ARE BEING TRANSMITTED TO THE PUBLIC | | AGENCY TO RECEIVE AGENCY REVIEWS, COMMENTS AND | | INTERPRETATIONS. THE DOCUMENTS MAY SUBSEQUENTLY BE | | REVISED BY THE ENGINEER TO REFLECT RESOLUTION OF ISSUES | | WITH THE PUBLIC AGENCY PRIOR TO FINAL ACTION BY THE | | AGENCY. CHANGES, REVISIONS AND MODIFICATIONS TO A | | PROJECT MAY PROMPT ADDITIONAL DOCUMENT SUBMITTAL FOR | | AGENCY APPROVAL ACTION ON THE SAME PROJECT. | | SPECIFIC AUTHORITY 471.033(2), 471.008 FS. LAW | | IMPLEMENTED 471.033(1)(G), 471.025(3) FS. HISTORY?NEW | | 1-26-93, FORMERLY 21H-30.003, AMENDED 11-13-08. | | | | | | PLEASE SUBMIT THE REQUIRED INFORMATION IN EITHER | | NARRATIVE OR PLAN DRAWINGS. | | | | SHOULD THE EOR DEFER PER # 3 ABOVE, PLEASE CLEARLY | | INDICATE IT. | | | | THIS COMMENT MAY BE PROVISOED WITH AN OFFICIAL | | DOCUMENT/LETTER WITH THE EOR ACCEPTING TO PROVIDE THE | | REQUIRED INFORMATION PRIOR TO ANY FIRE SPRINKLER | | RELATTED WORK UNDER THIS MASTER PERMIT. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2019-01-25 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2019-01-25 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2019-01-25 |
Time |
09:47 |
Sent To |
|
|
Notes |
2019-01-25 10:08:59 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) THE RESPONSE TO COMMENT # 4 IS NOT APPROVED. | | ENGINEERED DOCUMENTS ARE REQUIRED TO BE SUBMITTED WITH | | THIS MASTER PERMIT PER THE F.A.C. . | | | | 61G15-30.003 MINIMUM REQUIREMENTS FOR ENGINEERING | | DOCUMENTS. | | (1) ENGINEERING DOCUMENTS ARE PREPARED IN THE COURSE OF | | PERFORMING ENGINEERING SERVICES. WHEN PREPARED FOR | | INCLUSION WITH AN APPLICATION FOR A GENERAL BUILDING | | PERMIT, THE DOCUMENTS SHALL MEET ALL ENGINEER?S | | RESPONSIBILITY RULES, SET FORTH IN CHAPTERS 61G15-31, | | 61G15-32, 61G15-33, AND 61G15-34, F.A.C., AND BE OF | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | WILL CONFORM TO THE PROVISIONS OF THE FLORIDA BUILDING | | CODE, ADOPTED IN SECTION 553.73, F.S., AND APPLICABLE | | LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED | | BY THE AHJ. THE DOCUMENTS SHALL INCLUDE: | | (A) INFORMATION THAT PROVIDES MATERIAL SPECIFICATIONS | | REQUIRED FOR THE SAFE OPERATION OF THE SYSTEM THAT IS A | | RESULT OF ENGINEERING CALCULATIONS, KNOWLEDGE AND | | EXPERIENCE. | | (B) LIST FEDERAL, STATE, MUNICIPAL, AND COUNTY | | STANDARDS, CODES, ORDINANCES, LAWS, AND RULES, WITH | | THEIR EFFECTIVE DATES, THAT THE ENGINEERING DOCUMENTS | | ARE INTENDED TO CONFORM TO. | | (C) INFORMATION, AS DETERMINED BY THE ENGINEER OF | | RECORD, NEEDED FOR THE SAFE AND EFFICIENT OPERATION OF | | THE SYSTEM. | | (D) LIST ENGINEERING DESIGN CRITERIA; REFERENCE PROJECT | | SPECIFIC STUDIES, REPORTS, AND DELEGATED ENGINEERING | | DOCUMENTS. | | (E) IDENTIFY CLEARLY ELEMENTS OF THE DESIGN THAT VARY | | FROM THE GOVERNING STANDARDS AND DEPICT/IDENTIFY THE | | ALTERNATE METHOD USED TO ENSURE COMPLIANCE WITH THE | | STATED PURPOSE OF THESE RESPONSIBILITY RULES. | | (2) ENGINEERS SHALL LEGIBLY INDICATE THEIR NAME AND | | BUSINESS ADDRESS, ON ENGINEERING DOCUMENTS. ENGINEERING | | DOCUMENTS WHICH ARE ISSUED FOR PRELIMINARY OR | | CONCEPTUAL USE, SHALL CLEARLY NOTE THE INTENDED PURPOSE | | OF SUCH DOCUMENTS. | | (3) WHEN ELEMENTS OF THE PROJECT ARE SHOWN ON AN | | ENGINEERING DOCUMENT ONLY FOR INFORMATION OR | | CLARIFICATION AND THE ENGINEER DOES NOT INTEND TO | | ACCEPT RESPONSIBILITY FOR THE ELEMENTS, THE ENGINEER | | SHALL CLEARLY NOTE ON THE DOCUMENTS THE EXTENT OF HIS | | RESPONSIBILITY. | | (4) ENGINEERING DRAWINGS SHALL BE LEGIBLE AND CLEARLY | | DEFINE AND DELINEATE THE WORK IN THE PROJECT. THEY MUST | | ALSO COMPLY WITH CHAPTER 61G15-23, F.A.C., SEALS. | | (5) ENGINEERS SHALL CLEARLY NOTE ON ANY PRELIMINARY | | ENGINEERING DOCUMENTS THAT SUCH DOCUMENTS ARE NOT IN | | FINAL FORM, BUT ARE BEING TRANSMITTED TO THE PUBLIC | | AGENCY TO RECEIVE AGENCY REVIEWS, COMMENTS AND | | INTERPRETATIONS. THE DOCUMENTS MAY SUBSEQUENTLY BE | | REVISED BY THE ENGINEER TO REFLECT RESOLUTION OF ISSUES | | WITH THE PUBLIC AGENCY PRIOR TO FINAL ACTION BY THE | | AGENCY. CHANGES, REVISIONS AND MODIFICATIONS TO A | | PROJECT MAY PROMPT ADDITIONAL DOCUMENT SUBMITTAL FOR | | AGENCY APPROVAL ACTION ON THE SAME PROJECT. | | SPECIFIC AUTHORITY 471.033(2), 471.008 FS. LAW | | IMPLEMENTED 471.033(1)(G), 471.025(3) FS. HISTORY?NEW | | 1-26-93, FORMERLY 21H-30.003, AMENDED 11-13-08. | | | | | | PLEASE SUBMIT THE REQUIRED INFORMATION IN EITHER | | NARRATIVE OR PLAN DRAWINGS. | | | | SHOULD THE EOR DEFER PER # 3 ABOVE, PLEASE CLEARLY | | INDICATE IT. | | | | THIS COMMENT MAY BE PROVISOED WITH AN OFFICIAL | | DOCUMENT/LETTER WITH THE EOR ACCEPTING TO PROVIDE THE | | REQUIRED INFORMATION PRIOR TO ANY FIRE SPRINKLER | | RELATTED WORK UNDER THIS MASTER PERMIT. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2018-09-24 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2018-09-24 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2018-09-17 |
Time |
12:12 |
Sent To |
|
|
Notes |
2018-09-24 11:54:59 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | | 1) SHEET AO 01 - THE IS AN INCORRECT EDTION OF THE | | FLORIDA FIRE PREVENTION CODE; 5TH EDTION. THE PROJECT | | SHALLBE CONSTRUCTED UNDER THE CURRENT EDTION 6TH. | | | | PLEASE REVIEW, CORRECT AND ENSURE COMPLIANCE | | | | | | | | | | 2) SHEET AO 02 - THE IS A REFERENCE TO COMPLY WITH THE | | 2016 EDTION OF NFPA 13. UNDER THE 6TH EDITION OF THE | | FFPC, THE NFPA 13 EDITION IS 2013 | | | | PLEASE REVIEW, CORRECT AND ENSURE COMPLIANCE | | | | | | | | | | 3) SHEET AO 02 & AO 13 - THERE IS A SEPARATION WALL | | INDICATING A 2 HOUR FIRE WALL; HOWEVER, THE DOUBLE | | DOOR, 011, AT THIS FIRE WALL IS INDICATED AS 20 MINUTE. | | | | THIS RATING DOES NOT MEET THE 2 HOUR FIRE RATING | | REQUIREMENT. | | | | | | | | 4) SHEET AO 02 - NOTE # 7 INDICATES FIRE SPRINKLER | | DRAWING TO BE SUBMITTED UNDER SEPARATE SHOP DRAWINGS. | | | | THE PROPOSED IS NOT AN EXISTING BUILDING, IT IS NEW. | | FIRE SPRINKLER REQUIRMENTS ARE TO BE SUBMITTED AS PART | | OF THIS MASTER IN COMPLIANCE WITH F.A.C. 61G. | | | | 61G15-32.008 DESIGN OF FIRE ALARMS, SIGNALING SYSTEMS | | AND CONTROL SYSTEMS. | | (1) FIRE ALARMS, SIGNALING, AND CONTROL SYSTEMS | | INCLUDE, BUT ARE NOT LIMITED TO, FIRE PROTECTION | | SUPERVISION AND ALARM CIRCUITS, ACTIVATION CONTROLS, | | AND REMOTE SIGNALING. | | (2) THE FIRE PROTECTION SYSTEM DESIGN SPECIFICATIONS | | SHALL BE BASED ON APPLICABLE NFPA STANDARDS, WHEN | | AVAILABLE, OR ALTERNATIVE ENGINEERING SOURCES AND GOOD | | ENGINEERING PRACTICE WHEN REQUIRED, AND SHALL COMPLY | | WITH THE PROVISIONS OF RULE 61G15-33.006, F.A.C. | | SPECIFIC AUTHORITY 471.008, 471.033(2) FS. | | LAW IMPLEMENTED 471.033 FS. | | HISTORY--NEW 5-19-93, FORMERLY 21H-32.008. | | | | FIRE SPRINKLERS | | PER FLORIDA ADMINISTRATIVE CODE SECTION 61G15-32.004, | | FIRE PROTECTION ENGINEERING DOCUMENTS SHALL INCLUDE THE | | POINT OF SERVICE FOR THE WATER SUPPLY, A LIST OF | | APPLICABLE NFPA STANDARDS APPLICABLE TO THE PROJECT, | | CLASSIFICATION OF HAZARD OCCUPANCY FOR EACH ROOM OR | | AREA, SUPPRESSION SYSTEM TYPE, DESIGN DENSITIES, WATER | | SUPPLY DATA (FIRE PUMP DATA, HYDRANT FLOW TEST DATA) | | AND ANY PERFORMANCE BASED INFORMATION SUCH AS | | PRE-ENGINEERED SYSTEMS. | | | | 61G15-32.003 COMMON REQUIREMENTS TO ALL FIRE PROTECTION | | ENGINEERING | | DOCUMENTS. | | (1) THE FIRE PROTECTION SYSTEM ENGINEERING DOCUMENTS | | SHALL PROVIDE THE ENGINEERING REQUIREMENTS TO BE USED | | IN THE PREPARATION OF THE FIRE PROTECTION SYSTEM LAYOUT | | DOCUMENTS AND TO INDICATE THE NATURE AND SCOPE OF THE | | WORK, AND TO DESCRIBE, DETAIL, DIMENSION, LABEL AND | | DEFINE THE FIRE PROTECTION COMPONENTS, SYSTEM(S), | | MATERIALS, ASSEMBLIES, EQUIPMENT AND ITS STRUCTURAL AND | | UTILITY SUPPORT SYSTEM(S), INSOFAR AS THEY INVOLVE THE | | SAFEGUARDING OF LIFE, HEALTH OR PROPERTY. | | (2) THE FIRE PROTECTION SYSTEM ENGINEERING DOCUMENTS | | SHALL SPECIFY THE APPLICABLE REQUIREMENTS FOR THE | | ACCEPTANCE TESTING OF THE FIRE PROTECTION SYSTEM AND | | COMPONENTS, WHICH SHALL BE BASED UPON APPLICABLE CODES | | AND STANDARDS, WHERE AVAILABLE. | | (3) THE OCCUPANCY OF THE AREA OR DESCRIPTION OF A | | SPECIFIC HAZARD BEING PROTECTED BY THE FIRE PROTECTION | | SYSTEM(S) SHALL BE SHOWN ON THE FIRE PROTECTION SYSTEM | | ENGINEERING DOCUMENTS. | | (4) THE APPLICABLE CODE AND STANDARD TO BE USED IN THE | | PREPARATION OF THE FIRE PROTECTION SYSTEM LAYOUT | | DOCUMENTS SHALL BE SHOWN ON THE FIRE PROTECTION SYSTEM | | ENGINEERING DOCUMENTS. WHEN CODES AND STANDARDS ARE NOT | | AVAILABLE OR APPLICABLE, AND SAID LAYOUT DOCUMENTS ARE | | TO BE BASED ON ENGINEERING JUDGMENT, ANY REASONS AND | | ASSUMPTIONS MADE TO DEVELOP THE FIRE PROTECTION CONCEPT | | SHALL BE IDENTIFIED ON THE FIRE PROTECTION SYSTEM | | ENGINEERING DOCUMENTS. | | (5) STRUCTURAL SUPPORT AND STRUCTURAL OPENINGS REQUIRED | | BY THE FIRE PROTECTION SYSTEM SHALL BE SHOWN ON THE | | FIRE PROTECTION SYSTEM ENGINEERING DOCUMENTS AND SHALL | | BE REFERENCED ON STRUCTURAL ENGINEERING DOCUMENTS. | | (6) WHEN LAYOUT DOCUMENTS CONTAIN MATERIAL DEVIATION | | FROM THE ENGINEER OF RECORD'S FIRE PROTECTION SYSTEM | | ENGINEERING DOCUMENT, SUCH LAYOUT DOCUMENTS ARE NOT | | COMPLIANT UNLESS THEY ARE ACCOMPANIED BY REVISED | | ENGINEERING DOCUMENTS MADE AND SEALED BY THE ENGINEER | | OF RECORD FOR THE FIRE PROTECTION SYSTEM. | | (7) REQUIREMENTS FOR ACTIVATION CONTROL SYSTEMS, | | SEQUENCE, OPERATING PARAMETERS, INTERLOCKS, SAFETY | | RELATED DEVICES, INDICATORS AND ALARMS, SHALL BE SHOWN | | ON THE FIRE PROTECTION SYSTEM ENGINEERING DOCUMENTS, | | UNLESS SHOWN ON OTHER RELATED DOCUMENTS. | | (8) ANY INFORMATION DEEMED APPROPRIATE BY THE ENGINEER | | OF RECORD TO ASSIST THE AUTHORITY HAVING JURISDICTION | | IN UNDERSTANDING THE OWNER?S INTENDED USE AND PROPOSED | | PROTECTION OF THE BUILDING OR FACILITY AND TO PROVIDE | | SUFFICIENT DIRECTION TO THE INSTALLATION CONTRACTOR OR | | OTHER INTERESTED PARTIES REGARDING THE LAYOUT OF THE | | SYSTEM(S), SHALL BE INCLUDED IN THE FIRE PROTECTION | | SYSTEM ENGINEERING DOCUMENTS. | | SPECIFIC AUTHORITY 471.008, 471.033(2), FS | | LAW IMPLEMENTED 471.005(7), 471.033(2), FS | | HISTORY?NEW 5-19-93, FORMERLY 21H-32.003, AMENDED | | 4-2-2000, 6-26-01 | | | | 61G15-32.004 DESIGN OF WATER BASED FIRE PROTECTION | | SYSTEMS. | | (1) WATER BASED FIRE PROTECTION SYSTEMS INCLUDE, BUT | | ARE NOT LIMITED TO, AUTOMATIC SPRINKLER SYSTEMS OF WET, | | DRY, FINE WATER SPRAY (MIST), MANUAL, AND DELUGE VALVE | | CONTROLLED TYPES, PUMPING SYSTEMS, STANDPIPES, FIRE | | WATER MAINS AND DEDICATED FIRE PROTECTION WATER | | SOURCES. | | (2) TO ENSURE MINIMUM DESIGN QUALITY IN FIRE PROTECTION | | SYSTEM ENGINEERING DOCUMENTS, SAID DOCUMENTS SHALL | | INCLUDE AS A MINIMUM THE FOLLOWING INFORMATION WHEN | | APPLICABLE: | | (A) THE POINT OF SERVICE FOR THE FIRE PROTECTION WATER | | SUPPLY AS DEFINED BY 633.021(18) F.S. | | (B) APPLICABLE NFPA STANDARD TO BE APPLIED, OR IN THE | | CASE WHERE NO SUCH STANDARD EXISTS, THE ENGINEERING | | STUDY, JUDGMENTS, AND/OR PERFORMANCE BASED ANALYSIS AND | | CONCLUSIONS. | | (C) CLASSIFICATION OF HAZARD OCCUPANCY FOR EACH ROOM OR | | AREA. | | (D) DESIGN APPROACH, WHICH INCLUDES SYSTEM TYPE, | | DENSITIES, DEVICE TEMPERATURE RATING, AND SPACING FOR | | EACH SEPARATE 42 HAZARD OCCUPANCY. | | (E) CHARACTERISTICS OF WATER SUPPLY TO BE USED, SUCH AS | | MAIN SIZE AND LOCATION, WHETHER IT IS DEAD-END OR | | CIRCULATING; AND IF DEAD-END, THE DISTANCE TO THE | | NEAREST CIRCULATING MAIN, AS WELL AS ITS MINIMUM | | DURATION AND RELIABILITY FOR THE MOST HYDRAULICALLY | | DEMANDING DESIGN AREA. | | (F) WHEN PRIVATE OR PUBLIC WATER SUPPLIES ARE USED, THE | | FLOW TEST DATA, INCLUDING DATE AND TIME OF TEST, WHO | | CONDUCTED TEST OR SUPPLIED INFORMATION, TEST ELEVATION, | | STATIC GAUGE PRESSURE AT NO FLOW, FLOW RATE WITH | | RESIDUAL GAUGE PRESSURE, HYDRANT BUTT COEFFICIENT, AND | | LOCATION OF TEST IN RELATION TO THE HYDRAULIC POINT OF | | SERVICE. | | (G) VALVING AND ALARM REQUIREMENTS TO MINIMIZE | | POTENTIAL FOR IMPAIRMENTS AND UNRECOGNIZED FLOW OF | | WATER. | | (H) MICROBIAL INDUCED CORROSION (MIC). THE ENGINEER OF | | RECORD SHALL MAKE REASONABLE EFFORTS TO IDENTIFY WATER | | SUPPLIES THAT COULD LEAD TO MICROBIAL INDUCED CORROSION | | (MIC). SUCH EFFORTS MAY CONSIST OF DISCUSSIONS WITH THE | | LOCAL WATER PURVEYOR AND/OR FIRE OFFICIAL, FAMILIARITY | | WITH CONDITIONS IN THE LOCAL AREA, OR LABORATORY | | TESTING OF WATER SUPPLIES. WHEN CONDITIONS ARE FOUND | | THAT MAY RESULT IN MIC CONTAMINATION OF THE FIRE | | PROTECTION PIPING, THE ENGINEER SHALL DESIGN CORRECTIVE | | MEASURES. | | (I) BACKFLOW PREVENTION AND METERING SPECIFICATIONS AND | | DETAILS TO MEET LOCAL WATER PURVEYOR REQUIREMENTS | | INCLUDING MAXIMUM ALLOWABLE PRESSURE DROP. | | (J) QUALITY AND PERFORMANCE SPECIFICATIONS OF ALL YARD | | AND INTERIOR FIRE PROTECTION COMPONENTS. | | (3) CONTRACTOR SUBMITTALS WHICH DEVIATE FROM THE ABOVE | | MINIMUM DESIGN PARAMETERS SHALL BE CONSIDERED MATERIAL | | DEVIATIONS AND REQUIRE SUPPLEMENTAL ENGINEERING | | APPROVAL AND DOCUMENTATION. | | (4) IN THE EVENT THE ENGINEER OF RECORD PROVIDES MORE | | INFORMATION AND DIRECTION THAN IS ESTABLISHED ABOVE, HE | | OR SHE SHALL BE HELD RESPONSIBLE FOR THE TECHNICAL | | ACCURACY OF THE WORK IN ACCORDANCE WITH APPLICABLE | | CODES, STANDARDS, AND SOUND ENGINEERING PRINCIPLES. | | SPECIFIC AUTHORITY 471.008, 471.033(2), FS | | LAW IMPLEMENTED 471.005(7), 471.033(2), FS | | HISTORY?NEW 5-19-93, FORMERLY 21H-32.004, AMENDED | | 4-2-2000, 6-26-01, 7-12-05 | | | | | | PLEASE REVIEW AND PROVIDE FOR THE REQUIRMENTS UNDER | | THIS MASTER PERMIT IN EITHER NARRATIVE OF DRAWINGS | | SIGNED AND SEALED BY AN EOR LICENSED BY THE THE STATE | | OF FLORIDA. | | | | | | | | 5) SHEET A 1 11 - THERE ARE INDICATIONS OF WHAT APPEARS | | TO BE RACK STORAGE. | | | | PLEASE PROVIDE DETAILS OF WHAT WILL BE STORED AT THIS | | LOCATION, INCLUDING, PRODUCT, WRAPPING, PALLETS AND | | HEIGHT OF OF RACKS. BE SURE TO HAVE THE EOR REVIEW ALL | | APPLICABLE INFORMATION IN THE DESING TO PROTECT THIS | | STORAGE WHICH MAY INCLUDE INRACK FIRE SPRINKLER | | PROTECTION, IF APPLICABLE. | | | | THE RACKS FRAME AND INSTALLATION SHALL BE SUBMITTED | | UNDER SEPARATE SHOP DRAWINGS. | | | | | | | | 6) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | | | 7) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2019-06-03 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-06-03 |
Time |
09:14 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-05-30 |
Time |
14:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2019-05-16 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-05-16 |
Time |
15:58 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-05-13 |
Time |
10:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2019-03-25 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2019-03-25 |
Time |
08:41 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2019-02-28 |
Time |
10:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-02-08 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2019-02-08 |
Time |
15:28 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2019-01-09 |
Time |
11:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2018-11-02 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2018-11-02 |
Time |
19:42 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2018-09-07 |
Time |
13:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2019-05-17 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2019-05-17 |
Time |
07:54 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2019-05-13 |
Time |
10:46 |
Sent To |
|
|
Notes |
2019-05-17 07:55:02 | RECEIPT 2019-0515-394 - $16,142.42 PAID | 2019-05-13 10:46:52 | 5/13/19 SENT EMAIL TO IMPACT FEE OFFICE. LEM |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2018-11-02 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2018-11-02 |
Time |
15:49 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2018-11-02 |
Time |
15:49 |
Sent To |
|
|
Notes |
2018-11-02 15:50:34 | [FBC AMENDED 109]PLANS WILL BE REVIEWED BY THE PBC | | IMPACT FEE OFFICE DIGITALLY VIA PROJECTDOX UPON | | NOTIFICATION BY THIS OFFICE. NOTIFICATION MAY OCCUR | | WHEN PLANS ARE NEAREST FINAL FORM. YOU MAY COORDINATE | | WITH THE IMPACT FEE OFFICE AT (561) 233-5025 OR SIMPLY | | UPLOAD THE MUNICIPAL IMPACT FEE QUESTIONNAIRE FORM TO | | YOUR PROJECT AND NAME THE FILE MUNICIPAL IMPACT FEE | | QUESTIONNAIRE. THE FORM CAN BE FOUND AT: HTTP://DISCOVE | | R.PBCGOV.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QU | | ESTIONNAIRE.PDF UPON APPROVAL AND FEE PAYMENT, PLEASE | | UPLOAD THE RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2019-02-04 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2019-02-04 |
Time |
13:37 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2019-02-04 |
Time |
11:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2018-10-17 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2018-10-17 |
Time |
11:52 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2018-10-17 |
Time |
11:52 |
Sent To |
|
|
Notes |
2018-10-17 11:58:06 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT #18090121 | | 10/17/18 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET M2.1: SHOW THE LOCATIONS OF THE REQUIRED DUCT | | SMOKE DETECTORS IN THE SUPPLY AIR SYSTEMS OF RTU- 1 & 2 | | PER SECTION 606.2.1 FBC M, AND PROVIDE A SEQUENCE OF | | OPERATION FOR FAN SHUTDOWN AND HOW THE DEVICES WILL BE | | SUPERVISED- SECTIONS 606.4 & 606.4.1. | | | | 2) M2.1: THE PLAN DOES NOT CLEARLY SHOW THE LOCATION OF | | THE TOILET ROOM EXHAUST TERMINATION- SECTION 501.3.1 | | FBC M. | | | | 3) M2.1 & M2.2: PROVISDE CONDENSATE DISPOSAL PLANS FOR | | THE RTU'S AND THE AHU- SECTION 307 FBC M. | | | | 4) M2.2 & M6.1: PROVIDE COMPLETE WINDLOAD ENGINEERING | | FOR INSTALLATION OF THE RTU'S AND CURBS, AND FOR THE | | CONDENSER STAND ON THE ROOF- SECTION 301.15 FBC M. | | PLEASE INCLUDE THE DESIGN CRITERIA AS OUTLINED IN | | SECTION 1609 FBC M, AND SUBMIT THE NOA FOR THE STAND. | | | | 5) REFER TO SECTION 306.5 FBC M AND CLARIFY HOW ACCESS | | TO THE ROOFTOP EQUIPMENT IS BEING PROVIDED. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
Rev No |
2 |
Status |
N |
Date |
2019-05-16 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-05-16 |
Time |
15:06 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-05-16 |
Time |
15:06 |
Sent To |
|
|
Notes |
2019-05-16 15:12:03 | APPRAISAL WAS PROVIDED TO SHOW THAT THE ADDITION | | DOESN'T MAKE THIS PROJECT FALL INTO SUBSTANTIAL | | IMPROVEMENT. | | $3,700,00.00 MARKET VALUE | | 1,075,000.00 LAND VALUE | | 2,625,000.00 TOTAL VALUE OF BUILDING MINUS LAND | | | | $950,000.00 TOTAL PROPOSED ADDITION LESS THAN 50% OF | | BUILDING VALUE. |
|
|
Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
Rev No |
1 |
Status |
F |
Date |
2019-03-22 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-03-22 |
Time |
08:16 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-03-22 |
Time |
08:14 |
Sent To |
|
|
Notes |
2019-03-22 08:16:37 | -PENDING NFIP EVALUATION FOR SUBSTANTIAL IMPROVEMENT | | PLEASE PROVIDE CERTIFIED APPRAISAL OR DOCUMENTATION | | FROM PRPOERTY APPRAISER TO SHOW THE VALUE OF THE | | STRUCTURE ONLY. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2019-04-03 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2019-04-03 |
Time |
07:01 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2019-03-25 |
Time |
08:41 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2019-01-28 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2019-01-28 |
Time |
18:25 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2019-01-28 |
Time |
18:25 |
Sent To |
|
|
Notes |
2019-01-28 18:25:47 | 1ST REVIEW: | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | EDITION | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | EDITION | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | EDITION | | | | PLUMBING COMMENTS: | | | | 1. PLEASE PROVIDE SANITARY AND WATER ISOMETRICS | | DRAWINGS. PER WPB AMEND TO FBC 107.3.5.1.3(13) | | | | 2. THE WATER COOLER BRANCH DRAIN SHALL CONNECT TO THE | | BUILDING DRAIN DOWN STREAM OF THE BATHROOM GROUP. PER | | FBC PL 912.1 | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2018-10-19 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2018-10-19 |
Time |
09:52 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2018-10-19 |
Time |
09:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
P |
Date |
2020-03-16 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2020-03-16 |
Time |
14:58 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2020-03-16 |
Time |
14:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
N |
Date |
2019-03-22 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-03-22 |
Time |
08:13 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-03-22 |
Time |
08:13 |
Sent To |
|
|
Notes |
2019-03-22 08:14:34 | PROVIDE PRODUCT APPROVALS WITH SUB PERMIT. | | ROOF DRAINAGE APPROVED IN MASTER 18090121. |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
5 |
Status |
P |
Date |
2019-06-03 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-06-03 |
Time |
09:13 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-06-03 |
Time |
09:13 |
Sent To |
|
|
Notes |
2019-06-03 09:14:16 | SIGNED AND SEALED HARD COPY WAS PROVIDED AND SENT TO | | FILE. | 2019-05-31 14:31:38 | 5/31/19 HARD COPIES ROUTED TO DBATTLES |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
F |
Date |
2019-05-16 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-05-16 |
Time |
15:57 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-05-16 |
Time |
15:57 |
Sent To |
|
|
Notes |
2019-05-16 16:02:04 | PLEASE BRING ONE SIGNED AND SEALED COPY OF PLANS TO THE | | BUILDING DEPARTMENT TO VERIFY SIGNATURES. | | THIS SHOULD BE GIVEN AS A SUBMITTAL TO THE FRONT | | COUNTER AND ONCE VERIFIED SIGNATURE WILL BE APPROVED. | | THE COPY STAYS WITH BUILDING DEPARTMENT RECORDS, SO A | | SITE COPY WILL NEED TO BE PRODUCED IN ADDITION TO THIS | | SIGNATURE VERIFICATION SET. | | | | DYLAN BATTLES | | BUILDING PLANS EXAMINER PX4191 | | [email protected] | | 561-805-6718 | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
F |
Date |
2019-03-22 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-03-22 |
Time |
08:18 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-03-14 |
Time |
12:42 |
Sent To |
|
|
Notes |
2019-03-22 08:22:29 | A FEW SHEETS OUT OF 66 ARE DIGITALLY SIGNED. | | PLEASE CONTACT PERMIT LIBRARIANS TO FINALIZE SIGNATURE | | REQUIREMENTS. |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2019-01-18 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-01-18 |
Time |
16:20 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-01-18 |
Time |
16:20 |
Sent To |
|
|
Notes |
2019-01-18 16:25:32 | SEE PREVIOUS SIGNATURE REVIEW FOR DETAILS. | | THE PAPER SET WILL NEED TO BE UPDATED TO REFECT CHANGES | | MADE TO DRAWINGS FROM BLDG. DEPT. REVIEWS. |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2018-09-11 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2018-09-11 |
Time |
13:12 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2018-09-11 |
Time |
13:11 |
Sent To |
|
|
Notes |
2018-09-11 13:14:00 | SIGNATURE REVIEW WILL BE COMPLETED AFTER ALL PLANS ARE | | APPROVED AND IT IS VERIFIED THAT THE PAPER VERSION ON | | FILE IS CONSISTENT WITH THE PLANS IN THE PROJECTDOX | | FOLDERS. | 2018-09-06 10:41:11 | PAPER PLANS IN LIBRARY FOR SIGNATURES |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2019-03-12 |
Time |
|
Rev Time |
0.00 |
Received By |
pgreilic |
Date |
2019-03-12 |
Time |
12:25 |
Sent To |
|
|
Notes |
2019-03-12 12:25:07 | 1.) REFERENCE CITY OF WPB STANDARD DETAILS FOR PARKING | | STALLS, BIKE RACKS, DUMPSTER ON APPROVED SITE PLAN | | 2.) ALL APPROVED SITE WORK AND LANDSCAPING SHALL BE | | INSTALLED PRIOR TO ISSUANCE OF C.O. FOR BUILDING | | EXPANSION | | 3.) LANDSCAPE PERMIT REQUIRED. INSTALLATION REQUIRED | | PRIOR TO C.O. FOR BUILDING EXPANSION | | | | PAUL GREILICH, SENIOR PLANNER | | (561)-822-1443 | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2019-02-05 |
Time |
|
Rev Time |
0.00 |
Received By |
pgreilic |
Date |
2019-02-05 |
Time |
12:24 |
Sent To |
|
|
Notes |
2019-02-05 09:44:24 | 1.) INCLUDE CITY OF WPB STANDARD DETAILS FOR PARKING | | STALLS, BIKE RACKS, DUMPSTER | | 2.) ALL APPROVED SITE WORK AND LANDSCAPING SHALL BE | | INSTALLED PRIOR TO ISSUANCE OF C.O. FOR BUILDING | | EXPANSION | | 3.) LANDSCAPE PERMIT REQUIRED | | | | PAUL GREILICH, SENIOR PLANNER | | (561)-822-1443 | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2018-10-18 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2018-10-18 |
Time |
16:12 |
Rev Time |
0.00 |
Received By |
pgreilic |
Date |
2018-10-18 |
Time |
16:12 |
Sent To |
|
|
Notes |
2018-10-18 16:14:06 | 1.) INCLUDE CITY OF WPB STANDARD DETAILS FOR PARKING | | STALLS, BIKE RACKS, DUMPSTER | | 2.) ALL APPROVED SITE WORK AND LANDSCAPING SHALL BE | | INSTALLED PRIOR TO ISSUANCE OF C.O. FOR BUILDING | | EXPANSION | | 3.) LANDSCAPE PERMIT REQUIRED | | | | PAUL GREILICH, SENIOR PLANNER | | (561)-822-1443 | | [email protected] |
|
|
|